Home > Xerox > All in One Printer > Xerox 1632 2240 3535 Color Carrera Manual

Xerox 1632 2240 3535 Color Carrera Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Xerox 1632 2240 3535 Color Carrera Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 228 Xerox manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1064
    							6/02
    2-301 DC1632/2240
    16-965, 16-966Status Indicator RAPs Prelaunch Training/Review
    16-965  ATS/APS No PaperAPS/ATS NG No Paper.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Add paper.
    16-966  ATS/APS No DestinationATS/APS No Destination, other than No Paper.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Change the settings and replace the Trays. 
    						
    							6/02
    2-302DC1632/2240
    16-981, 16-982
    Prelaunch Training/Review Status Indicator RAPs
    16-981  Full HDFull status was detected at HD access.  Full status was not cleared even during waiting for tim-
    ing.  One or more pages are already stored.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Service actions depend on the operation specifications.
    Again, switch power off then on.
    If the problem continues, reload software.
    If the problem continues, replace the HD (PL 13.1). 
    16-982  Full HDFull status was detected at HD access.  Full status was not cleared even during waiting for tim-
    ing.  No pages can be stored.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Again, switch power off then on. 
    						
    							6/02
    2-303 DC1632/2240
    102-200, 102-201
    Status Indicator RAPs Prelaunch Training/Review
    102-200  Receive Buffer OverflowThe data received from the Controller exceeded the buffer amount of the destination in the
    Panel.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    If the problem continues, replace the ESS PWB (PL 13.1) 
    102-201  Send Buffer OverflowThe data to be sent from the Panel exceeded the buffer amount of the destination in the Panel.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    If the problem continues, replace the ESS PWB (PL 13.1) 
    						
    							6/02
    2-304DC1632/2240
    102-202, 102-203
    Prelaunch Training/Review Status Indicator RAPs
    102-202  Request Queue FullThe event that requires more than the processing capability for the request arising in the Panel
    has occurred.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    If the problem continues, replace the ESS PWB (PL 13.1)
    102-203  Send Request Queue Full DebugData cannot be sent from the Panel to the Controller.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    If the problem continues, replace the ESS PWB (PL 13.1) 
    						
    							6/02
    2-305 DC1632/2240
    102-204, 102-205
    Status Indicator RAPs Prelaunch Training/Review
    102-204  SIO ParameterSerial communication failure.  Incorrect message size at SIO receiving request, or incorrect
    Mailbox ID when a message is sent.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    102-205  SIO CommandSerial communication failure.  A command error has occurred at SIO receiving request.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software. 
    						
    							6/02
    2-306DC1632/2240
    102-206, 102-207
    Prelaunch Training/Review Status Indicator RAPs
    102-206  SIO StatusSerial communication failure.  A header status error of the RX packet or a message status error
    of the RX packet has occurred.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    102-207  Communication Manager TargetSerial communication failure.  Incorrect Mailbox value on the cm_send_msg statement, or the
    target is not SYS when receiving from SIO.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software. 
    						
    							6/02
    2-307 DC1632/2240
    102-208, 102-209
    Status Indicator RAPs Prelaunch Training/Review
    102-208  Communication Manager CommandSerial communication failure.  A command error has occurred when receiving from SIO.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    102-209  EVM Returns Wrong ValueReturn value error from EVM.  Panel-SW failureProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software. 
    						
    							6/02
    2-308DC1632/2240
    102-310, 102-311
    Prelaunch Training/Review Status Indicator RAPs
    102-310  Send Queue FullOver the upper limit of the processing capability to send data from the Panel to the Controller. ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    102-311  Receive Queue FullThe data received from the Controller exceeded the upper limit of the processing capability in
    the Panel.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software. 
    						
    							6/02
    2-309 DC1632/2240
    102-312, 102-313
    Status Indicator RAPs Prelaunch Training/Review
    102-312  EVM Uses Wrong APIIllegal use of API by EVM.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    102-313  AS Uses Wrong APIIllegal use of API by ASProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software. 
    						
    							6/02
    2-310DC1632/2240
    102-314, 102-315
    Prelaunch Training/Review Status Indicator RAPs
    102-314  Wait Event Time OutTime-Out of the event waiting timer.  The response message from the Controller was not noti-
    fied for a specified time.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software.
    102-315  CTS InternalCTS Internal ErrorProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Perform re-installation of the software. 
    						
    All Xerox manuals Comments (0)