    							TL-130200-1001B
    PREMOVE AND REPLACE
    FB-207181 CARD.
    IIF PROBLEM STILL EXISTS,
    REINSERT THE ORIGINAL CARD
    AND REPLACE MPB85 
    FB-17215-A CARD IN x/4 (NOTE).
    PROBLEM STILL
    YESNOTE: See paragraph 1.4.5.
    Figure 5.10Tl-Type Trunk Loss of Supervision Troubleshooting Flowchart (Sheet 5 of 7)5210
    8l87 
    						
    							TL-130200-1001B
    PREINSTALL ORIGINAL MPB85
    CARD. REMOVE ALL OTHER
    CARDS RESIDING IN FILE WITH
    _.TROUBLED Tl -TYPE TRUNK
    INTERFACE EXCEPT THE CARDS
    REMOVED PREVIOUSLY.
    FB-17192-A 
    TlB2
    FE1 7277-A OR 15277-1SILFB-15278-A FDC
    FB-15280-A LCM
    FB-20718-l 
    TlSUPERVISORY
    FB-17215-A MPB85
    IIS THE PROBLEM
    D
    YESNO
    v
    nH
    Figure 5.10Tl-Type Trunk Loss of Supervision Troubleshooting Flowchart (Sheet 6 of 7)ISOLATE DEFECTIVE CARD BY
    REINSTALLING REMOVED CARDS,
    ONE AT A TIME, UNTIL FAILURE
    OCCURS. REMOVE AND REPLACE
    DEFFECTIVE CARD.
    I
    M-18681875210 
    						
    							TL-130200-1001Figure 6.10Tl-Type Trunk Loss of Supervision Troubleshooting Flowchart (Sheet 7 of 7)AT THIS POINT CHECK FOR THE
    PROBLEM IN THE INTERFACE
    CABLE BETWEEN THE FILES.
    REPLACE CABLE ONE AT A TIME.
    IF THE PROBLEM STILL EXISTS
    AFTER EACH REPLACEMENT,
    REINSTALL THE ORIGINAL CABLE.
    IF THE PROBLEM STILL EXISTS,
    CALL EXPERIENCED
    MAINTENANCE PERSONNEL. THE
    PROBLEM MAY BE DUE TO A
    MULTIPLE CARD FAILURE.
    BACKPLANE WIRE, OR FAR-END
    INTERFACING EQUIPMENT.
    NOTE: See paragraph 
    1.4.5.
    52108187M-187 
    						
    							TL-130200-1001
    STARTciARE ANY FAULT ARE ANY FAULT
    CODES PRINTED ON CODES PRINTED ON
    THE MAINTENANCE THE MAINTENANCE
    YES YES
    1NO
    IS THE SYSTEM
    SYNCHRONIZED?IS PROBLEM
    COMMON TO THE
    aB
    YESNONO
    vvREFER TO SYSTEM FAULT TABLES
    nC
    Figure 5.11Tl-Type Trunk Loss of Transmission Troubleshooting Flowchart
    (Sheet 1 of 6)
    8l875210 
    						
    							TL-130200-1001
    CP
    . .PROBLEM STILL
    l
    YESREMOVE ALL OTHER CARDS
    RESIDING IN FILE WITH TROUBLED
    Tl -TYPE TRUNK INTERFACE
    EXCEPT THE CARDS REMOVED
    PREVIOUSLY.
    FB-17192-A 
    TlB2FB-17277-A OR 15277-1 
    SILFB-15278-A FDC
    FB-15280-A LCM
    FB-20718-I Tl
    SUPERVISORY
    I
    4+Dcl
    PROBLEM STILL
    YES
    1NO
    (END)
    Figure 5.11Tl-Type Trunk Loss of Transmission Troubleshooting Flowchart
    (Sheet 2 of 6)
    5210Em7M-189 
    						
    							TL-130200-1001E
    YREFER TO SYSTEM FAULT CODES
    PROBLEM STILL
    M-190
    Figure 6.11Tl-Type Trunk Loss ot Transmlsslon I rouDlesnoortng rlowcnarr(Sheet 3 of 6)
    81875210 
    						
    							TL-130200-1001D
    7REMOVE ALL OTHER CARDS IN
    FILE EXCEPT FOR THE FIVE
    DIGITAL TRUNK CARDS REMOVED
    PREVIOUSLY AND THE MPB85 
    FB--T-1721 5-A CARD (SEE NOTE).I
    1
    b
    YES
    1NO
    REINSTALL ALL CARDS REMOVED
    FROM THE FILE. REMOVE AND
    REPLACE THE CHM85
    FB-17218-A CARD IN X/l
    (NOTES 1 AND 2).
    IIFISOLATE DEFFECTIVE CARD BY
    INSTALLING THE REMOVED CARDS
    ONE AT A TIME UNTIL FAILURE
    OCCURS. REMOVE AND REPLACE
    THE DEFFECTIVE CARD.
    NOTE: See paragraph 1.4.5.
    Figure 5.11Tl-Type Trunk Loss of Transmission Troubleshooting Flowchart
    (Sheet 4 of 6)5210
    8187M-191 
    						
    							TL-130200-1001PROBLEM STILLPROBLEM STILLbb
    YES YESNO NO
    v
    [ END )REINSTALL ORIGINAL CHM85
    FB-17218-A CARD INTO THE
    FILE. CHECK FOR PROBLEM IN
    THE INTERFACE CABLES BETWEEN
    THE CHM85 CARD AND THE
    EPCMN FB-17217-A CARD.
    REMOVE AND REPLACE ONE TAB
    CABLE AT A TIME. IF THE
    PROBLEM IS NOT SOLVED,
    REINSERT THE ORIGINAL CABLE
    ONE AT A TIME.
    YES ‘=
    Figure 5.11
    Tl-Type Trunk Loss of Transmission Troubleshooting Flowchart
    (Sheet 5 of 6)M-192
    8l675210 
    						
    							TL-130200-1001G
    PIREINSTALL ORIGINAL INCKS.REMOVE AND REPLACE 
    INCKSFB-20992-A OF INC FB-20771 l-1
    (NOTES 1 AND 2)IFB-20992-A CARD. REMOVE
    AND REPLACE EPCMN
    FB-17217-A CARD IN Y/9.
    (NOTES 1 AND 2). .1
    NO
    FAR-END INTERFACE EQUIPMENT.
    ‘I0
    ANOTES:
    1. See paragraph 1.4.5.
    2.Before removing or replacing these cards,disconnect the cables from the front of the card.
    Figure 5.11Tl-Type Trunk Loss of Transmission Troubleshooting Flowchart
    (Sheet 6 of 6)
    5210ala7M-193 
    						
    							START7CODES PRINTED ONREFER TO SYSTEM FAULT
    THE MAINTENANCE
    CODES.TABLES.NO
    IS THE PROBLEM
    COMMON TO THE
    YES
    1NO
    clA
    -.-.- -.-FIgWe 5.12Tl -Type Trunk Loss of Frame Synchronization Troubleshopting Flowchart
    (Sheet 1 of 10)
    %I875210 
    						