    CPG ERROR
    MESSAGES21.0 Table 21 .l describes the error messages that are
    detected by the CPG program. These massages are used to
    correct the errors that are generated in a CPG run.
    .  
    .
    8187D-415 
    						
    							Table 21.1CPG Error Messages TL-130400-1001DESCRlPTlON OF MESSAGES
    AS SHOWNINTHE CODE SYMBOL MODULE
    VALUE OF 
    ‘-ELEMENT TOO
    PRIATEFOR THE CODE TYPE.
    INVALID VALUE
    L MODULE FOR VALID VALUES
    DIGIT COMBINATIONS.
    D-41 6SVR 5210 
    						
    							CPG ERROR
    MESSAGES
    AC-52. . . .AC-52
    AC-52
    AC-52
    AC-52
    AC-52TITLE
    FEATURE NOT
    USABLE
    WITHOUT
    INDICATED
    . .RECORDCODE
    .  
    .AGENT GROUP
    NUMBER NOT
    FOUND
    ATTENDANT
    NOT FOUND
    CLASS OF
    SERVICE
    REQUIRED
    FEATURE NOT
    USABLE’
    WITHOUT
    CLASS OF
    SERVICE MARK
    SODE TYPE
    IDENTIFIER 
    -
    DN-NET CODE
    3N TR
    Table 21.1CPG Error MessagesDESCRIPTION OF MESSAGES
    THE LISTED RECORD CODE IS REQUIRED FOR THE
    CODE TYPE SPECIFIED.
    RECORD CODESCODE TYPES
    AD
    113AT
    5-18, 45-46, 89-90,
    102, 106-l 07
    CL
    76
    :“s
    22512,119
    MK
    70
    PN30
    RC53, 55-56
    WT
    98-l 00, 
    115THE AGENT GROUP NUMBER SPECIFIED IN THE CODE
    TYPE IDENTIFIER FIELD FOR CODE TYPE 112 MUST
    BE DEFINED ON AN AG RECORD.
    THE ATTENDANT NUMBER/S SPECIFIED IN THE CODE
    TYPE IDENTIFIER FIELD FOR CODE TYPE 9 MUST BE
    DEFINED ON AN AT RECORD.
    THE LISTED CLASS OF SERVICE MARK ON RECORDS
    DC, DD OR NC IS REQUIRED FOR THE SPECIFIED
    CODE TYPES TO WORK.
    CLASS OF SERVICE MARK
    CODE TYPE
    CC (RECODE CODE DC, DD)
    22,23CF (RECODE CODE NC)
    20CV RECODE CODE NC)
    21CO (RECODE CODE NC)
    28,29EX (RECODE CODE NC)
    19HD (RECODE CODE NC)
    40,44MC (RECODE CODE NC)
    32,33PA (RECODE CODE DC, DD)
    34,35PC (RECODE CODE DC, DD)
    33,32PK (RECODE CODE NC)
    39,43RL (RECODE CODE DC, DD)
    53SA (RECODE CODE NC)
    120UN (RECODE CODE NC)
    31(ENDCHK)
    THE ON-NET CODE SPECIFIED IN THE CODE TYPE
    IDENTIFIER FIELD FOR CODE TYPE 105 MUST BE
    DEFINED ON A TR RECORD.
    SVR 5210TL-130400-1001
    8187D-41 7 
    						
    							TL-130400-1001
    Table 21.1CPG Error Messages
    DESCRIPTION OF MESSAGES’WITH TRUNKMUST BE DEFINED WITH A COMPATIBLE
    APPLICATION ON A 
    Tl RECORD.
    ECIFIED ON AN SA REC
    RECORD WITH A CODE
    THEPILOT NUMBER SPECIFIEDIN THE CODE TYPE
    IDENTIFIER FIELD FOR CODE TYPES 37, 38, 41, 42, 61,
    62 ,138, OR 139 MUST BE DEFINED AS THE PILOT
    NUMBER OF THE CORRESPONDING HUNT GROUP ON
    Tl AND TC RECORDS AS A RECORDER ANNOUNCER.
    D-41 88187SVR 5210 
    						
    							Table 21.1
    CPG Error Messages (Continued)TL-130400-1001
    CPG ERROR
    MESSAGESTITLEDESCRIPTION OF MESSAGES
    AC-53CLASS OF
    A FEATURE WAS SPECIFIED IN THE CLASS OF
    SERVICE/SERVICE RECORD CODES (DC, DD, NC),
    ACCESS CODEBUT AN ACCESS CODE FOR THE FEATURE WAS NOT
    .i_ERRORDEFINED.
    DISPLAYABLE ACCESS CODE
    CLASS OF SERVICE TYPE
    cc
    22,23
    DA36MC
    32,33ME
    48
    PA
    34,35
    PC
    32,33
    RL
    53,55,56N-DISPLAYABLEACCESS CODE
    CLASS OF SERVICE TYPE
    EL
    20
    28,29cv
    21
    DC24
    DD
    71,72EX
    19HD
    40,44MA
    83oc
    13,14
    ri:
    39,43
    120
    SC119UN
    31wu
    81,82(ENDCHK)
    AC-54NO ACCESSACCESS CODES SHOULD BE DEFINED FOR ALL
    CODE FOUNDTRUNK GROUPS HAVING A DIRECTION OF OUTGOING
    FOR TRUNKOR TWO-WAY ON A 
    Tl RECORD.
    GROUP. NOIF A TRUNK GROUP DOES NOT HAVE AN ACCESS
    ACCESS FOUNDCODE, ACCESS TO IT MUST BE PROVIDED ON
    FOR TRUNKANOTHER RECORD CODE SUCH AS NT, TD, LS, OR
    GROUP
    SVR 5210
    Em7D-419 
    						
    							Table 21.1CPG Error Messages (Continued)TL-130400-1001
    DESCRIPTION OF MESSAGES
    DEFINED ON AN AC RECORD.
    ACCESS CODE
    CODETYPEIDENTIFIER
    FIRST DIGIT OF
    A TWO DIGIT
    ACCESS CODE
    TWO DIGIT
    ACCESS CODE
    FIRST DIGIT OF
    A THREE DIGIT
    ACCESS CODE
    REQUIRED, AND IF TIME PERIOD CONTROL WAS
    SPECIFIED ON AN AT 
    RECORD,THEN CODE TYPE 100
    IS REQUIRED.
    NEVER THERE-ARE RN RECORDS WITH
    OF 3DG OR 4DG.
    FOR SILENT MONITOR ACCESS CODE 
    (64),FR RECORD.
    EQUIPPED ON
    SVR 5210 
    						
    							Table 21.1CPG Error Messages (Continued)TL-130400-1001
    DESCRIPTION OF MESSAGES
    PREVIOUSLY
    THE MERS ON-NET NPA MUST HAVE BEEN DEFINED
    ON A TR RECORD.
    MERS ON-NET NPA MUST HAVE BEEN DEFINED
    MR FORM 
    .vAN ACCESS CODE MUST BE PROVIDED WITH ONE OF
    THEFOLLOWING CODE TYPES: 94, 96,
    105,126,ORFIELD VALUEIF THE OPI CARD IS EQUIPPED ON FR,
    ODE TYPE IDENTIFIER MUST BE IN THE RANGE
    SUPERVISORAGENTLINE’2FOR OTHER AGENTS IS ASSIGNED ON
    AN LD RECORD.
    CHARACTERIF THE SUPERVISOR FIELD IS SPECIFIED.
    SVR 5210
    8187D-421 
    						
    							TL-130400-1001Table 21.1CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
    INCOMPATIBLE
    DATA LINK PHYSICAL LOCATION
    THE PEC, GROUP, SLOT, AND CIRCUIT FUNCTION
    ALLOWED FOR
    SPECIFIED IS INVALID FOR THE CARD TYPE DEFINED
    ON FR(FOR THIS PEC TYPE).
    DEFINED ON
    IF THE CARD TYPE IN THE MESSAGE IS “OVER”,
    THAT INDICATES THAT A CARD IN THE PREVIOUS
    TIONIS A WIDE CARD AND
    ERHANGS INTO THIS 
    PYHSICAL LOCATION ON
    NONEXISTENT
    IRCUIT SPECIFIED IS
    DEFINED ON
    RECORD CODE
    AD-56
    PHYSICAL
    LOCATION
    PREVIOUSLY
    FILLEDDATA LINK PHYSICAL LOCATION
    THE PEC, GROUP, SLOT, AND CIRCUIT SPECIFIED FOR
    THE AGENT DATA LINK MUST BE UNIQUE.
    AD-58REQUIREDTHE LINE NUMBER OF SUPERVISOR LINE 2 MUST BE
    VALUE NOTA VALID ENTRY ON AN LD RECORD.
    FOUND ON
    LISTED FORM
    AD-59
    FUNCTION OFSELF 
    - EXPLANATORY
    AGENT GROUP
    MUST BE ACD IF
    DATA LINK
    EQUIP IS 
    -SVR 5210 
    						
    							TL-130400-1001
    Table 21.1CPG Error Messages (Continued)
    DESCRIPTION OF MESSAGES
    THEN ANOTHER AGENT SUPERVISOR CANNOT
    THE ALREADY DEFINED SUPERVISOR NUMBER.-..ON LINE 1 HAS
    FEATUREi OC, CO, DC, CV, CF,TC, TD, UN, TM, PD,
    HD, PK, CN, 
    DD,WU, MA AND SD ARE NOT ALLOWED
    WHEN THE FIELD ALLOW AGENT CALL ORIGINATION
    ONLINE 
    1HAS THE VALUE ‘A’.
    IT IS SPECIFIED
    PROVIDED ON FR RECORD.
    EQUIPPED ON
    CONSISTENTLY
    SVR 5210
    8187D-423 
    						
    							 rTL-130400-1001
    CPG ERROR
    MESSAGES
    AF-02AF-51
    AF-51
    AF-51
    AF-51
    D-424AF-52
    AF-53
    AG-01
    Table 21.1TITLE
    DASHES MUST
    BE USED
    CONSISTENTLY
    IN FIELD
    ELEMENTS
    HAVE
    INCOMPATIBLE
    VALUES
    PHYSICAL
    LOCATION
    PREVIOUSLY
    FILLED
    NONEXISTENT
    PHYSICAL
    LOCATION
    CARD OVER-
    HANGS INTO A
    PREVIOUSLY
    FILLED SLOT
    PREVIOUS
    CARD
    OVERHANGS
    INTO 
    TH,lS SLOT
    INVALID PILOT
    NUMBER
    SPECIFICATION
    PEC NUMBER IS
    NOT EQUIPPED
    NIGHT DAY
    MODE 
    - NIGHT
    DIVERT
    DESTINATION
    CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
    THE 
    9TH ART CARD MUST USE DASHES
    CONSISTENTLY.
    CHECK ON EQUIPPED STATUS
    IF PEC, GROUP, AND CARD SLOT FIELDS ARE
    DASHES, THEN THE EQUIPPED STATUS MUST BE ‘N’.
    THE 
    9TH ART CARD MUST CONTAIN A UNIQUE
    PHYSICAL LOCATION.
    THE CARD WAS ASSIGNED TO A NONEXISTENT
    PHYSICAL LOCATION.
    THIS CARD IS AN OVERSIZED CARD AND IS TRYING
    TO FILL TWO SLOTS.
    OF THE TWO SLOTS IT FILLS,
    THE RIGHT HAND ONE HAS ALREADY BEEN FILLED.
    THE CARD TO THE LEFT OF THIS SLOT IS AN
    OVERSIZED CARD1
    THE RIGHT HALF 
    6F THAT CARD FILLS THIS SLOT.
    THE PILOT NUMBER SPECIFIED IN THE ACD PILOT
    NUMBERS 1 THRU 4 MUST APPEAR AS A PILOT
    NUMBER ON AN HG RECORD.
    THE PEC NUMBER SPECIFIED MUST BE MARKED
    EQUIPPED ON THE OF RECORD.
    IF NIGHT MODE IS SPECIFIED,
    THEN A NIGHT DIVERT DESTINATION MUST BE
    SPECIFIED.
    8187SVR 5210 
    						