    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-042
    LOW SPEED DATA (LSD) MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY:
    Set  the Low Speed Data (LSD) mode.
    STEP PROCEDURE 
    1Note:
    MCU 5000A does not support LSD mode.  Be sure, therefore, to set all LSD mode settings to 
    OFF (0000H)
    .  If change is necessary for any reason, follow the steps described below.
    Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address12AH 
    and 12BH
    [1] Addresses (hexadecimal values) on setting the LSD mode.
    The LSD mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into 
    the upper-half and lower-half 8 bits.
    ADDRESS  LSD  MODE
    12AH Lower-half 8 bits setting address (b0 to b7)
    12BH Upper-half 8 bits setting address (b8 to b15)
    xi:
    System parameter values See  below:
    [1] System parameter values on setting the LSD mode for the addresses.
    The factory shipment value for the system parameter is 00H 00H
    . 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-042 MCU 5000A Multipoint Control Unit
    LOW SPEED DATA (LSD) MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETER
    LSD  MODE SETTING
    ADDRESS
    12BHADDRESS
    12AH
    00H 00H OFF
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-043
    HIGH SPEED DATA (HSD) MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY: 
    Set  the High Speed Data (HSD) mode. 
    STEP PROCEDURE 
    Note:
    MCU 5000A does not support HSD in MCON mode.
    1 Enter the following command.
    SSPR__ n
    1 =  x1 __n2 = x2 __ … ni = xi … ¿
    n
    i:
    System parameter address12CH 
    and 12DH
    [1] Addresses (hexadecimal values) on setting the HSD mode.
    The HSD mode is set in hexadecimal values by  dividing the 32 bits (b0 to b31) into 
    the four-quarter 8 bits.
    ADDRESS HSD (HIGH SPEED DATA) MODE
    12CH Fourth-quarter 8 bits setting address (b0 to b7)
    12DH Third-quarter 8 bits setting address (b8 to b15)
    12EH Second-quarter 8 bits setting address (b16 to b23)
    12FH First-quarter 8 bits setting address (b24 to b31)
    xi:
    System parameter values See  below:
    [1] System parameter values on setting the HSD mode for the addresses.
    The factory shipment value for the system parameter is 00H 00H 00H 00H
    . 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-043 MCU 5000A Multipoint Control Unit
    HIGH SPEED DATA (HSD) MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETER
    HSD  MODE SETTING
    ADDRESS
    12FHADDRESS
    12EHADDRESS
    12DHADDRESS
    12CH
    00H 00H 00H 00H OFF
    00H 00H 02H 00H 64 kb/s is ON.
    00H 00H 04H 00H 128 kb/s is ON.
    00H 00H 08H 00H 192 kb/s is ON.
    00H 00H 10H 00H 256 kb/s is ON.
    00H 00H 20H 00H 320 kb/s is ON
    00H 00H 40H 00H 384 kb/s is ON.
    00H 00H 80H 00H 512 kb/s (R) is ON.
    00H 01H 00H 00H 768 kb/s (R) is ON.
    00H 02H 00H 00H 1152 kb/s (R) is ON.
    00H 04H 00H 00H 1536 kb/s (r) is ON.
    In all cases, all H-MLPs are OFF.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-4 14- 22 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   SPR-044
    MLP MODE SETTING
    ADDRESS  MLP MODE
    x 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-044 MCU 5000A Multipoint Control Unit
    MLP MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETER
    MLP MODE SETTING
    ADDRESS
    131HADDRESS
    130H
    00H 00H OFF
    00H 02H MLP-4K is ON.
    00H 04H MLP-6.4K is ON.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-4 14- 22 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   SPR-045
    NETWORK CLASSIFIC ATION MODE SETTING
    ADDRESS   NETWORK CLASSIFICAT IO N  MODE
    x 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-045 MCU 5000A Multipoint Control Unit
    NETWORK CLASSIFICATION MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-047
    MBE MODE SETTING
    TERMINAL MODE RELATED
    SUMMARY: 
    MCU 5000A uses MBE command to utilize NECs original expansion devices.
    STEP PROCEDURE 
    Note:
    Set the MBE mode to ON (01H 00H)
     as a general rule.  If change is necessary for any reason, 
    follow the steps described below.
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address136H 
    and 137H
    [1] Addresses (hexadecimal values) in setting the MBE mode.
    The MBE mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into 
    the upper-half and lower-half 8 bits, or specifically by setting bit 0 in the lower-half 
    8 bits to “1” or “0”.  Accordingly, since the upper-half 8 bits are always “00H”, set 
    only the lower-half 8 bits (address 136H).
    ADDRESS MBE MODE
    136H  Lower-half 8 bits setting address (b0 to b7)
    137H Upper-half 8 bits setting address (b8 to b15)
    xi:
    System parameter values See  below:
    [1] System parameter values on setting the MBE mode for the addresses.
    The factory shipment value for the system parameter is 01H
     00H
    .
    SYSTEM PARAMETER
    MBE MODE SETTING
    ADDRESS
    137HADDRESS
    136H
    00H 00H OFF
    00H 01H ON 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-047 MCU 5000A Multipoint Control Unit
    MBE MODE SETTING
    TERMINAL MODE RELATED
    STEP PROCEDURE 
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						