    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-113
    MBE MESSAGE CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    (1) MBE Message 6 (Data Application BAS) Capability (A: +21EH) (B: +27EH)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed 0 fixed
    0 fixed
    0 fixed0 fixed A: +21EH
    B: +27EH0 fixed0 fixed0 fixed
    (2) MBE Message 7 (Data Application BAS) Capability (A: +21FH) (B: +27FH)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed
    0 fixed 0 fixed0 fixed
    0 fixed
    00 fixed A: +21FH
    B: +27FH0 fixed
    b1 : STILL (H.261)
    (3) MBE Message 8 (Data Application BAS) Capability (A: +220H) (B: +280H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed0 fixed
    0 fixed 0 fixed A: +220H
    B: +280H0 fixed
    0 fixed0 fixed
    0 fixed
    (4) MBE Message 9 Capability (A: +221H) (B: +281H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed
    0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixed0 fixed A: +221H
    B: +281H 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-113 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-114
    TIC CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    TIC Capability (A: +222H) (B: +282H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 01H 0 fixed
    0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixedTIC A: +222H
    B: +282H
    1 : ON
    0 : OFF 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-114 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-115
    CIC CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    CIC Capability (A: +223H) (B: +283H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 01H 0 fixed
    0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixedCIC A: +223H
    B: +283H
    1 : ON
    0 : OFF 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-115 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-116
    AUDIO MODE CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    Audio Mode (A: +230H ~ +233H) (B: +290H ~ +293H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 20H 0 fixed010 00 A: +230H
    B: +290H
    b2 : m-law, OU
    b3 : m-law,OF (f7)
    b4 : G.722 Mode 1
    b5 : G.722 Mode 2
    b6 : G.722 Mode 30 fixed
    0 fixed
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0 fixed
    0 fixed
    0 fixed0 fixed 0 fixed
    0 fixed
    0 fixed0 fixed A: +231H
    B: +291H
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 00 fixed 0 fixed A: +232H
    B: +292H
    b2 : m-law, OU0 fixed
    0 fixed 0 fixed 0 fixed 0 fixed
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 0
    0 A: +233H
    B: +293H
    b6 : Audio OFF, U
    b7 : Audio OFF, F0 fixed
    0 fixed 0 fixed 0 fixed 0 fixed0 fixed 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-116 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-117
    TRANSFER RATE CAPABILITY SETTING
    TERMINAL CAPABILITY RELATED
    Transfer Rate Mode (A: +234H ~ +237H) (B: +294H ~ +297H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 20H 0 fixed
    0 A: +234H
    B: +294H
    b0 : 64 kbps          (T1/RS422/INS)
    b1 : 64 x 2 kbps    (RS422/INS)
    b6 : 128 kbps         (T1/RS422)
    b7 : 192 kbps         (T1/RS422)0 fixed
    0 fixed0 fixed
    00
    0
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 02H 0 fixed 010 A: +235H
    B: +295H
    b0 : 256 kbps             (T1/RS422/INS)
    b1 : 384 kbps             (T1/RS422/INS-H0)
    b2 : 384 x 2 kbps       (RS422/INS-H0)
    b6 : 512 kbps              (T1/RS422)0 fixed0 fixed
    0 0
    b7 : 768 kbps              (T1/RS422)
    Note:  For 2H0, b2 will be 1.
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H 000 A: +236H
    B: +296H0
    b0 : 1152 kbps       (T1/RS422)
    b1 : 1472kbps        (T1)
    b2 : 1536 kbps       (T1/RS422)
    b3 : 1920 kbps       (RS422)0 fixed 0 fixed 0 fixed 0 fixed
    b7
    b6b5
    b4 b3 b2 b1 b0
    Default = 00H A: +237H
    B: +297H0 fixed
    0 fixed
    0 fixed0 fixed
    0 fixed
    0 fixed 0 fixed 0 fixed 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0