    							NECA 340-414-210 Revision 2.0Page i
    MCU 5000A Multipoint Control Unit Table of Contents
    Table of Contents
    INTRODUCTION .................................................................................................  INT-001
    MOUNT MCU 5000A TO 19-INCH RACK...........................................................  INP-001
    REMOVE MCU 5000A FROM 19-INCH RACK...................................................  INP-002
    OPEN/REMOVE FRONT COVER .......................................................................  INP-003
    INSTALL/CLOSE FRONT COVER .....................................................................  INP-004
    TURN ON/OFF POWER SWITCH.......................................................................  INP-005
    MOUNT UNIT TO SHELF....................................................................................  INP-006
    REMOVE UNIT FROM SHELF............................................................................  INP-007
    INTERNAL CONNECTION..................................................................................  INP-008
    LIF (CH1 to CH16) CABLE CONNECTION ........................................................  INP-009
    POWER CORD CONNECTION...........................................................................  INP-011
    START-UP OF MCU CONSOLE .........................................................................  INP-012
    SETTING FOR CODEC .......................................................................................  INP-013
    1.5M LIF UNIT ...................................................................................................  GSD-001
    RS-422 LIF UNIT ...............................................................................................  GSD-002
    H0-INF  UNIT .....................................................................................................  GSD-003
    EC H221 MUX UNIT ..........................................................................................  GSD-004
    V SW/LSD IF UNIT ............................................................................................  GSD-005
    A CODEC UNIT .................................................................................................  GSD-006
    A SUM UNIT ......................................................................................................  GSD-007
    PG/SIO UNIT .....................................................................................................  GSD-008
    M CONT UNIT ...................................................................................................  GSD-009
    VDSW UNIT .......................................................................................................  GSD-010 
    						
    							Page NECA 340-414-210 Revision 2.0
    Table of Contents MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-210 Revision 2.0 Page 1 of 14
    MCU 5000A Multipoint Control Unit INT-001
    INTRODUCTION
    1:  GENERAL
    A: Introduction 1.01
    This practice provides installation and turn-up of Multipoint Control Unit 
    5000A (MCU 5000A).
    1.02
    This equipment appearance is shown Fig. 1-1.  The equipment is installed 
    in 19-inch wide racks, and is installed from the front of the rack.  
    Figure 1-1:   External Views of MCU 5000A
    MULTIPOINT CONTROL UNIT
    TOP VIEWREAR VIEW
    FRONT VIEWSIDE VIEW
    14 in
    15.7 in (39.88 cm)19 in (48.26 cm)
    NEC
    MCU
    (35.56 cm) 
    						
    							Page 2 of 14 NECA 340-414-210 Revision 2.0
    INT-001 MCU 5000A Multipoint Control Unit
    B: Scope of 
    Installation1.03
    Fig. 1-2 shows the system configuration of MCU 5000A with MCU 
    console.  This manual is only described about the scope of the installation for 
    MCU 5000A.
    Figure 1-2:   System Configuration With MCU Console
    MCU CONSOLEMCU CONSOLE MODEM
    MODEM VL5000
    VL5000 MUX MUXMUXVIDEO
    VIDEOAU D I O
    AUDIORS-232C
    RS-232C
    REVERSE
    AMI (B8ZS)
    OR
    RS-422
    DIGITAL LINES
    RS-232C
    CONFERENCE ROOM A
    CONFERENCE ROOM B
    MAX. 8 Conference Rooms can be Connected MCU 5000A 
    						
    							NECA 340-414-210 Revision 2.0 Page 3 of 14
    MCU 5000A Multipoint Control Unit INT-001
    C: Installation 
    Procedure 1.04
    Fig. 1-3 shows an installation procedure to assure a smooth installation 
    for MCU 5000A.
    Figure 1-3:   Installation Procedure for MCU 5000A
    1
    2
    3
    4
    5
    6
    7
    9
    10
    11
    8
    PREPARATION TOOLS
    DELIVERY
    DELIVERY
    UNPACKING
    INVENTORY CHECK
    MOUNTING
    CABLE WIRING
    CABLE CONNECTION
    CONNECTION
    SW ON
    TURN UP TEST
    SYSTEM TEST POWER
    SUPPLY
    LEGEND:
    CUSTOMER OR SUPPLIER
    (INSTALLATION)
    CUSTOMER OR SUPPLIER
    (ENGINEERING OR MAINTENANCE)
    CUSTOMERINSTALLATION JOB
    SET-UP 
    						
    							Page 4 of 14 NECA 340-414-210 Revision 2.0
    INT-001 MCU 5000A Multipoint Control Unit
    2:  PREPARATION
    A: Pre-installation 2.01Before starting MCU 5000A installation, consult with user and clarify the 
    scope of work to prepare beforehand various works for the purpose of doing the  
    work smoothly.  Table 2-1 shows the items according to the installation procedure.
    Table 2-1: Scope of Work for MCU
    WORK 
    ITEMSSUPPLIER CUSTOMER
    Confirmation of the location for MCU 5000A and related equipment
    Preparation for power supply
    Checking cables, other installation materials
    Arrangement and preparation of tools
    Protection of other equipment from being harmed by the installation process
    Equipment unpacking
    Equipment installation
    Cable wiring
    Switching ON
    Turn-up test
    System test 
    						
    							NECA 340-414-210 Revision 2.0 Page 5 of 14
    MCU 5000A Multipoint Control Unit INT-001
    B: Unpacking 2.02
    Preparation for unpacking: Before unpacking, the following should be 
    prepared first.
    • Invoice, packing lists, and other required documents
    • Tools required for unpacking (scissors, cutter, cotton gloves, etc.)
    • Personnel necessary for unpacking
    2.03
    Unpacking: Remove materials which are used to protect equipment 
    during shipment.  The procedures are as follows: Fig. 2-1 shows unpacking 
    sketches.
    • Remove the packing mat.
    • Open the cardboard box and take MCU 5000A with protector out of the 
    box.
    • Remove side pads and rear pad.
    • Remove polyethylene sheet and desiccant (packet of drying material).
    C: Inventory Check 2.04
    After unpacking, carry MCU 5000A to the installation site.  And check 
    the names and quantities of the received equipment and accessories with packing 
    list.  The procedure is as follows:
    Step
    Procedure
    1 Prepare the packing lists which are annexed to the equipment.
    2 Verify names and quantities of equipment and accessories 
    while referring to the packing list.
    3 Record the date, the name of the person in charge and the 
    result of inventory in blanks on the packing list.
    2.05
    If any problems including omission, shortage, or breakage are found as a 
    result of comparison with the packing list, inform dealer, delivery carrier, or NEC 
    Sales Office immediately. 
    						
    							Page 6 of 14 NECA 340-414-210 Revision 2.0
    INT-001 MCU 5000A Multipoint Control Unit
    Figure 2-1:   Unpacking Procedure
    4
    3
    5
    3
    6
    2
    1
    NO. ITEM NO. ITEM
    1Mat 4Read Pad
    2 Cardboard 5 Polyethylene sheet
    3 Side pad 6 Desiccant 
    						
    							NECA 340-4 14- 21 0  Revisio n 2.0   Page  7  of  14
    MCU  5000A Multipoint Control  U nit   INT-001
    3:  INSTALL ATION 
    						
    							Page 8 of 14 NECA 340-414-210 Revision 2.0
    INT-001 MCU 5000A Multipoint Control Unit
    Figure 3-1:   Unit Layout of MCU 5000A
    C: Unit Mounting and 
    Removing3.03
    Unit are made from printed wiring board of plug-in type, and MCU 
    5000A is composed these units.  Refer to the procedure for mounting and 
    removing the units  (INP-006
     and INP-007
    ).
    L
    I
    F
    #
    1L
    I
    F
    #
    2L
    I
    F
    #
    3L
    I
    F
    #
    4E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    1E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    2E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    3E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    4E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    5E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    6E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    7E
    C
    H
    2
    2
    1
    M
    U
    X
    #
    8V
    S
    W
    /
    L
    S
    DH
    S
    D
    I
    F
    #
    1H
    S
    D
    I
    F
    #
    2A
    C
    O
    D
    E
    C
    #
    1A
    C
    O
    D
    E
    C
    #
    2A
    S
    U
    MP
    G
    /
    S
    I
    OM
    C
    O
    N
    TPWR
    CABLE SPACE
    01 23 45 6 7
    8
    024 6810121416182022
    24 2628 (U) 1U = 1.75
    (B)
    1B = 0.59 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Mcu 5000a Multipoint Control Unit Equipment Manual