    							NECA 340-414-220 Revision 2.0 Page 3 of 6
    MCU 5000A Multipoint Control Unit SPR-007
    1.5M LIF LINE RATE SETTING
    LINE RELATED
    Table 1: Number of Ports for System Parameter
    SYSTEM 
    PARAMETERNUMBER OF 
    PORTSSYSTEM 
    PARAMETERNUMBER OF 
    PORTSSYSTEM 
    PARAMETERNUMBER OF 
    PORTS
    01H 1 21H 33 41H 65
    02H 2 22H 34 42H 66
    03H 3 23H 35 43H 67
    04H 4 24H 36 44H 68
    05H 5 25H 37 45H 69
    06H 6 26H 38 46H 70
    07H 7 27H 39 47H 71
    08H 8 28H 40 48H 72
    09H 9 29H 41 49H 73
    0AH 10 2AH 42 4AH 74
    0BH 11 2BH 43 4BH 75
    0CH 12 2CH 44 4CH 76
    0DH 13 2DH 45 4DH 77
    0EH 14 2EH 46 4EH 78
    0FH 15 2FH 47 4FH 79
    10H 16 30H 48 50H 80
    11H 17 31H 49 51H 81
    12H 18 32H 50 52H 82
    13H 19 33H 51 53H 83
    14H 20 34H 52 54H 84
    15H 21 35H 53 55H 85
    16H 22 36H 54 56H 86
    17H 23 37H 55 57H 87
    18H 24 38H 56 58H 88
    19H 25 39H 57 59H 89
    1AH 26 3AH 58 5AH 90
    1BH 27 3BH 59 5BH 91
    1CH 28 3CH 60 5CH 92
    1DH 29 3DH 61 5DH 93
    1EH 30 3EH 62 5EH 94
    1FH 31 3FH 63 5FH 95
    20H 32 40H 64 60H 96 
    						
    							Page 4 of 6 NECA 340-414-220 Revision 2.0
    SPR-007 MCU 5000A Multipoint Control Unit
    1.5M LIF LINE RATE SETTING
    LINE RELATED
     
    STEP PROCEDURE 
    Table 2: Maximum Number of Available Ports for Line Rate
    LINE RATENUMBER OF 
    PORTS (SYSTEM 
    PARAMETER)LINE RATENUMBER OF 
    PORTS (SYSTEM 
    PARAMETER)LINE RATENUMBER OF 
    PORTS (SYSTEM 
    PARAMETER)
    T1(64kbps) 96 (60H) T1 (1152kbps) 4 (04H) T1 (448kbps) 12 (0CH)
    T1 (128kbps) 48 (30H) T1 (1536kbps) 4 (04H) T1 (672kbps) 8 (08H)
    T1 (192kbps) 32 (20H) T1 (56kbps) 96 (60H) T1 (1008kbps) 4 (04H)
    T1 (256kbps) 24 (18H) T1 (112kbps) 48 (30H) T1 (1344kbps) 4 (04H)
    T1 (384kbps) 16 (10H) T1 (168kbps) 32 (20H) RS422 4 (04H)
    T1 (512kbps) 12 (0CH) T1 (224kbps) 24 (18H) RS422 (2 x B) 2 (02H)
    T1 (768kbps) 8 (08H) T1 (336kbps) 16 (10H) INS 48 (30H)
    Valid range of values for system parameter are 00H to FFH.
    2 Verify that the normal response is displayed with OK
    .
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							NECA 340-414-220 Revision 2.0 Page 5 of 6
    MCU 5000A Multipoint Control Unit SPR-007
    1.5M LIF LINE RATE SETTING
    LINE RELATED
    SOFEWARE SETUP
    The following are addresses that need to be set in the MCU 5000A.  Set the 
    following addresses to the appropriate values and RESET the MCU when 
    complete.
    Note 1:
      If the value other than the ones listed above is set, it will not function.
    Note 2:
      # can not specify the internal clock.(1) Line Speed (+30H, +32H, +34H, +36H)
    ADDRESSLINE SPEED MINIMUM LINE 
    SPEED
    DEFAULT
    T1 RS422 INS-H0
    LIF1 +30H 00H = 64kbps
    01H = 128kbps
    02H = 192kbps
    03H = 256kbps
    04H = 512kbps
    05H = 384kbps
    06H = 768kbps
    07H = 1536kbps
    09H = 1152kbps
    0AH = 1472kbps
    10H = 64kbps x 2
    15H = 384kbps x 2  00H = 64kbps
      01H = 128kbps
      02H = 192kbps
      03H = 256kbps
    #04H = 512kbps
      05H = 384kbps
      06H = 768kbps
      07H = 1536kbps
    #08H = 1920kbps
    #09H = 1152kbps
    10H = 64kbps x 2
    15H = 384kbps x 200H = B
    05H = H0
    10H = 2B
    15H = 384kbps x 2
              (2 x H0)
    05H LIF2 +32H
    LIF3 +34H
    20H = 56kbps
    21H = 112kbps
    22H = 168kbps
    23H = 224kbps
    24H = 448kbps
    25H = 336kbps
    26H = 672kbps
    27H = 1344kbps
    29H = 1008kbps
    2AH = 1288kbps
    30H = 56kbps x 2
    35H = 336kbps x 220H = 56kbps
    21H = 112kbps
    25H = 336kbps
    30H = 56kbps x 2
    35H = 336kbps x 220H = B
    25H = H0
    30H = 2B
    35H = 336kbps x 2
              (2 x H0) LIF4 +36H 
    						
    							Page 6 of 6 NECA 340-414-220 Revision 2.0
    SPR-007 MCU 5000A Multipoint Control Unit
    1.5M LIF LINE RATE SETTING
    LINE RELATED
    (2) Number of Logical Line Speed (+31H, +33H, +35H, +37H)
    ADDRESSNUMBER OF VALID LOGICAL LINE
    T1 RS422 INS-64 DEFAULT
    LIF1 +31H 64kbps : 00H ~ 60H (96)
    128kbps : 00H ~ 30H (48)
    192kbps : 00H ~ 20H (32)
    256kbps : 00H ~ 18H (24)
    384kbps : 00H ~ 10H (16)
    512kbps : 00H ~ 00H (12)
    768kbps : 00H ~ 08H (8)
    1152kbps : 00H ~ 04H (4)
    1472kbps : 00H ~ 04H (4)
    1536kbps : 00H ~ 04H (4)00H ~ 04H
    (When 2 x B: 00H ~ 
    02H)00H ~ 30H (48) 10H LIF2 +32H
    LIF3 +35H
    56kbps : 00H ~ 60H (96)
    112kbps : 00H ~ 30H (48)
    168kbps : 00H ~ 20H (32)
    224kbps : 00H ~ 18H (24)
    336kbps : 00H ~ 10H (16)
    448kbps : 00H ~ 00H (12)
    672kbps : 00H ~ 08H (8)
    1008kbps : 00H ~ 04H (4)
    1288kbps : 00H ~ 04H (4)
    1344kbps : 00H ~ 04H (4) LIF4 +37H 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-008
    1.5M LIF FRAME FORMAT SETTING
    LINE RELATED
    SUMMARY: 
    Set the line frame format.
    STEP PROCEDURE 
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address38H
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the frame format for the address 38H
    .  The factory 
    shipment value for the system parameter is 00H
    .
    (1) Frame Format (+38H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    LIF4                       LIF3                       LIF2                      LIF1
    00H = ESF (24MF)
    01H = F4
    02H = D4 (12MF)
    03H = F72
    2 Verify that the normal response is displayed with 
    OK.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-008 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-009
    1.5M LIF LINE CODE SETTING
    LINE RELATED
    SUMMARY:
    Set the line code form.  The line code can be set to each unit.  When the code form 
    is in AMI as in the North American lines, it is necessary to set the network class to 
    the constrained network (P×56 kbps) in order to prevent the appearance in string 
    of eight  consecutive 0s (zeroes).
    STEP PROCEDURE 
    Note:
    When setting the AMI code, simultaneously set the network  classification capability (112H 
    and 113H) as well as the network classification mode (132H and 133H) to “56 kbps  
    (constrained)”.  Also set the CODEC (VL5000) on the terminal side to “56 kbps”
    1 Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address39H
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the line rate for the address 39H.  The factory 
    shipment value for the system parameter is 
    00H.
    (1) Line Code (+39H)
    b7
    b6b5
    b4 b3 b2 b1 b0
    LIF4                       LIF3                       LIF2                      LIF1
    00H = B8ZS
    01H = AMI
    02H = AMI (ZCS)
    Default = 00H
    2Verify that the normal response is displayed with “
    OK”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    .
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0
    SPR-009 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-220 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit SPR-010
    1.5M LIF RAI SETTING
    LINE RELATED
    SUMMARY:
    Set the alarm signal types.  The alarm signal types can be set to each unit.
    STEP PROCEDURE 
    Note:
    When the frame format is “D4 (12MF)”, the RAI  (alarm signal) form in T1 (USA) is different 
    from that in NTT (Japan).   Only when connecting to NTT lines with “F12”, set the mode to  
    “NTT.”
    1Enter the following command.
    SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
    ni:
    System parameter address3AH
    x
    i:
    System parameter values See below:
    [1] System parameter values on setting the line rate for the address 3AH.
    The factory shipment value for the system parameter is 00H
    .
    (1) RAI Type (+3AH)
    b7
    b6b5
    b4 b3 b2 b1 b0
    LIF4                       LIF3                       LIF2                      LIF1
    00H = T1 (ATT)
    01H = NTT (12MF)I
    Default = 00H
    2 Verify that the normal response is displayed with “OK
    ”.
    If YES
    , go to Step 3
    .
    If NO
    , go to Step 1
    . 
    3 End of procedure. 
    						
    							Page 2 of 2 NECA 340-414-220 Revision 2.0