    							6/02
    6-17 DC1632/2240General Procedures and Information Prelaunch Training/Review 715-229 Color Balance Default =  K/Low density 4 0~8 Default Color Balance Adjustment Level K Color Low density
    715-230 Color Balance Default =  K/Medium 
    density4 0~8 Default Color Balance Adjustment Level K Color Medium density
    715-231 Color Balance Default =  K/high density 4 0~8 Default Color Balance Adjustment Level K Color High density
    715-232 Photo reproduction level 1 0~2 0 =  Above Text, 1 =  Normal, 2 =  Above Photo
    715-233 Text/Photo separation level  2 0~4 0 =  Above Text, 1 =  Slightly above text, 2 =  Normal, 3 =  Slightly above photo, 4 =  Above Photo
    715-234 FS Magnification Adjustment  50 0~100 Magnification fine adjustment in Fast Scan direction. Specified in units between range of 0~100. The value indi-
    cates the magnification adjustment with 0= -5%, 50= 0% and 100= 5% at ±5% (0.1% unit) (Adjustment at fac-
    tory.)
    715-237 Normal Density Text (BW Copy) 128 0~256 B/W COPY Text Normal Density Adjustment
    715-238 High Density Text (BW Copy) 128 0~256 B/W COPY Text Darker 3 Density Adjustment
    715-239 Normal Density Text (Scan) 128 0~256 Scan Text Normal Density Adjustment
    715-240 High Density Text (Scan)  128 0~256 Scan Text Darker 3 Density Adjustment
    715-241 SS Not Detect Area for Platen model 
    (Real Time AE)38 0~65535 Slow Scan Non-detection area Setup value at Real Time AE for platen model.
    715-242 SS Not Detect Area for DADF model 
    DADF mode (Real Time AE)38 0~65535 Slow Scan Non-detection area Setup value at Real Time AE for DADF model platen job.
    715-243 SS Not Detect Area for DADF model 
    Platen mode (Real Time AE)38 0~65535 Slow Scan Non-detection area Setup value at Real Time AE for DADF model DADF job.
    715-244 B/W-Offset for Text/Image Platen mode 
    (Real Time AE)10 0~255 For AE OFFSET data Platen text/photo in B/W model
    715-245 B/W-Offset for Text Platen mode (Real 
    Time AE)10 0~255 For AE OFFSET data Platen text in B/W model
    715-246 B/W-Offset for Map Platen mode (Real 
    Time AE)10 0~255 For AE OFFSET data Platen map in B/W model
    715-247 B/W-Offset for Text/Image DADF Single 
    Side mode (Real Time AE)13 0~255 For AE OFFSET data DADF Single Side Document text/photo in B/W model
    715-248 B/W-Offset for Text DADF Single Side 
    mode(Real Time AE)15 0~255 For AE OFFSET data DADF Single Side Document text in B/W model
    715-249 B/W-Offset for Map DADF Single Side 
    mode Real Time AE)13 0~255 For AE OFFSET data DADF Single Side Document map in B/W model
    715-250 B/W-Offset for Text/Image DADF 
    Duplex Side mode (Real Time AE)17 0~255 For AE OFFSET data DADF Duplex Side Document text/photo in B/W model
    715-251 B/W-Offset for Text DADF Duplex Side 
    mode (Real Time AE)17 0~255 For AE OFFSET data DADF Duplex Side Document text in B/W model
    715-252 B/W-Offset for Map DADF Duplex Side 
    mode (Real Time AE)17 0~255 For AE OFFSET data DADF Duplex Side Document map in B/W model
    715-253 Color-Offset for Text/Image Platen 
    mode (Real Time AE)15 0~255 For AE OFFSET data Platen text/photo in Color model
    715-254 Color-Offset for Text Platen mode (Real 
    Time AE)15 0~255 For AE OFFSET data Platen text in Color model
    715-255 Color-Offset for Text Platen mode (Real 
    Time AE)15 0~255 For AE OFFSET data Platen map in Color modelTable 3 Chain 715
    Chain-Link Name Default Range Description 
    						
    							6/02
    6-18DC1632/2240 Prelaunch Training/Review General Procedures and Information715-256 Color-Offset for Text/Image DADF Sin-
    gle Side mode (Real Time AE)17 0~255 For AE OFFSET data DADF Single Side Document text/photo in Color model
    715-257 Color-Offset for Text DADF Single Side 
    mode (Real Time AE)18 0~255 For AE OFFSET data DADF Single Side Document text in Color model
    715-258 Color-Offset for Map DADF Single Side 
    mode (Real Time AE)17 0~255 For AE OFFSET data DADF Single Side Document map in Color model
    715-259 Color-Offset for Text/Image DADF 
    Duplex Side mode (Real Time AE)17 0~255 For AE OFFSET data DADF Duplex Side Document text/photo in Color model
    715-260 Color-Offset for Text DADF Duplex Side 
    mode (Real Time AE)18 0~255 For AE OFFSET data DADF Duplex Side Document text in Color model
    715-261 Color-Offset for Map DADF Duplex 
    Side mode (Real Time AE)17 0~255 For AE OFFSET data DADF Duplex Side Document map in Color model
    715-300 IIT Fail Bypass 0 0~1 0 =  Fail Bypass is not available, 1 =  Fail Bypass is available
    715-301 SS Registration Adjustment 100 16~184 Slow Scan Direction Regi Correction Value (0.036mm/step)  Adjustment at factory.
    715-302 SS Magnification Adjustment 50 44~56 Slow Scan direction Magnification Correction Value (0.1%/step)  Adjustment at factory.
    715-400 Platen/ADF 0 0~1 0 =  Platen model  1 =  ADF model  Adjustment at factory.
    715-401 AGOC Timing 15 0~29 Time between Power ON/Energy Saver recovery and AGOC (min.) (0 =  Timer not available)
    715-800 lIISS/ADF Communication Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-801 IISS/ADF Communication Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-802 lIISS RAM CHECK Failure Count Over-
    all Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-803 IISS RAM CHECK Failure Count Since 
    Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-804 EEPROM Failure Count Overall Total 0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-805 EEPROM Failure Count Since Reset 0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-806 Fan Failure Count Overall Total 0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-807 Fan Failure Count Since Reset 0 0~065535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-808 Scan Carriage Position Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-809 Scan Carriage Position Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-810 Scan CRG Init Regi SNR Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-811 Scan CRG Init Regi Sensor Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-812 PreIPS (X) Recognition Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-813 PreIPS (X) Recognition Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-814 Lamp Failure Count Overall Total 0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-815 Lamp Failure Count Since Reset 0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)Table 3 Chain 715
    Chain-Link Name Default Range Description 
    						
    							6/02
    6-19 DC1632/2240General Procedures and Information Prelaunch Training/Review 715-816 CRG Over Run Fail Count Overall Total 
    (Scan End)0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-817 CRG Over Run Fail Count Since Reset 
    (Scan End)0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-818 CRG Over Run Fail Count Overall Total 
    (Home End)0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-819 CRG Over Run Fail Count Since Reset 
    (Home End)0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-820 CRG INIT Motor Driver Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-821 CRG INIT Motor Driver Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-822 Platen AGC Channel 1 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-823 Platen AGC Channel 1 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-824 Platen AGC Channel 2 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-825 Platen AGC Channel 2 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-826 Platen AGC Channel 3 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-827 Platen AGC Channel 3 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-828 Platen AGC Channel 4 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-829 Platen AGC Channel 4 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-830 Platen AGC Channel 5 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-831 Platen AGC Channel 5 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-832 Platen AGC Channel 6 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-833 Platen AGC Channel 6 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-834 Platen AOC Channel 1 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-835 Platen AOC Channel 1 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-836 Platen AOC Channel 2 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-837 Platen AOC Channel 2 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)Table 3 Chain 715
    Chain-Link Name Default Range Description 
    						
    							6/02
    6-20DC1632/2240 Prelaunch Training/Review General Procedures and Information
    719--xxx IIT/DADF Software NVM List715-838 Platen AOC Channel 3 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-839 Platen AOC Channel 3 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-840 Platen AOC Channel 4 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-841 Platen AOC Channel 4 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-842 Platen AOC Channel 5 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-843 Platen AOC Channel 5 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-844 Platen AOC Channel 6 Fail Count 
    Overall Total0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-845 Platen AOC Channel 6 Fail Count 
    Since Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-854 Original Size Sensor Failure Total 
    Count0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-855 Original Size Sensor Failures Since 
    Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-856 IIT Memory Hot Line Failure Total 
    Count0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-857 IIT Memory Hot Line Failures Since 
    Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-858 DADF RAM CHECK Failure Total 
    Count0 0~65535 Cumulative Fail Counter (Write not permitted)
    715-859 DADF RAM CHECK Failures Since 
    Reset0 0~65535 Cumulative Fail Counter at the previous clearing (Write not permitted)
    715-900 Scan Life Count (upper digits) 36 0~65535 Scan Count Replacement Life (Upper Level) (Write not permitted)
    715-901 Scan Life Count (lower digits) 40704 0~65535 Scan Count Replacement Life (Lower Level) (Write not permitted) Table 3 Chain 715
    Chain-Link Name Default Range Description
    Table 4 Chain 719
    Chain-Link Name Default Range Description
    719-001 Version No. (Upper level) 0 0~65535 Indicates the IISS Version No.
    719-002 Market Information 0 0~3 FX=0, AP=1, XC=2, XE=3
    719-003 A4/Letter 1 0~3 Basic unit of document size. For A4 =  bit0=1, letter =  bit=1 *Checking of range is not performed.
    719-004 ADF Version No. 0 0~65535 Indicates the ADF Version No.
    719-005  IISS Major Version 0 0~65535 IISS Major Version No.
    719-006 IISS Minor Version 0 0~65535 IISS Minor Version No.
    719-007 IISS Revision Version 0 0~65535 IISS Revision Version No.
    719-008 IISS Patch Version 0 0~65535 IISS Patch Version No. 
    						
    							6/02
    6-21 DC1632/2240General Procedures and Information Prelaunch Training/Review
    720-xxx ESS Meter/Counter NVM List
    740--xxx IOT Manager NVM List
    719-010 ADF Major Version 0 0~65535 ADF Major Version No.
    719-011 ADF Minor Version 0 0~65535 ADF Minor Version No.
    719-012 ADF Revision Version 0 0~65535 ADF Revision Version No.
    719-013 ADF Patch Version 0 0~65535 ADF Patch Version No.Table 4 Chain 719
    Chain-Link Name Default Range Description
    Table 5 Chain 720
    Chain-Link Name Default Range Description
    720-002 Billing PFV BILL-
    ING TYPE11~6 1 =  Billing1, 2 =  Billing2, 3 =  Billing3, 4 =  Billing4, 5 =  Billing5, 6 =  Billing6
    720-003 Master Print-Full Color - 0~1999999 0~1,999,999
    720-004 Master Print-Color1 - 0~1999999 0~1,999,999
    720-005 Master Print-Color2 - 0~1999999 0~1,999,999
    720-006 Master Print-B&W - 0~1999999 0~1,999,999
    720-012 Backup1 Print-Full Color - 0~1999999 0~1,999,999
    720-013 Backup1 Print-Color1 - 0~1999999 0~1,999,999
    720-014 Backup1 Print-Color2 - 0~1999999 0~1,999,999
    720-015 Backup1 Print-B&W - 0~1999999 0~1,999,999
    720-040 [PSW Display] Group 0 0~999999999
    9990~999999999999 (0 means not set up)
    720-041 TBD 0 0~999999999
    9990~999999999999 (0 means not set up)
    720-042 TBD 0 0~3 0 = FreeAccess, 1 =  Color Only, 2 =  B&W Only, 3 =  Cannot be used
    720-043 TBD 0 0~3 0 = FreeAccess, 1 =  Color Only, 2 =  B&W Only, 3 =  Cannot be used
    720-044 Group C Mode to use 0 0~3 0 = FreeAccess, 1 =  Color Only, 2 =  B&W Only, 3 =  Cannot be usedTable 6 Chain 740
    Chain-Link Name Default Range Description
    740-024 RegiCon Request Flag 0 0~255 0 =  Performed, 1 =  Not performed
    740-025 Edge Check Request Flag 0 0~255 0 =  Performed, 1 =  Not performed
    740-026 ProCon Request Flag 0 0~255 0 =  Performed, 1 =  Not performed 
    						
    							6/02
    6-22DC1632/2240 Prelaunch Training/Review General Procedures and Information
    741--xxx Drive NVM List
    742--xxx Paper Handling NVM List
    Table 7 Chain 741
    Chain-Link Name Default Range Description
    741-054 NVM_PR_MOT_HIGH_PULSE (PR 
    (Drum) Motor Speed Fine Adjustment 
    (Standard)23 0~40 Performs fine adjustment of Drum Speed at Standard Speed. Increases the Drum Speed by +1 (approx. 0.05%) 
    with respect to the initial value. Decreases the Drum Speed by -1 (approx. 0.05%).
    741-055 NVM_PR_MOT_LOW_PULSE (PR 
    (Drum) Motor Speed Fine Adjustment 
    (Heavy Weight /Transparency)23 0~40 Fine adjusts the Drum Speed at half speed. Increases the Drum Speed by +1 (approx. 0.05%) with respect to 
    the initial value. Decreases the Drum Speed by -1 (approx. 0.05%).
    741-056 Belt Home Fail Too Long Counter 0 0~3 It is necessary to reset the No. of Occurrence of Belt Home Fail Too Long to 3.
    741-057 NoPaperRun Mode SW 0 0~2 0 =  Normal NoPaperRun 1 =  MainMotor Stop 2 =  Main/Dev. Motor Stop
    741-068 NVM_PR_MOT_DOUBLE_PULSE (PR 
    (Drum) Motor Speed Fine Adjustment 
    (Double Speed)22 0~40 Fine adjusts the Drum Speed at double speed. Increases the Drum Speed by +1 (approx. 0.05%) with respect 
    to the initial value. Decreases the Drum Speed by -1 (approx. 0.05%).Table 8 Chain 742
    Chain-Link Name Default Range Description
    742-001 Invert Clutch CW Off Timing 82  0~163
    (1bit= 2.4462ms)Paper inversion position adjustment (P Speed) default=2300ms
    742-002 Invert Clutch CW Off Timing (MF-1) 106 0~259 
    (1bit= 1.31136ms)Paper inversion position adjustment (Double Speed)
    742-006 RegiLoopLengthAjust (Tray Standard 
    Paper)41 0~81 
    (1bit= 2.4462ms)Regi Loop Length Adjustment (P Speed) for Standard Paper from Tray. Default=260ms
    742-007 RegiLoopLengthAjust (Tray Standard 
    Paper) (MF)41 0~81 
    (1bit= 1.31136ms)Regi Loop Length Adjustment (Double Speed) for Standard Paper from Tray
    742-009 RegiLoopLengthAjust (Tray 5 Standard 
    Paper)41 0~81 Regi Loop Length Adjustment (P Speed) for Standard Paper from Tray 5 (1bit= 2.4462ms)
    742-011 RegiLoopLengthAjust (Tray 5 Standard 
    Paper) (MF)41 0~81 
    (1bit= 1.322ms)Regi Loop Length Adjustment (Double Speed) for Standard Paper from MSI
    742-013 RegiLoopLengthAjust (Tray 5 Heavy2 
    Paper)41 0~81 
    (1bit= 4.8924ms)Regi Loop Length Adjustment (Half Speed) for Heavy Weight Paper from MSI. Default=221ms
    742-014 RegiLoopLengthAjust (DUP) (2sheets 
    of paper)41 0~81 
    (1bit= 2.4462ms)Regi Loop Length Adjustment (P Speed) from Dup (Feeding length Letter-LEF and Shorter) Default=157ms
    742-015 RegiLoopLengthAjust (DUP) (MF) 76 0~152
    (1bit= 1.31136ms)Regi Loop Length Adjustment (Double Speed) from Dup 
    742-016 T/A Clutch On Timing (From Regi Start) 20  8~32 
    (1bit= 2.4462ms)Synchronize adjustment to be same as Regi Clutch at Regi Start (-30~30ms) Default=0ms
    742-017 Dup  On Timing (From Regi Start) 20  0~40 
    (1bit= 2.4462ms)Synchronize adjustment to be same as Regi Clutch at Regi Start (P Speed). Default=373ms
    742-018 Full Stack Paper Sensing Condition 2  1~12 (1bit= 5sec) Full Stack Detection Condition (5~60sec). 
    742-019 Full Stack Paper Cancel Condition 1  1~30 (1bit= 1sec) Full Stack Cancel Condition (1~30sec)
    742-020 Feed Start Timing (MSI) 41  0~82 (1bit= 
    2.4462ms)Feed Start Timing Adjustment from Pitch (P Speed) (850~1050ms). Default=950ms 
    						
    							6/02
    6-23 DC1632/2240General Procedures and Information Prelaunch Training/Review 742-021 Feed Start Timing (MSI) (MF) 150 0~300 (1bit= 
    1.31136ms)Feed Start Timing Adjustment from Pitch (Double Speed) (100~500ms)
    742-022 Feed Motor Off Timing 10 0~35 
    (1bit= 10ms)Feed Motor Off Timing Adjustment from T/A Nip
    742-023 Regi Clutch Off Timing 41  0~81 
    (1bit= 2.4462ms)Adjusts the time between the paper rear edge has passes the Regi Sensor and the Regi Clutch Turns Off (P 
    Speed) (90~290ms). Default=190ms
    742-024 Regi Clutch Off Timing (MF) 76 0~152 
    (1bit= 1.31136ms)Adjusts the time between the paper rear edge has passes the Regi Sensor and the Regi Clutch Turns Off (Dou-
    ble Speed)
    742-025 ADJUST SIDE REGI (ALL) 25 0~50 
    (1bit= 0.211mm)Side Regi Adjustment (ALL, Offset value)
    742-026 ADJUST SIDE REGI (MSI) 20 0~50 
    (1bit= 0.211mm)Side Regi Adjustment (MSI)
    742-027 ADJUST SIDE REGI (Dup) 22 0~50
     (1bit= 0.211mm)Side Regi Adjustment (Dup)
    742-028 ADJUST LEAD REGI (ALL) 20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (ALL, Offset value)
    742-029 ADJUST LEAD REGI (Tray) 12 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (P Speed) from Tray
    742-030 ADJUST LEAD REGI (Tray) 20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (Double Speed) from Tray
    742-031 ADJUST LEAD REGI (MSI) (Standard 
    Paper)11 0 ~4 0  
    (1bit= 0.2544mm)Lead Regi Adjustment (P Speed) Standard Paper from Tray 5
    742-032 ADJUST LEAD REGI (MSI) (Standard 
    Paper)20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (Double Speed) Standard Paper from MSI
    742-033 ADJUST LEAD REGI (MSI)  (Heavy1) 20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (P Speed) Heavy Weight Paper 1 from Tray 5
    742-034 ADJUST LEAD REGI (MSI) (Heavy2) 20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (Half Speed) Heavy Weight Paper 2 from Tray 5 
    742-035 ADJUST LEAD REGI (MSI) (Heavy 
    Paper1)20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (Half Speed) Heavy Weight Paper 1 from Tray 5 
    742-036 ADJUST LEAD REGI (MSI) (Heavy 
    Paper2)20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (Half Speed) Heavy Weight Paper 2 from Tray 5
    742-037 ADJUST LEAD REGI (Dup) 11 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (P Speed) (Side2)
    742-038 ADJUST LEAD REGI (Dup)  20 0~40 
    (1bit= 0.2544mm)Lead Regi Adjustment (Double Speed) (Side2)
    742-039 Jam Bypass 0 0~255 0 =  Normal Mode  255 =  Jam Bypass
    742-040 OCT Start Timing (Offset) 42 0~202 
    (1bit= 2.4462ms)OCT (Offset) Start Timing Adjustment (P Speed)
    742-041 OCT Start Timing (Offset)  42 0~202 
    (1bit= 1.31136ms)OCT (Offset) Start Timing Adjustment (Double Speed)
    742-046 Face Up Tray Condition 0 0~1 Face Up Tray Present  0 =  No  1 =  Yes
    742-047 OCT Start Timing (Home) 17 0~112 
    (1bit= 2.4462ms)OCT (Home) Start Timing Adjustment (P Speed)Table 8 Chain 742
    Chain-Link Name Default Range Description 
    						
    							6/02
    6-24DC1632/2240 Prelaunch Training/Review General Procedures and Information742-048 OHP Sheet Sensing Condition 1 0~1 Transparency Detection 1 =  Detect 0 =  Does not detect
    742-049 Tray 5 Side Guide Min Data 972 927~1017 
    (1bit= 1mm)Saves the Tray 5 Size Detection Min Value
    742-050 Tray 5 Side Guide Max Data 52 7~97 (1bit= 1mm) Saves the Tray 5 Size Detection Max Value
    742-051 FEED START TIMING 1Tray 82 
    (450ms)0~163 
    (1bit= 2.4462ms)Adjusts the time between Pitch (Standard Signal IOT) and FEED Starts (250~650ms).
    742-052 FEED START TIMING 1Tray  82 0~163 
    (1bit= 1.31136ms)
    742-053 ADJUST SIDE REGI 1Tray 22 0~50 
    (1bit= 0.211mm)SIDE REGI Adjustment for each TRAY
    742-054 PAPER THE REST 1Tray 0 0~4000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-055 PRE T/A START TIMING 3TM-1 74 0~115 
    (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (303~803ms)
    742-056 PRE T/A START TIMING 3TM-2 74 0~115
     (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (365~865ms)
    742-057 PRE T/A START TIMING 3TM-3 74 0~115 
    (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (429~929ms)
    742-058 PRE T/A START TIMING TTM-1 10 0~16 
    (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
    742-059 PRE T/A START TIMING TTM-2 74 0~115 
    (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (457~957ms)
    742-060 PRE T/A START TIMING TTM-3 74 0~115 
    (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (431~931ms)
    742-061 PRE T/A START TIMING 1TM-1 102 0~204 
    (1bit= 2.4462ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (303~803ms). Default=553ms
    742-062 ADJUST PRE FEED POSITION 3TM-1 0  0~40 
    (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (0~400ms).
    742-063 ADJUST PRE FEED POSITION 3TM-2 0  0~40
     (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (0~400ms).
    742-064 ADJUST PRE FEED POSITION 3TM-3 0  0~40 
    (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (0~400ms).
    742-065 ADJUST PRE FEED POSITION TTM-1 0 0~40 
    (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (0~400ms).
    742-066 ADJUST PRE FEED POSITION TTM-2 0  0~40 
    (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (0~400ms).
    742-067 ADJUST PRE FEED POSITION TTM-3 37  10~50 
    (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (100~500ms). Default=370ms
    742-068 ADJUST PRE FEED POSITION 1TM-1 0  0~40 
    (1bit= 10ms)Adjust the Time between the FEED OUT SNR ON and the FEED MOT OFF (0~400ms).
    742-069 MAIN FEED START TIMING 3TM-1 20 0~44 
    (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (330~830ms).
    742-070 MAIN FEED START TIMING 3TM-2 20 0~44 
    (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (570~1070ms).Table 8 Chain 742
    Chain-Link Name Default Range Description 
    						
    							6/02
    6-25 DC1632/2240General Procedures and Information Prelaunch Training/Review 742-071 MAIN FEED START TIMING 3TM-3 20 0~44
     (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (810~1310ms).
    742-072 MAIN FEED START TIMING TTM-1 20 0~44
    (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (330~830ms).
    742-073 MAIN FEED START TIMING TTM-2 20 0~44 
    (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (780~1280ms).
    742-074 MAIN FEED START TIMING TTM-3 20 0~44 
    (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (1410~1910ms).
    742-075 MAIN FEED START TIMING 1TM-1 25  0~50 
    (1bit= 10ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (330~830ms).Default=580ms
    742-076 ADJUST SIDE REGI 2Tray 20 0~50 
    (1bit= 0.211mm)SIDE REGI adjustment of 2TRAY
    742-077 ADJUST SIDE REGI 3Tray 20 0~50
     (1bit= 0.211mm)SIDE REGI adjustment of 3TRAY
    742-078 ADJUST SIDE REGI 4Tray 20 0~50 
    (1bit= 0.211mm)SIDE REGI adjustment of 4TRAY
    742-079 ADJUST SIDE REGI TrayModuleAll 25 0~50 
    (1bit= 0.211mm)SIDE REGI adjustment of 2, 3, 4TRAY (Batch adjustment)
    742-080 PAPER THE REST 3TM-1 0 0~4000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-081 PAPER THE REST 3TM-2 0 0~4000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-082 PAPER THE REST 3TM-3 0 0~4000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-083 PAPER THE REST TTM-1 0 0~4000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-084 PAPER THE REST TTM-2 0 0~12000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-085 PAPER THE REST TTM-3 0 0~15000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-086 PAPER THE REST 1TM-1 0 0~4000 Saves the Cumulative LIFT UP Time from TRAY insertion (For remaining detection calculation as=A).
    742-087 OCT Condition 1 0~1 0 =  Not available, 1 =  Available
    742-088 Dup  On Timing (From Regi Start)  20 0~40 
    (1bit= 1.31136ms)Synchronize adjustment to be same as the Regi Clutch at Regi Start (Double Speed)
    742-089 OCT Start Timing (Home)  17 0~112 
    (1bit= 1.31136ms)OCT (Home) Start Timing Adjustment (Double Speed)
    742-093 PRE T/A START TIMING 3TM-1 139 0~215 
    (1bit= 1.31136ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (303~803ms)
    742-094 PRE T/A START TIMING 3TM-2 139 0~215
    (1bit= 1.31136ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (365~865ms)
    742-095 PRE T/A START TIMING 3TM-3 139 0~215 
    (1bit= 1.31136ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (429~929ms)
    742-096 PRE T/A START TIMING TTM-2 139 0~215 
    (1bit= 1.31136ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (457~957ms)
    742-097 PRE T/A START TIMING TTM-3 139 0~215 
    (1bit= 1.31136ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (431~931ms)
    742-098 MAIN FEED START TIMING 3TM-1 38 0~83 
    (1bit= 1.31136ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (330~830ms).
    742-099 MAIN FEED START TIMING 3TM-2 38 0~83 
    (1bit= 1.31136ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (570~1070ms).Table 8 Chain 742
    Chain-Link Name Default Range Description 
    						
    							6/02
    6-26DC1632/2240 Prelaunch Training/Review General Procedures and Information
    744--xxx User NVM List742-100 MAIN FEED START TIMING 3TM-3 38 0~83 
    (1bit= 1.31136ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (810~1310ms).
    742-101 MAIN FEED START TIMING TTM-2 38 0~83 
    (1bit= 1.31136ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (780~1280ms).
    742-102 MAIN FEED START TIMING TTM-3 38 0~83
    (1bit= 1.31136ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (1410~1910ms).
    742-103 Select A/B or INCH (SMH Auto Detect) 0 0~1 0 =  A/B series, 1 =  Inch series
    742-104 Select 2ndBTR Cleaning (SMH Auto 
    Detect)1 0~1 0 =  No, 1 =  Yes
    742-105 RegiLoopLengthAjust (DUP) (a sheet of 
    paper)41 0~81
    (1bit= 2.4462ms)Lead Regi Length Adjustment (P Speed) from Dup (Feeding Length Letter-LEF and longer)Default=157ms
    742-106 PRE T/A START TIMING 3TM-1 (Half) 37 0~58 
    (1bit= 4.8924ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (303~803ms)
    742-107 PRE T/A START TIMING 3TM-2 (Half) 37 0~58 
    (1bit= 4.8924ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (365~865ms)
    742-108 PRE T/A START TIMING 3TM-3 (Half) 37 0~58 
    (1bit= 4.8924ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (429~929ms)
    742-109 PRE T/A START TIMING TTM-2 (Half) 37 0~58 
    (1bit= 4.8924ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (457~957ms)
    742-110 PRE T/A START TIMING TTM-3 (Half) 37 0~58 
    (1bit= 4.8924ms)Adjusts the Time between PRE T/A Starts and Standard Signal (IOT) (431~931ms)
    742-111 MAIN FEED START TIMING 3TM-1 
    (Half)10 0~22 
    (1bit= 4.8924ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (330~830ms).
    742-112 MAIN FEED START TIMING 3TM-2 
    (Half)10 0~22
    (1bit= 4.8924ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (570~1070ms).
    742-113 MAIN FEED START TIMING 3TM-3 
    (Half)10 0~22
    (1bit= 4.8924ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (810~1310ms).
    742-114 MAIN FEED START TIMING TTM-2 
    (Half)10 0~22 
    (1bit= 4.8924ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (780~1280ms).
    742-115 MAIN FEED START TIMING TTM-3 
    (Half)10 0~22 
    (1bit= 4.8924ms)Adjust the Time between the MAIN FEED Starts and the PRE T/A (1410~1910ms).Table 8 Chain 742
    Chain-Link Name Default Range Description
    Table 9 Chain 744
    Chain-Link Name Default Range Description
    744-001 STS-1 CONT TEMP in Low PWR Mode 80 0~160 
    (1 bit=1 deg. C)Main-Lamp temperature control in Low-Power Mode. Setting the default as 0 Degrees Celsius is same as 
    Fuser-Off. It is necessary for high temperature for recovery Time Claim.
    744-002 STS-2 CONT TEMP in Low PWR Mode 80 0~160
    (1 bit=1 deg. C)Sub-Lamp temperature control in Low-Power Mode. Setting the default as 0 Degrees Celsius is same as Fuser-
    Off. It is necessary for high temperature for recovery Time Claim.
    744-003 UM status by High Temperature Error 
    Detection0 0~2 0 (Normal) or 1 (STS-1 High Temperature Error Detection) or 2 (STS-2 High Temperature Error Detection).UM 
    Status occurs when either STS-1 or STS-2 High Temperature Error Detection is detected. Once this occurs, UM 
    cannot be canceled unless this NVM value is changed to 0 by entering the Diag Mode in the Interlock-Open sta-
    tus of the M/C-Front Cover. 
    						