NEC Mcu 5000a Multipoint Control Unit Equipment Manual
Have a look at the manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NECA 340-414-220 Revision 2.0 Page 1 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SUMMARY: Specifies the line from which to extract the line clock to be used inside the MCU 5000A. When set to “auto”, the line whose line signal is the first to turn normal will be specified as the clock source, but it will be replaced by the lowest- numbered line currently in normal operation once the line acting as the clock source then ceases being normal. When all the terminals are connected via network, use the MCU 5000A on this setting. STEP PROCEDURE Note: If the physical line number is set with any value from “01H” to “10H”, the line will be fixed as the clock source. In this case, care must be taken because an abnormal state of the line would lose the clock source and also cause the other lines to lose synchronization. If the MCU 5000A is connected to some terminals directly and to others via network, be sure to use the line connected via network as the clock source. When set to “internal”, the intra-MCU crystal oscillator clock will supply the line clock. If MCU 5000A must be connected directly to all the terminals without going through network, use the MCU 5000A with this “internal” setting on. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address3BH to 3DH The addresses for setting the clock source and clock mask are as shown in the following table. ADDRESS MEANING 3BH Clock source setting 3CH Clock source masking for lines 1 through 8 3DH Clock source masking for lines 9 through 16 xi: System parameter valuesSee below: [1] System parameter values on setting the clock source for the address 3BH. The factory shipment value for the system parameter is 00H.
Page 2 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED STEP PROCEDURE SYSTEM PARAMETER CLOCK SOURCE (CH) SYSTEM PARAMETER CLOCK SOURCE (CH) 00H Automatic (automatic selection of line in its numerical order)09H 9 01H 1 0AH 10 02H 2 0BH 11 03H 3 0CH 12 04H 4 0DH 13 05H 5 0EH 14 06H 6 0FH 15 07H 7 10H 16 08H 8 80H Internal [2] System parameter values on setting the clock source mask for the addresses 3CH and 3DH. The factory shipment value is 0000H . Valid only when setting the clock source, with the masked lines being so controlled as not to function as the clock source. See tables on the following pages. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 3 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED Note: Marking a line as masked omits it from automatic selection if 3B = 00 SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0000H No lines masked 0201H Lines 1&10 are masked 0001H Line 1 is masked 0401H Lines 1&11 are masked 0002H Line 2 is masked 0801H Lines 1&12 are masked 0004H Line 3 is masked 1001H Lines 1&13 are masked 0008H Line 4 is masked 2001H Lines 1&14 are masked 0010H Line 5 is masked 4001H Lines 1&15 are masked 0020H Line 6 is masked 8001H Lines 1&16 are masked 0040H Line 7 is masked 0006H Lines 2&3 are masked 0080H Line 8 is masked 000AH Lines 2&4 are masked 0100H Line 9 is masked 0012H Lines 2&5 are masked 0200H Line 10 is masked 0022H Lines 2&6 are masked 0400H Line 11 is masked 0042H Lines 2&7 are masked 0800H Line 12 is masked 0082H Lines 2&8 are masked 1000H Line 13 is masked 0102H Lines 2&9 are masked 2000H Line 14 is masked 0202H Lines 2&10 are masked 4000H Line 15 is masked 0402H Lines 2&11 are masked 8000H Line 16 is masked 0802H Lines 2&12 are masked 0003H Lines 1&2 are masked 1002H Lines 2&13 are masked 0005H Lines 1&3 are masked 2002H Lines 2&14 are masked 0009H Lines 1&4 are masked 4002H Lines 2&15 are masked 0011H Lines 1&5 are masked 8002H Lines 2&16 are masked 0021H Lines 1&6 are masked 000CH Lines 3&4 are masked 0041H Lines 1&7 are masked 0014H Lines 3&5 are masked 0081H Lines 1&8 are masked 0024H Lines 3&6 are masked 0101H Lines 1&9 are masked 0044H Lines 3&7 are masked
Page 4 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0084H Lines 3&8 are masked 0210H Lines 5&10 are masked 0104H Lines 3&9 are masked 0410H Lines 5&11 are masked 0204H Lines 3&10 are masked 0810H Lines 5&12 are masked 0404H Lines 3&11 are masked 1010H Lines 5&13 are masked 0804H Lines 3&12 are masked 2010H Lines 5&14 are masked 1004H Lines 3&13 are masked 4010H Lines 5&15 are masked 2004H Lines 3&14 are masked 8010H Lines 5&16 are masked 4004H Lines 3&15 are masked 0060H Lines 6&7 are masked 8004H Lines 3&16 are masked 00A0H Lines 6&8 are masked 0018H Lines 4&5 are masked 0120H Lines 6&9 are masked 0028H Lines 4&6 are masked 0220H Lines 6&10 are masked 0048H Lines 4&7 are masked 0420H Lines 6&11 are masked 0088H Lines 4&8 are masked 0820H Lines 6&12 are masked 0108H Lines 4&9 are masked 1020H Lines 6&13 are masked 0208H Lines 4&10 are masked 2020H Lines 6&14 are masked 0408H Lines 4&11 are masked 4020H Lines 6&15 are masked 0808H Lines 4&12 are masked 8020H Lines 6&16 are masked 1008H Lines 4&13 are masked 00C0H Lines 7&8 are masked 2008H Lines 4&14 are masked 0140H Lines 7&9 are masked 4008H Lines 4&15 are masked 0240H Lines 7&10 are masked 8008H Lines 4&16 are masked 0440H Lines 7&11 are masked 0030H Lines 5&6 are masked 0840H Lines 7&12 are masked 0050H Lines 5&7 are masked 1040H Lines 7&13 are masked 0090H Lines 5&8 are masked 2040H Lines 7&14 are masked 0110H Lines 5&9 are masked 4040H Lines 7&15 are masked
NECA 340-414-220 Revision 2.0 Page 5 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 8040H Lines 7&16 are masked 4400H Lines 11&15 are masked 0180H Lines 8&9 are masked 8400H Lines 11&16 are masked 1280H Lines 8&10 are masked 1800H Lines 12&13 are masked 0480H Lines 8&11 are masked 2800H Lines 12&14 are masked 0880H Lines 8&12 are masked 4800H Lines 12&15 are masked 1080H Lines 8&13 are masked 8800H Lines 12&16 are masked 2080H Lines 8&14 are masked 3000H Lines 13&14 are masked 4080H Lines 8&15 are masked 5000H Lines 13&15 are masked 8080H Lines 8&16 are masked 9000H Lines 13&16 are masked 0300H Lines 9&10 are masked 6000H Lines 14&15 are masked 0500H Lines 9&11 are masked A000H Lines 14&16 are masked 0900H Lines 9&12 are masked C000H Lines 15&16 are masked 1100H Lines 9&13 are masked 0070H Lines 1,2&3 are masked 2100H Lines 9&14 are masked 00B0H Lines 1,2&4 are masked 4100H Lines 9&15 are masked 0013H Lines 1,2&5 are masked 8100H Lines 9&16 are masked 0023H Lines 1,2&6 are masked 0600H Lines 10&11 are masked 0043H Lines 1,2&7 are masked 0A00H Lines 10&12 are masked 0083H Lines 1,2&8 are masked 1200H Lines 10&13 are masked 0103H Lines 1,2&9 are masked 2200H Lines 10&14 are masked 0203H Lines 1,2&10 are masked 4200H Lines 10&15 are masked 0403H Lines 1,2&11 are masked 8200H Lines 10&16 are masked 0803H Lines 1,2&12 are masked 0C00H Lines 11&12 are masked 1003H Lines 1,2&13 are masked 1400H Lines 11&13 are masked 2003H Lines 1,2&14 are masked 2400H Lines 11&14 are masked 4003H Lines 1,2&15 are masked
Page 6 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 8003H Lines 1,2&16 are masked 8009H Lines 1,4&16 are masked 00D0H Lines 1,3&4 are masked 0031H Lines 1,5&6 are masked 0015H Lines 1,3&5 are masked 0051H Lines 1,5&7 are masked 0025H Lines 1,3&6 are masked 0091H Lines 1,5&8 are masked 0045H Lines 1,3&7 are masked 0111H Lines 1,5&9 are masked 0085H Lines 1,3&8 are masked 0211H Lines 1,5&10 are masked 0105H Lines 1,3&9 are masked 0411H Lines 1,5&11 are masked 0205H Lines 1,3&10 are masked 0811H Lines 1,5&12 are masked 0405H Lines 1,3&11 are masked 1011H Lines 1,5&13 are masked 0805H Lines 1,3&12 are masked 2011H Lines 1,5&14 are masked 1005H Lines 1,3&13 are masked 4011H Lines 1,5&15 are masked 2005H Lines 1,3&14 are masked 8011H Lines 1,5&16 are masked 4005H Lines 1,3&15 are masked 0061H Lines 1,6&7 are masked 8005H Lines 1,3&16 are masked 00E1H Lines 1,6&8 are masked 0019H Lines 1,4&5 are masked 0121H Lines 1,6&9 are masked 0029H Lines 1,4&6 are masked 0221H Lines 1,6&10 are masked 0049H Lines 1,4&7 are masked 0421H Lines 1,6&11 are masked 0089H Lines 1,4&8 are masked 0821H Lines 1,6&12 are masked 0109H Lines 1,4&9 are masked 1021H Lines 1,6&13 are masked 0209H Lines 1,4&10 are masked 2021H Lines 1,6&14 are masked 0409H Lines 1,4&11 are masked 4021H Lines 1,6&15 are masked 0809H Lines 1,4&12 are masked 8021H Lines 1,6&16 are masked 1009H Lines 1,4&13 are masked 00C1H Lines 1,7&8 are masked 2009H Lines 1,4&14 are masked 0141H Lines 1,7&9 are masked 4009H Lines 1,4&15 are masked 0241H Lines 1,7&10 are masked
NECA 340-414-220 Revision 2.0 Page 7 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0441H Lines 1,7&11 are masked 4201H Lines 1,10&15 are masked 0841H Lines 1,7&12 are masked 8201H Lines 1,10&16 are masked 1041H Lines 1,7&13 are masked 0C01H Lines 1,11&12 are masked 2041H Lines 1,7&14 are masked 1401H Lines 1,11&13 are masked 4041H Lines 1,7&15 are masked 2401H Lines 1,11&14 are masked 8041H Lines 1,7&16 are masked 4401H Lines 1,11&15 are masked 0181H Lines 1,8&9 are masked 8401H Lines 1,11&16 are masked 0281H Lines 1,8&10 are masked 1801H Lines 1,12&13 are masked 0481H Lines 1,8&11 are masked 2801H Lines 1,12&14 are masked 0881H Lines 1,8&12 are masked 4801H Lines 1,12&15 are masked 1081H Lines 1,8&13 are masked 8801H Lines 1,12&16 are masked 2081H Lines 1,8&14 are masked 3001H Lines 1,13&14 are masked 4081H Lines 1,8&15 are masked 5001H Lines 1,13&15 are masked 8081H Lines 1,8&16 are masked 9001H Lines 1,13&16 are masked 0301H Lines 1,9&10 are masked 6001H Lines 1,14&15 are masked 0501H Lines 1,9&11 are masked A001H Lines 1,14&16 are masked 0901H Lines 1,9&12 are masked C001H Lines 1,15&16 are masked 1101H Lines 1,9&13 are masked 000FH Lines 1,2,3&4 are masked 2101H Lines 1,9&14 are masked 0017H Lines 1,2,3&5 are masked 4101H Lines 1,9&15 are masked 0027H Lines 1,2,3&6 are masked 8101H Lines 1,9&16 are masked 0047H Lines 1,2,3&7 are masked 0601H Lines 1,10&11 are masked 0087H Lines 1,2,3&8 are masked 0A01H Lines 1,10&12 are masked 0107H Lines 1,2,3&9 are masked 1201H Lines 1,10&13 are masked 0207H Lines 1,2,3&10 are masked 2201H Lines 1,10&14 are masked 0407H Lines 1,2,3&11 are masked
Page 8 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0807H Lines 1,2,3&12 are masked 2013H Lines 1,2,5&14 are masked 1007H Lines 1,2,3&13 are masked 4013H Lines 1,2,5&15 are masked 2007H Lines 1,2,3&14 are masked 8013H Lines 1,2,5&16 are masked 4007H Lines 1,2,3&15 are masked 0063H Lines 1,2,6&7 are masked 8007H Lines 1,2,3&16 are masked 00A3H Lines 1,2,6&8 are masked 001BH Lines 1,2,4&5 are masked 0123H Lines 1,2,6&9 are masked 002BH Lines 1,2,4&6 are masked 0223H Lines 1,2,6&10 are masked 004BH Lines 1,2,4&7 are masked 0423H Lines 1,2,6&11 are masked 008BH Lines 1,2,4&8 are masked 0823H Lines 1,2,6&12 are masked 010BH Lines 1,2,4&9 are masked 1023H Lines 1,2,6&13 are masked 020BH Lines 1,2,4&10 are masked 2023H Lines 1,2,6&14 are masked 040BH Lines 1,2,4&11 are masked 4023H Lines 1,2,6&15 are masked 080BH Lines 1,2,4&12 are masked 8023H Lines 1,2,6&16 are masked 100BH Lines 1,2,4&13 are masked 00C3H Lines 1,2,7&8 are masked 200BH Lines 1,2,4&14 are masked 0143H Lines 1,2,7&9 are masked 400BH Lines 1,2,4&15 are masked 0243H Lines 1,2,7&10 are masked 800BH Lines 1,2,4&16 are masked 0183H Lines 1,2,8&9 are masked 0033H Lines 1,2,5&6 are masked 0283H Lines 1,2,8&10 are masked 0053H Lines 1,2,5&7 are masked 0483H Lines 1,2,8&11 are masked 0093H Lines 1,2,5&8 are masked 0883H Lines 1,2,8&12 are masked 0113H Lines 1,2,5&9 are masked 1083H Lines 1,2,8&13 are masked 0213H Lines 1,2,5&10 are masked 2083H Lines 1,2,8&14 are masked 0413H Lines 1,2,5&11 are masked 4083H Lines 1,2,8&15 are masked 0813H Lines 1,2,5&12 are masked 8083H Lines 1,2,8&16 are masked 1013H Lines 1,2,5&13 are masked 0303H Lines 1,2,9&10 are masked
NECA 340-414-220 Revision 2.0 Page 9 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0503H Lines 1,2,9&11 are masked A003H Lines 1,2,14&16 are masked 0903H Lines 1,2,9&12 are masked C003H Lines 1,2,15&16 are masked 1103H Lines 1,2,9&13 are masked 001FH Lines 1,2,3,4&5 are masked 2103H Lines 1,2,9&14 are masked 002FH Lines 1,2,3,4&6 are masked 4103H Lines 1,2,9&15 are masked 004FH Lines 1,2,3,4&7 are masked 8103H Lines 1,2,9&16 are masked 008FH Lines 1,2,3,4&8 are masked 0603H Lines 1,2,10&11 are masked 010FH Lines 1,2,3,4&9 are masked 0A03H Lines 1,2,10&12 are masked 020FH Lines 1,2,3,4&10 are masked 1203H Lines 1,2,10&13 are masked 040FH Lines 1,2,3,4&11 are masked 2203H Lines 1,2,10&14 are masked 080FH Lines 1,2,3,4&12 are masked 4203H Lines 1,2,10&15 are masked 100FH Lines 1,2,3,4&13 are masked 8203H Lines 1,2,10&16 are masked 200FH Lines 1,2,3,4&14 are masked 0C03H Lines 1,2,11&12 are masked 400FH Lines 1,2,3,4&15 are masked 1403H Lines 1,2,11&13 are masked 800FH Lines 1,2,3,4&16 are masked 2403H Lines 1,2,11&14 are masked 0037H Lines 1,2,3,5&6 are masked 4403H Lines 1,2,11&15 are masked 0057H Lines 1,2,3,5&7 are masked 8403H Lines 1,2,11&16 are masked 0097H Lines 1,2,3,5&8 are masked 1803H Lines 1,2,12&13 are masked 0117H Lines 1,2,3,5&9 are masked 2803H Lines 1,2,12&14 are masked 0217H Lines 1,2,3,5&10 are masked 4803H Lines 1,2,12&15 are masked 0417H Lines 1,2,3,5&11 are masked 8803H Lines 1,2,12&16 are masked 0817H Lines 1,2,3,5&12 are masked 3003H Lines 1,2,13&14 are masked 1017H Lines 1,2,3,5&13 are masked 5003H Lines 1,2,13&15 are masked 2017H Lines 1,2,3,5&14 are masked 9003H Lines 1,2,13&16 are masked 4017H Lines 1,2,3,5&15 are masked 6003H Lines 1,2,14&15 are masked 8017H Lines 1,2,3,5&16 are masked
Page 10 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0067H Lines 1,2,3,6&7 are masked 4087H Lines 1,2,3,8&15 are masked 00A7H Lines 1,2,3,6&8 are masked 8087H Lines 1,2,3,8&16 are masked 0127H Lines 1,2,3,6&9 are masked 0307H Lines 1,2,3,9&10 are masked 0227H Lines 1,2,3,6&10 are masked 0507H Lines 1,2,3,9&11 are masked 0427H Lines 1,2,3,6&11 are masked 0907H Lines 1,2,3,9&12 are masked 0827H Lines 1,2,3,6&12 are masked 1107H Lines 1,2,3,9&13 are masked 1027H Lines 1,2,3,6&13 are masked 2107H Lines 1,2,3,9&14 are masked 2027H Lines 1,2,3,6&14 are masked 4107H Lines 1,2,3,9&15 are masked 4027H Lines 1,2,3,6&15 are masked 8107H Lines 1,2,3,9&16 are masked 8027H Lines 1,2,3,6&16 are masked 0607H Lines 1,2,3,10&11 are masked 00C7H Lines 1,2,3,7&8 are masked 0A07H Lines 1,2,3,10&12 are masked 0147H Lines 1,2,3,7&9 are masked 1207H Lines 1,2,3,10&13 are masked 0247H Lines 1,2,3,7&10 are masked 2207H Lines 1,2,3,10&14 are masked 0447H Lines 1,2,3,7&11 are masked 4207H Lines 1,2,3,10&15 are masked 0847H Lines 1,2,3,7&12 are masked 8207H Lines 1,2,3,10&16 are masked 1047H Lines 1,2,3,7&13 are masked 0C07H Lines 1,2,3,11&12 are masked 2047H Lines 1,2,3,7&14 are masked 1407H Lines 1,2,3,11&13 are masked 4047H Lines 1,2,3,7&15 are masked 2407H Lines 1,2,3,11&14 are masked 8047H Lines 1,2,3,7&16 are masked 4407H Lines 1,2,3,11&15 are masked 0187H Lines 1,2,3,8&9 are masked 8407H Lines 1,2,3,11&16 are masked 0287H Lines 1,2,3,8&10 are masked 1807H Lines 1,2,3,12&13 are masked 0487H Lines 1,2,3,8&11 are masked 2807H Lines 1,2,3,12&14 are masked 0887H Lines 1,2,3,8&12 are masked 4807H Lines 1,2,3,12&15 are masked 1087H Lines 1,2,3,8&13 are masked 8807H Lines 1,2,3,12&16 are masked 2087H Lines 1,2,3,8&14 are masked 3007H Lines 1,2,3,13&14 are masked