    1-302
    Status Indicator RAPs Prelaunch Training/Review
    1-302 RAPFront Cover or is openInitial ActionsCheck the operation of the Actuator and the switch.ProcedureOpen the Front Cover.  Cheat the Front Cover Interlock Switch. 001-302 is cleared.
    YN
    +24VDC is measured between the I/F PWB j531-1 (+) and GND (-).
    YN
    +24VDC is measured between the Front Cover Interlock Switch j171-B1 (+) and
    GND (-).
    YN
    24VDC is measured between the Front Cover Interlock Switch j171-A1 (+)
    and GND (-).
    YN
    Repair the open circuit between the Left Cover Interlock Switch j172-B1
    and the Front Interlock Switch j171-A1.
    Replace the Front Cover Interlock Switch.
    +24VDC is measured between the RH Cover Interlock Switch j173-B1 (+) and
    GND (-).
    YN
    +24VDC is measured between the RH Cover Interlock Switch j173-A1 (+)
    and GND (-).
    YN
    Repair the open circuit between the Front Cover Interlock Switch j171-B1
    and the RH Cover Interlock Switch j173-A1.
    Replace the RH Cover Interlock Switch.
    Check the wire for an open circuit between the RH Cover Interlock Switch j173-B1
    and the Interlock Relay PWB j569-2.
    Check the wire for an open circuit between the Interlock Relay PWB j569-1 and the I/
    F PWB j531-1.
    Replace the I/F PWB (PL 9.1). 
    If the problem continues, replace the MCU PWB (PL 13.1). 
    Check installation of Cover/Actuator. Figure 1 Front Cover / Right Cover Interlock CD
    Figure 2 Front Cover Interlock Switch Location
    Figure 3 Left Cover Interlock Switch Location
    Front Cover 
    Interlock Switch
    Left Cover 
    Interlock Switch 
    						
    							6/02
    2-12DC1632/2240
    1-303
    Prelaunch Training/Review Status Indicator RAPs
    1-303 RAPHCF Left Door is open.ProcedureEnter dC330 [001-304] and press Start.  Actuate Tray Module LH Cover Interlock Switch with a
    screwdriver. Display changes state.
    YN
    Check voltage between Tray Module PWB j554-3(+) and GND(-). +24 VDC is mea-
    sured.
    YN
    Check the wires from the Tray Module PWB j554-3 to Tray Module L/H Cover Inter-
    lock Switch FS813 for damage.  If the wires are good, replace Tray Module L/H
    Cover Interlock Switch (PL 15.10).
    Replace Tray Module PWB (PL15.9).
    Check Cover Actuator and Cover installation.
    Figure 1 Tray Module LH Cover Interlock Switch Cd 
    						
    							6/02
    2-13 DC1632/2240
    1-306
    Status Indicator RAPs Prelaunch Training/Review
    1-306 RAPDuplex Door is open.ProcedureEnter dC330 [008-300] and press Start.  Open Duplex Transport.  Actuate Duplex Cover Inter-
    lock Switch with a screwdriver. Display changes state.
    YN
    Deactuate Duplex Cover Interlock Switch.  Check voltage on the Drawer Connector
    between j626-A6 (+) and GND(-). +5 VDC is measured.
    YN
    Check voltage between MCU PWB j406-A9 and GND(-). +5 VDC is measured.
    YN
    Replace MCU PWB (PL13.1).
    Repair the open circuit between the MCU PWB j406-A9 and Drawer Connector
    between j626-A6
    Check the wires between Drawer Connector between j626-A6 and Duplex PWB j540-1.  If
    the wires are good, replace the Duplex Cover Interlock Switch.
    Check Cover Actuator and Cover installation. If there is no problem, replace MCU PWB
    (PL13.1)
    Figure 1 Duplex Cover Interlock Switch 
    						
    							6/02
    2-14DC1632/2240
    1-306
    Prelaunch Training/Review Status Indicator RAPs 
    						
    							6/02
    2-15 DC1632/2240
    3-317 , 3-318
    Status Indicator RAPs Prelaunch Training/Review
    3-317 IIT Software FailureConfiguration mismatchProcedureChange the position of the document sensor. The problem is corrected. 
    YN
    Rewrite the NVM values.
    Return to Service Call Procedures.
    3-318 IIT Software FailureProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the ESS PWB connectors. If the
    check is OK, replace the ESS PWB (PL 13.1).
    Return to Service Call Procedures. 
    						
    							6/02
    2-16DC1632/2240
    3-319 , 3-320
    Prelaunch Training/Review Status Indicator RAPs
    3-319 IIT Video Driver FailureProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the ESS PWB connectors. If the
    check is OK, replace the ESS PWB (PL 13.1).
    Return to Service Call Procedures.
    3-320 IIT-ESS Communication Failure 1Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures. 
    						
    							6/02
    2-17 DC1632/2240
    3-321, 3-322
    Status Indicator RAPs Prelaunch Training/Review
    3-321 IIT-ESS Communication Failure 2Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures.
    3-322 IIT-ESS Communication Failure 3Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures. 
    						
    							6/02
    2-18DC1632/2240
    3-323, 3-324
    Prelaunch Training/Review Status Indicator RAPs
    3-323 IIT-ESS Communication Failure 4Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures.
    3-324 IIT-ESS Communication Failure 5Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures. 
    						
    							6/02
    2-19 DC1632/2240
    3-325, 3-326
    Status Indicator RAPs Prelaunch Training/Review
    3-325 IIT-ESS Communication Failure 6Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures.
    3-326 IIT-ESS Communication Failure 7Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures. 
    						
    							6/02
    2-20DC1632/2240
    3-327, 3-328
    Prelaunch Training/Review Status Indicator RAPs
    3-327 IIT-ESS Communication Failure 8Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures.
    3-328 IIT-ESS Communication Failure 9Controller received check code error.ProcedureSwitch the power off then on. The problem is corrected. 
    YN
    Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
    check is OK, replace the IIT/IPS PWB (PL 18.3).
    Return to Service Call Procedures. 
    						