    							NECA 340-414-220 Revision 2.0 Page 11 of 18
    MCU 5000A Multipoint Control Unit SPR-011
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    5007H Lines 1,2,3,13&15 are masked 802FH Lines 1,2,3,4,6&16 are masked
    9007H Lines 1,2,3,13&16 are masked 00CFH Lines 1,2,3,4,7&8 are masked
    6007H Lines 1,2,3,14&15 are masked 014FH Lines 1,2,3,4,7&9 are masked
    A007H Lines 1,2,3,14&16 are masked 024FH Lines 1,2,3,4,7&10 are masked
    C007H Lines 1,2,3,15&16 are masked 044FH Lines 1,2,3,4,7&11 are masked
    003FH Lines 1,2,3,4,5&6 are masked 084FH Lines 1,2,3,4,7&12 are masked
    005FH Lines 1,2,3,4,5&7 are masked 104FH Lines 1,2,3,4,7&13 are masked
    009FH Lines 1,2,3,4,5&8 are masked 204FH Lines 1,2,3,4,7&14 are masked
    011FH Lines 1,2,3,4,5&9 are masked 404FH Lines 1,2,3,4,7&15 are masked
    021FH Lines 1,2,3,4,5&10 are masked 804FH Lines 1,2,3,4,7&16 are masked
    041FH Lines 1,2,3,4,5&11 are masked 018FH Lines 1,2,3,4,8&9 are masked
    081FH Lines 1,2,3,4,5&12 are masked 028FH Lines 1,2,3,4,8&10 are masked
    101FH Lines 1,2,3,4,5&13 are masked 048FH Lines 1,2,3,4,8&11 are masked
    201FH Lines 1,2,3,4,5&14 are masked 088FH Lines 1,2,3,4,8&12 are masked
    401FH Lines 1,2,3,4,5&15 are masked 108FH Lines 1,2,3,4,8&13 are masked
    801FH Lines 1,2,3,4,5&16 are masked 208FH Lines 1,2,3,4,8&14 are masked
    006FH Lines 1,2,3,4,6&7 are masked 408FH Lines 1,2,3,4,8&15 are masked
    00AFH Lines 1,2,3,4,6&8 are masked 808FH Lines 1,2,3,4,8&16 are masked
    012FH Lines 1,2,3,4,6&9 are masked 030FH Lines 1,2,3,4,9&10 are masked
    022FH Lines 1,2,3,4,6&10 are masked 050FH Lines 1,2,3,4,9&11 are masked
    042FH Lines 1,2,3,4,6&11 are masked 090FH Lines 1,2,3,4,9&12 are masked
    082FH Lines 1,2,3,4,6&12 are masked 110FH Lines 1,2,3,4,9&13 are masked
    102FH Lines 1,2,3,4,6&13 are masked 210FH Lines 1,2,3,4,9&14 are masked
    202FH Lines 1,2,3,4,6&14 are masked 410FH Lines 1,2,3,4,9&15 are masked
    402FH Lines 1,2,3,4,6&15 are masked 810FH Lines 1,2,3,4,9&16 are masked 
    						
    							Page 12 of 18 NECA 340-414-220 Revision 2.0
    SPR-011 MCU 5000A Multipoint Control Unit
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    060FH Lines 1,2,3,4,10&11 are masked 043FH Lines 1,2,3,4,5,6&11 are masked
    0A0FH Lines 1,2,3,4,10&12 are masked 083FH Lines 1,2,3,4,5,6&12 are masked
    120FH Lines 1,2,3,4,10&13 are masked 103FH Lines 1,2,3,4,5,6&13 are masked
    220FH Lines 1,2,3,4,10&14 are masked 203FH Lines 1,2,3,4,5,6&14 are masked
    420FH Lines 1,2,3,4,10&15 are masked 403FH Lines 1,2,3,4,5,6&15 are masked
    820FH Lines 1,2,3,4,10&16 are masked 803FH Lines 1,2,3,4,5,6&16 are masked
    0C0FH Lines 1,2,3,4,11&12 are masked 00DFH Lines 1,2,3,4,5,7&8 are masked
    140FH Lines 1,2,3,4,11&13 are masked 015FH Lines 1,2,3,4,5,7&9 are masked
    240FH Lines 1,2,3,4,11&14 are masked 025FH Lines 1,2,3,4,5,7&10 are masked
    440FH Lines 1,2,3,4,11&15 are masked 045FH Lines 1,2,3,4,5,7&11 are masked
    840FH Lines 1,2,3,4,11&16 are masked 085FH Lines 1,2,3,4,5,7&12 are masked
    180FH Lines 1,2,3,4,12&13 are masked 105FH Lines 1,2,3,4,5,7&13 are masked
    280FH Lines 1,2,3,4,12&14 are masked 205FH Lines 1,2,3,4,5,7&14 are masked
    480FH Lines 1,2,3,4,12&15 are masked 405FH Lines 1,2,3,4,5,7&15 are masked
    880FH Lines 1,2,3,4,12&16 are masked 805FH Lines 1,2,3,4,5,7&16 are masked
    300FH Lines 1,2,3,4,13&14 are masked 019FH Lines 1,2,3,4,5,8&9 are masked
    500FH Lines 1,2,3,4,13&15 are masked 029FH Lines 1,2,3,4,5,8&10 are masked
    900FH Lines 1,2,3,4,13&16 are masked 049FH Lines 1,2,3,4,5,8&11 are masked
    600FH Lines 1,2,3,4,14&15 are masked 089FH Lines 1,2,3,4,5,8&12 are masked
    A00FH Lines 1,2,3,4,14&16 are masked 109FH Lines 1,2,3,4,5,8&13 are masked
    C00FH Lines 1,2,3,4,15&16 are masked 209FH Lines 1,2,3,4,5,8&14 are masked
    007FH Lines 1,2,3,4,5,6&7 are masked 409FH Lines 1,2,3,4,5,8&15 are masked
    00BFH Lines 1,2,3,4,5,6&8 are masked 809FH Lines 1,2,3,4,5,8&16 are masked
    013FH Lines 1,2,3,4,5,6&9 are masked 031FH Lines 1,2,3,4,5,9&10 are masked
    023FH Lines 1,2,3,4,5,6&10 are masked 051FH Lines 1,2,3,4,5,9&11 are masked 
    						
    							NECA 340-414-220 Revision 2.0 Page 13 of 18
    MCU 5000A Multipoint Control Unit SPR-011
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    091FH Lines 1,2,3,4,5,9&12 are masked C01FH Lines 1,2,3,4,5,15&16 are masked
    111FH Lines 1,2,3,4,5,9&13 are masked 00FFH Lines 1,2,3,4,5,6,7&8 are masked
    211FH Lines 1,2,3,4,5,9&14 are masked 017FH Lines 1,2,3,4,5,6,7&9 are masked
    411FH Lines 1,2,3,4,5,9&15 are masked 027FH Lines 1,2,3,4,5,6,7&10 are masked
    811FH Lines 1,2,3,4,5,9&16 are masked 047FH Lines 1,2,3,4,5,6,7&11 are masked
    061FH Lines 1,2,3,4,5,10&11 are masked 087FH Lines 1,2,3,4,5,6,7&12 are masked
    0A1FH Lines 1,2,3,4,5,10&12 are masked 107FH Lines 1,2,3,4,5,6,7&13 are masked
    121FH Lines 1,2,3,4,5,10&13 are masked 207FH Lines 1,2,3,4,5,6,7&14 are masked
    221FH Lines 1,2,3,4,5,10&14 are masked 407FH Lines 1,2,3,4,5,6,7&15 are masked
    421FH Lines 1,2,3,4,5,10&15 are masked 807FH Lines 1,2,3,4,5,6,7&16 are masked
    821FH Lines 1,2,3,4,5,10&16 are masked 01BFH Lines 1,2,3,4,5,6,8&9 are masked
    0C1FH Lines 1,2,3,4,5,11&12 are masked 02BFH Lines 1,2,3,4,5,6,8&10 are masked
    141FH Lines 1,2,3,4,5,11&13 are masked 04BFH Lines 1,2,3,4,5,6,8&11 are masked
    241FH Lines 1,2,3,4,5,11&14 are masked 08BFH Lines 1,2,3,4,5,6,8&12 are masked
    441FH Lines 1,2,3,4,5,11&15 are masked 10BFH Lines 1,2,3,4,5,6,8&13 are masked
    841FH Lines 1,2,3,4,5,11&16 are masked 20BFH Lines 1,2,3,4,5,6,8&14 are masked
    181FH Lines 1,2,3,4,5,12&13 are masked 40BFH Lines 1,2,3,4,5,6,8&15 are masked
    281FH Lines 1,2,3,4,5,12&14 are masked 80BFH Lines 1,2,3,4,5,6,8&16 are masked
    481FH Lines 1,2,3,4,5,12&15 are masked 033FH Lines 1,2,3,4,5,6,9&10 are masked
    881FH Lines 1,2,3,4,5,12&16 are masked 053FH Lines 1,2,3,4,5,6,9&11 are masked
    301FH Lines 1,2,3,4,5,13&14 are masked 093FH Lines 1,2,3,4,5,6,9&12 are masked
    501FH Lines 1,2,3,4,5,13&15 are masked 113FH Lines 1,2,3,4,5,6,9&13 are masked
    901FH Lines 1,2,3,4,5,13&16 are masked 213FH Lines 1,2,3,4,5,6,9&14 are masked
    601FH Lines 1,2,3,4,5,14&15 are masked 413FH Lines 1,2,3,4,5,6,9&15 are masked
    A01FH Lines 1,2,3,4,5,14&16 are masked 813FH Lines 1,2,3,4,5,6,9&16 are masked 
    						
    							Page 14 of 18 NECA 340-414-220 Revision 2.0
    SPR-011 MCU 5000A Multipoint Control Unit
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    063FH Lines 1,2,3,4,5,6,10&11 are masked 10FFH Lines 1,2,3,4,5,6,7,8&13 are masked
    0A3FH Lines 1,2,3,4,5,6,10&12 are masked 20FFH Lines 1,2,3,4,5,6,7,8&14 are masked
    123FH Lines 1,2,3,4,5,6,10&13 are masked 40FFH Lines 1,2,3,4,5,6,7,8&15 are masked
    223FH Lines 1,2,3,4,5,6,10&14 are masked 80FFH Lines 1,2,3,4,5,6,7,8&16 are masked
    423FH Lines 1,2,3,4,5,6,10&15 are masked 037FH Lines 1,2,3,4,5,6,7,9&10 are masked
    823FH Lines 1,2,3,4,5,6,10&16 are masked 057FH Lines 1,2,3,4,5,6,7,9&11 are masked
    0C3FH Lines 1,2,3,4,5,6,11&12 are masked 097FH Lines 1,2,3,4,5,6,7,9&12 are masked
    143FH Lines 1,2,3,4,5,6,11&13 are masked 117FH Lines 1,2,3,4,5,6,7,9&13 are masked
    243FH Lines 1,2,3,4,5,6,11&14 are masked 067FH Lines 1,2,3,4,5,6,7,10&11 are masked
    443FH Lines 1,2,3,4,5,6,11&15 are masked 0A7FH Lines 1,2,3,4,5,6,7,10&12 are masked
    843FH Lines 1,2,3,4,5,6,11&16 are masked 127FH Lines 1,2,3,4,5,6,7,10&13 are masked
    183FH Lines 1,2,3,4,5,6,12&13 are masked 227FH Lines 1,2,3,4,5,6,7,10&14 are masked
    283FH Lines 1,2,3,4,5,6,12&14 are masked 427FH Lines 1,2,3,4,5,6,7,10&15 are masked
    483FH Lines 1,2,3,4,5,6,12&15 are masked 827FH Lines 1,2,3,4,5,6,7,10&16 are masked
    883FH Lines 1,2,3,4,5,6,12&16 are masked 0C7FH Lines 1,2,3,4,5,6,7,11&12 are masked
    303FH Lines 1,2,3,4,5,6,13&14 are masked 147FH Lines 1,2,3,4,5,6,7,11&13 are masked
    503FH Lines 1,2,3,4,5,6,13&15 are masked 247FH Lines 1,2,3,4,5,6,7,11&14 are masked
    903FH Lines 1,2,3,4,5,6,13&16 are masked 447FH Lines 1,2,3,4,5,6,7,11&15 are masked
    603FH Lines 1,2,3,4,5,6,14&15 are masked 847FH Lines 1,2,3,4,5,6,7,11&16 are masked 
    						
    							NECA 340-414-220 Revision 2.0 Page 15 of 18
    MCU 5000A Multipoint Control Unit SPR-011
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    187FH Lines 1,2,3,4,5,6,7,12&13 are masked 81FFH Lines 1,2,3,4,5,6,7,8,9&16 are masked
    287FH Lines 1,2,3,4,5,6,7,12&14 are masked 06FFH Lines 1,2,3,4,5,6,7,8,10&11 are masked
    487FH Lines 1,2,3,4,5,6,7,12&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,10&12 are masked
    887FH Lines 1,2,3,4,5,6,7,12&16 are masked 12FFH Lines 1,2,3,4,5,6,7,8,10&13 are masked
    307FH Lines 1,2,3,4,5,6,7,13&14 are masked 22FFH Lines 1,2,3,4,5,6,7,8,10&14 are masked
    507FH Lines 1,2,3,4,5,6,7,13&15 are masked 42FFH Lines 1,2,3,4,5,6,7,8,10&15 are masked
    907FH Lines 1,2,3,4,5,6,7,13&16 are masked 82FFH Lines 1,2,3,4,5,6,7,8,10&16 are masked
    607FH Lines 1,2,3,4,5,6,7,14&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,11&12 are masked
    A07FH Lines 1,2,3,4,5,6,7,14&16 are masked 14FFH Lines 1,2,3,4,5,6,7,8,11&13 are masked
    C07FH Lines 1,2,3,4,5,6,7,15&16 are masked 24FFH Lines 1,2,3,4,5,6,7,8,11&14 are masked
    03FFH Lines 1,2,3,4,5,6,7,8,9&10 are masked 44FFH Lines 1,2,3,4,5,6,7,8,11&15 are masked
    05FFH Lines 1,2,3,4,5,6,7,8,9&11 are masked 84FFH Lines 1,2,3,4,5,6,7,8,11&16 are masked
    09FFH Lines 1,2,3,4,5,6,7,8,9&12 are masked 18FFH Lines 1,2,3,4,5,6,7,8,12&13 are masked
    11FFH Lines 1,2,3,4,5,6,7,8,9&13 are masked 28FFH Lines 1,2,3,4,5,6,7,8,12&14 are masked
    21FFH Lines 1,2,3,4,5,6,7,8,9&14 are masked 48FFH Lines 1,2,3,4,5,6,7,8,12&15 are masked
    41FFH Lines 1,2,3,4,5,6,7,8,9&15 are masked 88FFH Lines 1,2,3,4,5,6,7,8,12&16 are masked 
    						
    							Page 16 of 18 NECA 340-414-220 Revision 2.0
    SPR-011 MCU 5000A Multipoint Control Unit
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETE
    RLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETE
    RLINE NUMBER TO BE MASKED
    30FFH Lines 1,2,3,4,5,6,7,8,13&14 are masked 85FFH Lines 1,2,3,4,5,6,7,8,9,11&16 are masked
    50FFH Lines 1,2,3,4,5,6,7,8,13&15 are masked 19FFH Lines 1,2,3,4,5,6,7,8,9,12&13 are masked
    90FFH Lines 1,2,3,4,5,6,7,8,13&16 are masked 29FFH Lines 1,2,3,4,5,6,7,8,9,12&14 are masked
    60FFH Lines 1,2,3,4,5,6,7,8,14&15 are masked 49FFH Lines 1,2,3,4,5,6,7,8,9,12&15 are masked
    A0FFH Lines 1,2,3,4,5,6,7,8,14&16 are masked 89FFH Lines 1,2,3,4,5,6,7,8,9,12&16 are masked
    C0FFH Lines 1,2,3,4,5,6,7,8,15&16 are masked 31FFH Lines 1,2,3,4,5,6,7,8,9,13&14 are masked
    07FFH Lines 1,2,3,4,5,6,7,8,9,10&11 are masked 51FFH Lines 1,2,3,4,5,6,7,8,9,13&15 are masked
    0BFFH Lines 1,2,3,4,5,6,7,8,9,10&12 are masked 91FFH Lines 1,2,3,4,5,6,7,8,9,13&16 are masked
    13FFH Lines 1,2,3,4,5,6,7,8,9,10&13 are masked 61FFH Lines 1,2,3,4,5,6,7,8,9,14&15 are masked
    23FFH Lines 1,2,3,4,5,6,7,8,9,10&14 are masked A1FFH Lines 1,2,3,4,5,6,7,8,9,14&16 are masked
    43FFH Lines 1,2,3,4,5,6,7,8,9,10&15 are masked C1FFH Lines 1,2,3,4,5,6,7,8,9,15&16 are masked
    83FFH
    Lines 1,2,3,4,5,6,7,8,9,10&16 are masked0FFFH Lines 1,2,3,4,5,6,7,8,9,10,11&12 are 
    masked
    0DFFH
    Lines 1,2,3,4,5,6,7,8,9,11&12 are masked17FFH Lines 1,2,3,4,5,6,7,8,9,10,11&13 are 
    masked
    15FFH
    Lines 1,2,3,4,5,6,7,8,9,11&13 are masked27FFH Lines 1,2,3,4,5,6,7,8,9,10,11&14 are 
    masked
    25FFH
    Lines 1,2,3,4,5,6,7,8,9,11&14 are masked47FFH Lines 1,2,3,4,5,6,7,8,9,10,11&15 are 
    masked
    45FFH
    Lines 1,2,3,4,5,6,7,8,9,11&15 are masked87FFH Lines 1,2,3,4,5,6,7,8,9,10,11&16 are 
    masked 
    						
    							NECA 340-414-220 Revision 2.0 Page 17 of 18
    MCU 5000A Multipoint Control Unit SPR-011
    1.5M LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    1BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are 
    masked
    2BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are 
    masked
    4BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&15 are 
    masked
    8BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&16 are maskedA7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&16 are 
    masked
    33FFH
    Lines 1,2,3,4,5,6,7,8,9,10,13&14 are maskedC7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,15&16 are 
    masked
    53FFH
    Lines 1,2,3,4,5,6,7,8,9,10,13&15 are masked3FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&14 are 
    masked
    93FFH
    Lines 1,2,3,4,5,6,7,8,9,10,13&16 are masked5FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&15 are 
    masked
    63FFH
    Lines 1,2,3,4,5,6,7,8,9,10,14&15 are masked9FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&16 are 
    masked
    A3FFH
    Lines 1,2,3,4,5,6,7,8,9,10,14&16 are masked6FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&15 are 
    masked
    C3FFH
    Lines 1,2,3,4,5,6,7,8,9,10,15&16 are maskedAFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&16 are 
    masked
    1FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&13 are 
    maskedCFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 15&16 are 
    masked
    2FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&14 are 
    masked7FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13, 14&15 
    are masked
    4FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&15 are 
    maskedBFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 14&16 
    are masked
    8FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&16 are 
    maskedDFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 15&16 
    are masked
    37FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&14 are 
    maskedFFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 
    14,15&16 are masked 
    						
    							Page 18 of 18 NECA 340-414-220 Revision 2.0
    SPR-011 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-012
    1.5M LIF LINE EQUALIZER SETTING
    LINE RELATED
    SUMMARY:
    Set the physical properties of line.
    STEP PROCEDURE 
    Note:
    When connecting to a T1 line, set the equalizer value according to the cable distance.  In the 
    case of an NTT line, however, fix the value to “EQL-A” before use.  The line equalizer can 
    be set independently for each line.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address40H 
    to 4FH
    [1] Line numbers corresponding to the addresses (hexadecimal values) on setting the line equalizer.
    ADDRESS PHYSICAL LINE 
    NUMBERADDRESS PHYSICAL LINE 
    NUMBER
    40H 1 48H 9
    41H 2 49H 10
    42H 3 4AH 11
    43H 4 4BH 12
    44H 5 4CH 13
    45H 6 4DH 14
    46H 7 4EH 15
    47H 8 4FH 16 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-012 MCU 5000A Multipoint Control Unit
    1.5M LIF LINE EQUALIZER SETTING
    LINE RELATED
    STEP PROCEDURE 
    xi:System parameter values See  below: 
    [2] System parameter values on setting the line equalizer for the addresses 40H to 4FH.
    The factory shipment value for the system parameter applicable to all the lines is 
    00H.
    SYSTEM PARAMETER  LINE  EQUALIZER
    00H EQL-A (0 to 133 feet)
    01H EQL-B (133 to 267 feet)
    02H EQL-C (267 to 400 feet)
    03H EQL-D (400 to 533 feet)
    04H EQL-E (533 to 655 feet)
    2Verify that the normal response is displayed with “
    OK”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						