NEC Mcu 5000a Multipoint Control Unit Equipment Manual
Have a look at the manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NECA 340-4 14- 30 0 Revisio n 2.0 Page 3 o f 8 MCU 5000A Multipoint Control U nit COP-160 CSRR
Page 4 of 8 NECA 340-414-300 Revision 2.0 COP-160 MCU 5000A Multipoint Control Unit CSRR Mutlipoint Teleconference/Lecture Control (continued) STATUS RESPONCE FORMTELECONFERENCE ROOM NUMBER 1234 XXX00000 XXX11000 XXX20100 XXX31100 XXX40010 XXX51010 XXX60110 XXX71110 XXX80001 XXX91001 XXXA0101 XXXB1101 XXXC0011 XXXD1011 XXXE0111 XXXF1111 X=0 or 1 Note:These room numbers are available in master connection only or slave connection.
NECA 340-414-300 Revision 2.0 Page 5 of 8 MCU 5000A Multipoint Control Unit COP-160 CSRR Mutlipoint Teleconference/Lecture Control (continued) STATUS RESPONCE FORMTELECONFERENCE ROOM NUMBER 5678 XX0X 0000 XX1X 1000 XX2X 0100 XX3X 1100 XX4X 0010 XX5X 1010 XX6X 0110 XX7X 1110 XX8X 0001 XX9X 1001 XXAX0101 XXBX 1101 XXCX 0011 XXDX1011 XXEX 0111 XXFX 1111 X=0 or 1 Note:These room numbers are available in master connection only or slave connection.
Page 6 of 8 NECA 340-414-300 Revision 2.0 COP-160 MCU 5000A Multipoint Control Unit CSRR Mutlipoint Teleconference/Lecture Control (continued) STATUS RESPONCE FORMTELECONFERENCE ROOM NUMBER 9 101112 X0XX 0000 X1XX 1000 X2XX 0100 X3XX 1100 X4XX 0010 X5XX 1010 X6XX 0110 X7XX 1110 X8XX 0001 X9XX 1001 XAXX0101 XBXX 1101 XCXX 0011 XDXX1011 XEXX 0111 XFXX 1111 X=0 or 1 Note:These room numbers are available in master connection only or slave connection. STATUS RESPONCE FORMTELECONFERENCE ROOM NUMBER 13 14 0XXX 0 0 1XXX 1 0 2XXX 0 1 3XXX 1 1 X=0 or 1 Note:These room numbers are available in slave connection.
NECA 340-414-300 Revision 2.0 Page 7 of 8 MCU 5000A Multipoint Control Unit COP-160 CSRR Mutlipoint Teleconference/Lecture Control (continued) RESPONSE FORMATRCON mode g r abcde fff hhh jjj kkk ll mmm nnn oo ppp qqq rrr OK EXPLANATION OF INPUT PARAMETER a ~ e indicate operator status of specific conference room a = Participation status 1: Participation 0: No participation b = Conference terminal 1: Connection 0: No connection c = Voice detection function 1: Valid 0: Invalid d = Permission or speech status 1: Permit 0: Prohibit e = Request for speech status 1: Request 0: No request In fff ~ rrr, information which concern specific conference room will be indicated. fff = Conference room number (00 ~ 252) with operating authority. When 00, there is no operator. hhh = Conference room number (01 ~ 252) of transmission source. jjj = Conference room number (01 ~ 252) which is received by the terminal of transmission source. kkk = Conference room number (01 ~ 252) of original broadcasting source. lll = Conference room number (01 ~ 252) which is received by the terminal of original broadcasting source. mmm = Conference room number (01 ~ 252) of send picture of its own. nnn = Conference room number (01 ~ 252) received by sending terminal when receiving specific picture. ooo = Conference room number (01 ~ 252) of original received by terminal when receiving specific picture. ppp = Conference room number (01 ~ 252) of original specific broadcast terminal. qqq = Conference room number (01 ~ 252) of original LSD transmission. rrr = Conference room number (01 ~ 252) of original HSD transmission.
Page 8 of 8 NECA 340-414-300 Revision 2.0 COP-160 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-4 14- 30 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit COP-161 CMSG
Page 2 of 2 NECA 340-414-300 Revision 2.0 COP-161 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-4 14- 30 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit COP-162 SNAM
Page 2 of 2 NECA 340-414-300 Revision 2.0 COP-162 MCU 5000A Multipoint Control Unit This page is for your notes.