NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-048 MBE MESSAGE (AUDIO) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set expansion audio devices to be used in communication with the connecting CODECs (VL 5000s). STEP PROCEDURE Note: MCU 500A does not support MBE message (audio) mode. Be sure, therefore, to set all the system parameters to OFF (00H 00H) . If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address138H and 139H [1] Addresses (hexadecimal values) on setting the MBE message (audio) mode. The MBE message (audio) mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits. ADDRESS MBE MESSAGE (AUDIO) MODE 138H Lower-half 8 bits setting address (b0 to b7) 139H Upper-half 8 bits setting address (b8 to b15) xi: System parameter values See below: [1] System parameter values on setting the MBE message (audio) mode for the addresses 138H and 139H. The factory shipment value for the system parameter is 00H 00H . SYSTEM PARAMETER MBE MESSAGE (AUDIO) MODE SETTING ADDRESS 139HADDRESS 138H 00H 00H OFF
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-048 MCU 5000A Multipoint Control Unit MBE MESSAGE (AUDIO) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-049 MBE MESSAGE (LSD2) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set expansion LSD (Low Speed Data) devices to be used in communication with the connecting CODECs (VL 5000s) STEP PROCEDURE Note: MCU 5000A does not support LSD2. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address13AH and 13BH [1] Addresses (hexadecimal values) on setting the MBE message (LSD2) mode. The MBE message (LSD2) mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits, or specially by setting any of bit 0, bit 2, or bit 3 in the lower-half 8 bits to “1” or “0”. Accordingly, since the upper- half 8 bits are always 00H , set only the lower-half 8 bits (address 13AH). ADDRESS MBE MESSAGE (LSD2) MODE 13AH Lower-half 8 bits setting address (b0 to b7) 13BH Upper-half 8 bits setting address (b8 to b15) xi: System parameter values See below: [1] System parameter values on setting the MBE message (LSD2) mode for the addresses 13AH and 13BH. The factory shipment value for the system parameter is 00H 00H .
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-049 MCU 5000A Multipoint Control Unit MBE MESSAGE (LSD2) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER MBE MESSAGE (LSD2) MODE SETTING ADDRESS 13BHADDRESS 13AH 00H 00H OFF 00H 01H 1200 b/s is ON. 00H 04H 4800 b/s is ON. 00H 08H 9600 b/s is ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-050 MBE MESSAGE (VIDEO) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set expansion video devices to be used in communication with the connecting CODECs (VL 5000s). STEP PROCEDURE Note: Set “PTY ” and “FULL ” to OFF as a general rule. Set “VSP ” to ON when the dual screen multiplex function is used at the connecting terminals, and OFF when it is not used. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address13CH and 13DH [1] Addresses (hexadecimal values) on setting the MBE message (video) mode. The MBE message (video) mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits, or specifically by setting any of bit 1 through bit 3 in the lower-half 8 bits to “1” or “0”. Accordingly, since the upper- half 8 bits are always “00H”, set only the lower-half 8 bits (address 13CH). ADDRESS MBE MESSAGE (VIDEO) MODE 13CH Lower-half 8 bits setting address (b0 to b7) 13DH Upper-half 8 bits setting address (b8 to b15)
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-050 MCU 5000A Multipoint Control Unit MBE MESSAGE (VIDEO) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the MBE message (video) mode for the address 13CH and 13DH. The factory shipment value for the system parameter is 06H 00H . SYSTEM PARAMETER MBE MESSAGE (VIDEO) MODE SETTING ADDRESS 13DHADDRESS 13CH 00H 00H OFF 00H 01H PTY is ON. 00H 02H FULL is ON. 00H 03H PTY and FULL are ON. 00H 04H VSP is ON. 00H 05H PTY and VSP are ON. 00H 06H FULL and VSP are ON. 00H 07H PTY, FULL and VSP are ON. Note: PTY detects a parity error and performs Demand Refresh on its occurrence. FULL: NTSC full resolution mode VSP: dual screen multiplex mode 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-101 AUDIO CAPABILITY TERMINAL CAPABILITY RELATED RCON (H.243 mode) Group A and Group B:A: means Group A and B: means Group B. Audio Capability (A: +200H ~ +203H) (B: +260H ~ +263H) b7 b6b5 b4 b3 b2 b1 b0 b1 : m -Law, OF (F6)Default = 0AH A: +200H 0 fixed 0 fixed 0 fixed 0 fixed 1 010 fixed b6 : G.722-64k b7 : G.722-48k B: +260H b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +201H B: +261H b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +202H B: +262H b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +203H B: +263H
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-101 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-102 TRANSFER RATE CAPABILITY TERMINAL CAPABILITY RELATED Transfer Rate Capability (A: +204H ~ 207H) (B: +264H ~ +267H) b7 b6b5 b4 b3 b2 b1 b0 b0 : 64 kbps (T1/RS422/INF-H0) b1 : 64 x 2 kbps (T1/RS422/INS-H0)Default = C2 11 0 fixed0 fixed 0 fixed0 fixed 1 0 b6 : 128 kbps (T1/RS422) b7 : 192 kbps (T1/RS422) A: +204H B: +264H b7 b6b5 b4 b3 b2 b1 b0 Default = C5H 11 0 fixed0 fixed 0 fixed1 0 1 A: +205H B: +265H b0 : 256 kbps (T1/RS422) b1 : 384 kbps (T1/RS422/INS-H0) b2 : 384 x 2 kbps (T1/RS422/INF-H0) b6 : 512 kbps (T1/RS422) b7 : 768 kbps (T1/RS422) b7 b6b5 b4 b3 b2 b1 b0 b0 : 1152 kbps (T1/RS422) b1 : 1472 kbps (T1)Default = 0FH 11 1 1 b2 : 1536 kbps (T1/RS422) b3 : 1920 kbps (RS422) A: +206H B: +266H b7 b6b5 b4 b3 b2 b1 b0 Default = 00H A: +207H B: +267H
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-102 MCU 5000A Multipoint Control Unit This page is for your notes.