    							5210TL-130200-10012.If C register is 00, 02, 03, 05, 06, or 07, complete the following
    steps:
    -Force CIPNCIPIDVCIP 00s - FORCE CIP CA X YY OS.
    x=PEC 
    #3, Always 0 orFORCE VPLC (PEC GRP SLOT)
    W=CARD 30 -15
    -Remove and replace CIPNCIPIDVCIP, FB -17235
    A/17236-A in identified slot (check strapping).
    -Force CIPNCIPIDVCIPNP20 INS - FORCE CIP CA X YY IS.
    x=
    PEC#, Always 0 orFORCE VPLC (PEC GRP SLOT)
    W=CARD #O -15
    3.If PCB replaced is a VCIP/DVCIP, FB-17235-A/17236-A, force
    download the PCB as follows:
    -Identify data links associated with relative card number of the
    .
    VCIP/DVCIP (i.e., VCIP #O/DVCIP #0 = Data Links O-7, VCIP
    #DVCIP #l= Data Links 8-15, etc.)
    -Identify any SID associated with any previously defined data
    link by reading Table 
    T7054-0.
    -Force download of this VCIPIDVCIP using the previously
    defined 
    SiD:Force download X YYY IN.
    x=PEC#, Always 0
    YYY=SID 
    #O-255
    4.If fault recurs, reinstall original 
    CIPNCIPIDVCIPnIP20 card and
    download.
    5.Identify MPB85, FB-17215-A associated with identified
    CIPNCIPIDVCIP card:
    MPB85PCMUS GROUP
    Y/O5Groups A & B
    X/o4Groups C & D
    6.Power down system - turnoff main circuit breaker at rear of
    OMNI SI cabinet.
    7.Remove and replace MPB85, FB-17215-A previously
    identified.
    8.Power up system.
    9.Monitor PSUPY card in P/O1 for ASW LED to light.
    10.If C register value is 04, complete the following steps:
    -If a CIPIVCIPIDVCIPNP20 card is supposed to be in an
    unequipped slot, install a CIPNCIPIDVCIP card.
    -.If a CIP/VCIP/DVCIP card is correctly installed in the PCMUS,
    follow procedures for C register value 00 listed above.
    8187M-145 
    						
    							TL130200-1001
    FAULT CODE 321FAULT CODE 
    - 32
    II1FORCE 
    CIP/VCIP/DVCIP
    b CARD OS: FORCE CIP CA X
    w OS.
    $rFORCE CIPNCIPIDVCIP
    CARD.
    CIP, FB-17225VCIP, FB-17235
    DVCIP, FB-17236
    4
    IFORCE CIPNCIPIDVCIP
    CARD INS:FORCE CIP CA X YY IS.
    x-YES
    IDENTIFY DATA LINKS
    ASSOCIATED WITH 
    VCIP/DVCIP RELATIVE CARD NO.
    NO
    NO
    NOREINSTALL ORIGINAL
    VCIP, 
    FB-I 7235 OR
    DVCIP, FB-17236IDENTIFY MPB85,
    rFB-17215ASSOCIATED WITH
    PCMUS HOUSING
    CIPNCIPIDVCIP
    CARD
    +POWER DOWN
    SYSTEM
    +R&R MPB85, 
    FB-17215 PREVIOUSLY 
    -
    IDENTIFIED
    -AENDM-146
    ah375210 
    						
    							TL-130200-1001Fault Code 33Description:
    CIPNCIPIDVCIPThis fault indicates a failure in the Integrated/Digital
    Port FailureFeaturephone cabling or CIPNCIPIDVCIP card.
    5210
    Register Data as System Prints:CECO CECO Fault 33 B C 
    D E H L
    00 00 00
    00= Data Link Error
    01= CIP Port Protocol Error
    02= Port Sync Error
    03= Port Enable Error
    04 = CIP Other Port Errors
    05= Test Failure
    06 = Download Failure
    07 = Port Recovery Errors
    Fault Resolution Steps:
    1.Identify and locate Featurephone associated with fault report
    (customer complaint) or determine DN by deciphering port
    number
    2.Ensure that Featurephone is powered up.
    3.Run self-test - TEST PHONE DN XXXX or TEST DN
    XXXX. If test fails, remove and replace Featurephone.
    4.If Featurephone passes self-test, complete the following
    steps:
    - At system maintenance terminal call up Recent Change
    menu 117 to show the PCMUS associated with the
    CIP/VCIP/DVCIP. When PCMUS is defined, identify
    CIPNCIPIDVCIP relative card number location by
    performing a general read of 17053-O address 
    (B2Fthrough 
    OB3E) as shown below:
    GR D2 
    OB2F OB3E.
    OB2F = Relative Cl Card No. 0
    OB30 = Relative Cl Card No. 1
    OB31= Relative Cl Card No. 2
    OB32 = Relative Cl Card No. 3
    OB33 = Relative Cl Card No. 4
    OB34 = Relative Cl Card No. 5
    0835 = Relative Cl Card No. 6
    OB36 =Relative Cl Card No. 7
    8167M-l 47 
    						
    							TL-130200-1001
    0637 =
    Relative Cl Card No. 8
    OB38 =
    Relative Cl Card No. 9
    0839 =
    Relative Cl Card No. 10
    063A =
    Relative Cl Card No. 11
    OB3B =
    Relative Cl Card No. 12
    OB3C =
    Relative Cl Card No. 13
    OB3D =Relative Cl Card No. 14
    OB3E =Relative Cl Card No. 15
    - Using the relative Cl card number, force the
    CIP/VCIP/DVCIP 00s.Force 
    CIPAJCIPIDVCIP 00s - FORCE CIP CA X YY OS.
    x=PEC#, Always 0
    YY=CARD #O-l 5
    - Remove and replace CIPNCIPIDVCIP, FB-17235
    A/l 7236-A in identified slot (check strapping).
    Force CIPNCIPIDVCIP INS 
    - FORCE CIP CA X YY IS.
    x=
    PEC#, Always 0
    YY=
    CARD #O-l 5
    - If PCB replaced was a VCIPIDVCIP, F&17235-
    A/17236-A, force download PCB as follows:
    - Identify data links associated with relative card number of
    the 
    VCIPIDVCIP (i.e., VCIP/DVCIP #0 = Data Links O-7,
    VCIP/DVCIP #l= Data Links 8-15,etc.).
    - Identify any SID associated with any previously defined
    data link by reading Table T-7054.
    - Force download of this VCIP/DVCIP using the previously
    defined SID:
    Force download X YYY IN.
    X = 
    PEC#, Always 0
    YYY=SID #O-255
    - If fault recurs, reinstall original CIPIVCIPIDVCIP card.
    - Identify MPB85, FB-17215-A, associated with PCM
    group housing identified 
    CIP/VCIP/DVCIP card.
    MPB85PCMUS GROUP
    Y/O5Group A & B
    x/o4Group C 
    & D
    5.Power down system 
    - turn off main circuit breaker at rear of
    OMNI Sl cabinet.
    6.Remove and replace MPE385, FB-17215-A, previously
    identified.
    7.Power up system.
    8.Monitor PSUPY in P/O1 for ASW LED to light.
    M-148
    81875210 
    						
    							RUN SELF-TEST ON
    FEATUREPHONE TEST
    PHONE, DN XXXX, OR
    TEST DN XXXX.TL-130200-1001
    IDENTIFY ANY SID
    ASSOCIATED WITHPREVIOUSLY DEFINEDDATA LINKS
    RELATIVE CARD NO.
    4ASSOCIATED WITH
    FORCE DOWNLOADON 
    VCIP/DVCIP:
    FORCE DOWNLOADX YYY IN.
    fREINSTALL ORIGINAL
    VCIP, FB-17235, OR
    DVCIP, FB-17236
    IREINSTALL ORIGINAL
    CIP, FB-17225 CARDIDENTIFY MPB85,
    FB-17215ASSOCIATED WITH
    PCMUS HOUSING
    ClPNClPlDVClP CARD PCMUS ASSOCIATION
    CIPNCIPIDVCIP PCB
    VCIP/DVCIP RELATIVE
    FEATUREPHONE
    ‘ZIP, FB-17225
    VCIP, FB-17235
    DVCIP, FB-172365210
    8l87M-149 
    						
    							TL-130200-1001Fault Code 36Description:
    Change MDR SystemThis fault indicates that receiving a CRIB (Call Record
    Clock FailureInformation Buffer) from the idle crib list failedThe indication isthat MDR failed to change its system clock after a request from a
    user. If this happens, there were too many calls in progress to
    handle the request.
    M-l 50
    Register Data as System Prints:CECO CECO Fault 36 B C D E H L
    ,xx,,xx,,xx,\xx/?
    						
    							TL-130200-1001Fault’Code 37Description:
    System Warm StartFault Code 37 is generated every time a warm or cold start
    occurs in the system. Register B in Fault Code 37 contains the
    total count of warm starts which have occurred since the last
    cold start. If Register B= 0, then a cold start has occurred.
    Register C contains the threshold count for this fault. If register C
    contains any value other than 0, the system has attempted a
    warm start in 4 minutes or less since the last warm start. If
    register C is 5, the system will attempt a cold start.
    hedster Data as Svstem Prints:
    -CECO CECO 
    						
    							TL-130200-1001Fault Code 41Description:
    FMS Disk ErrorThis fault indicates genera
    M-l 52.I disk I/O errors.
    Register Data as System Prints:CECO CECO Fault 41 B C D E H L
    rRequest which failed
    OE =Writing Out Data Base
    14 =Writing Out 
    HC/M
    1D =Downloading F/P File
    1F= Closing F/P File
    Error CodeDCBDRB Start
    FF 
    =.SequenceAddress
    TimeoutIndex(Low Byte)
    (TCSIX)
    Fault Resolution Steps:
    1.Repeat the task that was being performed when fault
    occurred. If fault recurs, continue.
    2.If the C register value is FF, this might indicate a hardware
    problem. Complete the following steps:
    - Power down - turn off main circuit breaker at rear of
    OMNI SI cabinet.
    - Remove and replace FMSD, FB-17220-BOA, in Y/O7(check strapping).
    - Power up system.
    - Monitor PSUPY card in P/O1 for ASW LED to light.
    - If fault recurs, remove and replace the floppy disk drive.
    - If fault still recurs after performing above procedures, this
    indicates an internal data base or software problem and
    the technician should call for assistance.
    71875210 
    						
    							TL-130200-1001. c-w-. VVIb -r. 
    .REPEATTASK
    JUST PERFORMED
    +.
    NO
    * YESC=FF
    FB-17220 IN 
    Y/O7PSUPY FOR
    NO
    * YES
    R&R FLOPPY
    DISK DRIVE
    52107187M-153 
    						
    							TL-130200-1001Fault Code 42Description:
    Time Slot LockupFault Code 42 is generated when a time slot lockup is detected.When allocating a time slot, a check should be made to see if the
    hardware ID is already in channel memory. If it is, then a time
    slot is locked up. The old time slot is released before allocating
    the new time slot.
    Register Data as System Prints:CECO CECO Fault 42 B C D E H L
    00 \xx y \xx 00 00
    Hardware
    IDTime Slot Call Store
    NumberNumber
    M-l 54
    71875210 
    						
    All GTE manuals Comments (0)