GTE Omni Si Database Technical Practices Manual
Have a look at the manual GTE Omni Si Database Technical Practices Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
TL-130400-1001Table 3.1Entry Fields for Record Code FWCOMMENTS -The field varies from card type to card type, and not all card types require an entry. -Refer to the extended card list that follows this table to determine whether or not a primary identifier is required, and to determine what the allowable entries are. -The fieldvaries fromcard type to card type, and not all card types require an entry. -Refer to the extended card list that follows this table to determine whether or not a secondary identifier is required, and to determine what theallowableentriesare. varies fromcardtype tocard type, and not all card types require an entry. -Refer to the extended card list that follows this table to determine whether or not a
TL-130400-1001COL.NO. Table 3.1Entry Fields for Record Code FR (Continued) COL.VALID NAME ENTRIESCOMMENTS 32-39Card FB-This field entry isThis field determines the FB number of the Numberthe FB number ofcard type listed in columns 16-l 9: the card. Voice cards:-See commentsAGNT = FB-17209 -2following TableAIOD = FB-17276.j ,”3.1.ART = FB-17208 -.Any ASCIIATTN = FB-17208 characters areCIP = FB-17225 allowed.CONF = FB-51279 . .COT = FB-17202 DTMF = FB-17203 DTMl = FB-17203 DTRK = FB-15278, FB-15280, FB-17277 or FB-15277, FB-20718 or FB-17192 DVC = FB-17236 EMT = FB-17201 EMT4 = FB-51267 ERLT = FB-17251FP = FB-17254 FPOP = FB-17250 ILT = FB-51280 KEDU = FB-17209 OFFP = FB-17250 OPI = TR-100119 PDIC = FB-17210 POTS = FB-17254 RLT = FB-17251SM = FB-51279 TDET = FB-17280 VCIP = FB-17235 Data cards:ADMP(-A) = FB-17229 and ADMP(-C) = FB-17230 BT = FB-17227 DCP = FB-17231DCPB = FB-17231 NIC = FB-17242 PBE = FB-17227 PR = FB-4 7228 VP20 = FB-17246 VP21 = FB-17246 VPLO = FB-17226 VPLl = FB-17226 NOTE: FB numbers are repeated for different card types, because the same card can be used for different applications. The card types identify the various uses of the cards. D-28
COL.NO. Table 3.1Entry Fields for Record Code FW (Continued)COMMENTS This field determines whether or not a card is used for AlOD,ART, or CONF cards.allother card types are dashed. In service conditions for other NOTES: ~.1. The tables in which the physical location information is stored depend on the card type. For tables initialized, see Note 2. The physical location is used as an index into Table T6566. 2. The maximum number of records is 41. 3.PD-200 cards are in bold print (see Table 3.6 for system maximum). 4. The specification of Tl spans on Record Code FR requires some explanation. The actual printed circuit boards that make up a Tl span in the OMNI SI consist of FB-17192 (Tl B2), FB-20718 (TlS), FB-17277 (SIL), FB-15280 (LCM), and FB-15278 (FDC). These double-width cards are placed in physical card slots C6/XlO, C5IX12, C4/X14, C3/X16, C2/X18 of the Expansion File. None of these card slots corresponds to a universal card slot. An X denotes slots with no connection to the backplane. The DTRK (Digital Trunk) card types specified on Record Code FR reserve the universal card slots that correspond to the hardware addresses used by the Tl span. Each universal card slot represents four Tl channels. A total of six universal card slots represent the entire Tl span (COl-CO6 for the OMNI SI). The last 3 universal card slots representing a Tl span may be used for cards types other than DTRK card types if the full 24 Tl channel capability is not required. 5.Several card types in the following list of cards are referred to by relative controlling card number and relative line card number. The following information explains how these numbers are derived. @ Relative controlling card number is derived from tables T7053-X(where X =PEC number). Each table contains 16 bytes which are numbered 0 to 15. When assigning a relative controlling card number, select an unused entry from one of these tables. e Relative line card number is derived from T2541, 12551, 12561, T2571, T25A1, T2581, T25C4, or T25D1, depending on the PEC number. Each table contains 32 bytes which are numbered O-31. When assigning a relative line card number, select an unused entry from one of these tables.
TL-130400-1001 Valid card types are as follows: ADMP*-AGNT.j * AIODART ATTN BT CIPCONF COT DCPDenotes the data system administrative processor cards (one set maximum). The primary identifier is the ADMP number - 0000. The secondary identifier is the ADMP card number - 0000 (ADMP-A) to 0001 (ADMP-C). The tertiary identifier is the controlling UCBIDCP number 0000-0009. Entries are made in T6563, T705A, and T6566. Denotes the agent Programmable Attendant Console Electronic Telephone (PACET) data link card (32 maximum). No identifiers are required. Denotes the AIOD card (1 maximum). Entries are made in T6111, T6131, and T2701. No identifiers are required. Denotes asynchronous receiver/transmitter cards (3 maximum). The primary identifier is ART card type - 0009, 0010, or 0011. No other identifier is required. Entries are made in T6111, T6134, T6394, and T639B. Unless the FB-17208-BO card is used, the card may overhang into the next slot. Denotes attendant BLDU card (3 maximum). No identifiers are required. Unless the FB-17208-BO card is used, the card may overhang into the next slot. Denotes bus terminator card (for local packet buses associated with packet routers and packet bus extender cards). The primary identifier is packet router number - 0000 to 0001. The secondary identifier is local packet bus/ bus segment combination - 0000 to 0003 is local packet bus 0, bus segments 0 to 3; 0004 to 0007 is local packet bus 1, bus segments 0 to 3. Entries are made in T6562 and T6567. See Table 3.6 for maximum cards allowed. Denotes Featurephone data link card (16 maximum of all Featurephone/Digital Phone data link cards). The primary identifier is relative controlling card number - 0000 to 0015 (see Note 5). No other identifier is required. Entries are made in T7053-0 and T7057-0.Denotes conference card (2 maximum). The primary identifier is conference circuit number - 0000 to 0001. No other identifier is required. Entries are made in T6111, T6131, T2741, and T2742. Denotes CO trunk card (16 maximum of all trunk cards). No other identifier is required. Denotes data device controlling data UCB card (4 maximum with this SVR). The primary identifier is DCP number - 0000. No other identifier is required. Entries are made in T6565.
DCPB DTMFx-DTRK DVC‘.EMT EMT4 ERLT FPFPOP ILT KEDU NICTL-130400-1001 Denotes data device controlling data UCB card with a bus terminator (4 maximum). The primary identifier is DCP number -0000 to 0003. The secondary identifier is packet router number -0000 to 0004. The tertiary identifier is the LPB (Local Packet Bus) bus segment. Entries are made in T6562 and T6567. Denotes DTMF receiver card with four circuits (8 maximum). No identifiers are required. Denotes digital trunk card (Tl spans). The engineering of digital trunks requires that physical locations corresponding to the hardware addresses used for Tl spans be specified (6 maximum). No identifiers are required. Denotes data voice control interface processor card (16 maximum of all FeaturephoneIDigital Phone data link cards, 32 maximum of all line cards). The primary identifier is relative line card number -0000 to 0031; the secondary identifier is relative controlling card number - 0000 to 0015 (see Note 5). No other identifier is required. Entries are made in T2541, T6561, T7053-0, and T7057-0.Denotes 2-wire E&M trunk card (23 maximum of all trunk cards). No identifiers are required. Denotes 4-wire E&M trunk card (23 maximum of all trunk cards). No identifiers are required. (Cable pairs listing must show second cable.) Denotes E&M trunk card used as release link trunk card (4 maximum). No identifiers are required. Denotes Featurephone line card (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). No other identifier is required. Entries are made in T2541 and T6561. Denotes Featurephone off-premises line card (16 maximum of all line cards). The primary identifier is relative line card number -0000 to 0031 (see Note 5). No other identifier is required. Entries are made in T2541 and T6.561.Denotes incoming loop trunk card (23 maximum of all trunk cards). No identifiers are required. Denotes KEDU/printer card (2 maximum). No identifiers are required. Denotes network interface card (16 maximum). The primary identifier is controlling DCP number (0000 this SVR). No other identifier is required. Entries are made in T6566.
TL-130400-1001 OFFPOPIPBE *.1 * PDICPOTS PRRLT SM TDET VCIPVP20Denotes off-premises line card (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). No other identifier is required. Entries are made in T2541 and T6561.Denotes the OMNI PMS interface card (1 maximum). No identifiers are required. Denotes packet bus extender card (2 maximum). The primary identifier is packet router number - 0000 to 0001. No other identifier is required. Entries are made in T6562 and T6567. Denotes paging and dictation trunk card (23 maximum of all trunk cards). No identifiers are required. . Denotes regular line card (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). No other identifier is required. Entries are made in T2541 and T6561. Denotes packet router card (2 maximum with this SW). The primary identifier is packet router number - 0000 to 0001. No other identifier is required. Entries are made in T6562 and T7058-0.Denotes release link trunk card (4 maximum). No identifiers are required. Denotes silent monitor card (8 maximum). The primary identifier is silent monitor card number - 0000 to 0007. No other identifier is required. Entries are made in T5344. Denotes SCC tone detector card (8 maximum). No identifiers are required. Denotes voice control interface processor card (16 maximum of all Featurephone/Digital Phone data link cards (16 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). The secondary identifier is relative controlling card number - 0000 to 0015 (see Note 5). No other identifier is required. Entries are made in T2541, T7053-0, and T7057-0.Denotes Voice Packet Line Cards VPLC Mark 2 or VPLC2, type 0, eight circuit (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). The secondary identifier depends on card usage as follows: 0 Voice only - relative controller card number 0000 to 0015 (see Note 5) 0 Voice and data - relative controller card number 0000 to 0015 (see Note 5)
TL-130400-10010 Data only - always ---- The tertiary identifier depends on card usage as follows: 0 Voice only - always 0000 0 Voice and data - always 0001 l Data only - always ---- 5..I *Entries are made in T2541, T6561, T7053-0, and T7057. VP21Denotes VPLC2, type 1, two circuit (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 ‘- (see Note 5). No other identifier is required. Entries are made in T2541 and T6561. VPLODenotes VPLC, type 0, eight circuit (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). No other identifier is required. Entries are made in T2541 and T6564. VPLlDenotes VPLC, type 1, two circuit (32 maximum of all line cards). The primary identifier is relative line card number - 0000 to 0031 (see Note 5). No other identifier is required. Entries are made in T2541 and T6561.Table 3.2 FR Rules._- ._._ -.-- -- ---_--=R-01 CARD TYPE - PRIMARY, SECONDARY, AND TERTIARY IDENTIFIERS Consult Table 3.3, Card Types Versus Identifiers and Status, to determine approximate values to specify for each particular card type. This table specifies the valid ranges of the three identifiers and the status given a particular card type. FR-02 CARD TYPE - PHYSICAL LOCATION If the card type is DTRK, then the group field must be C since Tl spans can only be installed in this group. Specific card placement restrictions are in effect for the following card types: . BT. PBE . DCPB . PR These cards can only be placed in the following group/slots: . AOO, AlO, BOO, B09@COO, CO9, DOO, DO1 , DlOFR-50 CARD TYPE - PEC - PRIMARY, SECONDARY, TERTIARY IDENTIFIERS Consult Table 3.4, Card Types Versus Identifiers Checks, to determine the appropriate values to specify for each particular card type. The table shows the meaning of the primary, secondary, and tertiary identifiers on the FR record and checks that are applicable for each set of card types. Also shown is Table 3.5, Card Types Versus Card Slot Restriction.
TL-130400-1001Table 3.2 FR Rules (Continued)FR-51 PHYSICAL LOCATION eThe PEC, group, and slot specified for this card must be unique. PEG always = 0. lThe DTRK cards must always be assigned from the lowest to the highest slot number without any other type of card residing between the DTRK cards. eNo other type of card can reside in one of the slots required to implement the Tl span which is implied by the input of a DTRK card. @The-PEC, group, and slot specified must be valid for the PEC type. PEC always = 0. @A previous FR-record cannot define a wide card which overhangs into a specified slot. eThe card type specified must not be assigned a physical location to which it is not allowed. FR-52 PHYSICAL LOCATION The PEC, group, and slot specified for a card must be unique. PEC always = 0. FR-53 CARD TYPE The data system card types (ADMP, BT, DCP, DCPB, NIC, PR, PBE, VPLO, VPLl, VP20 and VP21) are only allowed in systems with the PD-200 Data Option. FR-56 LOCAL PACKET BUS The minimum local packet bus configuration is a packet router (card type PR) and a bus , terminator (card types BT and DCPB) in the primary file (bus 0). A second local packet bus may be added by using a packet bus extender (card type PBE). If the second file is used (bus l), it must contain a bus extender card and terminator card. FR-57 LOCAL PACKET BUS All data cards must be placed on a local packet bus segment. The ends of a local packet bus segment are defined by the placement of PR, PBE, and bus terminator cards. All data cards must be placed between a PR or PBE and a bus terminator. FR-59 DATA SYSTEM CARD TYPES If the data option is specified on Record Code OE, then at least one each of the following cards must be defined: 0 ADMP 0 PR 0 BT (DCPB) FR-60 CARD TYPE - PRIMARY IDENTIFIER The primary index for SM (Silent Monitor) cards must be continuous (i.e., the SM card numbers must be assigned from 0 to 7 corresponding to the number of SM cards 1 to 8).
TL-130400-1001Table 3.2FR Rules (Continued) FR-61 PHYSICAL LOCATIONIf a controlling DCP (UCB) number is used as the primary identifier for a NfC card, the same number must be used as the primary identifier on a DCP or DCPB card. FR-62 EXPANSION FILE STATUSIf group C or D is listed in the physical location, Expansion File status on record code OE must be ma&d equipped. Table 3.3Card Types Versus Identifiers and StatusVALUE OFALLOWABLE PRIMARY ALLOWABLE SECONDARY CARD TYPEIDENTIFIER RANGEIDENTIFIER RANGE ADMP AGNT AIOD ART ATTN---- BT0000-0001 CIP 0000-0015 CONF 0000-0001 COT ---- DCP 0000-0003 DCPB0000-0003 DTMF ---- DTRK---- DVC 0000-0031 EMT ---- EMT4---- EMT---- FP 0000-0031 FPOP0000-00310000-0001 ---- 0000 or 0004 we-- 0000-0001 -w-eALLOWABLE TERTIARY IDEN- TIFIER RANGESTATUS FIELD ---- ----IS, OS 0000 or 0004 0000-0015 -- ILT---_ ---- -w-w
TL-130400-1001Table 3.3Card Types Versus Identifiers and Status (Continued) VALUE OF ALLOWABLE PRIMARY ALLOWABLE SECONDARYALLOWABLE CARD TYPESTATUS IDENTIFIER RANGE IDENTIFIER RANGETERTIARY IDEN- TIFIER RANGEFIELDKEDU ---____--___-- -NC0000-0003__---_---- WFP.--Tl ~0000-0031____------ OPi-----_--_----_PBE ._oooo-ooqj-______-__ PDIC--__-----___--POTS 0000-0031----_____- PR0000-0001-___------RLT ----_____--- -- SM0000-0007_-__-_---_TDET -----_--___--_ VCIP0000-00310000-0015_--_--VP20 0000-00310000-00150000-0001--or --__or ____ VP210000-0031----___--- VPLO0000-0031_-----_- -- VPLl0000-0031__--------