NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-038 MBE MESSAGE (VIDEO) CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the expansion video capability of connecting CODEC (VL 5000). STEP PROCEDURE Note: Use the MBE message (video) capability with the factory shipment value (04H 00H ). If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address11C H and 11DH [1] Addresses (hexadecimal values) on setting the MBE message (video) capability. The MBE message (video) capability is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits, or specifically by setting bit 0 to bit 2 in the lower-half 8 bits to “1” or “0”. Accordingly, since the upper-half 8 bits are always “00H”, set only the lower-half 8 bits (address 11CH). ADDRESS MBE MESSAGE (VIDEO) 11CH Lower-half 8 bits setting address (b0 to b7) 11DH Upper-half 8 bits setting address (b8 to b15) xi: System parameter values See below: [1] System parameter values on setting the MBE message (video) capability for the addresses 11CH and 11DH. The factory shipment value for the system parameter is 04H 00H .
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-038 MCU 5000A Multipoint Control Unit MBE MESSAGE (VIDEO) CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE SYSTEM PARAMETER MBE MESSAGE (VIDEO) CAPABILITY ADDRESS 11 D HADDRESS 11 C H 00H 00H OFF 00H 01H PTY is ON. 00H 02H PTY + FULL are ON. 00H 04H PTY + FULL + VSP are ON. Note: PTY detects a parity error and performs Demand Refresh on its occurrence. FULL: NTSC full resolution mode VSP: dual screen multiplex mode 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-039 AUDIO MODE SETTING TERMINAL MODE RELATED SUMMARY: Set audio mode. If all the terminal CODECs (VL 5000s) are equipped with SB- ADPCM audio CODEC (7 kHz band) features, set the audio mode to “G.722 mode 2 (P×64k network)” or “G.722 mode 3 (p×56k network)”. If not, set it to “µ -LAW and OF” and refrain from setting other values. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address120H and 123H [1] Addresses (hexadecimal values) on setting the audio mode. The audio mode capability is set in hexadecimal values by dividing the 32 bits (b0 to b31) into four-quarter 8 bits. ADDRESS AUDIO MODE CAPABILITY 120H Fourth-quarter 8 bits setting address (b0 to b7) 121H Third-quarter 8 bits setting address (b8 to b15) 122H Second-quarter 8 bits setting address (b16 to b23) 123H First-quarter 8 bits setting address (b24 to b31) xi: System parameter valuesSee below: [1] System parameter values on setting the audio mode capability for the addresses 120H to 123H. The factory shipment value for the system parameter is 20H 00H 00H 00H .
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-039 MCU 5000A Multipoint Control Unit AUDIO MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER AUDIO MODE CAPABILITY ADDRESS 123HADDRESS 122HADDRESS 121HADDRESS 120H 00H 00H 00H 04Hm-law, OU is ON. 00H 00H 00H 08Hm-law, OF (u7) is ON. 00H 00H 00H 10H G.722 mode 1 is ON. 00H 00H 00H 20H G.722 mode 2 is ON. 00H 00H 00H 40H G.722 mode 3 is ON. 00H 04H 00H 00Hm-law, OF (u6) is ON. 40H 00H 00H 00H Audio OFF, U is ON. 80H 00H 00H 00H Audio OFF, F is ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit SPR-040 TRANSFER RATE MODE SETTING TERMINAL MODE RELATED SUMMARY: Set the transfer rate for terminal. STEP PROCEDURE Note: If rate is specified when setting up the multipoint teleconference by MCON or ECON command, the MCON or ECON command specified rate is set. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address124H and 127H [1] Addresses (hexadecimal values) on setting the transfer rate modes. The transfer rate mode is set in hexadecimal values by dividing the 32 bits (b0 to b31) into four- quarter 8 bits. ADDRESS TRANSFER RATE MODE SETTING 124H For 64 kb/s, 64 kb/s×2, 128 kb/s or 192 kb/s 125H For 256 kb/s, 384 kb/s, 512 kb/s, 768 kb/s, or 384 kb/s x 2 126H For 1152 kb/s, 1536 kb/s, 1920 kb/s, or 1472 kb/s 127H Not used LINE INTERFACE AVAILABLE TRANSFER RATE T1 64 kb/s, 128 kb/s, 192 kb/s, 256 kb/s, 384 kb/s, 512 kb/s, 768 kb/s, 1152 kb/s, 1536 kb/s, 64 kb/s x 2, 384 kb/s x 2, and 1472 kb/s RS 422 64 kb/s, 64 kb/s×2, 128 kb/s, 192 kb/s, 256 kb/s, 384 kb/s, 512 kb/s, 768 kb/s, 1152 kb/s, 1536 kb/s, 1920 kb/s, and 384 kb/s x 2 INS 64 kb/s, 64 kb/s×2, 384 kb/s, and 384 kb/s x 2
Page 2 of 4 NECA 340-414-220 Revision 2.0 SPR-040 MCU 5000A Multipoint Control Unit TRANSFER RATE MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the transfer rate mode for the addresses 124H to 127H. The factory shipment value for the system parameter is 00H 02H 00H 00H . SYSTEM PARAMETER Transfer rate mode ADDRESS 127HADDRESS 126HADDRESS 125HADDRESS 124H 00H 00H 00H 01H 64 kb/s is ON. 00H 00H 00H 02H 64 kb/s x 2 is ON. 00H 00H 00H 04H 128 kb/s is ON. 00H 00H 00H 08H 192 kb/s is ON. 00H 00H 01H 00H 256 kb/s is ON. 00H 00H 02H 00H 384 kb/s is ON. 00H 00H 40H 00H 512 kb/s is ON. 00H 00H 80H 00H 768 kb/s is ON. 00H 01H 00H 00H 1152 kb/s is ON. 00H 04H 00H 00H 1536 kb/s is ON. 00H 08H 00H 00H 1920 kb/s is ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit SPR-040 TRANSFER RATE MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE Transfer Rate Mode (+124H ~ 127H) b7 b6b5 b4 b3 b2 b1 b0 b0 : 64 kbps (T1/RS422/INF-H0) b1 : 64 x 2 kbps (T1/RS422/INS-H0)Default = 00H +124H00 0 fixed0 fixed 0 fixed0 fixed 0 0 b6 : 128 kbps (T1/RS422) b7 : 192 kbps (T1/RS422) b7 b6b5 b4 b3 b2 b1 b0 b0 : 256 kbps (T1/RS422) b1 : 384 kbps (T1/RS422/INS-H0)Default = 02H +125H00 0 fixed0 fixed 0 fixed0 1 0 b2 : 384 x 2 kbps (T1/RS422/INF-H0) b6 : 512 kbps (T1/RS422) b7 : 768 kbps (T1/RS422) b7 b6b5 b4 b3 b2 b1 b0 b0 : 1152 kbps (T1/RS422) b1 : 1472 kbps (T1)Default = 00H +126H00 0 0 b2 : 1536 kbps (T1/RS422) b3 : 1920 kbps (RS422) b7 b6b5 b4 b3 b2 b1 b0 Default = 00H +127H
Page 4 of 4 NECA 340-414-220 Revision 2.0 SPR-040 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-041 VIDEO MODE SETTING TERMINAL MODE RELATED SUMMARY: Specify whether video mode is set or not. STEP PROCEDURE Note: Use the factory shipment value (08H 00H ) in setting the video mode as a general rule. If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address128H and 129H [1] Addresses (hexadecimal values) in setting the video mode. The video mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits, or specifically by setting bit 3 in the lower-half 8 bits to “1” or “0”. Accordingly, since the upper-half 8 bits are always “00H”, set only the lower-half 8 bits (address 128H). ADDRESS VIDEO MODE 128H Lower-half 8 bits setting address (b0 to b7) 129H Upper-half 8 bits setting address (b8 to b15) xi:System parameter values See below: [1] System parameter values on setting the video mode for the addresses. The factory shipment value for the system parameter is 08H 00H . SYSTEM PARAMETER VIDEO MODE ADDRESS 129HADDRESS 128H 00H 00H OFF 00H 08H ON (H.261 video)
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-041 MCU 5000A Multipoint Control Unit VIDEO MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.