    							NECA 340-414-300 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit COP-223
    RLCI
    Multipoint Teleconference Indication
    EXPLANATION
    This indication notifies that a terminal requests the MCU 5000A to perform or 
    release a remote loopback.
    RELATED 
    COMMANDNone
    FORMAT
    RLCI
    __g__r__x
    EXPLANATION OF PARAMETERS
    g= A or B
    Indicates the teleconference group name.
    r= 01 ~ 14
    Indicates the teleconference room number of a terminal which 
    requests a remote loopback.
    x= V, A, D, or 0
    Indicates the type of signal to be looped back.  If 0 is displayed, a 
    remote loopback is removed.
    V:  loop for video signal
    A:  loop for audio signal
    D:  loop for digital signal
    0 :  remote loopback is removed
    EXAMPLE
    RLCI
    __A__03__V (Note)
    Note:
    This means that loop setting for video signal is requested from the 
    terminal (VL5000).  In this case, video signal for line-side of the 
    teleconference room 3 in the teleconference group A is looped back. 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-223 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-300 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit COP-224
    ERRI
    Multipoint Teleconference Indication
    EXPLANATION
    This indication notifies the following status.
    • Unmounted units 
    •LIF
    •PG/SIO
    •MUX
    • VSW/LSD
    • A-CODEC
    •A-SUM
    • Hardware initialization error
    RELATED 
    COMMANDNone
    FORMAT
    ERRI HARDWARE INITIAL ERROR tttt uu ee
    EXPLANATION OF PARAMETERS
    e= FE or FF
    Indicates the type of error.  Valid values for e are:
    FE: Hardware initializing error (hexadecimal)
    FF: Unit mounting error (hexadecimal)
    t: Indicates a task.
    u= Indicates the unit generated error.  Valid values for u are:
    11 ~ 14 : LIF #1 ~ #4
    20 : PG/SIO
    41 ~ 48 : MUX #1 ~ #8
    80 : VSW/LSD
    81 : VDSW
    A1 ~ A2 : A CODEC #1 ~ #2
    B0 : A SUM
    EXAMPLE
    ERRI
    __FE__1520__10__01
    ERRI HARDWARE INITIAL ERROR 1490 B0 FE 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-224 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-300 Revision 2.0 Page 1 of 4
    MCU 5000A Multipoint Control Unit COP-225
    CSTI
    Multipoint Teleconference Indication
    EXPLANATION
    This indication notifies that the status of a terminal is changed in multi point 
    connection.
    RELATED 
    COMMANDNone
    FORMAT
    CSTI
    __g__r__a__b__c__d__e__f__h__i__j__k
    EXPLANATION OF PARAMETERS
    g= A or B
    Indicates the teleconference group name.
    r= 1 ~ 14
    Indicate the teleconference room number of a terminal of which the 
    status is changed.
    a= 1 or 0
    Indicates whether a terminal is participating in the teleconference or 
    not.
    1:  participating
    0:  not participating
    b= 1 or 0
    Indicates whether a terminal unit is connecting or not
    1:  connecting
    0:  not connecting
    c= 1 or 0
    Indicates that a terminal detects a voice or not:
    1:  detecting
    0:  not detecting
    d= 1 or 0
    Indicates that the position of a microphone switch.
    1:  ON
    0:  OFF
    e= 1 or 0
    Indicates whether a speech is requesting or not:
    1:  requesting
    0:  not requesting 
    						
    							Page 2 of 4 NECA 340-414-300 Revision 2.0
    COP-225 MCU 5000A Multipoint Control Unit
    CSTI
    Multipoint Teleconference Indication
    (continued)
    EXPLANATION OF PARAMETERS
    f= 00 ~ 14
    Indicates the teleconference room number assigned the operator 
    privilege.  If 00 is displayed, the operator privilege is not assigned 
    to any terminal.
    h= 01 ~ 14
    Indicates the teleconference room number of broadcasting terminal.
    i= 00 ~ 14
    Indicates the teleconference room number of terminal from which 
    the picture is received by a broadcasting terminal.
    j= 00 ~ 14
    Indicates the teleconference room number of a transmit terminal 
    from which the picture is received.  If 00 is displayed, the picture 
    from a transmit terminal is not received.
    k= 00 ~ 14
    Indicates the teleconference room number of a instructor terminal 
    in ECON mode.  If 00 is displayed, MCON mode is established.
    Note 1:
    Indicators a through e express the operation status for each teleconference 
    room.  See table.
     
    Note 2:
    Indicators f through k express the information of a specified 
    teleconference room.  See table.
    EXAMPLE
    CSTI
    __A__05__0007__0007__0007__0007__0000__00__02
    03
    __00 
    						
    							NECA 340-414-300 Revision 2.0 Page 3 of 4
    MCU 5000A Multipoint Control Unit COP-225
    CSTI
    Multipoint Teleconference Indication
    (continued)
                      STATUS
     RESPONCE
     FORMTELECONFERENCE
     ROOM NUMBER                  STATUS
     RESPONCE
     FORMTELECONFERENCE 
    ROOM NUMBER
    1234 5678
    XXX00000 XX0X 0000
    XXX11000 XX1X 1000
    XXX20100 XX2X 0100
    XXX31100 XX3X 1100
    XXX40010 XX4X 0010
    XXX51010 XX5X 1010
    XXX60110 XX6X 0110
    XXX71110 XX7X 1110
    XXX80001 XX8X 0001
    XXX91001 XX9X 1001
    XXXA0101XXAX0101
    XXXB1101 XXBX 1101
    XXXC0011 XXCX 0011
    XXXD1011XXDX1011
    XXXE0111 XXEX 0111
    XXXF1111 XXFX 1111
    X=0 or 1 X=0 or 1 
    						
    							Page 4 of 4 NECA 340-414-300 Revision 2.0
    COP-225 MCU 5000A Multipoint Control Unit
    CSTI
    Multipoint Teleconference Indication
    (continued)
            
     
                                   STATUS
     RESPONCE
     FORMTELECONFERENCE 
    ROOM NUMBER
    9101112
    X0XX 0000
    X1XX 1000
    X2XX 0100
    X3XX 1100
    X4XX 0010
    X5XX 1010
    X6XX 0110
    X7XX 1110
    X8XX 0001
    X9XX 1001
    XAXX0101
    XBXX 1101
    XCXX 0011
    XDXX1011
    XEXX 0111
    XFXX 1111
    X=0 or 1
                                    STATUS
     RESPONCE
     FORMTELECONFERENCE ROOM 
    NUMBER
    13 14
    0XXX 0 0
    1XXX 1 0
    2XXX 0 1
    3XXX 1 1
    X=0 or 1 
    						
    							NECA 340-414-300 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit COP-226
    CSTI 
    
    Multipoint Teleconference Indication
    RESPOSE FORMAT
    g  r  abcde  fff  hhh  jjj  kkk  ll  mmm  nnn  oo  ppp  qqq  rrr  OK
    EXPLANATION OF RESPONSE PARAMETER
    a ~ e indicate operator status of specific conference room
    a = Participation status 1: Participation 0: No participation
    b = Conference terminal 1: Connection 0: No connection
    c = Voice detection function 1: Valid 0: Invalid
    d = Permission or speech status 1: Permit 0: Prohibit
    e = Request for speech status 1: Request 0: No request
    In fff ~ rrr, information which concern specific conference room will be 
    indicated.
    fff = Conference room number (00 ~ 252) with operating authority.
    When 00, there is no operator.
    hhh = Conference room number (01 ~ 252) of transmission source.
    jjj = Conference room number (01 ~ 252) which is received by the 
    terminal of transmission source.
    kkk = Conference room number (01 ~ 252) of original broadcasting 
    source.
    lll = Conference room number (01 ~ 252) which is received by the 
    terminal of original broadcasting source.
    mmm = Conference room number (01 ~ 252) of send picture of its own.
    nnn = Conference room number (01 ~ 252) received by sending 
    terminal when receiving specific picture.
    ooo = Conference room number (01 ~ 252) of original received by 
    terminal when receiving specific picture.
    ppp = Conference room number (01 ~ 252) of original specific 
    broadcast terminal.
    qqq = Conference room number (01 ~ 252) of original LSD 
    transmission.
    rrr = Conference room number (01 ~ 252) of original HSD 
    transmission. 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-226 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    All NEC manuals Comments (0)