    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-003
    CONSOLE COMMUNICATION PARAMETER SETTING
    CONSOLE RELATED
    SUMMARY:Set a parity of communication parameters for consoles 2 and 3.
    Note:
    Communication parameters for MCU console are as follows:
    Line rate: 9600 b/s, 4800 b/s, 2400 b/s, or 1200 b/s
    (This is set on DIP switch of PG/SIO unit.)
    Start bit: 8 bits
    Stop bit: 1 bit
    Parity: None or even parity
    (Even parity can be set in consoles 2 and 3 only.)
    STEP PROCEDURE
    1 Set DIP switch (SW1) on PG/SIO unit for MCU console communication rate, if required.
    2 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … __ ni = xi … ¿
    ni:
    System parameter address02H
    x
    i:
    System parameter values See below:
    System parameter values on setting the parity.  The factory shipment value is 00H
    .
    NOT USED
    CHANNEL 3
    CHANNEL 2
    CHANNEL 1H
    L
    H
    L
    H
    LSW1L H LINE RATE
    OFF OFF 9600 b/s
    ON OFF 4800 b/s
    OFF ON 2400 b/s
    ON ON 1200 b/s 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-003 MCU 5000A Multipoint Control Unit
    CONSOLE COMMUNICATION PARAMETER SETTING
    CONSOLE RELATED
    STEP PROCEDURE
    SYSTEM 
    PARAMETERPARITY SYSTEM 
    PARAMETERSYSTEM 
    PARAMETERPARITY
    CONSOLE 2 CONSOLE 3 CONSOLE 2 CONSOLE 3
    00H 0 0 04H 0 1
    02H 1 0 06H 1 1
    0:  No parity (MCU mode)
    1:  Even parity (VL/TC mode)
    3 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 4
    .
    If NO
    , go to Step 2
    . 
    4 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-004
    CONSOLE CODE INDICATION SETTING
    CONSOLE RELATED
    SUMMARY:Set an addition of local MCU console code to console response or indication to
    ON or OFF in console through-pass control.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … __ ni = xi … ¿
    ni:
    System parameter address08H
    x
    i:
    System parameter values See below:
    System parameter values on setting the code indication.  The factory shipment value is 00H
    .
    SYSTEM PARAMETER MEANING
    00H  Console code (local ID) is not added.
    01H Console code (local ID) is added.
    2Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-004 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-005
    IDENTIFICATION CODE SETTING
    CONSOLE RELATED
    SUMMARY:
    Set the identification code for each console for console-through-path.
    Note:
    In console-through-path, one console can control up to nine consoles.  In 
    the same path, two or more same identification codes cannot be set 
    (identification code is different from each other).
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address09H
    x
    i:
    System parameter values See below:
    System parameter values on setting the identification code.  The factory shipment value is 00H
    .
    SYSTEM 
    PARAMETERIDENTIFICATION CODE SYSTEM 
    PARAMETERIDENTIFICATION CODE
    00H 0 05H 5
    01H 1 06H 6
    02H 2 07H 7
    03H 3 08H 8
    04H 4
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-005 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-006
    CONSOLE PORT SETTING
    CONSOLE RELATED
    SUMMARY:
    Set a port to normal console use or console-through-pass use.  This command also 
    sets whether indication is displayed for each port or not.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … __ ni = xi … ¿
    ni:
    System parameter address0AH
    x
    i:
    System parameter values See below:
    System parameter values on setting the port type and indication for each console.  The factory 
    shipment value is 00H
    .
    [1] Port Type
    SYSTEM 
    PARAMETERPORT TYPE
    PORT 2 PORT 3
    X0H  Normal console port Normal console port
    X2H Through-pass port Normal console port
    X4H Normal console port Through-pass port
    X6H Through-pass port Through-pass port
    X:  Any hexadecimal numeral 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-006 MCU 5000A Multipoint Control Unit
    CONSOLE PORT SETTING
    CONSOLE RELATED
    STEP PROCEDURE 
    [2] Indication
    SYSTEM 
    PARAMETERINDICATION SYSTEM 
    PARAMETERINDICATION
    PORT 1 PORT 2 PORT 3 PORT 1 PORT 2 PORT 3
    0XH YES YES YES 4XH  YES YES NO
    1XH NO YES YES 5XH NO YES NO
    2XH YES NO YES 6XH YES NO NO
    3XH NONO YES 7XH NONONO
    YES: Indication is displayed according to GRRC command or INET command.
    NO: Indication is not displayed.
    X: Any hexadecimal numeral
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 6
    MCU 5000A Multipoint Control Unit SPR-007
    1.5M LIF LINE RATE SETTING
    LINE RELATED
    SUMMARY:
    Set a per-channel communication rate for the communication channels 
    multiplexed to 1536kbps lines to and from multiple conference terminals.  Also 
    set the number of conference terminals (in terms of ports) to be accommodated.
     
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address30H 
    to 37H
    [1] Address (hexadecimal values) in setting 1.5M LIF line rates.
    ADDRESS MEANING
    30H The line rate of LIF1
    32H The line rate of LIF2
    34H The line rate of LIF3
    36H The line rate of LIF4
    31H The number of ports for LIF1
    33H The number of ports for LIF2
    35H The number of ports for LIF3
    37H The number of ports for LIF4 
    						
    							Page 2 o f 6   NECA 340 -41 4-2 20 Revisi on  2.0
    SPR-007   MCU 5000A Mult ipoint Con trol Unit
    1.5M LIF LINE R ATE SETTING
    [2]   Sys tem parameter values on set ting the line rate for  each address (31H, 33H, 35H, 37H ).  The  
    						