6/02 2-311 DC1632/2240 102-316, 102-317 Status Indicator RAPs Prelaunch Training/Review 102-316 Send Request Queue Full SIOOver the upper limit of the processing capability to send data from the Panel to the Controller. ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software. 102-317 Receive Message Queue FullThe data received from the Controller exceeded the upper limit of the processing capability in the Panel.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software.
6/02 2-312DC1632/2240 102-318, 102-319 Prelaunch Training/Review Status Indicator RAPs 102-318 Receive Finish Queue FullThe data received from the Controller exceeded the upper limit of the processing capability in the Panel.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software. 102-319 Send with No ACKSerial communication failure. Sending failure, ACK was not returned.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software.
6/02 2-313 DC1632/2240 102-320, 102-321 Status Indicator RAPs Prelaunch Training/Review 102-320 PollingSerial communication failure. Communication failure (polling error)ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software. 102-321 Send MessageSerial communication failure. Sending message error.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software.
6/02 2-314DC1632/2240 102-322, 102-323 Prelaunch Training/Review Status Indicator RAPs 102-322 TargetSerial communication failure. Target error.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software. 102-323 AddressSerial communication failure. Address error.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software.
6/02 2-315 DC1632/2240 102-324, 102-325 Status Indicator RAPs Prelaunch Training/Review 102-324 SizeSerial communication failure. Size errorProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software. 102-325 Object CreationObject creation error. The specified object failed to be created due to a setting or specifying error on gm_create.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software.
6/02 2-316DC1632/2240 102-326, 102-327 Prelaunch Training/Review Status Indicator RAPs 102-326 Memory OverflowMemory overflow. The memory in the GUAM exceeded the upper limit.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Expand the memory in the GUAM. If the problem continues, perform re-installation of the software. 102-327 Button OverflowButton overflow. The memory for the (synchronous display) button in the GUAM exceeded the upper limit.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Expand the memory for the button in the GUAM. If the problem continues, perform re-installation of the software.
6/02 2-317 DC1632/2240 102-328, 102-329 Status Indicator RAPs Prelaunch Training/Review 102-328 UI Internal with Out of AreaI/F failure in the UI. The coordination value out of the area of the displayed screen was detected (W x H = 640 x 240)ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check the D-RAM and ROM. If the problem continues, perform re-installation of the software. 102-329 UI Internal with Invalid CoordinatesI/F failure in the UI. The coordination value that cannot be displayed was detected (X = 4 times number position)ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check the D-RAM and ROM. If the problem continues, perform re-installation of the software.
6/02 2-318DC1632/2240 102-330, 102-331 Prelaunch Training/Review Status Indicator RAPs 102-330 Interface with Invalid Parameter LCDInterface failure. Incorrect parameter was detected at the Drv. I/F between the DM and LCD.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check the D-RAM and ROM. If the problem continues, perform re-installation of the software. 102-331 UI Internal with Invalid LED RequestI/F failure in the UI. The request for lighting up an incorrect LED was received.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check the D-RAM and ROM. If the problem continues, perform re-installation of the software.
6/02 2-319 DC1632/2240 102-332, 102-333 Status Indicator RAPs Prelaunch Training/Review 102-332 Interface with Invalid Parameter CPInterface failure. Incorrect parameter was detected at the Drv. I/F between the DM and CP.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check the D-RAM and ROM. If the problem continues, perform re-installation of the software. 102-333 Interface with Impossible CommunicationInterface failure. Impossible communication with the Control Panel was detected. H/W con- nection failure in the Panel, or the internal connection was unable to be detected correctly.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Perform re-installation of the software.
6/02 2-320DC1632/2240 102-334, 102-335 Prelaunch Training/Review Status Indicator RAPs 102-334 Interface with Receiving Error Key CodeInterface failure. Invalid Key Code was received from the Control Panel. ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Repair/adjust the Control Panel (PL 18.2) 102-335 Interface with Receiving Invalid CoordinatesInterface failure. Invalid coordination value was received from the Control Panel with a param- eter.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Repair/adjust the Control Panel (PL 18.2)