NEC Mcu 5000a Multipoint Control Unit Equipment Manual
Have a look at the manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-103 VIDEO CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the H.261 defined video capability. STEP PROCEDURE Note: Set the video capability with the factory shipment value (22H 02H ). If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter addressA: 208H and 209H B: 268H and 269H [1] Video capability corresponding to the addresses (hexadecimal values) in setting the video capability. The video capability is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits. ADDRESSVIDEO CAPABILITY SETTING (1: ON, 0: OFF) REMARKS BIT A: 208H B: 268H0 QCIF Set either one of the two bits to 1. (NOTE) 1 QCIF and QCIF 2 QCIF: 4/29.97 Only one of these four bits should be set to 1. (NOTE) 3 QCIF: 3/29.97 4 QCIF: 2/29.97 5 QCIF: 1/29.97 6 CIF: 4/29.97 Only one of these four bits should be set to 1. (NOTE) 7 CIF: 3/29.97 A: 209H B: 269H0 CIF: 2/29.97 1 CIF: 1/29.97 2 ~ 7 Not used, fixed to 0 _ Note: If none of the bits or more than one of the bits are set to 1, video capability is not guaranteed.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-103 MCU 5000A Multipoint Control Unit VIDEO CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the video capability for the addresses 108H and 109H. The factory shipment value for the system parameter is 22H 02H . SYSTEM PARAMETER VIDEO CAPABILITY ADDRESS A: 209H B: 269HADDRESS A: 208H B: 268H 00H 05H QCIF: 4/29.79 is ON 00H 09H QCIF: 3/29.79 is ON 00H 11H QCIF: 2/29.79 is ON 00H 21H QCIF: 1/29.79 is ON 00H 46H QCIF: 4/29.79 and CIF: 4/29.97 are ON. 00H 86H QCIF: 4/29.79 and CIF: 3/29.97 are ON. 01H 06H QCIF: 4/29.79 and CIF: 2/29.97 are ON. 02H 06H QCIF: 4/29.79 and CIF: 1/29.97 are ON. 00H 4AH QCIF: 3/29.79 and CIF: 4/29.97 are ON. 00H 8AH QCIF: 3/29.79 and CIF: 3/29.97 are ON. 01H 0AH QCIF: 3/29.79 and CIF: 2/29.97 are ON. 02H 0AH QCIF: 3/29.79 and CIF: 1/29.97 are ON. 00H 52H QCIF: 2/29.79 and CIF: 4/29.97 are ON. 00H 92H QCIF: 2/29.79 and CIF: 3/29.97 are ON. 01H 12H QCIF: 2/29.79 and CIF: 2/29.97 are ON. 02H 12H QCIF: 2/29.79 and CIF: 1/29.97 are ON. 00H 62H QCIF: 1/29.79 and CIF: 4/29.97 are ON. 00H A2H QCIF: 1/29.79 and CIF: 3/29.97 are ON. 01H 22H QCIF: 1/29.79 and CIF: 2/29.97 are ON. 02H 22H QCIF: 1/29.79 and CIF: 1/29.97 are ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-104 LSD CAPABILITY SETTING TERMINAL CAPABILITY RELATED LSD Capability (A: +20AH ~ 20BH) (B: +26AH ~ +26BH) b7 b6b5 b4 b3 b2 b1 b0 b2 : 1200 bps b3 : 4800 bpsDefault = 00H A: +20AH 00 0 fixed0000 fixed 0 fixed b4 : 6400 bps b6 : 9600 bps B: +26AH b7 : 14,400 bps b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +20BH B: +26BH
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-104 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-105 HSD CAPABILITY SETTING TERMINAL CAPABILITY RELATED HSD Capability (A: +20CH ~ 20FH) (B: +26CH ~ +26FH) b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +20CH B: +26CH b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed000 0 0 A: +20DH B: +26DH b1 : 64 kbps b2 : 128 kbps b3 : 192 kbps b4 : 256 kbps b6 : 384 kbps Note: When distributing HSD date, bit will be 1.0 fixed 0 fixed b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 0 fixed0 A: +20EH B: +26EH b0 : 768 kbps (R) b2 : 1536 kbps (R) Note: When distributing HSD date, bit will be 1.0 fixed 0 fixed 0 fixed 0 fixed 0 fixed Default = 00H A: +20FH B: +26FH b7 b6b5 b4 b3 b2 b1 b0 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-105 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-106 MLP CAPABILITY SETTING TERMINAL CAPABILITY RELATED MLP Capability (A: +210H ~ 211H) (B: +270H ~ +271H) b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 00 fixed A: +210H B: +270H b1 : MLP-4k b2 : MLP-6k b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +211H B: +271H
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-106 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-107 NETWORK CLASSIFICATION CAPABILITY SETTING TERMINAL CAPABILITY RELATED Network Classification Capability (A: +212H ~ 213H) (B: +272H ~ +273H) b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 00 fixed A: +212H B: +272H b1 : 56 kbps (restricted)0 fixed b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed A: +213H B: +273H
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-107 MCU 5000A Multipoint Control Unit This page is for your notes.