    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    CP-53USE OF
    DEVICE TYPE 
    - PHYSICAL LOCATION THE PEC,
    PHYSICAL LOCGROUP, SLOT AND CIRCUIT OF SOME DATA PORTS
    CONFLICTSMUST BE DEFINED ON AN LD RECORD.
    -rWITHDEVICE TYPE TERM MUST APPEAR ON AN LD
    -..INSTRUMENTRECORD WITH INSTRUMENT TYPE ‘DFPA’ OR ‘APM’.
    TYPE SPECIFIED DEVICE TYPE HOST MUST APPEAR ON AN LD
    ON LDRECORD WITH
    .-INSTRUMENT TYPE ‘DFPA’ OR ‘APM’.
    DEVICE TYPE X25 MUST APPEAR ON AN LD RECORD
    WITH INSTRUMENT TYPE ‘SPM’.
    DEVICE TYPE NIC MUST APPEAR ON A TC RECORD
    AS A MEMBER OF A NIC TRUNK GROUP.
    CP-54
    CP-55DUPLICATEPHYSICAL LOCATION
    PHYSICALTHE PEC, GROUP, SLOT, AND CIRCUIT SPECIFIED
    LOCATIONMUST BE UNIQUE ACROSS ALL CP RECORDS.
    X.121 ADDRESS X.121 ADDRESS
    NOT IN ROTARYAN ASYNCHRONOUS PORT (DEVICE TYPE OF ‘TERM’
    OR ‘HOST’) MUST BE PART OF AN ASYNCHRONOUS
    GROUP
    (ORDER ROTARY, 
    ORdER DIRECT, RANDOM ROTARY,
    RANDOM DIRECT) DEFINED ON AN RT RECORD.
    (TABGENIGENDAT)CP-57
    MPR MUST BEADMP OR MDR FIELD
    SPECIFIED ONIF THIS DATA PORT IS SPECIFIED AS INTERFACING TO
    RECORD CODETHE MDR PROCESSOR THEN MDR MUST BE
    OE AND 
    PlEQUIPPED ON THE OE RECORD.
    THE MDR FIELD ON SYSTEM START-UP (MDR
    EQUIPPED) MUST BE 
    ‘Y’ ON THE Pl RECORD.
    CP-58ONLY ONE MDRADMP OR MDR FIELD
    AND ONE ADMPTHE DATA PORT INTERFACING TO THE MDR
    X.121 ADDRESSPROCESSOR AND THE PSEUDO DATA PORT
    MAY BEINTERFACING TO THE ADMP MUST BE UNIQUE.
    SPECIFIED
    CP-59AN ADMP CARDADMP OR MDR FIELD
    MUST BEIF THIS DATA PORT IS SPECIFIED AS INTERFACING TO
    DEFINED ONTHE PSEUDO DATA PORT, THEN AN ADMP CARD
    RECORD CODEMUST BE DEFINED ON AN FR RECORD.
    FR(ADMPCK)
    SVR 5210
    8187D-445 
    						
    							TL-130400-1001D-446
    Table 21.1CPG Error Messages (Continued)DESCRIPTIONOF MESSAGES
    PORTS DEFINED
    ESS SPECIFIED MUST BE UNIQUE
    ACROSS ALL CP RECORD. IN ADDITION,
    THERE MUST BE NO CONFLICT BETWEEN THE
    TWELVE NUMERIC DIGIT X.121 ADDRESSES FOR
    SYNCHRONOUS DATA PORTS (DEVICE TYPES ‘X25’,
    ‘NIC’ AND ‘PX25’) AND THE FOURTEEN NUMERIC DIGIT
    X.121 ADDRESSES FOR ASYNCHRONOUS DATA
    PORTS (DEVICE TYPES ‘TERM’ AND‘HOST’)
    EN ROTARY MUST HAVE THE
    DCP SPECIFIED ON RECORD
    NED ON RECORD CODE FR
    SPECIFIED IN ADMP OR
    (ADMPCK)
    CP-82PHYSICALPHYSICAL LOCATION
    LOCATION ISEVERY DATA PORT APPEARING ON AN LD RECORD
    MISSING ONMUST ALSO APPEAR ON A CP RECORD. EVERY NIC
    NAMEDAPPEARING ON A TC RECORD MUST APPEAR ON A CP
    RECORD CODE RECORD. (ENDCHK)
    CR-01ENTRYAN ENTRY INTO THE CODE RESTRICTION TABLES
    ATTEMPTED INHAD BEEN ATTEMPTED, BUT THAT LOCATION AND BIT
    NONVACANTPOSITION WAS ALREADY FULL. THE ENTRY WAS NOT
    LOCATIONMADE. CHECK THE THREE DIGIT 
    NPA/ABC CODE
    NUMBER IN THE DESIGNATED COLUMN AGAINST
    CODES PREVIOUSLY ENTERED IN THAT CODE
    RESTRICTION TABLE FOR A DUPLICATION.
    (TABGEN/GENDIG)
    8187SVR 5210 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    CR-02INVALIDAN INVALID SEQUENCE OF 
    NPA/ABC CODES HAD
    SEQUENCEBEEN SPECIFIED TO BE ENTERED.
    Y-NO ENTRIES WERE MADE.
    -..CHECK THE SEQUENCE CONTAINING THE
    DESIGNATED COLUMN FOR A LOWER BOUND LESS
    THAN OR EQUAL TO THE UPPER BOUND.
    (TABGEN/GENDIG)
    CR-03
    IMPRObERTHE CPG HAS DETERMINED THAT THE FIRST
    STARTING
    NPA/ABC CODE LISTED ON THE CODE RESTRICTION
    COLUMNRECORD IS NOT IN THE PROPER COLUMNS.
    PROPER TABLE GENERATION IS NOT GUARANTEED.
    (TABGEN/GENDIG)CR-04INVALIDTHE 
    NPA/ABC CODE TO BE ENTERED IS NOT
    SYNTAXSTRICTLY NUMERIC AND CONVERSION FROM THE
    RECORD TO A VALUE HAD FAILED.
    (TABGEN/GENDIG)
    CR-05LASTA DASH (SIGNIFYING A SEQUENCE) IS FOLLOWED
    OPERATORONLY BY BLANKS.
    INVALIDCHECK FIRST TO VERIFY THAT A SEQUENCE WAS
    MEANT INSTEAD OF A SINGLE ENTRY AND, IF IT WAS,
    PROVIDE THE TERMINAL NUMBER OF THE SEQUENCE
    ON THE SAME RECORD.
    (TABGEN/GENDIG)
    CR-06INVALIDA CHARACTER OTHER THAN COMMA, DASH, OR
    OPERATORBLANK HAD BEEN USED IN AN OPERATOR’S POSITION
    IN THE DESIGNATED COLUMN.
    (TABGEN/GENDIG)
    CR-07MISPLACED
    BLANKA BLANK HAD BEEN USED IN AN OPERATOR’S
    LOCATION.
    A COMMA WAS ASSUMED.
    (TABGENIGENDIG)
    CT-01VALUES TO BEHEXADECIMAL EQUIVALENT BYTES
    FILLED LEFT TOHEXADECIMAL EQUIVALENT BYTES MUST BE FILLED
    RIGHT
    IN FROM LEFT TO RIGHT,
    WITH DASHED BYTES IN THE RIGHTMOST BYTES OF
    THE HEXADECIMAL BYTE FIELDS.
    CT-02INVALIDHEXADECIMAL EQUIVALENT BYTES
    CHARACTERIF ONE DIGIT OF A HEXADECIMAL EQUIVALENT BYTE
    PATTERN INIS DASHED,
    2ND FIELDTHE THE OTHER DIGIT OF THE BYTE MUST BE
    DASHED.
    SVR 52108187D-447 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)
    CPG ERROR
    MESSAGESTITLEDESCRIPTION OF MESSAGES
    CT-03
    . . .CT-04 
    -FOR FUNCTIONFUNCTION CODE 
    - HEXADECIMAL EQUIVALENT
    CODE, TNAM,
    BYTES
    BYTES l-8IF THE FUNCTION CODE IS ‘TNAM’,
    MAY NOT BETHEN THE HEXADECIMAL EQUIVALENT BYTES MAY
    SPECIFIEDNOT BE SPECIFIED.
    ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATItjNCT-04ELEMENTSFUNCTION CODE 
    - HEXADECIMAL EQUIVALENT
    HAVEBYTES
    INCOMPATIBLEIF THE FUNCTION CODE IS ‘TNAM’,
    VALUESTHEN THE CUSTOMER DEFINED TERMINAL NAME
    MUST BE SPECIFIED.
    IF THE FUNCTION CODE IS NOT ‘TNAM’, THEN THE
    CUSTOMER DEFINED TERMINAL NAME MUST BE
    DASHED.
    CT-50DUPLICATE TTYTERMINAL TYPE NUMBER 
    - FUNCTION CODE
    NO. AND
    THE TERMINAL TYPE NUMBER AND FUNCTION CODE
    FUNCTIONCOMBINATION CANNOT BE DUPLICATED.
    CODE NOT
    ALLOWED
    CT-51
    DA-01FCN CODES OFFUNCTION CODE
    CLSC , ABCC,THE FOLLOWING FUNCTION CODES ARE REQUIRED
    EEOL, AND
    FOR COMPLETENESS OF A CUSTOMER-DEFINED
    EEOPTERMINAL: ‘CLSC’, ‘ABCC’, ‘EEOL’, AND
    REQUIRED
    ‘EEOP’.(ENDCHK)INVALID
    FIRST DIGIT ACTIONS 
    - SECOND PLUS DIGITS
    CHARACTER
    THERE MUST BE AT LEAST ONE ‘C’ ACROSS BOTH OF
    PATTERN INTHESE FIELDS.
    2ND FIELD
    DA-02INVALID
    CHARACTER
    PATTERN IN
    2ND FIELDFIRST DIGIT ACTIONS 
    - SECOND PLUS DIGITS
    IF THERE IS AN ‘A’ ANYWHERE IN THE FIRST DIGIT
    ACTIONS,
    THERE MUST BE AT LEAST ONE ‘C’ IN THE SECOND
    PLUS DIGITS.
    DA-03INVALID
    FIRST DIGIT ACTIONS CANNOT BE ALL ‘R’.
    CHARACTER
    PATTERN IN
    2ND FIELD
    D-4488187SVR 5210 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    DA-51TRUNK GROUPTHE TRUNK GROUP SPECIFIED MUST HAVE A
    NOT FOUND
    CORRESPONDING 
    Tl RECORD.
    DA-52 
    ‘;IDUPLICATETHIS NUMBER MUST BE UNIQUE ACROSS ALL DA. .TRUNK GROUP RECORDS.
    NUMBER
    y-51DUPLICATEDISPLAYABLE CLASS OF SERVICE NUMBER MUST BE
    DISPMYABLEUNIQUE ACROSS THE DC RECORDS.
    CLASS OF
    SERVICE DATA
    DC-53TRUNKGROUP ATRUNKGROUPREFERENCEDONADCRECORD
    NOT FOUNDWAS NEVER INPUT ON A 
    Tl RECORD.
    (ENDCHK)
    DD-02
    DD-51CLASS OFSWITCHED DIRECT LINE - CO LINE CONFLICT
    SERVICEIF CO LINE INDICATED (‘CL’),
    FEATURESTHEN SWITCHED DIRECT LINE (‘SL’) SHOULD ALSO BE
    CONFLICTINDICATED.
    DUPLICATEDISPLAYABLE CLASS OF SERVICE NUMBER MUST BE
    DISP. CLASS OFUNIQUE ACROSS THE DD RECORDS.
    SERVICE DATA (ENDCHK)
    DD-52CONFERENCEMEET ME CONFERENCE OR PROGRESSIVE
    ClRCUlTS NOTCONFERENCE,
    DEFINEDIF INDICATED, NEEDS ONE OF THE CONFERENCE
    CIRCUITS ON THE FR RECORD SPECIFIED.
    SVR 5210
    8187D-449 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR
    MESSAGES
    CDD-53
    DD-54
    DK-53I
    DT-01
    DT-01TITLE
    TOLL ACCESS
    -TRUNK
    GROUP ACCESS
    CONFLICT
    CLASS OF
    SERVICE NOT
    DEFINED _
    DUPLICATE
    AGENT GROUP/
    REPERTORY
    DIAL KEY
    NUMBER
    VALUE OF
    SECOND
    ELEMENT TOO
    SMALL
    VALUE OF
    SECOND
    ELEMENT TOO
    LARGEDESCRIPTION OF MESSAGES
    IF TOLL ACCESS IS INDICATED (‘TA’) THEN AT LEAST
    ONE TRUNK GROUP IN THE TRUNK GROUP ACCESS
    FIELD ON RECORD DC SHOULD BE 
    ‘Y’.A DISPLAYABLE CLASS OF SERVICE REFERENCED ON
    THE DD RECORD MUST BE DEFINED ON A DC
    RECORD.
    EACH COMBINATION OF AGENT GROUP AND
    REPERTORY DIAL KEY NUMBER MUST BE UNIQUE.
    DTMF RECEIVER NUMBER 
    - PEC REQUIREMENTS
    VALUE OFVALUE OF
    DTMF RECEIVERPEC
    o-7
    8 -15
    16-23
    24-31
    32-39
    40-47
    48-55
    56-6301
    2
    3
    4(SVR8.2.X.X.ONLY)
    5(SVR8.2.X.X.ONLY)
    6(SVR8.2.X.X.ONLY)
    7(SVR8.2.X.X.ONLY)
    RECEIVER NUMBER 
    - PEC
    REQUIREMENTS
    D-4508187SVR 5210 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)
    ZPG ERROR
    MESSAGESTITLEDESCRIPTION OF MESSAGES
    DT-51CARD TYPE
    DEFINED ON FR
    INCOMPATIBLE
    Y-WITH FCN OF
    INCOMING
    CARD
    DT-51CARD TYPE
    DEFINED ON FR
    INCOMPATIBLE
    WITH INCOMING
    CARD TYPE
    DT-51FUNCTION OFPHYSICAL LOCATION
    CARD NOTTHE PEC, GROUP, SLOT AND CIRCUIT FUNCTION
    ALLOWED FORSPECIFIED IS INVALID FOR THE CARD TYPE DEFINED
    CARD TYPEON FR (FOR THIS PEC TYPE).
    DEFINED ONA DTMF RECEIVER CIRCUIT MUST APPEAR ON A
    FORM FRDTMF CARD.
    THE PEC, GROUP, SLOT AND CIRCUIT SPECIFIED IS
    NOT VALID FOR THIS PEC TYPE. (PHYLOC)
    IF THE CARD TYPE IN THE MESSAGE IS “OVER”, THAT
    INDICATES THAT A CARD IN THE PREVIOUS LOCATION
    IS A WIDE CARD AND IT OVERHANGS INTO THIS
    PYHSICAL LOCATION ON FR.
    DT-51PHYSICALPHYSICAL LOCATION
    LOCATION NOTTHE PEC, GROUP AND SLOT SPECIFIED WAS NOT
    DEFINED ONDEFINED ON FR.
    RECORD CODE (PHYLOC)
    FR
    DT-51
    DT-51PHYSICAL
    LOCATION
    PREVIOUSLY
    FILLED
    CARD
    OVERHANGS
    INTO A
    PREVIOUSLY
    FILLED SLOTPHYSICAL LOCATION
    THE PEC, GROUP, SLOT AND CIRCUIT SPECIFIED FOR
    THE DTMF RECEIVER CIRCUIT MUST BE UNIQUE.
    (PHYLOC)
    THIS CARD IS AN OVERSIZED CARD AND IS TRYING
    TO FILL TWO SLOTS. OF THE TWO SLOTS IT FILLS,
    THE RIGHT HAND ONE HAS ALREADY BEEN FILLED.
    DT-51DUPLICATE
    DTMF
    RECEIVER
    NUMBERTHE DTMF RECEIVER NUMBER MUST BE UNIQUE
    ACROSS ALL DT RECORDS.
    SVR 5210
    8187D-451 
    						
    							 rTL-130400-1001ZPG ERROR
    MESSAGES
    Table 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    DT-57DUPLICATE
    DTMF
    RECEIVER
    NUMBERTHE DTMF RECEIVER NUMBER MUST BE UNIQUE
    ACROSS ALL DT RECORDS.
    DT-58PEC NUMBER
    THE PEC NUMBER SPECIFIED MUST BE MARKED
    NOT EQUIPPEDEQUIPPED ON THE OE RECORD.
    EC-01SECOND 
    ‘-NPA CODES MUST BE UNIQUE ON A PER TABLE
    ELEMENT(ONE EC RECORD) BASIS
    EQUALS FIRST
    ELEMENT
    (NPA CODES)
    EC-03ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    EC-03ELEMENT 2 IS
    MEANINGLESS
    SPECIFICATION
    EC-032ND FEATURE
    1 + RESTRICTION TABLE 
    - RESTRICTION CODE TABLE
    REQUIRED IFONLY ONE OR THE OTHER OF THESE MAY BE
    FIRSTSPECIFIED FOR EACH NPA CODE ENTERED.
    SPECIFIEDBOTH CANNOT BE SPECIFIED.
    HOWEVER, BOTH MAY BE DASHED IF DESIRED
    EC-51DUPLICATE
    THE TABLE NUMBER MUST BE UNIQUE ACROSS THE
    CODE CHECK
    EC RECORDS.
    TABLE NUMBE
    EC-53CODE
    THESE TABLE NUMBERS MUST BE DEFINED ON A CR
    RESTRICTIONRECORD.
    TABLE NOT
    FOUND
    ED-01VALUES TO BEPICKUP GROUP NUMBERS SHOULD BE FILLED IN
    FILLED LEFT TOFROM LEFT TO RIGHT.
    RIGHT
    ED-51DUPLICATE
    THIS NUMBER MUST BE UNIQUE ACROSS THE ED
    EXTENDED DIAL RECORDS.
    CALL PICKUP
    TABLE
    D-4528187SVR 5210 
    						
    							TL-130400-1001
    CPG ERROR
    MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    ED-52EXTENDEDEXTENDED DIAL CALL PICKUP TABLE
    PICKUP GROUPEACH TABLE NUMBER SHOULD APPEAR ON AN LD
    NOTRECORD IN THE EXTENDED DIAL CALL PICKUP TABLE
    s-REFERENCEDFIELD.
    -..ON LD FORM
    (ENDCHK)
    -FA-50DUPLICATE
    FRL AUTHORIZATION CODE DUPLICATE
    AUTHORIZATIO
    FRL AUTHORIZATION CODES ARE NOT ALLOWED.
    N CODE
    NUMBER
    FA-51FRLFRL AUTHORIZATION CODE
    AUTHORIZATIOTHE NUMBER OF FRL AUTHORIZATION CODE DIGITS
    N CODE OUT OFON FA RECORD MUST BE THE SAME,
    RANGEAS THE NUMBER OF FRL AUTHORIZATION CODE
    DIGITS SPECIFIED ON OF RECORD (FOUR TO SEVEN
    DIGITS).
    FA-51THREE HASH
    FRL AUTHORIZATION CODE
    BUCKETTHE ALGORITHM USED TO GENERATE THE FRL
    ENTRIES FILLED AUTHORIZATION CODE TABLE ENTRIES HAS
    DETECTED THE OCCURRENCE OF A FOURTH (OR
    FIFTH, SIXTH, SEVENTH, EIGHTH) CODE WITH THE
    SAME HASH VALUE.
    FOR INITIAL ENGINEERING THIS IS IN VIOLATION OF
    ADVERTISED FRL AUTHORIZATION CODE
    GENERATION REQUIREMENTS.
    FOR RE-ENGINEERING, THIS IS A POSSIBLE
    CONDITION.
    THE OCCURRENCE OF A FIFTH CODE WITH THE SAVE
    HASH VALUE WILL CAUSE AN ADDITION DISK ACCESS
    BY CALL PROCESSING.
    (FRLGEN)
    FA-51REACHEDFRL AUTHORIZATION CODE
    MAXIMUMTHE ALGORITHM USED TO GENERATE THE FRL
    BUCKET ENTRY, AUTHORIZATION CODE TABLE ENTRIES HAS
    RECORDDETECTED THE OCCURRENCE OF A NINTH (OR
    REJECTEDMORE) CODE WITH THE SAME HASH VALUE. (FRLGEN)
    FA-52INVALIDFA RECORDS WERE CODED FOR A SITE WITHOUT
    RECORD CODETHE TRAVELING CLASS MARK (TCM) FEATURE,
    I.E. THE TRAVELING CLASS MARK FIELD ON THE OF
    RECORD WAS DASHED OUT.
    FR-01ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    SVR 5210
    8187D-453 
    						
    							TL-130400-1001ZPG ERROR
    MESSAGES
    Table 21.1CPG Error Messages (Continued)TITLE
    DESCRIPTION OF MESSAGES
    FR-01
    . .
    FR-OiVALUE OF
    SECOND
    ELEMENT TOO
    LARGE
    VALUE OF
    CARD TYPE - PRIMARY, SECONDARY, TERTIARY
    SECONDIDENTIFIERS CONSULT THE CARD TYPES VS.
    ELEMENT TOOIDENTIFIERS,
    SMALL
    AND STATUS CHART TO DETERMINE APPROPRIATE
    VALUES TO SPECIFY FOR EACH PARTICULAR CARD
    TYPE.
    FR-02ELEMENTS
    CARD TYPE - PHYSICAL LOCATION
    HAVEIF THE CARD TYPE IS DTRK, THEN THE GROUP FIELD
    INCOMPATIBLEMUST BE ‘C’, SINCE 
    Tl SPANS CAN ONLY BE
    VALUES
    INSTALLED IN THAT GROUP.
    SPECIFIC CARD PLACEMENT RESTRICTIONS ARE IN
    EFFECT FOR THE CARD TYPES OF BT, DCPB, PBE, PR
    AND RPTR.
    THESE CARDS MAY ONLY BE PLACED IN THE
    FOLLOWING GROUP/SLOTS:
    AOO, A02, AlO, BOO, B02, B09,
    C06, Cl 0, CO9, DOO, DO1 , Dl 0.
    FR-03VALUE dFSECOND
    ELEMENT TOO
    LARGE
    FR-03VALUE OFCARD TYPE-PEC
    SECONDTHE FOLLOWING CARD TYPE CAN APPEAR ONLY IN
    ELEMENT TOOPECS O-3: AGNT, AIOD, ART, ATTN, CONF, ERLT,
    SMALLKEDU, AND RLT.
    THE FOLLOWING CARD TYPE SPECIFIES THE VALID
    RANGE OF THE THREE IDENTIFIERS AND STATUS
    GIVEN A PARTICULAR CARD.
    CARD TYPES VS. IDENTIFIERS AND STATUS CHART
    VALUE ALLOWED ALLOWED ALLOWED STATUS
    OFCARD PRIMARY SECONDARY 
    TERITIARY FIELD
    TYPEID RANGE ID RANGEID RANGE
    ADMP 0000-00010000-0001 ---- --
    AGNT ----
    ----------
    D-4548187SVR 5210 
    						
    All GTE manuals Comments (0)