GTE Omni Si Database Technical Practices Manual
Have a look at the manual GTE Omni Si Database Technical Practices Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
TL-130400-1001Table 15.8BEntry Fields for Record Code TL (Continued)COMMENTS AC = transaction record is printed when message meteringis activated. meteringis activatedor deactivated. -If more thanoneprinter is used, enter the values (e.g., if printers 0 and 3; if printers 2 and 3 are conditions required out to be activated when this feature AC = transaction record is printed wh message metering is activated. DE = transaction record is printed when message metering is deactivated. BT= transaction record is printed when -If only one printer is used, enter the printer value 01, 02, 04, or 08. SW 52108187D-295
TL-130400-1001Record Code AL:15.9 Record Code AL, Figure 15.9, assigns a printer to a KEDU Audit Recordfor the audit functions associated with that KEDU. The printer is Controlassigned the following values: l Printer No. 0 is assigned the value 01. * Printer No. 1 is assigned the value 02. o Printer No. 2 is assigned the value 04. l Printer No. 3 is assigned the value 08. . . . . D-296The printer ID identifies a specific printer number or several printer numbers, depending on the value range entered. If more than one printer is to be designated, use Table 15.9A. Example: printer numbers 0 and 3 have the value of 9. Printer IDS and ‘numbers are found in Table 15.9A.Table 15.9A Printer ID NumberPrinter Number(s) I 11206I 110, 1, 3 12 2,3 130, 2, 3 141, 2, 3 150, 1, 2, 3 8187SVR 5210
TL-130400-1001I IITI I NIII DI:II EII I XI:I.-----r---r-r-------r-------r--------------------------------------A----------- xJ( MI I I I I I -.. I I I t II I I t I I I I I ItI-+-T-f-T-T-;-T-+-I1 I1 I1 I1 I1 I1 I1 I.71819101112131415161; -+-+-u-+-+-+-+-+-+.4,OlOlAl LlOl I I I I--A--L-A-L-L-L-*- I-T-f--r-t-T-+-T-t-r-+-T-I I1 11121212121212121212 718191011 12131415161718 -+-c-+-+-+-+-+-+-+-+-+-I I I, I, I I I I I-~-~-~-~-*-~-*-~-*-*-*- -T-f-T-t-T-f-T-&T-T-T-T-T-I!131313131313131313131414141i8110111213141516171819101112, IO -+-c-+-+-+-+-+-+-+-c-+-+-+-4 c- l I I I I I I I I I I I I I I-A-*-A-A.-A-*-A-A--L-A . . . 4-LTable 15.98 Entry Fields for Record Code AL F-pi-VALID ENTRIESCOMMENTS 12KEDU Number 13-14Message Meter Function StatusFigure 15.9 Record Code AL: Audit Record Control Data Sheet O-3 = numberThis field determines the selected KEDU number and is used by the system for identification purposes. -This number must be defined on Record Code KD. AL = messagemetering information is to be printed-- = metering information is not to be printedEnter AL if the printer(s) can accept message metering information associated with a KEDU. -Columns 15-l 6 indicate which printer(s) will print this information. -l’,lke; entered, columns 15-16 cannot be SVR 5210 8187D-297
rTL--l30400-1001Table 15.95 Entry Fields for Record Code AL (Continued)COMMENTS rrnter Numberaccept message metering. information associated with a KEDU. -When only one printer is selected to print, enter the sum of theprinter values 01,02,04, -Whenmore than one printer is selected to print, enter the value from Table 15.9A(e.g.,in this field must be Enter AL if the printer(s) can accept message meteringinformation associated with a KEDU. Printer Number associated with aKEDU. -When only one printer is selected to print, enter thesum of theprinter values01,02,04,-When more than one printer is selected to print, enter the value from Table 15.9A (e.g., for printer numbers 0 and 1, enter 3; for numbers 2 and 3, enter 12. -A printer number used in this field must be defined onRecord Code PD. will print this information. -ll;;ez entered, columns 23-24 cannot be 8187SW 5210
TL-130400-1001Table 15.96Entry Fields for Record Code AL (Continued)Indicate whether or not the printer(s) can accept message metering information associated with a KEDU. -When only one printer is selected to print, enter printer value 01, 02, 04, or 08. -When more than one printer is selected to print, enter the sum of the printer value (e.g., for printer numbers 0 and 1, enter 3; for numbers 2 and 3, enter 12). -A printernumber used in this field, must be will print this information. -lgl;ez entered, columns 27-28 cannot be -When more than one printer is selected to print, enter the sum of the printer values (e.g.,his field must be Enter AL if the printer(s) can accept message metering information associated with a KEDU. SVR 5210 8187D-299
TL-130400-1001 Table 15.98Entry Fields for Record Code AL (Continued) COL.NO. D-300 31-32 33-34 35-36 COL.NAME Message Waiting Printer Number, Identification Wake Up Function StatusVALID ENTRIES 01-l 5 = number -- = N/A AL = messagemetering information is to be printed -- = metering information is not to be printed 01-l 5 = number -- = N/A Wake Up Printer Number Identification 8187COMMENTS Indicate whehter or not the printer(s) can accept message metering information associated with a KEDU. -When only one printer is selected to print, enter printer value 01, 02, 04, or 08. -When more than one printer is selected to print, enter the sum of the printer values (e.g., for printer numbers 0 and 1, enter 3; for numbers 2 and 3, enter 12). -A printer number used in this field must be defined on Record Code PD. Enter AL if the printer(s) can accept message metering information associated with a KEDU. -Columns 35-36 indicate which printer(s) will print this information. -If AL is entered, columns 35-36 cannot be dashed. Indicate whether or not the printer(s) can accept message metering associated with a KEDU. -When only one printer is selected to print, enter printer value 01, 02, 04, or 08. -When more than one printer is selected to print, enter the sum of the printer values (e.g., for printer numbers 0 and 1, enter 3; for numbers 2 and 3, enter 12). -A printer number used in this field must be defined on Record Code PD. SVR 5210
TL-130400-1001Record Code WT: Ward Control15.10 Record Code WT, Figure 15.10, defines the ward groupings for the system. The beginning and ending times that the system will automatically impose the do not disturb feature are also defined. This feature provides quiet time for hospital patient rooms. A maximum of eight time periods can be used for up to 32 ward numbers. Time periods entered on this record code must not overlap one another (e.g.12:00-4:00, 5:01- 11 :OO). . . .T--------- r- r--- ---------___T---------------ITI------------------------~ I z!I I;I II I:I1I II I I :II I I WARD NUMBER(S)II I I I I I I I II I I I II I ~-+-~-u-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-~-+-+-+-+-+-+-+-+-+-+-+--l~413lOlWI TIOI I I I I I I I I I I I I I I I I I I I I I I I I I I I I A-J.-A- -L-L-~-~-I-~-I-*-~-I-*-~-1-1-~-~-~-1-*-~-1-1-~-~-~-*-J.-A.-A-*-AWARD NUMBER(S)I I I IIIIIII ; IIII-r--r--r-T-T-T-T-T-r-r-T-iI Figure 15.10 Record Code WT: Ward Control Data Sheet SW 52108187 D-301
TL-130400-1001Table 15.10Entry Fields for Record Code WT COL.COL.VALID NO.NAMEENTRIESCOMMENTS 12Time PeriodO-7 = numberThis field determines which time period this Numberfield is. Up to eight time periods are allowed. s--Each time period number must be unique..”13-14 ‘Y’ Begin Time by 00-23 = numberIndicate the hour that this feature, which Hourprevents rooms from being rung, goes into effect. 15-16Begin Time by00-59 = numberIndicate the minute of the hour that this feature Minutegoes into effect. 17-18End Time by 00-23 = numberIndicate the hour that the feature is no longer Hourin effect. 19-20End Time by 00-59 = numberIndicate the minute of the hour that this feature Minuteis no longer in effect. 21-52Ward NumberA = allowedEnter A if the time periods created in columns D = disallowed12-20 are in effect for this ward number. -Ward numbers are assigned to stations on Record Code LM, columns 32-33. -Ward control is assigned to attendants on Record Code AT, columns 39-40. -If allowed, the attendant can change these timing parameters from the console. NOTE: If a ward number is listed on Record Code LM, it must also be listed on this record code. D-3028187SVR 5210
TL-130400-1001 CENTRALIZED16.0 This section describes the record codes required to ANSWERINGdefine the various system CAS (Centralized Answering Service) SERVICEfeatures. The following record codes are required: BRANCH/MAIN l Record Code CF defines the system CAS Branch features. l Record Code AD defines the CAS Main agent position. l Record Code AF defines ACD recorder announcer access.Y..”. .SVR 5210l Record Code AG defines agent group characteristics. l Record Code DK defines repertory dial numbers. l Record Code RC defines RLT (Release Link Trunks) characteristics. l Record Code SM defines LCD (Liquid Crystal Display) messages. l Record Code SP defines supervisor messages. l Record Code TM defines supervisor repertory dial key. l Record Code RA defines CAS Main/ACD recorder announcers. l Record Code SD defines secondary directory numbers. $187D-303
TL-130400-1001Record Code CF:16.1 Record Code CF, Figure 16.1, defines the CAS Branch CAS Branch Featuresfeatures used by the system. -------------------------------------------------,I I I I 1114151ClFl I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I IL-*-*-~--~_I-~-~-~-~-i-~-~-~-*-~-~-~-~-~-~-~-~-~-~-~-*-~-~-~-*-~-~-~-~~-, Figure 16.1Record Code CF: CAS Branch Features Data Sheet D-3048187SVR 5210