NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-020 MAXIMUM TALKER SETTING VOICE RELATED SUMMARY: Restrict the number of the talkers who are allowed to talk simultaneously on a voice channel. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ø ni: System parameter address53H x i: System parameter values See below: [1] System parameter values on setting the number of talkers. The factory shipment value is 00H . SYSTEM PARAMETERNUMBER OF TALKERS 00H Unlimited 01H Only the last 3 talkers before this setting is enabled are allowed to talk. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-020 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-021 TALKER DETECTION (MCON) SETTING MULTIPOINT TELECONFERENCE RELATED SUMMARY: Set the talker detection to ON or OFF when MCON is executed. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address70H x i: System parameter values See below: [1] System parameter values on setting for talker detection. The factory shipment value is 00H . SYSTEM PARAMETER TALKER DETECTION 00H Detected (automatic detection) 80H Not Detected (manual detection) 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-021 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-022 AREA NAME DELETION SETTING MULTIPOINT TELECONFERENCE RELATED SUMMARY: Set the deletion of area name to ON or OFF when MDSC is executed. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address73H x i: System parameter values See below: [1] System parameter values on setting the deletion of area name. The factory shipment value is 00H . SYSTEM PARAMETER AREA NAME 00H Not deleted 01H Deleted 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-022 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-023 H.242 CAPABILITY SWITCHING ACTION SETTING MULTIPOINT TELECONFERENCE RELATED SUMMARY: Set whether or not to perform ITU-T Recommendation H.242 defined capability switching to and from connecting terminal (VL 5000). When the capability switching is performed, it is necessary to confirm all the participating terminals have the same capability. Terminals having different capabilities cannot participate in the multipoint video teleconference. STEP PROCEDURE Note: When capability switching is not performed, any terminals irrespective of capability can participate in the conference. However, difference in terminal capability is conducive to occurrence of phenomena such as non-display of picture. Be sure, therefore, to set all the terminal-side CODECs to capability non switching mode in case capability switching is not required. Also see that all the terminal-side CODECs have the same capability setting as in MCU 5000A. Moreover, if broadcast switching (UCON and LCON commands) is intended, never fail to use all the terminals in capability non switching mode because the CODECs on the terminal side cannot perform capability switching among themselves by both-way communication at the time of broadcast switching. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address77H x i: System parameter values See below: [1] System parameter values on setting the H.242 capability switching action for the address 77H. The factory shipment value for the system parameter is 80H . SYSTEM PARAMETER H.242 CAPABILITY SWITCHING SETTING 00H Not performed 80H Performed 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-023 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-024 TALKER DETECTION (ECON) SETTING MULTIPOINT TELECONFERENCE RELATED SUMMARY: Set the talker detection to ON or OFF when ECON is executed. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address88H x i: System parameter values See below: [1] System parameter values on setting the talker detection. The factory shipment value is 00H . SYSTEM PARAMETER TALKER DETECTION 00H Detected (automatic detection) 01H Not detected (manual detection) 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.