    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 5 o f 6
    MCU  5000A Multipoint Control  U nit   COP-178
    STLP
      y    ______________pp__ ____ 
    						
    							Page 6 of 6 NECA 340-414-300 Revision 2.0
    COP-178 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 1 o f 4
    MCU  5000A Multipoint Control  U nit   COP-179
    TLOP 
    						
    							Page 2 of 4 NECA 340-414-300 Revision 2.0
    COP-179 MCU 5000A Multipoint Control Unit
    TLOP
    System Setting and Maintenance
    (continued)
    (2) For x=L
    p
    1=1 ~ 8
    Specifies a teleconference port number to be tested.  Valid 
    values for p
    1 are:  1 through 8
    p
    2:  not used
    p
    3:  not used
    p
    4:  not used
    (3) For X= A
    p
    1=1 ~ 8
    Specifies a teleconference port number to be tested.  Valid 
    values for p
    1 are:  1 through 8
    p
    2= L, R, C, I, or S
    Specifies the audio test signal condition.  Valid values for p
    2 
    are:
    L:  The returned audio test signal level is measured when test 
    signal is outputted to the specified port for 500ms.
    R:  The audio signal level is measured.
    C:  The continuous audio test signal is outputted (TONE 1).
    I:  The continuous audio test signal is outputted (TONE 2).
    S:  The audio test signal is stopped outputting.
     
    p
    3= 0, 1, 2, or 3
    Specifies the output level of test signal generated by the 
    Pattern Generator.  Valid values for p
    3 are:
    0:  0 dBm0
    1:  -12 dBm0
    2:  -24 dBm0
    3:  -36 dBm0
    p
    4= 0, 1, 2, or 3
    Specifies a frequency of test signal.  Valid values for p
    4 are:
    0:  500 Hz
    1:  800 Hz
    2:  1000 Hz
    3:  1600 Hz 
    						
    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 3 o f 4
    MCU  5000A Multipoint Control  U nit   COP-179
    TLOP 
    						
    							Page 4 of 4 NECA 340-414-300 Revision 2.0
    COP-179 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   COP-180
    RTLP 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-180 MCU 5000A Multipoint Control Unit
     This page is for your notes. 
    						
    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   COP-181
    RROM 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-181 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						