NECA 340-414-220 Revision 2.0 Page 17 of 18 MCU 5000A Multipoint Control Unit SPR-014 RS 422 LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 1BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are masked 2BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are masked 4BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&15 are masked 8BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&16 are maskedA7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&16 are masked 33FFH Lines 1,2,3,4,5,6,7,8,9,10,13&14 are maskedC7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,15&16 are masked 53FFH Lines 1,2,3,4,5,6,7,8,9,10,13&15 are masked3FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&14 are masked 93FFH Lines 1,2,3,4,5,6,7,8,9,10,13&16 are masked5FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&15 are masked 63FFH Lines 1,2,3,4,5,6,7,8,9,10,14&15 are masked9FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&16 are masked A3FFH Lines 1,2,3,4,5,6,7,8,9,10,14&16 are masked6FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&15 are masked C3FFH Lines 1,2,3,4,5,6,7,8,9,10,15&16 are maskedAFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&16 are masked 1FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&13 are maskedCFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 15&16 are masked 2FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&14 are masked7FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13, 14&15 are masked 4FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&15 are maskedBFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 14&16 are masked 8FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&16 are maskedDFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 15&16 are masked 37FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&14 are maskedFFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 14,15&16 are masked
Page 18 of 18 NECA 340-414-220 Revision 2.0 SPR-014 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit SPR-015 H0-INF LIF LINE RATE SETTING LINE RELATED SUMMARY:Set a per-channel communication rate for the communication channels for the H0 lines to and from the connecting conference terminals. Also set the number of conference terminals (in terms of ports) to be accommodated. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address30H to 37H [1] Addresses (hexadecimal values) on setting H0-INF LIF line rate. ADDRESS MEANING 30H The line rate of LIF1 32H The line rate of LIF2 34H The line rate of LIF3 36H The line rate of LIF4 31H The number of ports for LIF1 33H The number of ports for LIF2 35H The number of ports for LIF3 37H The number of ports for LIF4
Page 2 of 4 NECA 340-414-220 Revision 2.0 SPR-015 MCU 5000A Multipoint Control Unit H0-INF LIF LINE RATE SETTING LINE RELATED STEP PROCEDURE x i: System parameter value See below: [1] System parameter values on setting the line rate for each address (30H, 32H, 34H, 36H). The factory shipment value is 05H . SYSTEM PARAMETER LINE RATE 20H 56 kb/s 30H 56 kb/s×2 00H 64 kb/s 10H 64 kb/s×2 25H 336 kb/s 05H 384 kb/s 15H 384 kb/s x 2 35H 336 kb/s x 2 [2] System parameter values on setting the number of ports for each address (31H, 33H, 35H, 37H). The factory shipment value is 10H. Refer to Tables 1 and 2.
NECA 340-414-220 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit SPR-015 H0-INF LIF LINE RATE SETTING LINE RELATED Table 1: Number of Ports For System Parameter SYSTEM PARAMETERNUMBER OF PORTSSYSTEM PARAMETERNUMBER OF PORTSSYSTEM PARAMETERNUMBER OF PORTS 01H 1 21H 33 41H 65 02H 2 22H 34 42H 66 03H 3 23H 35 43H 67 04H 4 24H 36 44H 68 05H 5 25H 37 45H 69 06H 6 26H 38 46H 70 07H 7 27H 39 47H 71 08H 8 28H 40 48H 72 09H 9 29H 41 49H 73 0AH 10 2AH 42 4AH 74 0BH 11 2BH 43 4BH 75 0CH 12 2CH 44 4CH 76 0DH 13 2DH 45 4DH 77 0EH 14 2EH 46 4EH 78 0FH 15 2FH 47 4FH 79 10H 16 30H 48 50H 80 11H 17 31H 49 51H 81 12H 18 32H 50 52H 82 13H 19 33H 51 53H 83 14H 20 34H 52 54H 84 15H 21 35H 53 55H 85 16H 22 36H 54 56H 86 17H 23 37H 55 57H 87 18H 24 38H 56 58H 88 19H 25 39H 57 59H 89 1AH 26 3AH 58 5AH 90 1BH 27 3BH 59 5BH 91 1CH 28 3CH 60 5CH 92 1DH 29 3DH 61 5DH 93 1EH 30 3EH 62 5EH 94 1FH 31 3FH 63 5FH 95 20H 32 40H 64 60H 96
Page 4 of 4 NECA 340-414-220 Revision 2.0 SPR-015 MCU 5000A Multipoint Control Unit H0-INF LIF LINE RATE SETTING LINE RELATED STEP PROCEDURE LINE RATENUMBER OF PORT (SYSTEM PARAMETER)LINE RATENUMBER OF PORT (SYSTEM PARAMETER)LINE RATENUMBER OF PORT (SYSTEM PARAMETER) T1 (64 kb/s) 96 (60H) T1 (1152 kb/s) 4 (04H) T1 (448 kb/s) 12 (0CH) T1 (128 kb/s) 48 (30H) T1 (1536 kb/s) 4 (04H) T1 (672 kb/s) 8 (08H) T1 (192 kb/s) 32 (20H) T1 (56 kb/s) 96 (60H) T1 (1008 kb/s) 4 (04H) T1 (256 kb/s) 24 (18H) T1 (112 kb/s) 48 (30H) T1 (1344 kb/s) 4 (04H) T1 (384 kb/s) 16 (10H) T1 (168 kb/s) 32 (20H) RS422 4 (04H) T1 (512 kb/s) 12 (0CH) T1 (224 kb/s) 24 (18H) RS422 (2×B) 2 (02H) T1 (768 kb/s) 8 (08H) T1 (336 kb/s) 16 (10H) INS 48 (30H) Valid range of values for system parameter are 00H to FFH. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 1 of 18 MCU 5000A Multipoint Control Unit SPR-016 H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SUMMARY: Specifies the line from which to extract the line clock to be used inside the MCU 5000A. When set to “auto”, the line whose line signal is the first to turn normal will be specified as the clock source, but it will be replaced by the lowest- numbered line currently in normal operation once the line acting as the clock source then ceases being normal. When all the terminals are connected via network, use the MCU 5000A on this setting. STEP PROCEDURE Note: If the physical line number is set with any value from “01H” to “10H”, the line will be fixed as the clock source. In this case, care must be taken because an abnormal state of the line would lose the clock source and also cause the other lines to lose synchronization. If the MCU 5000A is connected to some terminals directly and to others via network, be sure to use the line connected via network as the clock source. When set to “internal”, the intra-MCU crystal oscillator clock will supply the line clock. If MCU 5000A must be connected directly to all the terminals without going through network, use the MCU 5000A with this “internal” setting on. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address3BH to 3DH The addresses for setting the clock source and clock mask are as shown in the following table. ADDRESS MEANING 3BH Clock source setting 3CH Clock source masking for lines 1 through 8 3DH Clock source masking for lines 9 through 16 xi: System parameter values See below: [1] System parameter values on setting the clock source for the address 3BH. The factory shipment value for the system parameter is 00H .
Page 2 of 18 NECA 340-414-220 Revision 2.0 SPR-016 MCU 5000A Multipoint Control Unit H0-INF LIF CLOCK SOURCE SETTING LINE RELATED STEP PROCEDURE SYSTEM PARAMETERCLOCK SOURCE (CH)SYSTEM PARAMETERCLOCK SOURCE (CH) 00H Automatic (automatic selection of line in its numerical order)09H 9 01H 1 0AH 10 02H 2 0BH 11 03H 3 0CH 12 04H 4 0DH 13 05H 5 0EH 14 06H 6 0FH 15 07H 7 10H 16 08H 8 80H N/A [2] System parameter values on setting the clock source mask for the addresses 3CH and 3DH. The factory shipment value is 0000H . Valid only when setting the clock source, with the masked lines being so controlled as not to function as the clock source. See tables on the following pages. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 3 of 18 MCU 5000A Multipoint Control Unit SPR-016 H0-INF LIF CLOCK SOURCE SETTING LINE RELATED Note: Marking a line as masked omits it from automatic selection if 3B = 00 SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0000H No lines masked 0201H Lines 1&10 are masked 0001H Line 1 is masked 0401H Lines 1&11 are masked 0002H Line 2 is masked 0801H Lines 1&12 are masked 0004H Line 3 is masked 1001H Lines 1&13 are masked 0008H Line 4 is masked 2001H Lines 1&14 are masked 0010H Line 5 is masked 4001H Lines 1&15 are masked 0020H Line 6 is masked 8001H Lines 1&16 are masked 0040H Line 7 is masked 0006H Lines 2&3 are masked 0080H Line 8 is masked 000AH Lines 2&4 are masked 0100H Line 9 is masked 0012H Lines 2&5 are masked 0200H Line 10 is masked 0022H Lines 2&6 are masked 0400H Line 11 is masked 0042H Lines 2&7 are masked 0800H Line 12 is masked 0082H Lines 2&8 are masked 1000H Line 13 is masked 0102H Lines 2&9 are masked 2000H Line 14 is masked 0202H Lines 2&10 are masked 4000H Line 15 is masked 0402H Lines 2&11 are masked 8000H Line 16 is masked 0802H Lines 2&12 are masked 0003H Lines 1&2 are masked 1002H Lines 2&13 are masked 0005H Lines 1&3 are masked 2002H Lines 2&14 are masked 0009H Lines 1&4 are masked 4002H Lines 2&15 are masked 0011H Lines 1&5 are masked 8002H Lines 2&16 are masked 0021H Lines 1&6 are masked 000CH Lines 3&4 are masked 0041H Lines 1&7 are masked 0014H Lines 3&5 are masked 0081H Lines 1&8 are masked 0024H Lines 3&6 are masked 0101H Lines 1&9 are masked 0044H Lines 3&7 are masked
Page 4 of 18 NECA 340-414-220 Revision 2.0 SPR-016 MCU 5000A Multipoint Control Unit H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0084H Lines 3&8 are masked 0210H Lines 5&10 are masked 0104H Lines 3&9 are masked 0410H Lines 5&11 are masked 0204H Lines 3&10 are masked 0810H Lines 5&12 are masked 0404H Lines 3&11 are masked 1010H Lines 5&13 are masked 0804H Lines 3&12 are masked 2010H Lines 5&14 are masked 1004H Lines 3&13 are masked 4010H Lines 5&15 are masked 2004H Lines 3&14 are masked 8010H Lines 5&16 are masked 4004H Lines 3&15 are masked 0060H Lines 6&7 are masked 8004H Lines 3&16 are masked 00A0H Lines 6&8 are masked 0018H Lines 4&5 are masked 0120H Lines 6&9 are masked 0028H Lines 4&6 are masked 0220H Lines 6&10 are masked 0048H Lines 4&7 are masked 0420H Lines 6&11 are masked 0088H Lines 4&8 are masked 0820H Lines 6&12 are masked 0108H Lines 4&9 are masked 1020H Lines 6&13 are masked 0208H Lines 4&10 are masked 2020H Lines 6&14 are masked 0408H Lines 4&11 are masked 4020H Lines 6&15 are masked 0808H Lines 4&12 are masked 8020H Lines 6&16 are masked 1008H Lines 4&13 are masked 00C0H Lines 7&8 are masked 2008H Lines 4&14 are masked 0140H Lines 7&9 are masked 4008H Lines 4&15 are masked 0240H Lines 7&10 are masked 8008H Lines 4&16 are masked 0440H Lines 7&11 are masked 0030H Lines 5&6 are masked 0840H Lines 7&12 are masked 0050H Lines 5&7 are masked 1040H Lines 7&13 are masked 0090H Lines 5&8 are masked 2040H Lines 7&14 are masked 0110H Lines 5&9 are masked 4040H Lines 7&15 are masked