GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 87 3-9-18-3 Examination List Screen Figure 3-91 Examination List Screen Table 3-19 Examination List Screen ITEMVIVID 7 FIELD NAMEDICOM TAG NUMBERDICOM TAG NAME 1 REFERRAL REASON (0010,2180) ADDITIONAL PATIENT’S HISTORY 2 DIAGNOSIS (0008,103E) SERIES DESCRIPTION 1 2
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 88 Section 3-9 - Connectivity Setup - Software v7.x (BT’08), v6.x, v5.x and v4.x 3-9-18-4 Worklist Search Screen Figure 3-92 Worklist Search Screen Table 3-20 Worklist Search Screen ITEMVIVID 7 FIELD NAMEDICOM TAG NUMBERDICOM TAG NAME 1 LAST NAME, FIRST NAME (0010,0010) PATIENT’S NAME 2 SEX (0010,0040) PATIENT’S SEX 3 ACCESSION (0008,0050) ACCESSION NUMBER 4BIRTHDATE(0010,0030)PAT I E N T ’ S B I RT H D AT E 5PATIENT ID(0010,0020)PATIENT ID 6STUDY ID(0040,1001)REQUESTED PROCEDURE ID 7 EXAM BETWEEN (0040,0002) SCEDULED PROCEDURE STEP START DATE 1 2 45 7 [ACCESSION FIELD AVAILABLE ON SOME SOFTWARE VERSIONS] 6 [ STUDY ID FIELD AVAILABLE ON SOME SOFTWARE VERSIONS (NOT SHOWN HERE)] 3
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 89 Section 3-10 Connectivity Setup - Software v3.x NOTE: If connected to a stand-alone network (Peer-to-Peer network with a Vivid 7 scanner, an EchoPAC PC Workstation and an optional network printer), you should use default delivery settings. 3-10-1 Introduction To be able to use the network functions when con nected to a hospital network, the scanner must have a proper network address. • Before you can set up the scanner, you need to collect some information. The Pre-quote Worksheet for DICOM Network Information on page 2-14 can be used for gathering this information. Typical source for this in formation is the network administrator. • Follow the steps below to prepare the scanner for use on the network. 3-10-2 Contents in this Section • 3-10-3 Compatib ility on page 3-89 • 3-10-4 Select TCP/IP Set-up Screen - Software Version v3.x on page 3-90 • 3-10-5 Set the Scanner’s Network Information - Software Version v3.x on page 3-91 • 3-10-6 Set the Remote Archive’s Network Information - Software Version v3.x on page 3-92 • 3-10-7 Save the New Settings on page 3-92 • 3-10-8 Connect to a DICOM Server in a Network - Software Version v3.x on page 3-93 • 3-10-9 HL7 Communication Setup - Software v3.x on page 3-98 • 3-10-10 Query/Retrieve (Q/R) Setup for Software v3.x on page 3-102 3-10-3 Compatibility Vivid 7 with Software Version v3.3.x (System Software v1.5.1) can communicate with: • EchoPAC PC with software version v3.3.x • EchoPAC PC with software version v4.x • EchoPAC PC with software version v5.x • EchoPAC PC with software version v6.x • EchoPAC PC with software version v7.x • Image Vault 3 • Image Vault 4 • EchoServer 7
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 90 Section 3-10 - Connectivity Setup - Software v3.x 3-10-4 Select TCP/IP Set-up Scr een - Software Version v3.x 1.) Press CONFIG (F2) and log on as adm, see 4-2-4 Log On to the System as ‘ADM’ on page 4-12 . 2.) If not already selected, select CONNECTIVITY from the bottom row of “buttons” on the screen. 3.) Select the TCP/IP TAB (it is named Tcpip). . Figure 3-93 TCP/IP Set-up screen for Vivid 7, Overview (Example) Computer Name: For Vivid 7, this name is on the form: Vivid7- 00nnnn , where “00nnnn” is a number (nnnn is the scanner’s serial number). IP SETTINGS: IP SETTINGS AREA FOR THE Vivid 7 SCANNER. DEFAULT SETUP: IP-ADDRESS: 10.0.0.3 SUBNET MASK: 255.255.255.255 GATEWAY: 0.0.0.0 Remote Archive Setup area: IP settings area for a Remote Archive. Example: EchoServer. Default Setup: Remote Archive IP-Addr: 10.0.0.4 Remote Archive Name: EchoPAC7-000001 The AETitles field and the Port field are onl y available on BT’03 software (and beyond).
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 91 3-10-5 Set the Scanner’s Network Information - Software Version v3.x In the IP settings area of the screen, enter the; 1.) IP Address for scanner. (Default IP Address from factory: 10.0.0.3). 2.) Subnet Mask for scanner. (Default Subn et Masks from factory: 255.255.255.0). 3.) IP address for Default Gateway. (Default Gateways from factory IP address: 0.0.0.0). 4.) In addition, the AE Title for the scanner mu st be entered in the DICOM server’s setup. . Figure 3-94 TCP/IP Set-up for Vivid 7 IP Address Subnet Mask Default Gateway AETitle Port Number
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 92 Section 3-10 - Connectivity Setup - Software v3.x 3-10-6 Set the Remote Archive’s Networ k Information - Software Version v3.x In the Remote Archive Setup area of the screen (see example in Figure 3-95), enter the; 1.) Remote Archive IP address. (Default IP Address from factory: 10.0.0.4). 2.) Remote Archive Name. (Default Remote Ar chive Name from factory: ECHOPAC7-000001). . 3-10-7 Save the New Settings 1.) Press SAVE SETTINGS to save the new settings. . 2.) The new settings are saved to a common settings file. After a restart, the settings are also included in other screens. 3.) Restart Vivid 7 to activate the changes. Figure 3-95 TCP/IP Set-up for Vivid 7 Figure 3-96 Save New TCP/IP settings IP Address for the remote archive Computer Name for the remote archive Save settings
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 93 3-10-8 Connect to a DICOM Server in a Network - Software Version v3.x In this case the Vivid 7 is configured to work with DICOM servers in a network environment. Images are first saved on the local image buffer on the scanner. At the end of the examination the images are sent to the DICOM server via a DICOM spooler and to the local database, depending on dataflow. This scenario requires that the scanner is configur ed to be connected to DICOM servers as described below. 3-10-8-1 Overview To work against the DICOM server, the following information has to be entered in the scanner: • The DICOM server IP address. • The DICOM server port number. • The DICOM server AE title (the server application’s name). • Name of Device. 3-10-8-2 DICOM Server IP Address Setting on the Scanner - Software Version v3.x 1.) Press CONFIG (F2) and log on as adm, see 4-2-4 Log On to the System as ‘ADM’ on page 4-12 . 2.) Select CONNECTIVITY (in the lower part of the window). 3.) Select the DATAFLOW tab. 4.) Select the arrow to the right for the Name field to list all dataflows in a pull-down menu, see Figure 3-97 . 5.) Select the dataflow you want to configure from the Dataflow Name pull-down list, see Figure 3-97. Figure 3-97 Select Dataflow Arrow Select dataflow from Dataflow Name pull-down menu.
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 94 Section 3-10 - Connectivity Setup - Software v3.x 3-10-8-2 DICOM Server IP Address Setting on the Scanner - Software Version v3.x (cont’d) In Figure 3-98 , the selected flow, Worklist/Local Arch ive - DICOM Server/Int. HD, is shown. 6.) Select Worklist (so it is highlighted) and then se lect Properties to display the Properties dialog. Figure 3-98 Worklist/Local Archive - DICOM Server/Int. HD flow Figure 3-99 Select Worklist Properties dialog Select Worklist and then select Properties Worklist Properties dialog
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 95 3-10-8-2 DICOM Server IP Address Setting on the Scanner - Software Version v3.x (cont’d) 7.) Select the IP-Address down-arrow to choose the Worklist Server from the pull-down menu. NOTE: It is not possible to change the setting in the IP-Address field by editing it. See description below, starting with step 8, to change the setting. 8.) Follow the steps below to change the IP-Address settings: a.) From the Ip-Address pull-down menu, select to display the IPs dialog. b.) Select the server you want to modify fr om the IPs dialog and then select Modify. Figure 3-100 DICOM Server’s Properties dialog Figure 3-101 Select Figure 3-102 Select the unit to modify Modify Select server
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 96 Section 3-10 - Connectivity Setup - Software v3.x 3-10-8-2 DICOM Server IP Address Setting on the Scanner - Software Version v3.x (cont’d) c.) Edit the name and/or the IP address of the server, see Figure 3-103. d.) Select OK to save the new settings and close the dialog. e.) Select OK to close the IPs dialog to return to the Properties dialog. f.) Enter the DICOM server AE Title. This entr y is case sensitive and must match exactly. g.) Enter the DICOM server port. h.) Select OK to close the Worklist properties dialog and save any changes. Figure 3-103 Edit Name and/or IP address Figure 3-104 DICOM Server’s Properties dialog Name IP address AE Title Port No