    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-009
     TROUBLESHOOTING OF EC H221 MUX UNIT
    GENERAL: 
    Sectionalization of failure is conducted by the front lamp (LED) 
    indication of EC H221 MUX unit.
    APPARATUS: 
    None
    STEP PROCEDURE REFERENCE NO.
    Note:
    Location of SWs, Straps, LEDs, and list of LED function are shown 
    in GSD-004
    .
    1 Is FUN ER (RC10) or MEM ER (RC 9)LED lit?
    If YES
    , the EC H221 MUX unit is faulty. Replace it.
    If NO
    , go to Step 2
    .TCP-017
    2 Is REC (RC16) LED or REM ALM (RC15) LED lit?
    If YES
    , go to Step 3
    .
    If NO
    , the EC H221 MUX unit is normal.
    3 Verify that the power of VL5000 is in on.
    If YES
    , go to Step 4
    .
    If NO
    , turn on the power.  Then, go to Step 4
    .
    4 Verify that parameter setting of VL5000 is correct.
    If YES
    , go to Step 5
    .
    If NO
    , set the correct parameters.  Then, go to Step 5
    .
    5 Set the MUX strap terminal of this unit to OFF
    .
    6 Set the MLB strap terminal of this unit to ON
    .
    (Loopback is set on the EC H 221 MUX unit)
    Note:
    Performing Steps 5
     and 6
    , it becomes possible to loopback video and 
    audio signals and Low Speed Data to the line side without 
    substituting the H 221 synchronizing signal. 
    7 Verify that low speed data, video, and audio signals of its local station can be 
    received at each conference  room by requesting the remote loop using the 
    RLCS 
    command  (refer to NECA 340-414-300
    ).
    If YES
    , go to Step 8
    .
    If NO
    , the EC H221 MUX  unit is faulty. Replace it.TCP-002
    COP-177
    TCP-017 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-009 MCU 5000A Multipoint Control Unit
    TROUBLESHOOTING OF EC H221 MUX UNIT
    STEP PROCEDURE REFERENCE NO.
    8 Set the MUX strap terminal of this unit to 
    ON.
    Note:
    By doing this, it becomes possible that the H221 synchronizing 
    signal is substituted and Low Speed Data, video and audio signals 
    are looped back to the line side.
    9
    Verify that low speed data, video, and audio signals of local station can be 
    received at each conference room by requesting the remote loop using the 
    RLCS command.
    If 
    YES, perform the troubleshooting of the V SW/LSD IF unit.
    If 
    NO, the EC H221 MUX unit is faulty. Replace it.TCP-002
    COP-146
    TCP-010
    TCP-017
    10 Verify that switch and strap settings of this unit are correct.
    If 
    YES, go to 
    Step 11.
    If 
    NO, set the correct position.  Then, go to 
    Step 5.
    11 End of procedure. 
    						
    							NECA 340-4 14- 50 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   TCP-010
    TR OUBLESHO OTING OF PG/SIO UNIT 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-010 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-011
      TROUBLESHOOTING OF V SW/LSD IF UNIT
    GENERAL: 
    Sectionalization of failure is performed by the LED indication of V SW/
    LSD IF unit.
    APPARATUS: 
    None
    STEP PROCEDURE REFERENCE NO.
    Note 1:
    Location of SWs, Straps, LEDs, and list of LED function 
    are shown in GSD-005
    .
    Note 2:
    These do not indicate failure conditions directly but may 
    be an aid to failure sectionalization.
    Note 3:
    When a failure has happened to the visual communication, 
    perform the troubleshooting checking  LEDs of this unit.
    1 Verify that the ARM LED of V SW/LSD IF unit is lit.
    If YES
    , go to Step 2
    .
    If NO
    , go to Step 3
    .
    2 When the ARM LED of this unit is lit.
    It lights up when the judgment of abnormality is given as a result of loopback 
    pattern comparison at the time of MCU loop test.
    Then, go to Step 12
    .TCP-004
    3 Check the lighting condition of LEDs on the V SW/LSD IF unit.
    4 Does CONF A LED light when group A communication is performed?
    (Does CONF B LED light when group B communication is performed?)
    If YES
    , go to Step 6
    .
    If NO
    , go to Step 5
    .
    5 Turn the toggle switch to CONF A =Conference A  (CONF B = conference 
    B), and then verify the state of LED.
    If it is lit, go to Step 7
    .
    If not, go to Step 6
    .
    6 Check the power-up and setup of VL 5000s in the participating conference 
    rooms. 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-011 MCU 5000A Multipoint Control Unit
    TROUBLESHOOTING OF V SW/LSD IF UNIT
    STEP PROCEDURE
    REFERENCE NO.
    7 Are broadcast sending station LEDs (TX1 to 8) lit?
    If YES, go to 
    Step 11.
    If 
    NO, go to 
    Step 8.
    8 Request the system operator to send the voice signal from the conference room 
    (send his own voice).
    9 Are broadcast sending station LEDs (TX 1to 8) lit?
    If 
    YES, go to 
    Step 11.
    If 
    NO, go to 
    Step 12.
    10 This unit operates normally.  Then, go to 
    Step 12.
    11 The V SW/LSD IF unit is faulty. Replace it.TCP-017
    12 End of procedure. 
    						
    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-012
     TROUBLESHOOTING OF A CODEC UNIT
    GENERAL: 
    Sectionalization of failure is performed by the LED indication of A 
    CODEC unit.
    APPARATUS: 
    None
    STEP PROCEDURE REFERENCE NO.
    Note: 1:
    Location of SWs, Straps, LEDs, and list of LED function are shown 
    in GSD-006
    .
    Note 2:
    These do not indicate failure conditions directly but may be an aid to 
    failure sectionalization.
    Note 3:
    When  a failure has happened to the audio system, perform the 
    troubleshooting checking LEDs of this unit.
    1 Start up the system and request each conference room to talk into the 
    microphone more loudly than usual.
    2 Are LEDs (RC 1 to 4) of the A CODEC unit corresponding to the conference 
    rooms lit?
    If YES
    , go to Step 3
    .
    If No
    , go to Step 4
    .
    3 Perform the troubleshooting of the A SUM unit.  Then, go to Step 5
    .TCP-013
    4 The A CODEC unit is faulty. Replace it.TCP-017
    5 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-012 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-013
    TROUBLESHOOTING OF A SUM UNIT
    GENERAL:  
    Sectionalization of failure is performed on the A SUM unit.
    APPARATUS: 
    Level Meter or Speaker with amplifier
    Figure 1:   Monitoring of Audio Signal
    STEP PROCEDURE REFERENCE NO.
    Note 1:
    Location of SWs, Straps, LEDs, and list of LED function are 
    shown in GSD-007
    .
    Note 2:
    These do not indicate failure conditions directly but may be an aid 
    to failure sectionalization.
    Note 3:
    This troubleshooting is performed when a failure has happened to 
    the audio system. Request each conference room to talk into the 
    microphone and start the  procedure after checking to see that the 
    LEDs of the A CODEC unit corresponding to the conference 
    rooms are lit.
    1 Connect a level meter or speaker with amplifier to the monitor terminal on the 
    unit (see Fig. 1).
    2 Monitor with level meter or speaker with amplifier, and verify that the signal 
    is monitored. 
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 4
    .
    3 The A CODEC unit is faulty. Replace it.  Then, go to Step 5
    .
    4 The A SUM unit is faulty. Replace it.
    5 Disconnect the level meter or speaker with amplifier from the monitor 
    terminal.
    6 End of procedure.
    SPEAKER OR
    MON
    A SUM UNIT
    600 ohm BALANCE
    LEVEL METER 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0