GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 9 - Renewal Parts 9 - 75 13 CABLE KIT-AC POWER CABLES FB200802AC POWER CABLES INSIDE SCANNER. 1 Y CABLE MAINS SHIELDED 0.3 M 1 PA R T OF KIT CABLE MAINS SHIELDED 0.5 M 1CABLE MAINS SHIELDED 0.7 M1 CABLE MAINS SHIELDED 0.8 M1 CABLE MAINS SHIELDED 0.8 M3 14 CABLE, AC MAINS 1 FB200803 or FC200792 AC Transformer, ACT-M1 to AC Controller, ACP-F6 1Y 15 CABLE, AC MAINS 2 FB200804 or FC200793 AC Transformer, ACT-M2 to AC Controller, ACP-F7 1Y 16 CABLE, 3 HEADED AC POWER CABLE FOR PERHIPHERIAL FC200571 1 Y 16-1CABLE S-VIDEO 1FC200041 IIO-A10 to VCR IN 1Y 16-2CABLE S-VIDEO 2FC200042 BEP1 & BEP2: IIO-A11 to VCR OUT BEP2.2: VIDEO GRABBER (BEP) to VCR OUT 1Y 17V7/L9 AUDIO CABLEFC200572 BEP3.x: IIO - VCR NOTE! A NULL MODEM ADAPTER IS NEEDED IF CON- NECTED TO A PANASONIC VCR 1Y Table 9-57 Cables (cont’d) sheet 3 of 5 CABLE # PART NAME PART NUMBER DESCRIPTIONQTYFRU
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 9 - 76 Section 9-23 - Cables - Vivid 7 17-1 CABLE PHONO 1 FC200043 IIO-A6/A7 to VCR IN CH1(L)/CH2(R) 1Y 17-2 CABLE PHONO 2 FC200044 IIO-A8/A9 to VCR OUT CH1(L)/CH2(R) 1Y 18 CABLE, USB A-B 070D2802 Length: 0.25 meter (9.84 inch) 2Y 19CABLE, ETHERNET CAT-5070D29021Y 20CABLE PCI, AMP 974298070M0016 BEP-PCI slot to Card Rack-IP Module 1Y CORE FLATCABLE FERRIT W/LOCK038X2050USED WITH PCI CABLE1N 21 to 24 Part of other FRUs 25 VGA MONITORCABLE 0.90M 070D2909 CABLE, MONITOR VGA 1Y 25/26 MONITOR CABLE ASSEMBLY 2304171 CABLE, MONITOR VGA + CABLE, MONITOR POWER 1Y 27 CABLE POWER 220V AC PLUG EU070C31941Y NORTH AMERICA POWER CORD51483811Y Table 9-57 Cables (cont’d) sheet 4 of 5 CABLE # PART NAME PART NUMBER DESCRIPTIONQTYFRU
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 9 - Renewal Parts 9 - 77 28CABLES INTERNAL IN AC DISTRIBUTION POWER BO X - PART OF AC DISTRIBUTION POWER BOX 29 CABLE, AUDIO INTERNAL I/O-PC FB200748 IIO-B4 to BEP-AUD 1Y 30 CABLE USB, 1.0 M 070D2800 FOR DIGITAL B/W PRINTER FROM C19 (ON BEP) TO USB ON DIGITAL BW PRINTER) 1Y 30 CABLE, CONSOLE, ASSY COMPLETE FB200320 Top Console and Monitor to IIO, AC CTRL, BEP and Gas Spring 1Y 31CABLE, USB, 2 METER070D2810FOR DIGITAL COLOR PRINTER FROM BEP TO USB ON DIGITAL COLOR PRINTER1Y INTERAL AC POWER CABLE KIT FB200802 AC POWER CABLES INSIDE SCANNER, SEE DESCRIP- TIONS FOR EACH CABLE BELOW.1Y 31-1CABLE MAINS SHIELDED 0.3 M1 PA R T OF KIT 31-2 CABLE MAINS SHIELDED 0.5 M 1 31-3 CABLE MAINS SHIELDED 0.7 M 1 31-4 CABLE MAINS SHIELDED 0.8 M 1 31-5CABLE MAINS SHIELDED 0.8 M3 32CABLE, CONSOLE, ASSY COMPLETEFB200320 Top Console and Monitor to IIO, AC CTRL, BEP and Gas Spring 1Y 33MAIN CABLE KITFD200043FB200320 PLUSS WIRE ASSEMBLY1Y Table 9-57 Cables (cont’d) sheet 5 of 5 CABLE # PART NAME PART NUMBER DESCRIPTIONQTYFRU
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 9 - 78 Section 9-24 - ECG Cables Section 9-24 ECG Cables Table 9-58 ECG Cables ITEMPART NAME PART NUMBER DESCRIPTIONQTYFRU 1 CABLE ECG MARQ. AHA/AMERICA 164L0025 1 Y 2 CABLE ECG MARQ. IEC / EU + AS 164L0026 1 Y 3 LEADWIRES ECG MARQ. AHA/AMERI- CA 164L0027 1 Y 4LEADWIRES ECG MARQ. IEC/EU+AS164L00281Y
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 9 - Renewal Parts 9 - 79 Section 9-25 Physio TX Parts Table 9-59 Physio TX Parts ITEMPART NAMEPART NUMBERDESCRIPTIONQTYFRU 1 Heart Sound Microphone FB200144 PHONO MICR. REDEL CONN. (4 pin connector) HCAT#: H4830JE 1Y 2 Pulse Pressure Transducer FB200147 (5 pin connector) HCAT#: H4830JG 1N Adapter for MA300 heartmicrophone FC200658 1 N Adapter Redel plug - Jack socket FC2009771N
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 9 - 80 Section 9-26 - Probes Section 9-26 Probes 9-26-1 Contents in this Section • 9-26-2 Supported Probes and Software Versions - BT’08 on page 9-80 . • 9-26-3 Supported Probes and Software Versions - BT’06 on page 9-82 . • 9-26-4 Supported Probes and Software Versions - BT’05 on page 9-84 . • 9-26-5 Supported Probes and Software Versions - BT’04 on page 9-86 . • 9-26-6 Supported Probes and Software Versions - BT’01, BT’02 and BT’03 on page 9-88 . 9-26-2 Supported Probes and Software Versions - BT’08 Table 9-60 Supported Probes and Software Versions - BT’08 sheet 1 of 3 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’08 DIMENSION with 4DBT’08 DIMENSION without 4D BT’08 PRO SECTOR PROBE 3S H4701SZ 2323337 3S COMFORT SCAN SECTOR PROBE 1.5 - 3.6 MHz v7.x v7.x v7.x M3S H45011SZ 2295649 M3S AMA SECTOR PROBE 1.5 - 4.3 MHz v7.x v7.x N/A M4SH4000PA5132742M4S SECTOR PROBE 1.5 - 4.3 MHzv7.xv7.xN/A 5SH440422LA23474695S COMFORT-SCANSECTOR PROBE 2.2 - 5.0 MHzv7.xv7.xv7.x 7SH40422LB23474717S COMFORT-SCANSECTOR PROBE 3.0 - 8.0 MHzv7.xv7.xv7.x 10S H4901PC 2298589 10 S SECTOR PROBE 4.0 - 12.0 MHz v7.x v7.x v7.x TEE 6T-OR rev J H45551BG KN100076 PROBE TEE 6T 2.9 - 6.7 MHz v7.x v7.x v7.x 6T-ORH45521DXKN100092PROBE TEE 6T 2.9 - 6.7 MHzv7.xv7.xv7.x 6TH45001YDKN100068PROBE TEE 6T2.9 - 6.7 MHzv7.xv7.xv7.x 6TH45001YDKN100022PROBE TEE 6T2.9 - 6.7 MHzv7.xv7.xv7.x 6T H45531HW KN100069 PROBE TEE 6T FOR JAPAN 2.9 - 6.7 MHz v7.x v7.x v7.x
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 9 - Renewal Parts 9 - 81 9T H45521DY KN100072 PROBE, PEDIATRIC MPTEE 9T 3-3 - 10.0 MHz v7.x v7.x v7.x 6Tv + ADAPTER H45011AA H45001YF KN100062 KZ200476 PROBE, TEE 2.9 - 6.7 MHz Adapter for use on Vivid 7 v7.x v7.x v7.x LINEAR & CONVEX & OTHER 7LH40412LF2294521 7L LINEAR PROBE TYPE (EXP) 2.2 - 8.0 MHz v7.xv7.xv7.x 9LH40412LT5149427 9L LINEAR PROBE TYPE (EXP) 2.3 - 10.0 MHz v7.xv7.xv7.x 10L H40412LG 2294523 10L LINEAR PROBE TYPE (EXP) 4.0 - 10.0 MHz v7.x v7.x v7.x 12L H40412LH 2295377 12L LINEAR PROBE TYPE (EXP) 4.9 - 13 MHz v7.x v7.x v7.x M7C H40412LC 2294514 M7C MIH PROBE 2.9 - 7.0 MHz v7.x v7.x v7.x M12LH40412LD2294511M12L MIH PROBE 4.9 - 14 MHzv7.xv7.xv7.x 3.5CH4901PE20503573.5C CONVEX PROBE 2.0 - 5.0 MHzv7.xv7.xv7.x 4CH4904PC5123455 4C CONVEX PROBE TYPE (EXP) 1.6 - 5.0 MHz v7.xv7.xv7.x 5C H40412LA 2294516 5C CONVEX PROBE TYPE (EXP) 3.0 - 6.7 MHz v7.x v7.x v7.x E8C H40412LE 2294641 E8C PROBE 3.7 - 8 MHz v7.x v7.x v7.x 8C H40412LJ 2348094 8C PROBE 3.7 - 8 MHz v7.x v7.x v7.x INTRAOPERATIVE i8LH45511NWKQ100006I8L INTRAOPERATIVE PROBE 3.9 - 10.0 MHzv7.xv7.xv7.x i13LH45511NTKW100011i13L INTRAOP.PROBE 5.3 - 14.0 MHzv7.xv7.xv7.x PENCIL (DOPPLER) 2D (P2D) H4830JE TE100024 “PEDOF” DOPPLER PROBE - 2 MHz v7.x v7.x v7.x Table 9-60 Supported Probes and Software Versions - BT’08 (cont’d) sheet 2 of 3 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’08 DIMENSION with 4DBT’08 DIMENSION without 4D BT’08 PRO
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 9 - 82 Section 9-26 - Probes 9-26-3 Supported Probes and So ftware Versions - BT’06 6D (P6D)H4830JG TQ100002 “PEDOF” DOPPLER PROBE - 6 MHz5.0 / 5.8 MHz v7.x v7.x v7.x REAL TIME 3D (4D) 3VH4900PC51242954D Probe 1.5 - 4.0 MHzv7.xN/AN/A Table 9-61 Supported Probes and Software Versions - BT’06 sheet 1 of 3 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’06 DIMENSION with 4DBT’06 DIMENSION without 4D BT’06 PRO SECTOR PROBE 3S H4701SZ 2323337 3S COMFORT SCAN SECTOR PROBE 1.5 - 3.6 MHz v6.x v6.x v6.x M3S H45011SZ 2295649 M3S AMA SECTOR PROBE 1.5 - 4.3 MHz v6.x v6.x N/A M4SH4000PA5132742 M4S SECTOR PROBE 1.5 - 4.3 MHz v6.xv6.xN/A 5SH440422LA2347469 5S COMFORT-SCAN SECTOR PROBE 2.2 - 5.0 MHz v6.xv6.xv6.x 7SH40422LB2347471 7S COMFORT-SCAN SECTOR PROBE 3.0 - 8.0 MHz v6.xv6.xv6.x 10S H4901PC 2298589 10 S SECTOR PROBE 4.0 - 12.0 MHz v6.x v6.x v6.x TEE 6T-OR H45521DX KN100092 PROBE TEE 6T 2.9 - 6.7 MHz v6.x v6.x v6.x 6TH45001YDKN100068PROBE TEE 6T 2.9 - 6.7 MHzv6.xv6.xv6.x 6TH45001YDKN100022PROBE TEE 6T2.9 - 6.7 MHzv6.xv6.xv6.x 6TH45531HWKN100069 PROBE TEE 6T FOR JAPAN 2.9 - 6.7 MHz v6.xv6.xv6.x 9T H45521DY KN100072 PROBE, PEDIATRIC MPTEE 9T 3-3 - 10.0 MHz v6.x v6.x v6.x Table 9-60 Supported Probes and Software Versions - BT’08 (cont’d) sheet 3 of 3 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’08 DIMENSION with 4DBT’08 DIMENSION without 4D BT’08 PRO
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 9 - Renewal Parts 9 - 83 6Tv + ADAPTER H45011AA H45001YF KN100062 KZ200476 PROBE, TEE 2.9 - 6.7 MHz Adapter for use on Vivid 7 v6.x v6.x v6.x LINEAR & CONVEX & OTHER 7LH40412LF2294521 7L LINEAR PROBE TYPE (EXP) 2.2 - 8.0 MHz v6.xv6.xv6.x 9LH40412LT5149427 9L LINEAR PROBE TYPE (EXP) 2.3 - 10.0 MHz v6.xv6.xv6.x 10LH40412LG2294523 10L LINEAR PROBE TYPE (EXP) 4.0 - 10.0 MHz v6.xv6.xv6.x 12L H40412LH 2295377 12L LINEAR PROBE TYPE (EXP) 4.9 - 13 MHz v6.x v6.x v6.x M7C H40412LC 2294514 M7C MIH PROBE 2.9 - 7.0 MHz v6.x v6.x v6.x M12L H40412LD 2294511 M12L MIH PROBE 4.9 - 14 MHz v6.x v6.x v6.x 3.5CH4901PE20503573.5C CONVEX PROBE 2.0 - 5.0 MHzv6.xv6.xv6.x 4CH4904PC5123455 4C CONVEX PROBE TYPE (EXP) 1.6 - 5.0 MHz v6.xv6.xv6.x 5CH40412LA2294516 5C CONVEX PROBE TYPE (EXP) 3.0 - 6.7 MHz v6.xv6.xv6.x E8C H40412LE 2294641 E8C PROBE 3.7 - 8 MHz v6.x v6.x v6.x 8C H40412LJ 2348094 8C PROBE 3.7 - 8 MHz v6.x v6.x v6.x INTRAOPERATIVE i8LH45511NWKQ100006I8L INTRAOPERATIVE PROBE 3.9 - 10.0 MHzv6.xv6.xv6.x i13LH45511NTKW100011i13L INTRAOP.PROBE 5.3 - 14.0 MHzv6.xv6.xv6.x PENCIL (DOPPLER) 2D (P2D) H4830JE TE100024 “PEDOF” DOPPLER PROBE - 2 MHz v6.x v6.x v6.x 6D (P6D) H4830JG TQ100002 “PEDOF” DOPPLER PROBE - 6 MHz 5.0 / 5.8 MHz v6.x v6.x v6.x REAL TIME 3D (4D) Table 9-61 Supported Probes and Software Versions - BT’06 (cont’d) sheet 2 of 3 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’06 DIMENSION with 4DBT’06 DIMENSION without 4D BT’06 PRO
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 9 - 84 Section 9-26 - Probes 9-26-4 Supported Probes and So ftware Versions - BT’05 3VH4900PC51242954D Probe 1.5 - 4.0 MHzv6.xN/AN/A Table 9-62 Supported Probes and Software Versions - BT’05 sheet 1 of 2 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’05 DIMENSION with 4DBT’05 DIMENSION without 4D BT’05 PRO SECTOR PROBE 3S H4701SZ 2323337 3S COMFORT SCAN SECTOR PROBE 1.5 - 3.6 MHz V5.x V5.x V5.x M3S H45011SZ 2295649 M3S AMA SECTOR PROBE 1.5 - 4.3 MHz V5.x V5.x N/A M4SH4000PA5132742 M4S SECTOR PROBE 1.5 - 4.3 MHz V5.xV5.xN/A 5SH440422LA2347469 5S COMFORT-SCAN SECTOR PROBE 2.2 - 5.0 MHz V5.xV5.xV5.x 7SH40422LB2347471 7S COMFORT-SCAN SECTOR PROBE 3.0 - 8.0 MHz V5.xV5.xV5.x 10S H4901PC 2298589 10 S SECTOR PROBE 4.0 - 12.0 MHz V5.x V5.x V5.x TEE 5T + ADAPTER H45001YF KZ200476 PROBE TEE 5T 2.9 - 6.7 MHz Adapter for use on Vivid 7 v5.x v5.x v5.x 6T-ORH45521DXKN100092PROBE TEE 6T 2.9 - 6.7 MHzV5.xV5.xV5.x 6TH45001YDKN100068PROBE TEE 6T2.9 - 6.7 MHzV5.xV5.xV5.x 6TH45001YDKN100022PROBE TEE 6T 2.9 - 6.7 MHzV5.xV5.xV5.x 6T H45531HW KN100069 PROBE TEE 6T FOR JAPAN 2.9 - 6.7 MHz V5.x V5.x V5.x 9T H45521DY KN100072 PROBE, PEDIATRIC MPTEE 9T 3-3 - 10.0 MHz V5.x V5.x V5.x Table 9-61 Supported Probes and Software Versions - BT’06 (cont’d) sheet 3 of 3 PROBESCAT NO. PART NUMBER NAME SUPPORTED MODELS & SW VERSION BT’06 DIMENSION with 4DBT’06 DIMENSION without 4D BT’06 PRO