    15-362, 15-367Status Indicator RAPs Prelaunch Training/Review
    15-362 X Hard FailureCommunication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3). If the check ia OK, replace the IIT/IPS
    PWB (PL 18.3). 
    15-367 X PIO FailureCommunication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3). If the check ia OK, replace the IIT/IPS
    PWB (PL 18.3).  
    						
    							6/02
    2-252DC1632/2240
    15-370, 15-371
    Prelaunch Training/Review Status Indicator RAPs
    15-370 X PIO Initialization Failure 1Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check
    ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL
    18.3).
    15-371 X PIO Initialization Failure 2Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check
    ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL
    18.3). 
    						
    							6/02
    2-253 DC1632/2240
    15-372, 15-375Status Indicator RAPs Prelaunch Training/Review
    15-372 X PIO Initialization Failure 3Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check
    ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL
    18.3).
    15-375 X PIO Before Scan Failure Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check
    ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL
    18.3). 
    						
    							6/02
    2-254DC1632/2240
    15-376, 15-377
    Prelaunch Training/Review Status Indicator RAPs
    15-376 X PIO Non-match Failure 1Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check
    ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL
    18.3).
    15-377 X PIO Non-match Failure 2 Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Return to Service Call Procedures.
    Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check
    ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL
    18.3). 
    						
    							6/02
    2-255 DC1632/2240
    15-380, 15-381Status Indicator RAPs Prelaunch Training/Review
    15-380 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 1 red failed.Initial Actionsï Verify that Platen Glass is installed correctly.
    ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required.
    Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates.
    YN
    Go to the 6-371 Exposure Lamp RAP.
    The Exposure Lamp illumination is bright and steady. 
    YN
    Go to p/j722 and p/j724 on BSD 6.1 and check the wires for an open or short circuit.
    Verify that j742 on the Lamp Ballast PWB and p/j724 on the IIT/IPS PWB are seated.
    If the wires and connectors are good, replace the Exposure Lamp (PL 18.6).
    If the problem continues, replace the Lamp Ballast PWB (PL 18.6).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3).
    Remove the Platen Glass (REP 6.2).   The white reference strip on the bottom of the
    Platen Glass is clean and undamaged.
    YN
    Clean the white reference strip or replace the Platen Glass (PL 18.3).
    Go to p/j721 on BSD 6.2 and check the flat cable on the IIT/IPS PWB and j741 on the CCD
    PWB for damage.  Reseat the flat cable.
    If the problem continues, replace the Lens Kit (PL 18.4).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3).
    15-381 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 2 red failed.Initial Actionsï Verify that Platen Glass is installed correctly.
    ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required.
    Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates.
    YN
    Go to the 6-371 Exposure Lamp RAP.
    The Exposure Lamp illumination is bright and steady. 
    YN
    Go to p/j722 and p/j724 on BSD 6.1 and check the wires for an open or short circuit.
    Verify that j742 on the Lamp Ballast PWB and p/j724 on the IIT/IPS PWB are seated.
    If the wires and connectors are good, replace the Exposure Lamp (PL 18.6).
    If the problem continues, replace the Lamp Ballast PWB (PL 18.6).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3).
    Remove the Platen Glass (REP 6.2).   The white reference strip on the bottom of the
    Platen Glass is clean and undamaged.
    YN
    Clean the white reference strip or replace the Platen Glass (PL 18.3).
    Go to p/j721 on BSD 6.2 and check the flat cable on the IIT/IPS PWB and j741 on the CCD
    PWB for damage.  Reseat the flat cable.
    If the problem continues, replace the Lens Kit (PL 18.4).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3). 
    						
    							6/02
    2-256DC1632/2240
    15-382, 15-383
    Prelaunch Training/Review Status Indicator RAPs
    15-382 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 3 green failed.Initial Actionsï Verify that Platen Glass is installed correctly.
    ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required.
    Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates.
    YN
    Go to the 6-371 Exposure Lamp RAP.
    The Exposure Lamp illumination is bright and steady. 
    YN
    Go to p/j722 and p/j724 on BSD 6.1 and check the wires for an open or short circuit.
    Verify that j742 on the Lamp Ballast PWB and p/j724 on the IIT/IPS PWB are seated.
    If the wires and connectors are good, replace the Exposure Lamp (PL 18.6).
    If the problem continues, replace the Lamp Ballast PWB (PL 18.6).
    If the problem continues, replace the IIT Driver PWB (PL 18.3).
    Remove the Platen Glass (REP 6.2).   The white reference strip on the bottom of the
    Platen Glass is clean and undamaged.
    YN
    Clean the white reference strip or replace the Platen Glass (PL 18.3).
    Go to p/j721 on BSD 6.2 and check the flat cable on the IIT/IPS PWB and j741 on the CCD
    PWB for damage.  Reseat the flat cable.
    If the problem continues, replace the Lens Kit (PL 18.4).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3).
    15-383 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 4 green failed.Initial Actionsï Verify that Platen Glass is installed correctly.
    ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required.
    Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates.
    YN
    Go to the 6-371 Exposure Lamp RAP.
    The Exposure Lamp illumination is bright and steady. 
    YN
    Go to p/j722 and p/j724 on BSD 6.1 and check the wires for an open or short circuit.
    Verify that j742 on the Lamp Ballast PWB and p/j724 on the IIT/IPS PWB are seated.
    If the wires and connectors are good, replace the Exposure Lamp (PL 18.6).
    If the problem continues, replace the Lamp Ballast PWB (PL 18.6).
    If the problem continues, replace the IIT Driver PWB (PL 18.3).
    Remove the Platen Glass (REP 6.2).   The white reference strip on the bottom of the
    Platen Glass is clean and undamaged.
    YN
    Clean the white reference strip or replace the Platen Glass (PL 18.3).
    Go to p/j721 on BSD 6.2 and check the flat cable on the IIT/IPS PWB and j741 on the CCD
    PWB for damage.  Reseat the flat cable.
    If the problem continues, replace the Lens Kit (PL 18.4).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3). 
    						
    							6/02
    2-257 DC1632/2240
    15-384, 15-385Status Indicator RAPs Prelaunch Training/Review
    15-384 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 5 blue failed.Initial Actionsï Verify that Platen Glass is installed correctly.
    ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required.
    Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates.
    YN
    Go to the 6-371 Exposure Lamp RAP.
    The Exposure Lamp illumination is bright and steady. 
    YN
    Go to p/j722 and p/j724 on BSD 6.1 and check the wires for an open or short circuit.
    Verify that j742 on the Lamp Ballast PWB and p/j724 on the IIT/IPS PWB are seated.
    If the wires and connectors are good, replace the Exposure Lamp (PL 18.6).
    If the problem continues, replace the Lamp Ballast PWB (PL 18.6).
    If the problem continues, replace the IIT Driver PWB (PL 18.3).
    Remove the Platen Glass (REP 6.2).   The white reference strip on the bottom of the
    Platen Glass is clean and undamaged.
    YN
    Clean the white reference strip or replace the Platen Glass (PL 18.3).
    Go to p/j721 on BSD 6.2 and check the flat cable on the IIT/IPS PWB and j741 on the CCD
    PWB for damage.  Reseat the flat cable.
    If the problem continues, replace the Lens Kit (PL 18.4).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3).
    15-385 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 6 blue failed.Initial Actionsï Verify that Platen Glass is installed correctly.
    ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required.
    Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates.
    YN
    Go to the 6-371 Exposure Lamp RAP.
    The Exposure Lamp illumination is bright and steady. 
    YN
    Go to p/j722 and p/j724 on BSD 6.1 and check the wires for an open or short circuit.
    Verify that j742 on the Lamp Ballast PWB and p/j724 on the IIT/IPS PWB are seated.
    If the wires and connectors are good, replace the Exposure Lamp (PL 18.6).
    If the problem continues, replace the Lamp Ballast PWB (PL 18.6).
    If the problem continues, replace the IIT Driver PWB (PL 18.3).
    Remove the Platen Glass (REP 6.2).  The white reference strip on the bottom of the
    Platen Glass is clean and undamaged.
    YN
    Clean the white reference strip or replace the Platen Glass (PL 18.3).
    Go to p/j721 on BSD 6.2 and check the flat cable on the IIT/IPS PWB and j741 on the CCD
    PWB for damage.  Reseat the flat cable.
    If the problem continues, replace the Lens Kit (PL 18.4).
    If the problem continues, replace the IIT/IPS PWB (PL 18.3). 
    						
    							6/02
    2-258DC1632/2240
    15-790
    Prelaunch Training/Review Status Indicator RAPs
    15-790 X Detail Failure Communication Failure.ProcedureSwitch the power off then on. The problem continues.
    YN
    Check the connectors on the IIT/IPS PWB (PL 18.3). If the check ia OK, replace the IIT/
    IPS PWB (PL 18.3).
    Return to Service Call Procedures. 
    						
    							6/02
    2-259 DC1632/2240
    16-311, 16-315Status Indicator RAPs Prelaunch Training/Review
    16-311 ScannerScanner not detected during power up.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Check connections between Scanner and IOT. Service as required (PL 18.3) (PL 18.4).
    16-315  IIT InterfaceIIT interface error.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Pivot down T5 T6 HVPS (REP 1.6) to access I/F PWB. 
    Check that connections on I/F PWB are secure.
    If problem continues, replace I/F PWB (PL 9.1). 
    						
    							6/02
    2-260DC1632/2240
    16-316, 16-317
    Prelaunch Training/Review Status Indicator RAPs
    16-316  Page MemoryPage memory not detected.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Check installation of Page Memory of the Scanner.
    16-317  Page MemoryPage Memory error.ProcedureSwitch power off then on. The problem continues.
    YN
    Return to service call procedures.
    Replace the Page Memory of the Scanner. 
    						
    All Xerox manuals Comments (0)