NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-042 LOW SPEED DATA (LSD) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set the Low Speed Data (LSD) mode. STEP PROCEDURE 1Note: MCU 5000A does not support LSD mode. Be sure, therefore, to set all LSD mode settings to OFF (0000H) . If change is necessary for any reason, follow the steps described below. Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address12AH and 12BH [1] Addresses (hexadecimal values) on setting the LSD mode. The LSD mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits. ADDRESS LSD MODE 12AH Lower-half 8 bits setting address (b0 to b7) 12BH Upper-half 8 bits setting address (b8 to b15) xi: System parameter values See below: [1] System parameter values on setting the LSD mode for the addresses. The factory shipment value for the system parameter is 00H 00H .
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-042 MCU 5000A Multipoint Control Unit LOW SPEED DATA (LSD) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER LSD MODE SETTING ADDRESS 12BHADDRESS 12AH 00H 00H OFF 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-043 HIGH SPEED DATA (HSD) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set the High Speed Data (HSD) mode. STEP PROCEDURE Note: MCU 5000A does not support HSD in MCON mode. 1 Enter the following command. SSPR__ n 1 = x1 __n2 = x2 __ … ni = xi … ¿ n i: System parameter address12CH and 12DH [1] Addresses (hexadecimal values) on setting the HSD mode. The HSD mode is set in hexadecimal values by dividing the 32 bits (b0 to b31) into the four-quarter 8 bits. ADDRESS HSD (HIGH SPEED DATA) MODE 12CH Fourth-quarter 8 bits setting address (b0 to b7) 12DH Third-quarter 8 bits setting address (b8 to b15) 12EH Second-quarter 8 bits setting address (b16 to b23) 12FH First-quarter 8 bits setting address (b24 to b31) xi: System parameter values See below: [1] System parameter values on setting the HSD mode for the addresses. The factory shipment value for the system parameter is 00H 00H 00H 00H .
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-043 MCU 5000A Multipoint Control Unit HIGH SPEED DATA (HSD) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER HSD MODE SETTING ADDRESS 12FHADDRESS 12EHADDRESS 12DHADDRESS 12CH 00H 00H 00H 00H OFF 00H 00H 02H 00H 64 kb/s is ON. 00H 00H 04H 00H 128 kb/s is ON. 00H 00H 08H 00H 192 kb/s is ON. 00H 00H 10H 00H 256 kb/s is ON. 00H 00H 20H 00H 320 kb/s is ON 00H 00H 40H 00H 384 kb/s is ON. 00H 00H 80H 00H 512 kb/s (R) is ON. 00H 01H 00H 00H 768 kb/s (R) is ON. 00H 02H 00H 00H 1152 kb/s (R) is ON. 00H 04H 00H 00H 1536 kb/s (r) is ON. In all cases, all H-MLPs are OFF. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-4 14- 22 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit SPR-044 MLP MODE SETTING ADDRESS MLP MODE x
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-044 MCU 5000A Multipoint Control Unit MLP MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER MLP MODE SETTING ADDRESS 131HADDRESS 130H 00H 00H OFF 00H 02H MLP-4K is ON. 00H 04H MLP-6.4K is ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-4 14- 22 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit SPR-045 NETWORK CLASSIFIC ATION MODE SETTING ADDRESS NETWORK CLASSIFICAT IO N MODE x
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-045 MCU 5000A Multipoint Control Unit NETWORK CLASSIFICATION MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-047 MBE MODE SETTING TERMINAL MODE RELATED SUMMARY: MCU 5000A uses MBE command to utilize NECs original expansion devices. STEP PROCEDURE Note: Set the MBE mode to ON (01H 00H) as a general rule. If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address136H and 137H [1] Addresses (hexadecimal values) in setting the MBE mode. The MBE mode is set in hexadecimal values by dividing the 16 bits (b0 to b15) into the upper-half and lower-half 8 bits, or specifically by setting bit 0 in the lower-half 8 bits to “1” or “0”. Accordingly, since the upper-half 8 bits are always “00H”, set only the lower-half 8 bits (address 136H). ADDRESS MBE MODE 136H Lower-half 8 bits setting address (b0 to b7) 137H Upper-half 8 bits setting address (b8 to b15) xi: System parameter values See below: [1] System parameter values on setting the MBE mode for the addresses. The factory shipment value for the system parameter is 01H 00H . SYSTEM PARAMETER MBE MODE SETTING ADDRESS 137HADDRESS 136H 00H 00H OFF 00H 01H ON
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-047 MCU 5000A Multipoint Control Unit MBE MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.