NECA 340-414-210 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit GSD-010 Table 2: LED Functions for VDSW Unit LED NAME COMPONENTS FUNCTION LED COLOR LED1 CONF AAMBER LED2 CONF BAMBER LED3-1 ~ LED3-4 LED4-1 ~ LED4-4JOIN RC1~RC8Indicates participants’ conference room. GREEN LED5-1 ~ LED5-4OPE (RC1 ~ RC8) Indicates the operator. GREEN LED6-1 ~ LED6-4VIDEO (RC1 ~ RC4) Indicates the broadcast sending terminal.GREEN LED7-1 ~ LED7-4LSD1 RC1 ~ RC4 Indicates the LSD broadcast sending terminal.GREEN LED8-1 ~ LED8-4MPL/LSD2 RC1 ~ RC4 Not usedGREEN LED9-1 ~ LED9-4HSD RC1 ~ RC4 Indicates the HSD broadcast sending terminal.GREEN LED11 PN ERR Indicates the alarm of the PN pattern. RED LED10 PN RCV Indicates no error in PN pattern. GREEN Table 3: LED5 ~ 9 Display CH CH RC4 RC3 RC2 RC1 1 mmml 2 mmlm 3 mmll 4 mlmm 5 mlml 6 mllm 7 mlll 8 lmmm l: lit m: unlit
Page 4 of 4 NECA 340-414-210 Revision 2.0 GSD-010 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 ISSUE 2 DOI-G05185 PART OF STOCK # 0293922 SYSTEM PARAMETERS MANUAL SEPTEMBER, 1998 NEC America, Inc. MCU 5000A MULTIPOINT CONTROL UNIT
LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its em- ployees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. Copyright 1998 NEC America, Inc. Printed in USA
NECA 340-414-220 Revision 2.0Page i MCU 5000A Multipoint Control Unit Table of Contents Table of Contents INTRODUCTION ................................................................................................. INT-001 CONSOLE RELATED CONSOLE INITIAL MESSAGE SETTING .................................................... SPR-001 CONSOLE COMMAND GENERATION SETTING........................................ SPR-002 CONSOLE COMMUNICATION PARAMETER SETTING ............................. SPR-003 CONSOLE CODE INDICATION SETTING ................................................... SPR-004 IDENTIFICATION CODE SETTING .............................................................. SPR-005 CONSOLE PORT SETTING ......................................................................... SPR-006 LINE RELATED 1.5M LIF LINE RATE SETTING .................................................................... SPR-007 1.5M LIF FRAME FORMAT SETTING .......................................................... SPR-008 1.5M LIF LINE CODE SETTING ................................................................... SPR-009 1.5M LIF RAI SETTING ................................................................................. SPR-010 1.5M LIF CLOCK SOURCE SETTING .......................................................... SPR-011 1.5M LIF LINE EQUALIZER SETTING ......................................................... SPR-012 RS 422 LIF LINE RATE SETTING ................................................................ SPR-013 RS 422 LIF CLOCK SOURCE SETTING ...................................................... SPR-014 H0-INF LIF LINE RATE SETTING................................................................. SPR-015 H0-INF LIF CLOCK SOURCE SETTING ...................................................... SPR-016 VOICE RELATED TALKER DETECTION BACKWARD PROTECTION TIME SETTING .......... SPR-017 TALKER DETECTION FORWARD PROTECTION TIME SETTING ............ SPR-018 TALKER DETECTION VOICE LEVEL SETTING .......................................... SPR-019 MAXIMUM TALKER SETTING...................................................................... SPR-020 MULTIPOINT TELECONFERENCE RELATED TALKER DETECTION (MCON) SETTING .................................................... SPR-021 AREA NAME DELETION SETTING .............................................................. SPR-022 H.242 CAPABILITY SWITCHING ACTION SETTING .................................. SPR-023 TALKER DETECTION (ECON) SETTING .................................................... SPR-024 TC5000 OPERATION MODE SETTING ....................................................... SPR-025 PICTURE RELATED PICTURE SWITCHING TIMERS 1 TO 4 SETTING ...................................... SPR-026
Page iiNECA 340-414-220 Revision 2.0 Table of Contents MCU 5000A Multipoint Control Unit TERMINAL CAPABILITY RELATED AUDIO CAPABILITY SETTING .................................................................... SPR-027 TRANSFER RATE CAPABILITY SETTING.................................................. SPR-028 VIDEO CAPABILITY SETTING .................................................................... SPR-029 LOW SPEED DATA (LSD) CAPABILITY SETTING ..................................... SPR-030 HIGH SPEED DATA (HSD) CAPABILITY SETTING .................................... SPR-031 MLP CAPABILITY SETTING ........................................................................ SPR-032 NETWORK CLASSIFICATION CAPABILITY SETTING............................... SPR-033 MBE CAPABILITY SETTING ........................................................................ SPR-035 MBE MESSAGE (AUDIO) CAPABILITY SETTING ...................................... SPR-036 MBE MESSAGE (LSD2) CAPABILITY SETTING......................................... SPR-037 MBE MESSAGE (VIDEO) CAPABILITY SETTING ...................................... SPR-038 AUDIO CAPABILITY ..................................................................................... SPR-101 TRANSFER RATE CAPABILITY .................................................................. SPR-102 VIDEO CAPABILITY SETTING .................................................................... SPR-103 LSD CAPABILITY SETTING......................................................................... SPR-104 HSD CAPABILITY SETTING ........................................................................ SPR-105 MLP CAPABILITY SETTING ........................................................................ SPR-106 NETWORK CLASSIFICATION CAPABILITY SETTING............................... SPR-107 MBE CAPABILITY SETTING ........................................................................ SPR-108 MBE MESSAGE 1 (AUDIO) CAPABILITY SETTING ................................... SPR-109 MBE MESSAGE 2 (PROPRIETARY) CAPABILITY SETTING ..................... SPR-110 MBE MESSAGE 3 (LSD2) CAPABILITY SETTING...................................... SPR-111 MBE MESSAGE 4 (VIDEO) CAPABILITY SETTING ................................... SPR-112 MBE MESSAGE CAPABILITY SETTING ..................................................... SPR-113 TIC CAPABILITY SETTING .......................................................................... SPR-114 CIC CAPABILITY SETTING ......................................................................... SPR-115 AUDIO MODE CAPABILITY SETTING ........................................................ SPR-116 TRANSFER RATE CAPABILITY SETTING.................................................. SPR-117
NECA 340-414-220 Revision 2.0Page iii MCU 5000A Multipoint Control Unit Table of Contents TERMINAL MODE RELATED AUDIO MODE SETTING ............................................................................... SPR-039 TRANSFER RATE MODE SETTING ............................................................ SPR-040 VIDEO MODE SETTING ............................................................................... SPR-041 LOW SPEED DATA (LSD) MODE SETTING ................................................ SPR-042 HIGH SPEED DATA (HSD) MODE SETTING .............................................. SPR-043 MLP MODE SETTING ................................................................................... SPR-044 NETWORK CLASSIFICATION MODE SETTING ......................................... SPR-045 MBE MODE SETTING .................................................................................. SPR-047 MBE MESSAGE (AUDIO) MODE SETTING ................................................. SPR-048 MBE MESSAGE (LSD2) MODE SETTING ................................................... SPR-049 MBE MESSAGE (VIDEO) MODE SETTING ................................................. SPR-050 VIDEO MODE SETTING ............................................................................... SPR-118 LSD MODE SETTING ................................................................................... SPR-119 HSD CAPABILITY SETTING......................................................................... SPR-120 MLP MODE SETTING ................................................................................... SPR-121 NETWORK CLASSIFICATION MODE SETTING ......................................... SPR-122 MBE MODE SETTING .................................................................................. SPR-123 MBE MESSAGE 1 (AUDIO) SETTING.......................................................... SPR-124 MBE MESSAGE 3 (LSD2) MODE SETTING ................................................ SPR-125 MBE MESSAGE 4 (VIDEO) MODE SETTING .............................................. SPR-126 RCON ACTION MODE SETTING ................................................................. SPR-127
Page ivNECA 340-414-220 Revision 2.0 Table of Contents MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 8 MCU 5000A Multipoint Control Unit INT-001 INTRODUCTION 1. GENERAL 1.01This document describes the information of system parameters for setting the Multipoint Control Unit 5000A (MCU 5000A). 2. OVERVIEW 2.01The MCU 5000A system parameters are for use in setting the operating environment for the MCU 5000A. After installing the MCU 5000A, the system parameters must be set conforming to user’s system operations by this manual. 2.02The system parameters are stored in the equipment’s backup memory and the contents of system parameters will be retained even if power is turned off. 3. SYSTEM PARAMETER SETTING3.01The system parameters can be set and verified by entering commands from the MCU console. The following provides a description of how to set and verify the system parameters. For further details, refer to the console operations section. Note 1: As to the system parameter values having 16-bit values, set the parameters in the numerical order of addresses sequentially starting with the lower-half 8 bits and then with the upper-half 8 bits. Note 2: When the equipment is powered up, the CRC values (3FE to 3FF) for checking the correctness of the system parameter contents are automatically updated simultaneously with the system parameter setting. Note 3: After setting the system parameters, be sure to restart the program with the MCONT unit reset switch. For some parameters are referred to only when initializing the system. How to set system parameters When setting system parameter values, the setting values for SSPR commands and system parameter addresses are entered from the console. SSPR *** = xx[return] *** : system parameter address (hexadecimal values 00 to 3FF) xx : system parameter setting values (hexadecimal values 00 to FF) When the normal system parameters are set, the console will display OK. If abnormal, an error code will be displayed. Verify the error code before repeating the procedure.
Page 2 of 8 NECA 340-414-220 Revision 2.0 INT-001 MCU 5000A Multipoint Control Unit How to verify system parameters After setting system parameters, verification of their correctness or details can be performed by entering RSPR commands from the console. RSPR *** [return] *** : system parameter address (hexadecimal values 0 to 3FF). If omitted, all the parameters will be displayed. If L is entered, the parameters for addresses 000 to 0FF will be displayed. If H is entered, the parameters for addresses 100 to 1FF will be displayed. If XL is entered, the parameters for addresses 200 to 2FF will be displayed. If XL is entered, the parameters for addresses 300 to 3FF will be displayed. In case of a normal response, the system parameter values that have been set will be displayed in the manner as follows. *** = xx OK *** : system parameter address xx : system parameter setting values If abnormal, an error code will be displayed. Verify the error code before repeating the procedure. System parameter initialization When initializing the system parameter values already set, enter an RRST command from the console. ISPR [return] Once the command is executed, the console will display OK. If abnormal, an error code will be displayed. Verify the error code before repeating the procedure. The factory shipment value for the system parameter is stored in the memory card.