Home > NEC > Communications System > NEC Mcu 5000a Multipoint Control Unit Equipment Manual

NEC Mcu 5000a Multipoint Control Unit Equipment Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 702
    							NECA 340-414-500 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit TCP-022
      TROUBLESHOOTING OF VDSW UNIT
    GENERAL: 
    Sectionalization of failure is performed by the LED indication of VDSW 
    unit.
    APPARATUS: 
    None
    STEP PROCEDURE REFERENCE NO.
    Note 1:
    Location of SWs, Straps, LEDs, and list of LED function 
    are shown in GSD-010
    .
    Note 2:
    These do not indicate failure conditions directly but may 
    be an aid to failure sectionalization.
    Note 3:
    When a failure has happened to the visual communication, 
    perform the troubleshooting checking  LEDs of this unit.
    1 Verify that the PN ERR of VDSW unit is lit.
    If YES
    , go to Step 2
    .
    If NO
    , go to Step 3
    .
    2 When the PN ERR of this unit is lit.
    It lights up when the judgment of abnormality is given as a result of loopback 
    pattern comparison at the time of MCU loop test.
    Then, go to Step 12
    .TCP-004
    3 Check the lighting condition of LEDs on the VDSW unit.
    4 Does CONF A LED light when group A communication is performed?
    (Does CONF B LED light when group B communication is performed?)
    If YES
    , go to Step 6
    .
    If NO
    , go to Step 5
    .
    5 Turn the toggle switch to CONF A =Conference A  (CONF B = conference 
    B), and then verify the state of LED.
    If it is lit, go to Step 7
    .
    If not, go to Step 6
    .
    6 Check the power-up and setup of VL 5000s in the participating conference 
    rooms. 
    						
    							Page 2 of 2 NECA 340-414-500 Revision 2.0
    TCP-022 MCU 5000A Multipoint Control Unit
    TROUBLESHOOTING OF VDSW UNIT
    STEP PROCEDURE
    REFERENCE NO.
    7 Are broadcast sending station LEDs (VIDEO RC1 to 4) lit?
    If YES
    , go to Step 11
    .
    If NO
    , go to Step 8
    .
    8 Request the system operator to send the voice signal from the conference room 
    (send his own voice).
    9 Are broadcast sending station LEDs (VIDEO RC1 to 4) lit?
    If YES
    , go to Step 11
    .
    If NO
    , go to Step 12
    .
    10 This unit operates normally.  Then, go to Step 12
    .
    11 The VDSW unit is faulty. Replace it.