    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-038
    MBE MESSAGE (VIDEO) CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    SUMMARY: 
    Set the expansion video capability of connecting CODEC (VL 5000).
    STEP PROCEDURE 
    Note:
    Use the MBE message (video) capability with the factory shipment value (04H 00H
    ).  If 
    change is necessary for any reason, follow the steps described below.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address11C H  
    and 11DH
    [1] Addresses (hexadecimal values) on setting the MBE message (video) capability.  
    The MBE message (video) capability is set in hexadecimal values by dividing the 16 
    bits (b0 to b15) into the upper-half and lower-half 8 bits, or specifically by setting 
    bit 0 to bit 2 in the lower-half 8 bits to “1” or “0”.  Accordingly, since the upper-half 
    8 bits are always “00H”, set only the lower-half 8 bits (address 11CH).
    ADDRESS  MBE MESSAGE (VIDEO)
    11CH  Lower-half 8 bits setting address (b0 to b7)
    11DH Upper-half 8 bits setting address (b8 to b15)
    xi:
    System parameter values See  below:
    [1] System parameter values on setting the MBE message (video) capability for the 
    addresses 11CH and 11DH.
    The factory shipment value for the system parameter is 04H 00H
    . 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-038 MCU 5000A Multipoint Control Unit
    MBE MESSAGE (VIDEO) CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETER
    MBE MESSAGE (VIDEO) CAPABILITY 
    ADDRESS
    11 D HADDRESS
    11 C H
    00H 00H OFF
    00H 01H PTY is ON.
    00H 02H PTY + FULL are ON.
    00H 04H PTY + FULL + VSP are ON.
    Note:
    PTY detects a parity error and performs Demand Refresh on  its occurrence.
    FULL: NTSC full resolution mode 
    VSP: dual screen multiplex mode
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-039
    AUDIO MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY: 
    Set audio mode.  If all the terminal CODECs (VL 5000s) are equipped with SB-
    ADPCM audio CODEC (7 kHz band) features, set the audio mode to “G.722 
    mode 2 (P×64k network)” or “G.722 mode 3 (p×56k network)”.  If not, set it to 
    “µ -LAW and OF” and refrain from setting other values.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address120H 
    and 123H
    [1] Addresses (hexadecimal values) on setting the audio mode.
    The audio mode capability is set in hexadecimal values by dividing the 32 bits (b0 to 
    b31) into four-quarter 8 bits.
    ADDRESS AUDIO MODE CAPABILITY
    120H  Fourth-quarter 8 bits setting address (b0 to b7)
    121H Third-quarter 8 bits setting address (b8 to b15)
    122H  Second-quarter 8 bits setting address (b16 to b23)
    123H First-quarter 8 bits setting address (b24 to b31)
    xi: System parameter valuesSee  below:
    [1] System parameter values on setting the audio mode capability for the addresses 120H 
    to 123H.
    The factory shipment value for the system parameter is 20H 00H 00H 00H
    . 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-039 MCU 5000A Multipoint Control Unit
    AUDIO MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETER
    AUDIO MODE CAPABILITY
    ADDRESS
    123HADDRESS
    122HADDRESS
    121HADDRESS
    120H
    00H 00H 00H 04Hm-law, OU is ON.
    00H 00H 00H 08Hm-law, OF (u7) is ON.
    00H 00H 00H 10H G.722 mode 1 is ON.
    00H 00H 00H 20H G.722 mode 2 is ON.
    00H 00H 00H 40H G.722 mode 3 is ON.
    00H 04H 00H 00Hm-law, OF (u6) is ON.
    40H 00H 00H 00H Audio OFF, U is ON.
    80H 00H 00H 00H Audio OFF, F is ON.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 4
    MCU 5000A Multipoint Control Unit SPR-040
    TRANSFER RATE MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY:
    Set the transfer rate for terminal.
    STEP PROCEDURE 
    Note:
    If rate is specified when setting up the multipoint teleconference by MCON or ECON 
    command, the MCON or ECON command specified rate is set.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address124H 
    and 127H
    [1] Addresses (hexadecimal values) on setting the transfer rate modes.  The transfer rate 
    mode is set in hexadecimal values by dividing the 32 bits (b0 to b31) into four-
    quarter 8 bits.
    ADDRESS  TRANSFER RATE MODE SETTING
    124H For 64 kb/s, 64 kb/s×2, 128 kb/s or 192 kb/s
    125H For 256 kb/s, 384 kb/s, 512 kb/s, 768 kb/s, or 384 kb/s x 2
    126H For 1152 kb/s, 1536 kb/s, 1920 kb/s, or 1472 kb/s
    127H Not used
    LINE INTERFACE AVAILABLE TRANSFER RATE
    T1 64 kb/s, 128 kb/s, 192 kb/s, 256 kb/s, 384 kb/s, 512 kb/s, 768 kb/s, 1152 kb/s, 1536 kb/s, 64 kb/s x 2, 
    384 kb/s x 2, and 1472 kb/s
    RS 422 64 kb/s, 64 kb/s×2, 128 kb/s, 192 kb/s, 256 kb/s, 384 kb/s, 512 kb/s, 768 kb/s, 1152 kb/s, 1536 kb/s, 
    1920 kb/s, and 384 kb/s x 2
    INS 64 kb/s, 64 kb/s×2,  384 kb/s, and 384 kb/s x 2 
    						
    							Page 2 of 4 NECA 340-414-220 Revision 2.0
    SPR-040 MCU 5000A Multipoint Control Unit
    TRANSFER RATE MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the transfer rate mode for the addresses 124H to 
    127H.
    The factory shipment value for the system parameter is 00H 02H 00H 00H
    .
    SYSTEM PARAMETER
    Transfer rate mode 
    ADDRESS
    127HADDRESS
    126HADDRESS
    125HADDRESS
    124H
    00H 00H 00H 01H 64 kb/s is ON.
    00H 00H 00H 02H 64 kb/s x 2 is ON.
    00H 00H 00H 04H 128 kb/s is ON.
    00H 00H 00H 08H 192 kb/s is ON.
    00H 00H 01H 00H 256 kb/s is ON.
    00H 00H 02H 00H 384 kb/s is ON.
    00H 00H 40H 00H 512 kb/s is ON.
    00H 00H 80H 00H 768 kb/s is ON.
    00H 01H 00H 00H 1152 kb/s is ON.
    00H 04H 00H 00H 1536 kb/s is ON.
    00H 08H 00H 00H 1920 kb/s is ON.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 3 of 4
    MCU 5000A Multipoint Control Unit SPR-040
    TRANSFER RATE MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    Transfer Rate Mode (+124H ~ 127H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    b0 : 64 kbps              (T1/RS422/INF-H0)
    b1 : 64 x 2 kbps        (T1/RS422/INS-H0)Default = 00H +124H00
    0 fixed0 fixed 0 fixed0 fixed 0
    0
    b6 : 128 kbps             (T1/RS422)
    b7 : 192 kbps             (T1/RS422)
    b7
    b6b5
    b4 b3 b2 b1 b0
    b0 : 256 kbps                   (T1/RS422)
    b1 : 384 kbps                  (T1/RS422/INS-H0)Default = 02H +125H00
    0 fixed0 fixed 0 fixed0
    1
    0
    b2 : 384 x 2 kbps            (T1/RS422/INF-H0)
    b6 : 512 kbps                   (T1/RS422)
    b7 : 768 kbps                   (T1/RS422)
    b7
    b6b5
    b4 b3 b2 b1 b0
    b0 : 1152 kbps                  (T1/RS422)
    b1 : 1472 kbps                  (T1)Default = 00H +126H00
    0
    0
    b2 : 1536 kbps                  (T1/RS422)
    b3 : 1920 kbps                  (RS422)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H +127H 
    						
    							Page 4 of 4 NECA 340-414-220 Revision 2.0
    SPR-040 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-041
    VIDEO MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY:
    Specify whether video mode is set or not.
    STEP PROCEDURE 
    Note:
    Use the factory shipment value (08H 00H
    ) in setting the video mode as a general rule.  If 
    change is necessary for any reason, follow the steps described below.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address128H 
    and 129H
    [1] Addresses (hexadecimal values) in setting the video mode.
    The video mode is set in hexadecimal values by dividing the 16  bits (b0 to b15) into 
    the upper-half and lower-half 8 bits, or specifically by setting bit 3 in the lower-half 
    8 bits to “1” or “0”.  Accordingly, since the upper-half 8 bits are always “00H”, set 
    only the lower-half 8 bits (address 128H).
    ADDRESS VIDEO MODE
    128H  Lower-half 8 bits setting address (b0 to b7)
    129H Upper-half 8 bits setting address (b8 to b15)
    xi:System parameter values See  below:
    [1] System parameter values on setting the video mode for the addresses.
    The factory shipment value for the system parameter is 
    08H 00H
    .
    SYSTEM PARAMETER 
    VIDEO MODE
    ADDRESS
    129HADDRESS
    128H
    00H 00H OFF
    00H 08H ON (H.261 video) 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-041 MCU 5000A Multipoint Control Unit
    VIDEO MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						