5210TL-130200-10012.If C register is 00, 02, 03, 05, 06, or 07, complete the following steps: -Force CIPNCIPIDVCIP 00s - FORCE CIP CA X YY OS. x=PEC #3, Always 0 orFORCE VPLC (PEC GRP SLOT) W=CARD 30 -15 -Remove and replace CIPNCIPIDVCIP, FB -17235 A/17236-A in identified slot (check strapping). -Force CIPNCIPIDVCIPNP20 INS - FORCE CIP CA X YY IS. x= PEC#, Always 0 orFORCE VPLC (PEC GRP SLOT) W=CARD #O -15 3.If PCB replaced is a VCIP/DVCIP, FB-17235-A/17236-A, force download the PCB as follows: -Identify data links associated with relative card number of the . VCIP/DVCIP (i.e., VCIP #O/DVCIP #0 = Data Links O-7, VCIP #DVCIP #l= Data Links 8-15, etc.) -Identify any SID associated with any previously defined data link by reading Table T7054-0. -Force download of this VCIPIDVCIP using the previously defined SiD:Force download X YYY IN. x=PEC#, Always 0 YYY=SID #O-255 4.If fault recurs, reinstall original CIPNCIPIDVCIPnIP20 card and download. 5.Identify MPB85, FB-17215-A associated with identified CIPNCIPIDVCIP card: MPB85PCMUS GROUP Y/O5Groups A & B X/o4Groups C & D 6.Power down system - turnoff main circuit breaker at rear of OMNI SI cabinet. 7.Remove and replace MPB85, FB-17215-A previously identified. 8.Power up system. 9.Monitor PSUPY card in P/O1 for ASW LED to light. 10.If C register value is 04, complete the following steps: -If a CIPIVCIPIDVCIPNP20 card is supposed to be in an unequipped slot, install a CIPNCIPIDVCIP card. -.If a CIP/VCIP/DVCIP card is correctly installed in the PCMUS, follow procedures for C register value 00 listed above. 8187M-145
TL130200-1001 FAULT CODE 321FAULT CODE - 32 II1FORCE CIP/VCIP/DVCIP b CARD OS: FORCE CIP CA X w OS. $rFORCE CIPNCIPIDVCIP CARD. CIP, FB-17225VCIP, FB-17235 DVCIP, FB-17236 4 IFORCE CIPNCIPIDVCIP CARD INS:FORCE CIP CA X YY IS. x-YES IDENTIFY DATA LINKS ASSOCIATED WITH VCIP/DVCIP RELATIVE CARD NO. NO NO NOREINSTALL ORIGINAL VCIP, FB-I 7235 OR DVCIP, FB-17236IDENTIFY MPB85, rFB-17215ASSOCIATED WITH PCMUS HOUSING CIPNCIPIDVCIP CARD +POWER DOWN SYSTEM +R&R MPB85, FB-17215 PREVIOUSLY - IDENTIFIED -AENDM-146 ah375210
TL-130200-1001Fault Code 33Description: CIPNCIPIDVCIPThis fault indicates a failure in the Integrated/Digital Port FailureFeaturephone cabling or CIPNCIPIDVCIP card. 5210 Register Data as System Prints:CECO CECO Fault 33 B C D E H L 00 00 00 00= Data Link Error 01= CIP Port Protocol Error 02= Port Sync Error 03= Port Enable Error 04 = CIP Other Port Errors 05= Test Failure 06 = Download Failure 07 = Port Recovery Errors Fault Resolution Steps: 1.Identify and locate Featurephone associated with fault report (customer complaint) or determine DN by deciphering port number 2.Ensure that Featurephone is powered up. 3.Run self-test - TEST PHONE DN XXXX or TEST DN XXXX. If test fails, remove and replace Featurephone. 4.If Featurephone passes self-test, complete the following steps: - At system maintenance terminal call up Recent Change menu 117 to show the PCMUS associated with the CIP/VCIP/DVCIP. When PCMUS is defined, identify CIPNCIPIDVCIP relative card number location by performing a general read of 17053-O address (B2Fthrough OB3E) as shown below: GR D2 OB2F OB3E. OB2F = Relative Cl Card No. 0 OB30 = Relative Cl Card No. 1 OB31= Relative Cl Card No. 2 OB32 = Relative Cl Card No. 3 OB33 = Relative Cl Card No. 4 OB34 = Relative Cl Card No. 5 0835 = Relative Cl Card No. 6 OB36 =Relative Cl Card No. 7 8167M-l 47
TL-130200-1001 0637 = Relative Cl Card No. 8 OB38 = Relative Cl Card No. 9 0839 = Relative Cl Card No. 10 063A = Relative Cl Card No. 11 OB3B = Relative Cl Card No. 12 OB3C = Relative Cl Card No. 13 OB3D =Relative Cl Card No. 14 OB3E =Relative Cl Card No. 15 - Using the relative Cl card number, force the CIP/VCIP/DVCIP 00s.Force CIPAJCIPIDVCIP 00s - FORCE CIP CA X YY OS. x=PEC#, Always 0 YY=CARD #O-l 5 - Remove and replace CIPNCIPIDVCIP, FB-17235 A/l 7236-A in identified slot (check strapping). Force CIPNCIPIDVCIP INS - FORCE CIP CA X YY IS. x= PEC#, Always 0 YY= CARD #O-l 5 - If PCB replaced was a VCIPIDVCIP, F&17235- A/17236-A, force download PCB as follows: - Identify data links associated with relative card number of the VCIPIDVCIP (i.e., VCIP/DVCIP #0 = Data Links O-7, VCIP/DVCIP #l= Data Links 8-15,etc.). - Identify any SID associated with any previously defined data link by reading Table T-7054. - Force download of this VCIP/DVCIP using the previously defined SID: Force download X YYY IN. X = PEC#, Always 0 YYY=SID #O-255 - If fault recurs, reinstall original CIPIVCIPIDVCIP card. - Identify MPB85, FB-17215-A, associated with PCM group housing identified CIP/VCIP/DVCIP card. MPB85PCMUS GROUP Y/O5Group A & B x/o4Group C & D 5.Power down system - turn off main circuit breaker at rear of OMNI Sl cabinet. 6.Remove and replace MPE385, FB-17215-A, previously identified. 7.Power up system. 8.Monitor PSUPY in P/O1 for ASW LED to light. M-148 81875210
RUN SELF-TEST ON FEATUREPHONE TEST PHONE, DN XXXX, OR TEST DN XXXX.TL-130200-1001 IDENTIFY ANY SID ASSOCIATED WITHPREVIOUSLY DEFINEDDATA LINKS RELATIVE CARD NO. 4ASSOCIATED WITH FORCE DOWNLOADON VCIP/DVCIP: FORCE DOWNLOADX YYY IN. fREINSTALL ORIGINAL VCIP, FB-17235, OR DVCIP, FB-17236 IREINSTALL ORIGINAL CIP, FB-17225 CARDIDENTIFY MPB85, FB-17215ASSOCIATED WITH PCMUS HOUSING ClPNClPlDVClP CARD PCMUS ASSOCIATION CIPNCIPIDVCIP PCB VCIP/DVCIP RELATIVE FEATUREPHONE ‘ZIP, FB-17225 VCIP, FB-17235 DVCIP, FB-172365210 8l87M-149
TL-130200-1001Fault Code 36Description: Change MDR SystemThis fault indicates that receiving a CRIB (Call Record Clock FailureInformation Buffer) from the idle crib list failedThe indication isthat MDR failed to change its system clock after a request from a user. If this happens, there were too many calls in progress to handle the request. M-l 50 Register Data as System Prints:CECO CECO Fault 36 B C D E H L ,xx,,xx,,xx,\xx/?
TL-130200-1001Fault’Code 37Description: System Warm StartFault Code 37 is generated every time a warm or cold start occurs in the system. Register B in Fault Code 37 contains the total count of warm starts which have occurred since the last cold start. If Register B= 0, then a cold start has occurred. Register C contains the threshold count for this fault. If register C contains any value other than 0, the system has attempted a warm start in 4 minutes or less since the last warm start. If register C is 5, the system will attempt a cold start. hedster Data as Svstem Prints: -CECO CECO
TL-130200-1001Fault Code 41Description: FMS Disk ErrorThis fault indicates genera M-l 52.I disk I/O errors. Register Data as System Prints:CECO CECO Fault 41 B C D E H L rRequest which failed OE =Writing Out Data Base 14 =Writing Out HC/M 1D =Downloading F/P File 1F= Closing F/P File Error CodeDCBDRB Start FF =.SequenceAddress TimeoutIndex(Low Byte) (TCSIX) Fault Resolution Steps: 1.Repeat the task that was being performed when fault occurred. If fault recurs, continue. 2.If the C register value is FF, this might indicate a hardware problem. Complete the following steps: - Power down - turn off main circuit breaker at rear of OMNI SI cabinet. - Remove and replace FMSD, FB-17220-BOA, in Y/O7(check strapping). - Power up system. - Monitor PSUPY card in P/O1 for ASW LED to light. - If fault recurs, remove and replace the floppy disk drive. - If fault still recurs after performing above procedures, this indicates an internal data base or software problem and the technician should call for assistance. 71875210
TL-130200-1001. c-w-. VVIb -r. .REPEATTASK JUST PERFORMED +. NO * YESC=FF FB-17220 IN Y/O7PSUPY FOR NO * YES R&R FLOPPY DISK DRIVE 52107187M-153
TL-130200-1001Fault Code 42Description: Time Slot LockupFault Code 42 is generated when a time slot lockup is detected.When allocating a time slot, a check should be made to see if the hardware ID is already in channel memory. If it is, then a time slot is locked up. The old time slot is released before allocating the new time slot. Register Data as System Prints:CECO CECO Fault 42 B C D E H L 00 \xx y \xx 00 00 Hardware IDTime Slot Call Store NumberNumber M-l 54 71875210