Home > NEC > Communications System > NEC Mcu 5000a Multipoint Control Unit Equipment Manual

NEC Mcu 5000a Multipoint Control Unit Equipment Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 702
    							NECA 340-414-220 Revision 2.0 Page 17 of 18
    MCU 5000A Multipoint Control Unit SPR-014
    RS 422 LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    1BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are 
    masked
    2BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are 
    masked
    4BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&15 are 
    masked
    8BFFH
    Lines 1,2,3,4,5,6,7,8,9,10,12&16 are maskedA7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&16 are 
    masked
    33FFH
    Lines 1,2,3,4,5,6,7,8,9,10,13&14 are maskedC7FFH Lines 1,2,3,4,5,6,7,8,9,10,11,15&16 are 
    masked
    53FFH
    Lines 1,2,3,4,5,6,7,8,9,10,13&15 are masked3FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&14 are 
    masked
    93FFH
    Lines 1,2,3,4,5,6,7,8,9,10,13&16 are masked5FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&15 are 
    masked
    63FFH
    Lines 1,2,3,4,5,6,7,8,9,10,14&15 are masked9FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13&16 are 
    masked
    A3FFH
    Lines 1,2,3,4,5,6,7,8,9,10,14&16 are masked6FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&15 are 
    masked
    C3FFH
    Lines 1,2,3,4,5,6,7,8,9,10,15&16 are maskedAFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 14&16 are 
    masked
    1FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&13 are 
    maskedCFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 15&16 are 
    masked
    2FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&14 are 
    masked7FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12, 13, 14&15 
    are masked
    4FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&15 are 
    maskedBFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 14&16 
    are masked
    8FFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12&16 are 
    maskedDFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 15&16 
    are masked
    37FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&14 are 
    maskedFFFFH Lines 1,2,3,4,5,6,7,8,9,10,11,12,13, 
    14,15&16 are masked 
    						
    							Page 18 of 18 NECA 340-414-220 Revision 2.0
    SPR-014 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 4
    MCU 5000A Multipoint Control Unit SPR-015
    H0-INF LIF LINE RATE SETTING
    LINE RELATED
    SUMMARY:Set a per-channel communication rate for the communication channels for the H0 
    lines to and from the connecting conference terminals.  Also set the number of 
    conference terminals (in terms of ports) to be accommodated.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address30H 
    to 37H
    [1] Addresses (hexadecimal values) on setting H0-INF LIF line rate.
    ADDRESS MEANING
    30H
      The line rate of LIF1
    32H The line rate of LIF2
    34H The line rate of LIF3
    36H The line rate of LIF4
    31H The number of ports for LIF1
    33H The number of ports for LIF2
    35H The number of ports for LIF3
    37H The number of ports for LIF4 
    						
    							Page 2 of 4 NECA 340-414-220 Revision 2.0
    SPR-015 MCU 5000A Multipoint Control Unit
    H0-INF LIF LINE RATE SETTING
    LINE RELATED
    STEP PROCEDURE 
    x
    i:
    System parameter value See below:
    [1] System parameter values on setting the line rate for each address (30H, 32H, 34H, 36H).  
    The factory shipment value is 05H
    .
    SYSTEM PARAMETER LINE RATE
    20H  56 kb/s
    30H 56 kb/s×2
    00H 64 kb/s
    10H 64 kb/s×2
    25H 336 kb/s
    05H 384 kb/s
    15H 384 kb/s x 2
    35H 336 kb/s x 2
    [2] System parameter values on setting the number of ports for each address (31H, 33H, 35H, 37H).  
    The factory shipment value is 
    10H.  Refer to Tables 1 and 2. 
    						
    							NECA 340-414-220 Revision 2.0 Page 3 of 4
    MCU 5000A Multipoint Control Unit SPR-015
    H0-INF LIF LINE RATE SETTING
    LINE RELATED
    Table 1: Number of Ports For System Parameter
    SYSTEM 
    PARAMETERNUMBER OF 
    PORTSSYSTEM 
    PARAMETERNUMBER OF 
    PORTSSYSTEM 
    PARAMETERNUMBER OF 
    PORTS
    01H 1 21H 33 41H 65
    02H 2 22H 34 42H 66
    03H 3 23H 35 43H 67
    04H 4 24H 36 44H 68
    05H 5 25H 37 45H 69
    06H 6 26H 38 46H 70
    07H 7 27H 39 47H 71
    08H 8 28H 40 48H 72
    09H 9 29H 41 49H 73
    0AH 10 2AH 42 4AH 74
    0BH 11 2BH 43 4BH 75
    0CH 12 2CH 44 4CH 76
    0DH 13 2DH 45 4DH 77
    0EH 14 2EH 46 4EH 78
    0FH 15 2FH 47 4FH 79
    10H 16 30H 48 50H 80
    11H 17 31H 49 51H 81
    12H 18 32H 50 52H 82
    13H 19 33H 51 53H 83
    14H 20 34H 52 54H 84
    15H 21 35H 53 55H 85
    16H 22 36H 54 56H 86
    17H 23 37H 55 57H 87
    18H 24 38H 56 58H 88
    19H 25 39H 57 59H 89
    1AH 26 3AH 58 5AH 90
    1BH 27 3BH 59 5BH 91
    1CH 28 3CH 60 5CH 92
    1DH 29 3DH 61 5DH 93
    1EH 30 3EH 62 5EH 94
    1FH 31 3FH 63 5FH 95
    20H 32 40H 64 60H 96 
    						
    							Page 4 of 4 NECA 340-414-220 Revision 2.0
    SPR-015 MCU 5000A Multipoint Control Unit
    H0-INF LIF LINE RATE SETTING
    LINE RELATED
    STEP PROCEDURE 
    LINE RATENUMBER OF 
    PORT (SYSTEM 
    PARAMETER)LINE RATENUMBER OF 
    PORT (SYSTEM 
    PARAMETER)LINE RATENUMBER OF 
    PORT (SYSTEM 
    PARAMETER)
    T1 (64 kb/s) 96 (60H) T1 (1152 kb/s) 4 (04H) T1 (448 kb/s) 12 (0CH)
    T1 (128 kb/s) 48 (30H) T1 (1536 kb/s) 4 (04H) T1 (672 kb/s) 8 (08H)
    T1 (192 kb/s) 32 (20H) T1 (56 kb/s) 96 (60H) T1 (1008 kb/s) 4 (04H)
    T1 (256 kb/s) 24 (18H) T1 (112 kb/s) 48 (30H) T1 (1344 kb/s) 4 (04H)
    T1 (384 kb/s) 16 (10H) T1 (168 kb/s) 32 (20H) RS422 4 (04H)
    T1 (512 kb/s) 12 (0CH) T1 (224 kb/s) 24 (18H) RS422 (2×B) 2 (02H)
    T1 (768 kb/s) 8 (08H) T1 (336 kb/s) 16 (10H) INS 48 (30H)
    Valid range of values for system parameter are 00H to FFH.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 18
    MCU 5000A Multipoint Control Unit SPR-016
    H0-INF LIF CLOCK SOURCE SETTING
    LINE RELATED
    SUMMARY: Specifies the line from which to extract the line clock to be used inside the MCU 
    5000A.  When set to “auto”, the line whose line signal is the first to turn normal 
    will be specified as the clock source, but it will be replaced by the lowest-
    numbered line currently in normal operation once the line acting as the clock 
    source then ceases being normal.  When all the terminals are connected via 
    network, use the MCU 5000A on this setting.
    STEP PROCEDURE 
    Note:
    If the physical line number is set with any value from “01H” to “10H”, the line will be fixed 
    as the clock source.  In this case, care must be taken because an abnormal state of the line 
    would lose the clock source and also cause the other lines to lose synchronization.  If the MCU 
    5000A is connected to some terminals directly and to others via network, be sure to use the 
    line connected via network as the clock source.  When set to “internal”, the intra-MCU crystal 
    oscillator clock will supply the line clock.  If MCU 5000A must be connected directly to all 
    the terminals without going through network, use the MCU 5000A with this “internal” setting 
    on. 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address3BH 
    to 3DH
    The addresses for setting the clock source and clock mask are as  shown in the following table.
    ADDRESS MEANING
    3BH Clock source setting
    3CH Clock source masking for lines 1 through 8
    3DH Clock source masking for lines 9 through 16
    xi:
    System parameter values See below:
    [1] System parameter values on setting the clock source for the address 3BH.  The 
    factory shipment value for the system parameter is 00H
    .  
    						
    							Page 2 of 18 NECA 340-414-220 Revision 2.0
    SPR-016 MCU 5000A Multipoint Control Unit
    H0-INF LIF CLOCK SOURCE SETTING
    LINE RELATED
    STEP PROCEDURE 
    SYSTEM PARAMETERCLOCK SOURCE
    (CH)SYSTEM PARAMETERCLOCK SOURCE
    (CH)
    00H Automatic (automatic 
    selection of line in its 
    numerical order)09H 9
    01H 1 0AH 10
    02H 2 0BH 11
    03H 3 0CH 12
    04H 4 0DH 13
    05H 5 0EH 14
    06H 6 0FH 15
    07H 7 10H 16
    08H 8 80H N/A
    [2] System parameter values on setting the clock source mask for the addresses 3CH and 
    3DH.  The factory shipment value is 0000H
    .
    Valid only when setting the clock source, with the masked lines being so controlled as not 
    to function as the clock source.
    See tables on the following pages.
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 3 of 18
    MCU 5000A Multipoint Control Unit SPR-016
    H0-INF LIF CLOCK SOURCE SETTING
    LINE RELATED
    Note:
      Marking a line as masked omits it from automatic selection if 3B = 00
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    0000H No lines masked 0201H Lines 1&10 are masked
    0001H Line 1 is masked 0401H Lines 1&11 are masked
    0002H Line 2 is masked 0801H Lines 1&12 are masked
    0004H Line 3 is masked 1001H Lines 1&13 are masked
    0008H Line 4 is masked 2001H Lines 1&14 are masked
    0010H Line 5 is masked 4001H Lines 1&15 are masked
    0020H Line 6 is masked 8001H Lines 1&16 are masked
    0040H Line 7 is masked 0006H Lines 2&3 are masked
    0080H Line 8 is masked 000AH Lines 2&4 are masked
    0100H Line 9 is masked 0012H Lines 2&5 are masked
    0200H Line 10 is masked 0022H Lines 2&6 are masked
    0400H Line 11 is masked 0042H Lines 2&7 are masked
    0800H Line 12 is masked 0082H Lines 2&8 are masked
    1000H Line 13 is masked 0102H Lines 2&9 are masked
    2000H Line 14 is masked 0202H Lines 2&10 are masked
    4000H Line 15 is masked 0402H Lines 2&11 are masked
    8000H Line 16 is masked 0802H Lines 2&12 are masked
    0003H Lines 1&2 are masked 1002H Lines 2&13 are masked
    0005H Lines 1&3 are masked 2002H Lines 2&14 are masked
    0009H Lines 1&4 are masked 4002H Lines 2&15 are masked
    0011H Lines 1&5 are masked 8002H Lines 2&16 are masked
    0021H Lines 1&6 are masked 000CH Lines 3&4 are masked
    0041H Lines 1&7 are masked 0014H Lines 3&5 are masked
    0081H Lines 1&8 are masked 0024H Lines 3&6 are masked
    0101H Lines 1&9 are masked 0044H Lines 3&7 are masked 
    						
    							Page 4 of 18 NECA 340-414-220 Revision 2.0
    SPR-016 MCU 5000A Multipoint Control Unit
    H0-INF LIF CLOCK SOURCE SETTING
    LINE RELATED
    SYSTEM 
    PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
    PARAMETERLINE NUMBER TO BE MASKED
    0084H Lines 3&8 are masked 0210H Lines 5&10 are masked
    0104H Lines 3&9 are masked 0410H Lines 5&11 are masked
    0204H Lines 3&10 are masked 0810H Lines 5&12 are masked
    0404H Lines 3&11 are masked 1010H Lines 5&13 are masked
    0804H Lines 3&12 are masked 2010H Lines 5&14 are masked
    1004H Lines 3&13 are masked 4010H Lines 5&15 are masked
    2004H Lines 3&14 are masked 8010H Lines 5&16 are masked
    4004H Lines 3&15 are masked 0060H Lines 6&7 are masked
    8004H Lines 3&16 are masked 00A0H Lines 6&8 are masked
    0018H Lines 4&5 are masked 0120H Lines 6&9 are masked
    0028H Lines 4&6 are masked 0220H Lines 6&10 are masked
    0048H Lines 4&7 are masked 0420H Lines 6&11 are masked
    0088H Lines 4&8 are masked 0820H Lines 6&12 are masked
    0108H Lines 4&9 are masked 1020H Lines 6&13 are masked
    0208H Lines 4&10 are masked 2020H Lines 6&14 are masked
    0408H Lines 4&11 are masked 4020H Lines 6&15 are masked
    0808H Lines 4&12 are masked 8020H Lines 6&16 are masked
    1008H Lines 4&13 are masked 00C0H Lines 7&8 are masked
    2008H Lines 4&14 are masked 0140H Lines 7&9 are masked
    4008H Lines 4&15 are masked 0240H Lines 7&10 are masked
    8008H Lines 4&16 are masked 0440H Lines 7&11 are masked
    0030H Lines 5&6 are masked 0840H Lines 7&12 are masked
    0050H Lines 5&7 are masked 1040H Lines 7&13 are masked
    0090H Lines 5&8 are masked 2040H Lines 7&14 are masked
    0110H Lines 5&9 are masked 4040H Lines 7&15 are masked 
    						
    All NEC manuals Comments (0)