NECA 340-414-220 Revision 2.0 Page 11 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 5007H Lines 1,2,3,13&15 are masked 802FH Lines 1,2,3,4,6&16 are masked 9007H Lines 1,2,3,13&16 are masked 00CFH Lines 1,2,3,4,7&8 are masked 6007H Lines 1,2,3,14&15 are masked 014FH Lines 1,2,3,4,7&9 are masked A007H Lines 1,2,3,14&16 are masked 024FH Lines 1,2,3,4,7&10 are masked C007H Lines 1,2,3,15&16 are masked 044FH Lines 1,2,3,4,7&11 are masked 003FH Lines 1,2,3,4,5&6 are masked 084FH Lines 1,2,3,4,7&12 are masked 005FH Lines 1,2,3,4,5&7 are masked 104FH Lines 1,2,3,4,7&13 are masked 009FH Lines 1,2,3,4,5&8 are masked 204FH Lines 1,2,3,4,7&14 are masked 011FH Lines 1,2,3,4,5&9 are masked 404FH Lines 1,2,3,4,7&15 are masked 021FH Lines 1,2,3,4,5&10 are masked 804FH Lines 1,2,3,4,7&16 are masked 041FH Lines 1,2,3,4,5&11 are masked 018FH Lines 1,2,3,4,8&9 are masked 081FH Lines 1,2,3,4,5&12 are masked 028FH Lines 1,2,3,4,8&10 are masked 101FH Lines 1,2,3,4,5&13 are masked 048FH Lines 1,2,3,4,8&11 are masked 201FH Lines 1,2,3,4,5&14 are masked 088FH Lines 1,2,3,4,8&12 are masked 401FH Lines 1,2,3,4,5&15 are masked 108FH Lines 1,2,3,4,8&13 are masked 801FH Lines 1,2,3,4,5&16 are masked 208FH Lines 1,2,3,4,8&14 are masked 006FH Lines 1,2,3,4,6&7 are masked 408FH Lines 1,2,3,4,8&15 are masked 00AFH Lines 1,2,3,4,6&8 are masked 808FH Lines 1,2,3,4,8&16 are masked 012FH Lines 1,2,3,4,6&9 are masked 030FH Lines 1,2,3,4,9&10 are masked 022FH Lines 1,2,3,4,6&10 are masked 050FH Lines 1,2,3,4,9&11 are masked 042FH Lines 1,2,3,4,6&11 are masked 090FH Lines 1,2,3,4,9&12 are masked 082FH Lines 1,2,3,4,6&12 are masked 110FH Lines 1,2,3,4,9&13 are masked 102FH Lines 1,2,3,4,6&13 are masked 210FH Lines 1,2,3,4,9&14 are masked 202FH Lines 1,2,3,4,6&14 are masked 410FH Lines 1,2,3,4,9&15 are masked 402FH Lines 1,2,3,4,6&15 are masked 810FH Lines 1,2,3,4,9&16 are masked
Page 12 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 060FH Lines 1,2,3,4,10&11 are masked 043FH Lines 1,2,3,4,5,6&11 are masked 0A0FH Lines 1,2,3,4,10&12 are masked 083FH Lines 1,2,3,4,5,6&12 are masked 120FH Lines 1,2,3,4,10&13 are masked 103FH Lines 1,2,3,4,5,6&13 are masked 220FH Lines 1,2,3,4,10&14 are masked 203FH Lines 1,2,3,4,5,6&14 are masked 420FH Lines 1,2,3,4,10&15 are masked 403FH Lines 1,2,3,4,5,6&15 are masked 820FH Lines 1,2,3,4,10&16 are masked 803FH Lines 1,2,3,4,5,6&16 are masked 0C0FH Lines 1,2,3,4,11&12 are masked 00DFH Lines 1,2,3,4,5,7&8 are masked 140FH Lines 1,2,3,4,11&13 are masked 015FH Lines 1,2,3,4,5,7&9 are masked 240FH Lines 1,2,3,4,11&14 are masked 025FH Lines 1,2,3,4,5,7&10 are masked 440FH Lines 1,2,3,4,11&15 are masked 045FH Lines 1,2,3,4,5,7&11 are masked 840FH Lines 1,2,3,4,11&16 are masked 085FH Lines 1,2,3,4,5,7&12 are masked 180FH Lines 1,2,3,4,12&13 are masked 105FH Lines 1,2,3,4,5,7&13 are masked 280FH Lines 1,2,3,4,12&14 are masked 205FH Lines 1,2,3,4,5,7&14 are masked 480FH Lines 1,2,3,4,12&15 are masked 405FH Lines 1,2,3,4,5,7&15 are masked 880FH Lines 1,2,3,4,12&16 are masked 805FH Lines 1,2,3,4,5,7&16 are masked 300FH Lines 1,2,3,4,13&14 are masked 019FH Lines 1,2,3,4,5,8&9 are masked 500FH Lines 1,2,3,4,13&15 are masked 029FH Lines 1,2,3,4,5,8&10 are masked 900FH Lines 1,2,3,4,13&16 are masked 049FH Lines 1,2,3,4,5,8&11 are masked 600FH Lines 1,2,3,4,14&15 are masked 089FH Lines 1,2,3,4,5,8&12 are masked A00FH Lines 1,2,3,4,14&16 are masked 109FH Lines 1,2,3,4,5,8&13 are masked C00FH Lines 1,2,3,4,15&16 are masked 209FH Lines 1,2,3,4,5,8&14 are masked 007FH Lines 1,2,3,4,5,6&7 are masked 409FH Lines 1,2,3,4,5,8&15 are masked 00BFH Lines 1,2,3,4,5,6&8 are masked 809FH Lines 1,2,3,4,5,8&16 are masked 013FH Lines 1,2,3,4,5,6&9 are masked 031FH Lines 1,2,3,4,5,9&10 are masked 023FH Lines 1,2,3,4,5,6&10 are masked 051FH Lines 1,2,3,4,5,9&11 are masked
NECA 340-414-220 Revision 2.0 Page 13 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 091FH Lines 1,2,3,4,5,9&12 are masked C01FH Lines 1,2,3,4,5,15&16 are masked 111FH Lines 1,2,3,4,5,9&13 are masked 00FFH Lines 1,2,3,4,5,6,7&8 are masked 211FH Lines 1,2,3,4,5,9&14 are masked 017FH Lines 1,2,3,4,5,6,7&9 are masked 411FH Lines 1,2,3,4,5,9&15 are masked 027FH Lines 1,2,3,4,5,6,7&10 are masked 811FH Lines 1,2,3,4,5,9&16 are masked 047FH Lines 1,2,3,4,5,6,7&11 are masked 061FH Lines 1,2,3,4,5,10&11 are masked 087FH Lines 1,2,3,4,5,6,7&12 are masked 0A1FH Lines 1,2,3,4,5,10&12 are masked 107FH Lines 1,2,3,4,5,6,7&13 are masked 121FH Lines 1,2,3,4,5,10&13 are masked 207FH Lines 1,2,3,4,5,6,7&14 are masked 221FH Lines 1,2,3,4,5,10&14 are masked 407FH Lines 1,2,3,4,5,6,7&15 are masked 421FH Lines 1,2,3,4,5,10&15 are masked 807FH Lines 1,2,3,4,5,6,7&16 are masked 821FH Lines 1,2,3,4,5,10&16 are masked 01BFH Lines 1,2,3,4,5,6,8&9 are masked 0C1FH Lines 1,2,3,4,5,11&12 are masked 02BFH Lines 1,2,3,4,5,6,8&10 are masked 141FH Lines 1,2,3,4,5,11&13 are masked 04BFH Lines 1,2,3,4,5,6,8&11 are masked 241FH Lines 1,2,3,4,5,11&14 are masked 08BFH Lines 1,2,3,4,5,6,8&12 are masked 441FH Lines 1,2,3,4,5,11&15 are masked 10BFH Lines 1,2,3,4,5,6,8&13 are masked 841FH Lines 1,2,3,4,5,11&16 are masked 20BFH Lines 1,2,3,4,5,6,8&14 are masked 181FH Lines 1,2,3,4,5,12&13 are masked 40BFH Lines 1,2,3,4,5,6,8&15 are masked 281FH Lines 1,2,3,4,5,12&14 are masked 80BFH Lines 1,2,3,4,5,6,8&16 are masked 481FH Lines 1,2,3,4,5,12&15 are masked 033FH Lines 1,2,3,4,5,6,9&10 are masked 881FH Lines 1,2,3,4,5,12&16 are masked 053FH Lines 1,2,3,4,5,6,9&11 are masked 301FH Lines 1,2,3,4,5,13&14 are masked 093FH Lines 1,2,3,4,5,6,9&12 are masked 501FH Lines 1,2,3,4,5,13&15 are masked 113FH Lines 1,2,3,4,5,6,9&13 are masked 901FH Lines 1,2,3,4,5,13&16 are masked 213FH Lines 1,2,3,4,5,6,9&14 are masked 601FH Lines 1,2,3,4,5,14&15 are masked 413FH Lines 1,2,3,4,5,6,9&15 are masked A01FH Lines 1,2,3,4,5,14&16 are masked 813FH Lines 1,2,3,4,5,6,9&16 are masked
Page 14 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 063FH Lines 1,2,3,4,5,6,10&11 are masked 10FFH Lines 1,2,3,4,5,6,7,8&13 are masked 0A3FH Lines 1,2,3,4,5,6,10&12 are masked 20FFH Lines 1,2,3,4,5,6,7,8&14 are masked 123FH Lines 1,2,3,4,5,6,10&13 are masked 40FFH Lines 1,2,3,4,5,6,7,8&15 are masked 223FH Lines 1,2,3,4,5,6,10&14 are masked 80FFH Lines 1,2,3,4,5,6,7,8&16 are masked 423FH Lines 1,2,3,4,5,6,10&15 are masked 037FH Lines 1,2,3,4,5,6,7,9&10 are masked 823FH Lines 1,2,3,4,5,6,10&16 are masked 057FH Lines 1,2,3,4,5,6,7,9&11 are masked 0C3FH Lines 1,2,3,4,5,6,11&12 are masked 097FH Lines 1,2,3,4,5,6,7,9&12 are masked 143FH Lines 1,2,3,4,5,6,11&13 are masked 117FH Lines 1,2,3,4,5,6,7,9&13 are masked 243FH Lines 1,2,3,4,5,6,11&14 are masked 067FH Lines 1,2,3,4,5,6,7,10&11 are masked 443FH Lines 1,2,3,4,5,6,11&15 are masked 0A7FH Lines 1,2,3,4,5,6,7,10&12 are masked 843FH Lines 1,2,3,4,5,6,11&16 are masked 127FH Lines 1,2,3,4,5,6,7,10&13 are masked 183FH Lines 1,2,3,4,5,6,12&13 are masked 227FH Lines 1,2,3,4,5,6,7,10&14 are masked 283FH Lines 1,2,3,4,5,6,12&14 are masked 427FH Lines 1,2,3,4,5,6,7,10&15 are masked 483FH Lines 1,2,3,4,5,6,12&15 are masked 827FH Lines 1,2,3,4,5,6,7,10&16 are masked 883FH Lines 1,2,3,4,5,6,12&16 are masked 0C7FH Lines 1,2,3,4,5,6,7,11&12 are masked 303FH Lines 1,2,3,4,5,6,13&14 are masked 147FH Lines 1,2,3,4,5,6,7,11&13 are masked 503FH Lines 1,2,3,4,5,6,13&15 are masked 247FH Lines 1,2,3,4,5,6,7,11&14 are masked 903FH Lines 1,2,3,4,5,6,13&16 are masked 447FH Lines 1,2,3,4,5,6,7,11&15 are masked 603FH Lines 1,2,3,4,5,6,14&15 are masked 847FH Lines 1,2,3,4,5,6,7,11&16 are masked
NECA 340-414-220 Revision 2.0 Page 15 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 187FH Lines 1,2,3,4,5,6,7,12&13 are masked 81FFH Lines 1,2,3,4,5,6,7,8,9&16 are masked 287FH Lines 1,2,3,4,5,6,7,12&14 are masked 06FFH Lines 1,2,3,4,5,6,7,8,10&11 are masked 487FH Lines 1,2,3,4,5,6,7,12&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,10&12 are masked 887FH Lines 1,2,3,4,5,6,7,12&16 are masked 12FFH Lines 1,2,3,4,5,6,7,8,10&13 are masked 307FH Lines 1,2,3,4,5,6,7,13&14 are masked 22FFH Lines 1,2,3,4,5,6,7,8,10&14 are masked 507FH Lines 1,2,3,4,5,6,7,13&15 are masked 42FFH Lines 1,2,3,4,5,6,7,8,10&15 are masked 907FH Lines 1,2,3,4,5,6,7,13&16 are masked 82FFH Lines 1,2,3,4,5,6,7,8,10&16 are masked 607FH Lines 1,2,3,4,5,6,7,14&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,11&12 are masked A07FH Lines 1,2,3,4,5,6,7,14&16 are masked 14FFH Lines 1,2,3,4,5,6,7,8,11&13 are masked C07FH Lines 1,2,3,4,5,6,7,15&16 are masked 24FFH Lines 1,2,3,4,5,6,7,8,11&14 are masked 03FFH Lines 1,2,3,4,5,6,7,8,9&10 are masked 44FFH Lines 1,2,3,4,5,6,7,8,11&15 are masked 05FFH Lines 1,2,3,4,5,6,7,8,9&11 are masked 84FFH Lines 1,2,3,4,5,6,7,8,11&16 are masked 09FFH Lines 1,2,3,4,5,6,7,8,9&12 are masked 18FFH Lines 1,2,3,4,5,6,7,8,12&13 are masked 11FFH Lines 1,2,3,4,5,6,7,8,9&13 are masked 28FFH Lines 1,2,3,4,5,6,7,8,12&14 are masked 21FFH Lines 1,2,3,4,5,6,7,8,9&14 are masked 48FFH Lines 1,2,3,4,5,6,7,8,12&15 are masked 41FFH Lines 1,2,3,4,5,6,7,8,9&15 are masked 88FFH Lines 1,2,3,4,5,6,7,8,12&16 are masked
Page 16 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETE RLINE NUMBER TO BE MASKEDSYSTEM PARAMETE RLINE NUMBER TO BE MASKED 30FFH Lines 1,2,3,4,5,6,7,8,13&14 are masked 85FFH Lines 1,2,3,4,5,6,7,8,9,11&16 are masked 50FFH Lines 1,2,3,4,5,6,7,8,13&15 are masked 19FFH Lines 1,2,3,4,5,6,7,8,9,12&13 are masked 90FFH Lines 1,2,3,4,5,6,7,8,13&16 are masked 29FFH Lines 1,2,3,4,5,6,7,8,9,12&14 are masked 60FFH Lines 1,2,3,4,5,6,7,8,14&15 are masked 49FFH Lines 1,2,3,4,5,6,7,8,9,12&15 are masked A0FFH Lines 1,2,3,4,5,6,7,8,14&16 are masked 89FFH Lines 1,2,3,4,5,6,7,8,9,12&16 are masked C0FFH Lines 1,2,3,4,5,6,7,8,15&16 are masked 31FFH Lines 1,2,3,4,5,6,7,8,9,13&14 are masked 07FFH Lines 1,2,3,4,5,6,7,8,9,10&11 are masked 51FFH Lines 1,2,3,4,5,6,7,8,9,13&15 are masked 0BFFH Lines 1,2,3,4,5,6,7,8,9,10&12 are masked 91FFH Lines 1,2,3,4,5,6,7,8,9,13&16 are masked 13FFH Lines 1,2,3,4,5,6,7,8,9,10&13 are masked 61FFH Lines 1,2,3,4,5,6,7,8,9,14&15 are masked 23FFH Lines 1,2,3,4,5,6,7,8,9,10&14 are masked A1FFH Lines 1,2,3,4,5,6,7,8,9,14&16 are masked 43FFH Lines 1,2,3,4,5,6,7,8,9,10&15 are masked C1FFH Lines 1,2,3,4,5,6,7,8,9,15&16 are masked 83FFH Lines 1,2,3,4,5,6,7,8,9,10&16 are masked0FFFH Lines 1,2,3,4,5,6,7,8,9,10,11&12 are masked 0DFFH Lines 1,2,3,4,5,6,7,8,9,11&12 are masked17FFH Lines 1,2,3,4,5,6,7,8,9,10,11&13 are masked 15FFH Lines 1,2,3,4,5,6,7,8,9,11&13 are masked27FFH Lines 1,2,3,4,5,6,7,8,9,10,11&14 are masked 25FFH Lines 1,2,3,4,5,6,7,8,9,11&14 are masked47FFH Lines 1,2,3,4,5,6,7,8,9,10,11&15 are masked 45FFH Lines 1,2,3,4,5,6,7,8,9,11&15 are masked87FFH Lines 1,2,3,4,5,6,7,8,9,10,11&16 are masked
NECA 340-414-220 Revision 2.0 Page 17 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 1BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are masked 2BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are masked 4BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&15 are masked 8BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&16 are maskedA7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&16 are masked 33FFH Lines 1,2,3,4,5,6,7,8,9,10,13&14 are maskedC7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,15&16 are masked 53FFH Lines 1,2,3,4,5,6,7,8,9,10,13&15 are masked3FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&14 are masked 93FFH Lines 1,2,3,4,5,6,7,8,9,10,13&16 are masked5FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&15 are masked 63FFH Lines 1,2,3,4,5,6,7,8,9,10,14&15 are masked9FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&16 are masked A3FFH Lines 1,2,3,4,5,6,7,8,9,10,14&16 are masked6FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&15 are masked C3FFH Lines 1,2,3,4,5,6,7,8,9,10,15&16 are maskedAFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&16 are masked 1FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&13 are maskedCFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 15&16 are masked 2FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&14 are masked7FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13, 14&15 are masked 4FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&15 are maskedBFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 14&16 are masked 8FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&16 are maskedDFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 15&16 are masked 37FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&14 are maskedFFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 14,15&16 are masked
Page 18 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-012 1.5M LIF LINE EQUALIZER SETTING LINE RELATED SUMMARY: Set the physical properties of line. STEP PROCEDURE Note: When connecting to a T1 line, set the equalizer value according to the cable distance. In the case of an NTT line, however, fix the value to “EQL-A” before use. The line equalizer can be set independently for each line. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address40H to 4FH [1] Line numbers corresponding to the addresses (hexadecimal values) on setting the line equalizer. ADDRESS PHYSICAL LINE NUMBERADDRESS PHYSICAL LINE NUMBER 40H 1 48H 9 41H 2 49H 10 42H 3 4AH 11 43H 4 4BH 12 44H 5 4CH 13 45H 6 4DH 14 46H 7 4EH 15 47H 8 4FH 16
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-012 MCU 5000A Multipoint Control Unit 1.5M LIF LINE EQUALIZER SETTING LINE RELATED STEP PROCEDURE xi:System parameter values See below: [2] System parameter values on setting the line equalizer for the addresses 40H to 4FH. The factory shipment value for the system parameter applicable to all the lines is 00H. SYSTEM PARAMETER LINE EQUALIZER 00H EQL-A (0 to 133 feet) 01H EQL-B (133 to 267 feet) 02H EQL-C (267 to 400 feet) 03H EQL-D (400 to 533 feet) 04H EQL-E (533 to 655 feet) 2Verify that the normal response is displayed with “ OK”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.