NECA 340-414-100 Revision 2.0Page 79 MCU 5000A Multipoint Control Unit General Description Manual Figure 7-9: Loopback Points RELAY IPAF MTSC MTSC MTSCMTSC PN CHECKER PN GENERATOR POINT A POINT B POINT C POINT D POINT E POINT F1.5M LIF UNIT EC H221 MUX UNIT V SW/LSD UNIT HSCX A CODEC POINT H POINT G RELAY MTSC MTSC MTSCMTSC PN CHECKER PN GENERATOR POINT A POINT B POINT C POINT D POINT FRS-422 LIF UNIT EC H221 MUX UNIT V SW/LSD UNIT HSCX A CODEC POINT H POINT G (a) 1.5M LIF Loopback Points (b) RS-422 LIF Loopback Points
Page 80NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit 7.44 The loopback point setting, the loopback test and loopback release mentioned above are conducted by the execution of the MCU console commands. To conduct loopback test, it is necessary to set. However, the console loopback test does not require the loopback point setting because it automatically sets loopback points. G: Self Diagnostic Function7.45 When power switch is turn-on, the self-diagnostic for the following hardware is performed. • RAM test: Read/write test of RAM area is executed. If any error is detected, the program activity is stopped. • ROM test: The matching of the check sum and programed value is verified. If any error detected, the program activity is stopped. • Hardware initializing test: When initializing the hardware with program, the normal initializing operation is verified. If any error is detected, the critical error cause to stop the program activity, the minor error indicates the alarm on the console. • Unit installation test: Unit installation state is verified. When any necessary unit is not installed, the alarm is indicated on the console. • System parameter back-up test: CRC in the system parameter area is verified. When any error is recognized, and then the program activity is stopped.
NECA 340-414-100 Revision 2.0Page 81 MCU 5000A Multipoint Control Unit General Description Manual 8: MCU CONSOLE 8.01 The MCU console provides the functions of the system parameter and teleconference setting, the memory card control, and the maintenance with MCU console as equipment controller. The MCU console provides operator management/video switch control which is operated by teleconference terminal TC5000 with optional software. Refer to NECA 340-414-300. A: Console 8.02 The MCU console consists personal computer, which is connectable to the RS-232C serial interface. The MCU console provides various functions by entering console command. B: Console Command 8.03 Table 8-1 lists all of the console commands provided. Table 8-1: Console Command List (1 of 4) COMMAND CATEGORY COMMAND FUNCTION System Setting MonitorCGPR Creates auto start command generator program. LCKS Displays synchronization clock source for line. LCNQ Displays type of LIF unit mounted and its bit rate. LECR Resets error counter for physical line. LERQ Displays number of error occurrence on physical line. LSTQ Displays each physical line status. RCGP Retrieves (reads) and displays auto start command generator program. Switching ControlBCON Makes both direction connections between two terminals. BDSC Disconnects both direction connections between two terminals. LCONConnects one transmit terminal to specified receive terminals and simultaneously causes transmit terminal to monitor (receive) picture sent from one specified terminal. LDSC Disconnects multiple connections. SDSC Disconnects all connections in the system. RCNN Retrieves and displays connection status on all transmission lines in use. UCON Broadcasts one picture for all specified terminals. UDSC Disconnects broadcast connection. Multipoint/Lecture Connection ControlECON Makes multipoint connections for education mode. EDSC Disconnects multipoint connections for education mode. MCNR Sets local terminal to waiting status for cascade connection by master MCU. MCON Makes multipoint connections. MDCR Releases cascade connection status or cascade connection waiting status. MDSC Disconnects multipoint connections. RATT Displays current status of multi-connected terminals in the system. RRNMRetrieves and displays logic line numbers, logic room numbers, and port numbers for multi-connected terminals.
Page 82NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit Table 8-1: Console Command List (2 of 4) COMMAND CATEGORY COMMAND FUNCTION Multipoint Teleconference ControlALRM Sends or stops alarm tone to all teleconference terminals (rooms). COPRAssigns or cancels operator privilege of specified teleconference room (terminal). CSPR Broadcasts picture of specified terminal. CRPR Connects or disconnects between transmit and receive terminals. CVCR Controls voice (talker) detect function of specified terminal. CMPRChanges monitor picture on display from broadcasting terminal to the picture from specified terminal. CSRR Displays status concerning specified terminal. CMSG Displays message into the terminal taking part in multipoint conference. GRRC Sends global indication to all MCU consoles. EQUR Requests question/speech from specified lectured terminal to instructor terminal. EQRCCancels request of question/speech from specified lectured terminal to instructor terminal. ETLKLimits talk to one (specified) terminal with in a multipoint teleconference session. RCAPRetrieves and displays capability parameter values of specified multi-connected terminal. RMOD Retrieves and displays transmit modes of specified terminal. STPR Broadcasts still pictures of specified terminal. Multipoint Teleconference Terminal ControlSNAM Registers or deletes area name of multi-connected terminal. RNAM Retrieves and displays area name of multi-connected terminal. Memory Card ControlCPMC Copies data from source memory card to target memory card. RDIR Retrieves and displays file directory in memory card. RMCS Displays status and type of memory card. RMCV Displays software version of memory card. H.243 Multipoint Connection ControlRCON Makes multipoint connections (H.243 mode) RDSC Disconnects multipoint connections. (H.243 mode) RADD Adds multipoint connections to RCON conference. RDRP Drops multipoint connections from RCON conference. RASNIndicates relation between conference room number and terminal number assigned by RCON. RRATAcquire conference participation of terminal for specific conference room group RCON. RCNQ Indicate connection situation of multipoint conference, setup by RCON.
NECA 340-414-100 Revision 2.0Page 83 MCU 5000A Multipoint Control Unit General Description Manual Table 8-1: Console Command List (3 of 4) ISDN ControlNCRNSend a call of ISDN line. In case of 2xB, two lines are connected at one time for the call. In case of 2xB and multipoint (when H.242 on) second call will be processed after the first H.242 negotiation sequence. NDSC Disconnect ISDN line. In case of 2xB, disconnect twice. NCICWhen reception report is manual reception received by NINC indication, specify whether to accept this reception. NIWT Set up to wait for reception to receive wait for ISDN line. NIWQ Indicate the logical line in ready receive status line numbers (none a, s, c). NIWR Release reception wait. INET ON/OFF indication report related to ISDN. NSTQ Display transmission status of ISDN line (complete the digit). NLGC Delete communicate history. NPDS Register speed dial. NPDRDisplay register contents of speed dial (complete the digit. When parameter was omitted, display all registered contents. NDSS Register local address. NDSRDisplay the registered local number (complete the digit). When omitted, display all registered lines. NLGQDisplay the maximum of 100 transmission history (complete the digit). When omitted, indicate all history. When the specified number exceeds the number of accumulate, display all history. System Setting and MaintenanceISPR Initialize system parameter RCLK Read system clock RLCS Remote loop command send RROM Read ROM version RRST Request system reset RSPR Read system parameter RTLP Release loopback test SSPR Set system parameter STLP Set for test of loopback SVSP Save system parameter TLOP Test of loopback WCLK Write system clock
Page 84NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit Table 8-1: Console Command List (4 of 4) COMMAND CATEGORY COMMAND FUNCTION Global IndicationCJNIIndicates notifies that teleconference terminal is connected to the control terminal unit CMPI Indicates notifies that the picture of the broadcasting terminal has been changed COPI Indicates modifies the assignment or cancellation of the operator privilege CRPI Indicates notifies one transmitting terminal and one receive terminal CSPI Indicates notifies that a terminal is broadcasting CSTI Indicates notifies that the status of a terminal is changed CVCI Indicates notifies that a terminal is detecting a voice EQCI Indicates notifies that the question request EQRI Indicates notifies that a lectured terminal is asking ERRI Indicates notifies that the status ETKI Indicates notifies that the talk the specified terminal is permitted MCNI Indicates notifies that cascade connection is established MDCI Indicates notifies that cascade connection is disconnected RLCI Indicates notifies that a terminal requests STEI Indicates notifies that the still picture of the terminal is broadcasting
NECA 340-414-100 Revision 2.0Page 85 MCU 5000A Multipoint Control Unit General Description Manual 9: SYSTEM PARAMETER A: Application 9.01 The MCU 5000A provides the system parameters in accordance with various operation of the teleconference system. The system can be customized with user requirement condition. Refer to NECA 340-414-220. B: System Parameter 9.02 The main system parameter and the descriptions are shown in Table 9-1. Table 9-1: System Parameter Setting NO. SYSTEM PARAMETER FUNCTION 1Line rate Sets the connecting line bit rate. 2Frame Format Sets the Frame Format used in the connecting line. (T1 only) 3Line Code Sets the Line Code used in the connecting line. (T1 only) 4RAI type Sets the receiving RAI type. (T1 only) 5Clock Source Sets the Clock Source (line/internal) 6Line Equalizer Sets the Line Equalizer with port unit. (T1 only) 7Video signal switching timer Sets the standard level as the communication rate. 8Transfer Rate Capability Sets the transfer rate as the communication rate. 9Network Classification Capability Sets the network controlled or not controlled 10Audio Mode Sets the connected terminal voice capability. 11Network Classification Mode Sets the network controlled or not controlled
Page 86NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-210 ISSUE 2 DOI-G05184 PART OF STOCK # 0293922 INSTALLATION MANUAL SEPTEMBER, 1998 NEC America, Inc. MCU 5000A MULTIPOINT CONTROL UNIT
LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its em- ployees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. Copyright 1998 NEC America, Inc. Printed in USA