    							NECA 34 0-4 14- 500 Revision 2.0   Page 13 of 14
    MCU  5000A Multipoint Control  U nit   INT-001
    9.  HANDLING OF BACKUP MEMORY B ATTE RY IN M CONT UNIT
    A
    +?
    CN 2
    C7C8
    ON
    As seen for A
    OPER ATING CONDITION  24-H OUR DISCHARGE  8 HOUR/E AC H TIME DISCHARGE 
    						
    							Page 14 of 14   NECA 3 40-4 14- 500 Re vis ion 2.0
    INT-001   MCU 5000A Mult ipoint Con trol Unit
    D . Re placement of  
    						
    							NECA 340-414-500 Revision 2.0 Page 1 of 4
    MCU 5000A Multipoint Control Unit TCP-001
    CHECK ON POWER SYSTEM
    GENERAL: 
    Check on  AC power supply and output voltages of PWR Unit is 
    conducted.
    APPARATUS:
    Digital Multimeter (DDM)
    STEP PROCEDURE REFERENCE NO.
    1 Turn ON the power switch of the MCU 5000A.
    2 Is POWER LED of PWR Unit lit?
    If YES
    , go to Step 10
    .
    If NO
    , go to Step 3
    . 
    3 Set Digital Multimeter (DDM) range  to measure 300 VAC.
    4 Turn DDM power switch to ON.
    5 Connect DDM test cord between DDM and power terminal of plug of power 
    cord.  (See Fig. 1)
    6 Read DDM measurement.
    7 Does AC line voltage meet specified figure of 85 VAC through 132 VAC?
    If YES
    , go to Step 10
    .
    If NO
    , go to Step 8
    .
    8 Is power cord normal?
    If YES
    , go to Step 10
    .
    If NO
    , go to Step 9
    .
    9 Replace the power cord, then go to Step 6
    .
    10 Check DC output voltage of PWR unit.
    11 Set the range of the Digital Multimeter (DDM) to measure 20 VDC.
    12 CAUTION: BE CAREFUL OF THE POLARITY OF THE VOLTAGE 
    CHECK TERMINALS.
    Connect one end of the test cord to the DDM and other end to the power 
    terminal of PWR unit. (See Fig.2)
    13 Confirm that the measured output power voltage is between +4.75 VDC and 
    +5.25 VDC. 
    						
    							Page 2 of 4 NECA 340-414-500 Revision 2.0
    TCP-001 MCU 5000A Multipoint Control Unit
    CHECK ON POWER SYSTEM
    Figure 1:   Checking AC Line Voltage
    STEP PROCEDURE REFERENCE NO.
    14 Does output voltage meet specified figure of +4.75 V through + 5.25 VDC?
    If YES, go to 
    Step 15.
    If 
    NO, go to 
    Step 18.
    15
    CAUTION:  
    BE CAREFUL OF THE POLARITY OF THE VOLTAGE 
    CHECK TERMINAL.
    Connect one end of the test cord to the DDM and other end to the power 
    terminal of PWR unit. (See Fig. 2)
    16 Confirm that the measured output power voltage is between +11.4 VDC and 
    +12.6 VDC.
    17 Does output voltage meet specified figure of +11.4VDC  to +12.6 VDC?
    If 
    YES, go to 
    Step 19.
    If 
    NO, go to 
    Step 18.
    18 Replace the PWR unit.
    19 End of procedure.
    POWER TERMINAL
    19 990 
    						
    							NECA 340-414-500 Revision 2.0 Page 3 of 4
    MCU 5000A Multipoint Control Unit TCP-001
    CHECK ON POWER SYSTEM
    Figure 2:   Checking DC Output Voltage of PWR Unit
    MON
    CONF
    B A
    LMT    MON
    OFFON
       MEM
    MCU 5000A
    PWR
    19 990
    +12VDC
    +5 VDC
    G
    -12 VDC 
    						
    							Page 4 of 4 NECA 340-414-500 Revision 2.0
    TCP-001 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-002
    IMPLEMENTATION OF C&I LOOPBACK FUNCTION
    GENERAL: 
    Operate a C&I remote loopback on specified terminals of VL 5000 using RLCS
     
    command referring to NECA 340-414-300
    .
    APPARATUS: 
    MCU console
    STEP PROCEDURE REFERENCE NO.
    1 Has the MCU console been started up?
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 2
    .TCP-016
    2 Start up the MCU console and put it into communication state.TCP-016
    3 Decide the number  (1 to 8) of conference room where the loop point is to be 
    set and the kind of loop by using RLCS
     command.
     (video signal loop=V, digital signal loop=D, audio signal loop=A)COP-177
    4Enter the RLCS
     command and above parameters of Step 3
     and press the 
    RETURN 
    key.
    COP-177
    5 Verify that the normal response is displayed with OK
    .
    If YES
    , go to Step 6
    .
    If NO
    , repeat Step 4
     using error code.
    6 After executing the loopback, be sure to release the loop using the RLCS
     
    command.
    Input:  RLCS
     parameter (number of the conference room where the loop point 
    is set.)
    Loop releasing parameter=0 
    ¿
    COP-177
    7
    End of procedure 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-002 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-003
      SETTING OF MCU 5000A LOOPBACK POINTS
    GENERAL: 
    Set MCU loopback on specified point of MCU 5000A using STLP
     
    command, referring to NECA 340-414-300
    .
    APPARATUS: 
    MCU console
    STEP PROCEDURE REFERENCE NO.
    1 Has the MCU console been started up?
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 2
    .
    2 Start the MCU console up and put it into communication state.TCP-016
    3 Decide test loopback points A to H shown in Fig.1.
    4 Enter the STLP
     command and necessary parameters for loop setting and press 
    RETURN
     key.COP-178
    5 Verify that the normal response is displayed with OK
    .
    If YES
    , go to Step 6
    .
    If NO
    , repeat Step 4
     using error code.COP-180
    6 After the end of loop test (See TCP-004), be sure to release the loop using the 
    RTLP
     command.
    7 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-003 MCU 5000A Multipoint Control Unit
    Figure 1:   MCU 5000A Loopback Point
    RELAY IPAF MTSC
    MTSC MTSCMTSC
    PN
    CHECKER
    PN
    GENERATOR
    POINT A
    POINT B
    POINT C POINT D POINT E
    POINT F1.5M LIF UNIT EC H221 MUX UNIT
    V SW/LSD UNIT
    HSCX
    A CODEC POINT H POINT G
    RELAY MTSC
    MTSC MTSCMTSC
    PN
    CHECKER
    PN
    GENERATOR
    POINT A
    POINT B
    POINT C POINT D POINT FRS-422 LIF UNIT EC H221 MUX UNIT
    V SW/LSD UNIT
    HSCX
    A CODEC POINT H POINT G
    (a)  In case that MCU 5000A consists of 1.5M LIF unit and H0-INF unit
    (b) In case that MCU 5000A consists of  RS-422 LIF unit 
    						