Home > GTE > Communications System > GTE Omni Si Database Technical Practices Manual

GTE Omni Si Database Technical Practices Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GTE Omni Si Database Technical Practices Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 950
    							CPG ERROR
    MESSAGES
    TT-62l-l -01. . .Tl-02
    Tl-02Tl-02
    Tl-03
    Tl-03Tl-03
    Tl -04
    Tl-04SVR 5210TL-130400-1001
    Table 21.1
    CPG Error Messages (Continued)
    TITLEESP CAN BE 
    ‘Y’FOR ONLY ONE
    PORT
    .~.SECOND
    ELEMENT LESS
    l-HEN FIRST
    ELEMENT
    ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    2ND FEATURE
    REQUIRED IF
    FIRST
    SPECIFIED
    ELEMENT HAVE
    NCOMPATIBLE
    dALUESELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    2ND FEATURE
    REQUIRED IF
    FIRST
    SPECIFIED
    ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATIONDESCRIPTION OF MESSAGES
    ESP
    ONLY ONE PORT CAN BE DESIGNATED AS THE ESP
    PORT.TRUNK GROUP -ALTERNATE TRUNK GROUP
    THESE TRUNK GROUP NUMBERS CANNOT BE EQUAL.
    TRUNK APPLICATION 
    - DISPLAYABLE CLASS OF
    SERVICE, N-DISPLAYABLE CLASS OF SERVICE
    A CLASS OF SERVICE IS MEANINGFUL ONLY WHEN
    THE TRUNK APPLICATION IS ‘TIE’, ‘COT’, ‘FXT’, OR
    ‘WTS’, AND THE TRUNK DIRECTION IS ‘IN’ (INCOMING)
    OR ‘TW’ (TWO-WAY).
    THE CLASS OR SERVICE FIELDS FOR THESE TRUNK
    APPLICATIONS, HOWEVER, CAN BE DASHED.
    TRUNK APPLICATION ‘NIC’ MUST HAVE CLASS OF
    SERVICE DATA.
    TRUNK APPLICATION 
    - TIE TRUNK CALLING NUMBER
    A TIE TRUNK CALLING NUMBER IS MEANINGFUL ONLY
    WHEN THE TRUNK APPLICATION IS ‘TIE’.
    THE TIE TRUNK CALLING NUMBER, HOWEVER, CAN
    BE DASHED.
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    8187D-535 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    Tl-04
    . . .2ND FEATURETRUNK APPLICATION 
    - TRUNK DIRECTION - ACD
    REQUIRED IF
    TRUNK PILOT NUMBER
    FIRST
    ACD TRUNK PILOT NUMBER CAN BE USED WITH ANY
    SPECIFIEDTRUNK APPLICATION IF THE TRUNK DIRECTION IS
    INCOMING OR TWO-WAY.
    THE FOLLOWING IS A LIST OF REQUIREMENTS:
    TRUNK ACD
    TRUNK
    APPLICATIONDIRECTION PILOT NUMBER
    CAS,CLR,COT,FXT, IN,TW0000-9999TIE OR WTS
    DIC,PAG,REC,NIC --
    CAS,CLR,COT,OG,TW ::::
    FXT,TIE,OR VVTSTl-05ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    Tl-05ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-052ND FEATUREACD TRUNK PILOT NUMBER - TRUNK INCOMING
    REQUIRED IFSIGNAL
    FIRSTAN ACD TRUNK PILOT NUMBER CAN BE SPECIFIED
    SPECIFIEDONLY IF THE INCOMING SIGNALING FIELDS ARE
    DASHED.
    Tl-06INVALID
    TRUNK INCOMING SIGNAL
    CHARACTER(RETURN DIAL TONE 
    - RETURN DISTINCTIVE DIAL
    PATTERN INTONE)
    2ND FIELD
    ONE OR THE OTHER OF THESE FIELDS CAN BE
    SPECIFIED (‘Y’), BUT NOT BOTH.
    Tl-08ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-08ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    D-5368187SVR 5210 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)PG ERROR
    IESSAGESTITLEDESCRIPTION OF MESSAGES
    Tl-082ND FEATUREBILLING MODE 
    - TRUNK OUTGOING SIGNAL (MF)
    REQUIRED IFMF SIGNALING APPLIES ONLY TO 
    CAMA BILLING
    ‘- FIRST
    MODE.
    -..SPECIFIEDTHUS, IF THE BILLING MODE IS SPECIFIED AS ‘CM’,
    THEN THE MF OUTGOING SIGNAL FIELD MUST BE ‘Y’.
    THE MF OUTGOING SIGNAL FIELD FOR ALL OTHER
    ,.BILLING MODE SPECIFICATIONS MUST BE DASHED.
    Tl-09ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-09ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    Tl-092ND FEATUREBILLING MODE 
    - TRUNK DIRECTION
    REQUIRED IFWHEN THE BILLING MODE IS ‘CM’ 
    (CAMA), THE TRUNK
    FIRSTDIRECTION MUST BE ‘OG’ (OUTGOING ONLY).
    SPECIFIED
    Tl-10ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    Tl-10
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-10
    Tl-112ND FEATUREBILLING MODE 
    - AIOD CHANNEL
    REQUIRED IF
    FIRSTVALUE OFALLOWABLE VALUE OF
    SPECIFIEDBILLING MODE
    AIOD CHANNEL
    CM OR --
    Al
    1,2,3,4ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    Tl-11
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    SVR 5210
    8187D-537 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    Tl-112ND FEATURE
    TRUNK DIRECTION 
    -REQUIRED IF
    DISPLAYABLE CLASS OF SERVICE,
    FIRSTN-DISPLAYABLE CLASS OF SERVICE
    SPECIFIEDCLASS OF SERVICE MUST BE DASHES FOR TRUNK
    . . .DIRECTION OF ‘OG’.
    Tl-12 _ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    Tl-12ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-122ND FEATURE
    TRUNK DIRECTION-TRUNK INCOMING SIGNAL-REQUIRED IF
    TRUNK OUTGOING SIGNAL
    FIRST
    SPECIFIEDIF THE TRUNK DIRECTION IS ‘OG’ (OUTGOING ONLY),
    THEN THE TRUNK OUTGOING SIGNALING FIELDS
    MUST BE NONDASHED,
    AND THE TRUNK INCOMING SIGNALING FIELDS MUST
    BE DASHED.
    IF THE TRUNK DIRECTION IS ‘IN’ (INCOMING ONLY),
    THEN THE TRUNK INCOMING SIGNALING FIELDS
    MUST BE NONDASHED,
    AND THE TRUNK OUTGOING SIGNALING FIELDS MUST
    BE DASHED.
    IF THE TRUNK DIRECTION IS ‘TW’ (TWO WAY),
    THEN THE TRUNK INCOMING SIGNALING FIELDS
    MUST BE NONDASHED,
    AND THE OUTGOING SIGNALING FIELDS MUST BE
    NONDASHED.
    Tl-13
    INVALIDMISSING DID DIGITS
    CHARACTERIF DIGIT 1 IS DASHED, THEN DIGIT 2 MUST BE
    PATTERN IN
    DASHED.
    2ND FIELD
    Tl-14
    ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    Tl-14
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    D-5388187SVR 5210 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    Tl-142ND FEATURE
    TRUNK APPLICATION 
    - DISCONNECT SUPERVISION
    REQUIRED IF
    IF THE TRUNK APPLICATION IS ‘TIE’,
    F.!!RSTTHEN DISCONNECT SUPERVISION MUST BE ‘BT’.
    SPECIFIED
    . . .
    Tl-16DASHES MUSTTIE TRUNK CALLING NUMBER
    BE USED
    DASHES MUST BE USED CONSISTENTLY.
    CONSISTENTLY
    IN FIELD
    Tl-17
    DASHES MUSTACD PILOT NUMBER
    BE USEDDASHES MUST BE USED CONSISTENTLY.
    CONSISTENTLY
    IN FIELD
    Tl-20
    ILLEGAL VALUE TRUNK APPLICATION
    FOR TRUNK
    THE FOLLOWING FIELDS MUST HAVE CERTAIN
    APPLICATIONREQUIRED VALUES IF TRUNK APPLICATION IS 
    ‘DIG’,‘PAG’, ‘REC’ OR ‘NIC’:
    FIELD NAME
    REQUIRED
    VALUE
    TRUNK DIRECTION
    --TRUNK INCOMING SIGNAL
    ----TRUNK OUTGOING SIGNAL
    ----TRUNK DISCONNECT SUPERVISION --
    BILLING MODE
    --ALTERNATE TRUNK GROUP
    --TRUNK TRANSFER ALLOWED
    -TIE TRUNK CALLING NUMBER
    ----
    AIOD CHANNEL
    MISSING DID DIGITS 1 
    & 2--ACD TRUNK PILOT NUMBER
    ----ACD TRANSLATION INDICATOR
    --ROUTE TO RLT
    ANSWER BACK R/A
    ACA
    OUTGOING TRUNK
    GROUP FRL TO ACCESS
    Tl-21ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUE
    Tl-21ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    SVR 5210
    8187D-539 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    Tl-212ND FEATURE
    REQUIRED IF
    FIRST
    SPECIFIED
    Tl-21RECORDER
    TRUNK APPLICATION 
    - R/A RETURN ANSWER BACK
    ANNOUNCERTHE R/A RETURN ANSWER BACK FIELD CAN BE
    NOT ALLOWEDSPECIFIED (‘Y’) ONLY IF THE TRUNK APPLICATION IS
    FOR TRUNK
    ‘REC.APPLICATION
    Tl-22Tl-23MF CAMA ONLYCAS TRUNK APPLICATION - TRUNK OUTGOING
    IS NOTSIGNAL
    ALLOWED FOR
    FOR TRUNK APPLICATION, ‘CAS’, OUTGOING SIGNAL
    TRK APPL CASMF 
    (CAMA ONLY) IS NOT ALLOWED.
    AGENT GROUPTRUNK APPLICATION 
    - AGENT GROUP NUMBER
    # MUST BE
    FOR TRUNK APPLICATION, ‘CAS’, AN AGENT GROUP
    SPECIFIED FORNUMBER MUST BE SPECIFIED.
    TRUNK
    APPLICATION
    CAS
    Tl-24SECOND
    TRUNK DIRECTION 
    - TRUNK HOMING SELECTION
    ELEMENTIF TRUNK HOMING SELECTION IS SPECIFIED,
    CONTAINS
    THE TRUNK DIRECTION MUST BE ‘OG’ OR ‘TW’.
    INVALID VALUE
    Tl-25ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-25ELEMENT 2 IS
    ACA 
    - ACA TOLERANCES
    MEANINGLESSIF THE ACA FIELD IS 
    ‘Y’, THEN THE ACA TOLERANCE
    SPECIFICATIONFIELDS (ACA SHORT CALL THRESHOLD, INTERVAL,
    AND THE LONG CALL INTERVAL) MUST BE NOT BE
    DASHED.
    Tl-26
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    Tl-26
    ELEMENT 2 ISOUTGOING TRUNK GROUP FRL OUTPULSED 
    - TRUNK
    MEANINGLESS
    DIRECTION
    SPECIFICATIONIF THE OUTGOING TRUNK GROUP FRL OUTPULSED IS
    ‘Y’, THEN THE TRUNK DIRECTION MUST BE ‘OG’ OR
    ‘TW’.
    D-5408l87SVR 5210 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)
    DESCRIPTION OF MESSAGESINCOMPATIBLE
    THEN THE TRUNK DIRECTION MUST BE
    MEANINGLESS
    OING TRUNK GROUP FRL TO ACCESS IS
    HEN THE TRUNK DIRECTION MUST BE
    MEANINGLESS
    INCOMPATIBLE
    BER MUST BE UNIQUE
    DD RECORD.LASSES OF SERVICE SELECTED
    ROUP MUST BE INITIALIZED BY A
    THE N-DISPLAYABLE CLASSES OF SERVICE
    SELECTED FOR EACH TRUNK GROUP MUST BE
    INITIALIZED BY AN NC RECORD.
    REQUIREMENT PATTERNS OF
    -DISPLAYABLE CLASSES OF
    SERVICE FEATURESSEE APPENDIX 1.
    UIT SHOULD BE DEFINED ON THE FR
    SVR 52108187D-541 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    Tl-57
    Tl-59Tl-60INVALIDALTERNATE TRUNK GROUP
    ALTERNATE
    THE ALTERNATE TRUNK GROUP MUST BE DEFINED
    TRUNK GROUPAS A TRUNK GROUP ON A 
    Tl AND T2 RECORD.i(ENDCHK)
    PILOT NO.IN ORDER FOR THE ACD FEATURE TO WORK
    BELONGS TOPROPERLY, IT IS MORE DESIRABLE TO USE A PILOT
    TERMINAL
    NUMBER FROM A CIRCULAR HUNT GROUP.
    HUNT GRP 
    ‘o(GENTRK)
    INVALID PILOTTHE ACD PILOT NUMBER SHOULD BE A VALID PILOT
    NUMBER
    NUMBER ON AN HG RECORD, AN ATTENDANT
    CALLING NUMBER ON AN AT OR CN RECORD, OR A
    STATION NUMBER ON AN LD RECORD.
    (GENTRK)
    Tl-61TRUNK GROUPTRUNK GROUP NUMBER
    ACCESS ERROREACH TRUNK GROUP SHOULD BE MARKED FOR
    TRUNK GROUP ACCESS ON A DC RECORD IF THE
    TRUNK GROUP DIRECTION IS OUTGOING OR 
    TWO-WAY.
    (ENDCHK)
    Tl-62CLASS OFTRUNK GROUP - DISPLAYABLE CLASS OF SERVICE
    SERVICE NOTCONFLICTS
    ALLOWEDAN INCOMING TRUNK GROUP IS RESTRICTED FROM
    HAVING CERTAIN FEATURES. THE FOLLOWING ARE
    THE ONLY FEATURES ALLOWED FOR TRUNK GROUPS
    WITH AN APPLICATION TYPE OF ‘COT’, ‘FXT’, OR
    ‘WTS’:
    1. TRUNK GROUP ACCESS
    2. DICTATION EQUIPMENT ACCESS (‘DA’)
    3. STATION ACCESS (‘SA’)
    4. RLT ACCESS (‘RL’)
    THE FOLLOWING ARE THE ONLY FEATURES
    RESTRICTED FROM ‘TIE’ TRUNK APPLICATION TRUNK
    GROUPS:
    1. SWITCHED DIRECT LINE (‘SL’)
    2. PROGRESSIVE CONFERENCE (‘PC’)
    D-542
    8187SVR 5210 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)
    DESCRIPTION OF MESSAGESSERVICE NOT
    ANINCOMING TRUNK GROUP
    ISRESTRICTEDFROM
    HAVING CERTAIN FEATURES.
    THE FOLLOWING ARE THE ONLY FEATURES ALLOWED
    FOR TRUNK GROUPS WITH AN APPLICATION TYPE OF
    ‘COT’ OR ‘FXT’:
    1. ATTENDANT INFORMATION (‘Al’)
    2. DATA LINE SECURITY 
    (‘OS’)3. UNIVERSAL NIGHT ANSWER (‘UN’)
    4. COMPUTER ACCESS (‘CA’)
    THE FOLLOWING ARE THE ONLY FEATURES ALLOWED
    FOR ‘WTS’ TRUNK APPLICATION TRUNK GROUPS:
    1. DATA LINE SECURITY 
    (IDS’)ALLOWED FOR
    ‘TIE’ TRUNK APPLICATIONTRUNK
    1. ATTENDANT INFORMATION (‘Al’)
    2. DATA LINE SECURITY (‘DS’)
    3. UNIVERSAL NIGHT ANSWER (‘UN’)
    4. COMPUTER ACCESS (‘CA’)
    FOR TRUNK APPLICATION,‘CAS’,STATION ACCESS
    IS
    REQUIRED IN THE TRUNK GROUP’S DISPLAYABLE
    CLASS OF SERVICE.
    THE FOLLOWING FEATURES ARE NOT ALLOWED IN
    THE TRUNK GROUP’S DISPLAYABLE CLASS OF
    SERVICE:
    1. SWITCHED DIRECT LINE (‘SL’)
    2. MODEM ACCESS (‘MD’)
    SVR 5210
    $I87D-543 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
    THEN THE ASSOCIATED N-DISPLAYABLE CLASS OF
    SERVICE MUST NOT BE MARKEDFOR SPEED
    FOUND ON A 
    Tl RECORD.
    THE 
    TRU’NK GROUP SPECIFIED AS THE IDENTIFIER
    MUST BE DEFINED ON A 
    TlRECORD.
    BE ‘DIC’, ‘PAG’, ‘REC, OR ‘NIC’ FOR THE TRUNK
    GROUP SPECIFIEDFOR VMS ANDMDUDIRECTORY
    ON RECORD
    FRL TO ACCESS MUST THEREFORE BE SPECIFIED
    FOR EVERY OUTGOING OR TWO-WAY TRUNK GROUP
    ON RECORD CODE Tl.
    Tl-72INCONSISTENTFRLS HAVE BEEN SPECIFIED FOR SOME PARTS OF
    ENGINEERINGTHE SYSTEM AND NOT OTHERS.
    OF FRLSENSURE THAT ALL ATTENDANTS, LINES, TRUNK
    GROUPS, MERS ROUTES, ETC. HAVE FRLS ENTIRELY
    ENABLED OR DISABLED.
    IN THE CASE OF TRUNK GROUPS, ALL OUTGOING OR
    TWO-WAY TRUNK GROUPS REQUIRE OUTGOING FRL
    TO ACCESS TO BE CONSISTENTLY ENGINEERED.
    D-544
    8187SVR 5210 
    						
    All GTE manuals Comments (0)