    							TL-130200-1001
    FAULT CODE 19(FAULTCODE1S)REMOVE FUSE
    FROM BATTERY
    PACK
    &POWER DOWN
    . .SYSTEM
    1
    R&R Ml MB IN 
    Y/O1
    FB-17314
    (Check Strapping)
    POWER UPAND RELOAD
    MONITOR
    PSUPY FOR“ASW” TO LIGHT
    IYES
    INO
    T*POWER DOWN &
    REINSTALL ORIGINAL
    Ml MB CARD
    LR&R MPG16 IN 
    Y/O2
    FB-1721’3
    (Check Strapping)
    POWER UPAND RELOAD
    &MONITOR
    PSUPY FOR“ASW” TO LIGHT
    REPLACE FUSEIN BATTERY
    PACK5210
    a/a7M-135 
    						
    							TL-130200-1001
    Fault Code 22Description:MDR SDC FaultAn ambiguous MDR port assignment exists.
    M-l 36
    Register Data as System Prints:CECO CECO Fault 22 B C D E H L
    FF 00 00
    PEC
    Number
    (Always 0)
    05= Improper SDC port
    assignment
    LFault Resolution Steps:
    1.Reload system - depress reset on PSUPY card.
    2.If terminal records output on port 0, mark MDR port 0 in
    service in Table T4551; port 1 must be marked out of
    service; back up the data base.
    3.If terminal records output on port 1, mark MDR port 1 in
    service in Table T4551; port 0 must be marked out of
    service; back up the data base.
    4.Connect the output device to the MDR SDC output port (the
    port which is not marked as maintenance).
    5.Warm start the system - cycle main circuit breaker at rear
    of 
    OMNI SI cabinet.
    6.Place a trunk call which should be recorded by MDR.
    7.If no MDR output, ask for assistance.
    NOTE: MDR SDC port transmission data is derived from Table
    T6051.
    81875210 
    						
    							TL-130200-1001
    FAULT CODE - 22
    FAULT CODE 22
    fREGISTER C = 05
    RELOAD SYSTEM 
    - DEPRESS
    “RESET” ON PSUPY IN 
    P/O1
    1MARK MDR PORT 0 IN SERVICE IN
    PORT
    YESMARK MDR PORT 1 IN SERVICE IN
    NO
    ICONNECT THE OUTPUT DEVICEI
    LTO THE MDR SCD OUTPUT PORT+(THE PORT WHICH IS NOT
    MARKED AS MAINTENANCE)
    WARM START THE SYSTEM 
    -CYCLE MAIN CIRCUIT BREAKER
    AT REAR OF 
    St CABINET
    IF NO MDR OUTPUT, ASK FOR
    ASSISTANCE. NOTE: MDR SDC
    PORT TRANSMISSION DATA IS
    DERIVED FROM TABLE T6051.
    52108187M-137 
    						
    							TL-130200-1001Fault Code 25Description:
    Real-Time Clock FailureThis fault indicates a problem with the Real-Time Clock which is
    part of the CPU85 card..
    Register Data as System Prints:CECO CECO Fault 25 B C D E H L
    \xx/ 00 00 00 00 00
    I
    00= Clock is out of range
    Fl= Read-after-write error
    F2= Real time clock problem
    Fault Resolution Steps:
    1.Power down - turn off main circuit breaker at rear of OMNI
    SI cabinet.
    2.Remove and replace CPU85E, FB-17288-A‘ in Y/O4
    (check strapping).
    3.Power up system.
    4.Monitor PSUPY card in P/O1 for ASW LED to light -
    approximately 15 seconds to warm start.
    81875210 
    						
    							TL-130200-1001. ..--.-v-w --FAULT CODE 25
    +POWER DOWN 
    SYSTEM.
    R&R 
    CPU85E
    FB-I 7288 IN Y/04
    (Check Strapping)POWER UP AND RELOAD
    MONITOR PSUPY FOR
    “ASW” TO LIGHT
    5210
    a/a7M-139 
    						
    							TL-130200-1001Fault Code 27Description:
    Disk Backup FailureWhen a power failure occurs, dynamic memory (containing
    wake-up, message, etc.) is automatically written to disk topreserve data. This fault indicates that the Hotel/Health Care
    dynamic data was not backed up onto the disk.
    M-l 40
    Register Data as System Prints:CECO CECO Fault 27 B C D E H L
    \xx/ xx 00 00 00 00
    Y
    01= Disk operation failed
    02= Disk request failed
    00= Disk backup successful
    1A= File read failed
    1B= File write failed
    Fault Resolution Steps:
    1.Inform customer that the data has been lost and must be
    reentered.
    2.If the problem is hardware related, perform the following
    procedures:
    - Power down system - turn off main circuit breaker at rear
    of 
    OMNI SI cabinet.
    - Remove and replace FMSD in Y/07, FB-17220-BOA,
    (check strapping).
    - Monitor PSUPY for ASW LED to light.
    ala75210 
    						
    							TL-130200-1001
    FAULT CODE - 27
    IPOWER DOWN SYSTEMI“ASW” TO LIGHT
    5210a/a7M-141 
    						
    							TL-130200-1001 TL-130200-1001Fault Code 30Fault Code 30Description: Description:
    Attendant Console Attendant ConsoleCommon transmission to an Attendant Console has failed. Common transmission to an Attendant Console has failed.
    Recovery Recovery
    Data Check Error Data Check Error
    _.Register Data as System Prints:CECO CECO Fault 30 B C D E H L
    ‘X7’ \x7(/ 00 Yxxy 00 00
    Console
    0 or 108= Check sum
    09= Data linkOA = Timeout occurred
    M-142 M-142
    81875210 
    						
    							TL-130200-1001
    FAULT CODE - 30
    IFAULT CODE 30I
    INOTE CONSOLE NUMBER1
    REGISTER E = ?
    1A, 9, OR 8
    ANGLE FAULT h
    A”‘- NO ACTION, IGNORE _
    1NOATTENDANT
    NO ,]I
    labREPLACE ATTENDANT CONSOLE
    1
    YESFORCE ATTENDANT CONSOLE OS
    AND REMOVE AND REPLACE THE
    ATT12 CARD. FORCE CONSOLE
    IN SERVICE.5210
    8187M-143 
    						
    							TL-130200-1001Fault Code 32Description:
    CIPNCIPIDVCIP CardThis fault indicates a failure in the CIPNCIPIDVCIP or VP20 card.
    FailureM-l 44
    Register Data as System Prints:CECO CECO Fault 32 
    B C D E H L
    y 9 lxp xx xx xxPECCard
    NumberNumber
    (Always 0) (O-15)
    00= Card Test Failure
    01= Card XMIT Error
    02= Card Watch Dog Timer Error
    03= Card Hardware Error
    04= Card Initialization Error
    Fault Resolution Steps:
    1.Identify CIP/VCIP/DVCIP or VP20 relative card number
    location by performing a general read of 
    T7053-0, address
    OB2F thru OB3E (GR D2 OB2F OB3E).
    OB2F =Relative Cl Card No. 0
    OB30 = Relative Cl Card No. 1
    OB31 = Relative Cl Card No. 2
    0832 = Relative Cl Card No. 3
    0833 =Relative Cl Card No. 4
    OB34 =Relative Cl Card No. 5
    0835 =Relative Cl Card No. 6
    0836 =Relative Cl Card No. 7
    0837 =Relative Cl Card No. 8
    0838 = Relative Cl Card No. 9
    OB39 = Relative Cl Card No. 10
    OB3A =Relative Cl Card No. 11
    OB3B =
    Relative Cl Card No. 12
    OB3C =Relative Cl Card No. 13
    OB3D =Relative Cl Card No. 14
    OB3E =Relative Cl Card No. 15
    2. Interpret contents to indicate physical location of card.
    81875210 
    						