    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-020
    MAXIMUM TALKER SETTING
    VOICE RELATED
    SUMMARY:  
    Restrict the number of the talkers who are allowed to talk simultaneously on a 
    voice channel.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ø
    ni:
    System parameter address53H
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the number of talkers.  The factory shipment value 
    is 00H
    .
    SYSTEM 
    PARAMETERNUMBER OF TALKERS
    00H Unlimited
    01H Only the last 3 talkers before this setting is enabled 
    are allowed to talk.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-020 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-021
    TALKER DETECTION (MCON) SETTING
    MULTIPOINT TELECONFERENCE RELATED
    SUMMARY: 
    Set the talker detection to ON or OFF when MCON is executed.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address70H
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting for talker detection.  The factory shipment value 
    is 00H
    .
    SYSTEM PARAMETER TALKER DETECTION
    00H Detected (automatic detection)
    80H Not Detected (manual detection)
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-021 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-022
    AREA NAME DELETION SETTING
    MULTIPOINT TELECONFERENCE RELATED
    SUMMARY: 
    Set the deletion of area name to ON or OFF when MDSC is executed.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address73H
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the deletion of area name.  The factory shipment 
    value is 00H
    .
    SYSTEM PARAMETER AREA NAME
    00H Not deleted
    01H Deleted
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-022 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-023
    H.242 CAPABILITY SWITCHING ACTION SETTING
    MULTIPOINT TELECONFERENCE RELATED 
    SUMMARY:
    Set whether or not to perform ITU-T Recommendation H.242 defined capability 
    switching to and from connecting terminal (VL 5000).  When the capability 
    switching is performed, it is necessary to confirm all the participating terminals 
    have the same capability.  Terminals having different capabilities cannot 
    participate in the multipoint video teleconference.
    STEP PROCEDURE 
    Note:
    When capability switching is not performed, any terminals irrespective of capability can 
    participate in the conference.  However, difference in terminal capability is conducive to 
    occurrence of phenomena such as non-display of picture.  Be sure, therefore, to set all the 
    terminal-side CODECs to capability non switching mode in case capability switching is not 
    required.  Also see that all the terminal-side CODECs have the same capability setting as in 
    MCU 5000A.  Moreover, if broadcast switching (UCON and LCON commands) is intended, 
    never fail to use all the terminals in capability non switching mode because the CODECs on 
    the terminal side cannot perform capability switching among themselves by both-way 
    communication at the time of broadcast  switching.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address77H
    x
    i:
    System parameter values See below:
    [1] System parameter values  on setting the H.242 capability switching action for the 
    address 77H.
    The factory shipment value for the system parameter is 80H
    .
    SYSTEM PARAMETER  H.242 CAPABILITY SWITCHING SETTING
    00H Not performed
    80H Performed
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-023 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-024
    TALKER DETECTION (ECON) SETTING
    MULTIPOINT TELECONFERENCE RELATED
    SUMMARY:
    Set the talker detection to ON or OFF when ECON is executed.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address88H
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the talker detection.  The factory shipment value 
    is 00H
    .
    SYSTEM PARAMETER TALKER DETECTION
    00H Detected (automatic detection)
    01H Not detected (manual detection)
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-024 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						