    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-048
    MBE MESSAGE (AUDIO) MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY: 
    Set expansion audio devices to be used in communication with the connecting 
    CODECs (VL 5000s).
    STEP PROCEDURE 
    Note:
    MCU 500A does not support MBE message (audio) mode.  Be sure, therefore, to set all the 
    system parameters to OFF (00H 00H)
    .  If change is necessary for any reason, follow the steps 
    described below.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address138H 
    and 139H
    [1] Addresses (hexadecimal values) on setting the MBE message (audio) mode.
    The MBE message (audio) mode is set in hexadecimal values by dividing the 16 bits 
    (b0 to b15) into the upper-half and lower-half 8 bits.
    ADDRESS MBE MESSAGE (AUDIO) MODE
    138H  Lower-half 8 bits setting address (b0 to b7)
    139H Upper-half 8 bits setting address (b8 to b15)
    xi:
    System parameter values See  below:
    [1] System parameter values on setting the MBE message (audio) mode for the addresses 
    138H and 139H.
    The factory shipment value for the system parameter is 00H
     00H
    .
    SYSTEM PARAMETER
    MBE MESSAGE (AUDIO) MODE SETTING
    ADDRESS
    139HADDRESS
    138H
    00H 00H OFF 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-048 MCU 5000A Multipoint Control Unit
    MBE MESSAGE (AUDIO) MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-049
    MBE MESSAGE (LSD2) MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY: 
    Set expansion LSD (Low Speed Data) devices to be used in communication with 
    the connecting CODECs (VL 5000s)
    STEP PROCEDURE 
    Note:  
    MCU 5000A does not support LSD2.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address13AH 
    and 13BH
    [1] Addresses (hexadecimal values) on setting the MBE message (LSD2) mode.
    The MBE message (LSD2) mode is set in hexadecimal values by dividing the 16 bits 
    (b0 to b15) into the upper-half and lower-half 8 bits, or specially by setting any of bit 
    0, bit 2, or bit 3 in the lower-half 8 bits to “1” or “0”.  Accordingly, since the upper-
    half 8 bits are always 00H
    , set only the lower-half 8 bits (address 13AH).
    ADDRESS MBE MESSAGE (LSD2) MODE
    13AH  Lower-half 8 bits setting address (b0 to b7)
    13BH Upper-half 8 bits setting address (b8 to b15)
    xi:
    System parameter values See  below:
    [1] System parameter values on setting the MBE message (LSD2) mode for the 
    addresses 13AH and 13BH.
    The factory shipment value for the system parameter is 00H
     00H
    . 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-049 MCU 5000A Multipoint Control Unit
    MBE MESSAGE (LSD2) MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETER
    MBE MESSAGE (LSD2) MODE SETTING
    ADDRESS
    13BHADDRESS
    13AH
    00H 00H OFF
    00H 01H 1200 b/s is ON.
    00H 04H 4800 b/s is ON.
    00H 08H 9600 b/s is ON.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-050
    MBE MESSAGE (VIDEO) MODE SETTING
    TERMINAL MODE RELATED 
    SUMMARY:
    Set expansion video devices to be used in communication with the connecting   
    CODECs (VL 5000s).
    STEP PROCEDURE 
    Note:
    Set “PTY
    ” and “FULL
    ” to OFF
     as a general rule.  Set “VSP
    ” to ON
     when the dual screen 
    multiplex function is used at the connecting terminals, and OFF
     when it is not used.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address13CH 
    and 13DH
    [1] Addresses (hexadecimal values) on setting the MBE message (video) mode.
    The MBE message (video) mode is set in hexadecimal values by dividing the 16 bits 
    (b0 to b15) into the upper-half and lower-half 8 bits, or specifically by setting any of 
    bit 1 through bit 3 in the lower-half 8 bits to “1” or “0”.  Accordingly, since the upper-
    half 8 bits are always “00H”, set only the lower-half 8 bits (address 13CH).
    ADDRESS MBE MESSAGE (VIDEO) MODE
    13CH  Lower-half 8 bits setting address (b0 to b7)
    13DH Upper-half 8 bits setting address (b8 to b15) 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-050 MCU 5000A Multipoint Control Unit
    MBE MESSAGE (VIDEO) MODE SETTING
    TERMINAL MODE RELATED 
    STEP PROCEDURE 
    x
    i:
    System parameter values See  below:
    [1] System parameter values on setting the MBE message (video) mode for the address 
    13CH and 13DH.
    The factory shipment value for the system parameter is 06H
     00H
    .
    SYSTEM PARAMETER
     
    MBE MESSAGE (VIDEO) MODE SETTING
    ADDRESS
    13DHADDRESS
    13CH
    00H 00H OFF
    00H 01H PTY is ON.
    00H 02H FULL is ON.
    00H 03H PTY and FULL are ON.
    00H 04H VSP is ON.
    00H 05H PTY and VSP are ON.
    00H 06H FULL and VSP are ON.
    00H 07H PTY, FULL and VSP are ON.
    Note:
    PTY detects a parity error and performs Demand Refresh on  its occurrence.
    FULL: NTSC full resolution mode 
    VSP: dual screen multiplex mode
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-101
    AUDIO CAPABILITY
    TERMINAL CAPABILITY RELATED
    RCON (H.243 mode) 
    Group A and Group B:A: means Group A and B: means Group B.
    Audio Capability (A: +200H ~ +203H) (B: +260H ~ +263H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    b1 :  m -Law, OF (F6)Default = 0AH A: +200H
    0 fixed
    0 fixed 0 fixed 0 fixed 1
    010 fixed
    b6 : G.722-64k
    b7 : G.722-48k B: +260H
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixed0 fixed A: +201H
    B: +261H
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixed0 fixed A: +202H
    B: +262H
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixed0 fixed A: +203H
    B: +263H 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-101 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-102
    TRANSFER RATE CAPABILITY
    TERMINAL CAPABILITY RELATED
    Transfer Rate Capability (A: +204H ~ 207H) (B: +264H ~ +267H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    b0 : 64 kbps              (T1/RS422/INF-H0)
    b1 : 64 x 2 kbps        (T1/RS422/INS-H0)Default = C2 11
    0 fixed0 fixed 0 fixed0 fixed 1
    0
    b6 : 128 kbps             (T1/RS422)
    b7 : 192 kbps             (T1/RS422) A: +204H
    B: +264H
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = C5H 11
    0 fixed0 fixed 0 fixed1
    0
    1 A: +205H
    B: +265H
    b0 : 256 kbps                   (T1/RS422)
    b1 : 384 kbps                  (T1/RS422/INS-H0)
    b2 : 384 x 2 kbps            (T1/RS422/INF-H0)
    b6 : 512 kbps                   (T1/RS422)
    b7 : 768 kbps                   (T1/RS422)
    b7
    b6b5
    b4 b3 b2 b1 b0
    b0 : 1152 kbps                  (T1/RS422)
    b1 : 1472 kbps                  (T1)Default = 0FH 11
    1
    1
    b2 : 1536 kbps                  (T1/RS422)
    b3 : 1920 kbps                  (RS422) A: +206H
    B: +266H
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H A: +207H
    B: +267H 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-102 MCU 5000A Multipoint Control Unit