NECA 340-414-220 Revision 2.0 Page 3 of 6 MCU 5000A Multipoint Control Unit SPR-007 1.5M LIF LINE RATE SETTING LINE RELATED Table 1: Number of Ports for System Parameter SYSTEM PARAMETERNUMBER OF PORTSSYSTEM PARAMETERNUMBER OF PORTSSYSTEM PARAMETERNUMBER OF PORTS 01H 1 21H 33 41H 65 02H 2 22H 34 42H 66 03H 3 23H 35 43H 67 04H 4 24H 36 44H 68 05H 5 25H 37 45H 69 06H 6 26H 38 46H 70 07H 7 27H 39 47H 71 08H 8 28H 40 48H 72 09H 9 29H 41 49H 73 0AH 10 2AH 42 4AH 74 0BH 11 2BH 43 4BH 75 0CH 12 2CH 44 4CH 76 0DH 13 2DH 45 4DH 77 0EH 14 2EH 46 4EH 78 0FH 15 2FH 47 4FH 79 10H 16 30H 48 50H 80 11H 17 31H 49 51H 81 12H 18 32H 50 52H 82 13H 19 33H 51 53H 83 14H 20 34H 52 54H 84 15H 21 35H 53 55H 85 16H 22 36H 54 56H 86 17H 23 37H 55 57H 87 18H 24 38H 56 58H 88 19H 25 39H 57 59H 89 1AH 26 3AH 58 5AH 90 1BH 27 3BH 59 5BH 91 1CH 28 3CH 60 5CH 92 1DH 29 3DH 61 5DH 93 1EH 30 3EH 62 5EH 94 1FH 31 3FH 63 5FH 95 20H 32 40H 64 60H 96
Page 4 of 6 NECA 340-414-220 Revision 2.0 SPR-007 MCU 5000A Multipoint Control Unit 1.5M LIF LINE RATE SETTING LINE RELATED STEP PROCEDURE Table 2: Maximum Number of Available Ports for Line Rate LINE RATENUMBER OF PORTS (SYSTEM PARAMETER)LINE RATENUMBER OF PORTS (SYSTEM PARAMETER)LINE RATENUMBER OF PORTS (SYSTEM PARAMETER) T1(64kbps) 96 (60H) T1 (1152kbps) 4 (04H) T1 (448kbps) 12 (0CH) T1 (128kbps) 48 (30H) T1 (1536kbps) 4 (04H) T1 (672kbps) 8 (08H) T1 (192kbps) 32 (20H) T1 (56kbps) 96 (60H) T1 (1008kbps) 4 (04H) T1 (256kbps) 24 (18H) T1 (112kbps) 48 (30H) T1 (1344kbps) 4 (04H) T1 (384kbps) 16 (10H) T1 (168kbps) 32 (20H) RS422 4 (04H) T1 (512kbps) 12 (0CH) T1 (224kbps) 24 (18H) RS422 (2 x B) 2 (02H) T1 (768kbps) 8 (08H) T1 (336kbps) 16 (10H) INS 48 (30H) Valid range of values for system parameter are 00H to FFH. 2 Verify that the normal response is displayed with OK . If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
NECA 340-414-220 Revision 2.0 Page 5 of 6 MCU 5000A Multipoint Control Unit SPR-007 1.5M LIF LINE RATE SETTING LINE RELATED SOFEWARE SETUP The following are addresses that need to be set in the MCU 5000A. Set the following addresses to the appropriate values and RESET the MCU when complete. Note 1: If the value other than the ones listed above is set, it will not function. Note 2: # can not specify the internal clock.(1) Line Speed (+30H, +32H, +34H, +36H) ADDRESSLINE SPEED MINIMUM LINE SPEED DEFAULT T1 RS422 INS-H0 LIF1 +30H 00H = 64kbps 01H = 128kbps 02H = 192kbps 03H = 256kbps 04H = 512kbps 05H = 384kbps 06H = 768kbps 07H = 1536kbps 09H = 1152kbps 0AH = 1472kbps 10H = 64kbps x 2 15H = 384kbps x 2 00H = 64kbps 01H = 128kbps 02H = 192kbps 03H = 256kbps #04H = 512kbps 05H = 384kbps 06H = 768kbps 07H = 1536kbps #08H = 1920kbps #09H = 1152kbps 10H = 64kbps x 2 15H = 384kbps x 200H = B 05H = H0 10H = 2B 15H = 384kbps x 2 (2 x H0) 05H LIF2 +32H LIF3 +34H 20H = 56kbps 21H = 112kbps 22H = 168kbps 23H = 224kbps 24H = 448kbps 25H = 336kbps 26H = 672kbps 27H = 1344kbps 29H = 1008kbps 2AH = 1288kbps 30H = 56kbps x 2 35H = 336kbps x 220H = 56kbps 21H = 112kbps 25H = 336kbps 30H = 56kbps x 2 35H = 336kbps x 220H = B 25H = H0 30H = 2B 35H = 336kbps x 2 (2 x H0) LIF4 +36H
Page 6 of 6 NECA 340-414-220 Revision 2.0 SPR-007 MCU 5000A Multipoint Control Unit 1.5M LIF LINE RATE SETTING LINE RELATED (2) Number of Logical Line Speed (+31H, +33H, +35H, +37H) ADDRESSNUMBER OF VALID LOGICAL LINE T1 RS422 INS-64 DEFAULT LIF1 +31H 64kbps : 00H ~ 60H (96) 128kbps : 00H ~ 30H (48) 192kbps : 00H ~ 20H (32) 256kbps : 00H ~ 18H (24) 384kbps : 00H ~ 10H (16) 512kbps : 00H ~ 00H (12) 768kbps : 00H ~ 08H (8) 1152kbps : 00H ~ 04H (4) 1472kbps : 00H ~ 04H (4) 1536kbps : 00H ~ 04H (4)00H ~ 04H (When 2 x B: 00H ~ 02H)00H ~ 30H (48) 10H LIF2 +32H LIF3 +35H 56kbps : 00H ~ 60H (96) 112kbps : 00H ~ 30H (48) 168kbps : 00H ~ 20H (32) 224kbps : 00H ~ 18H (24) 336kbps : 00H ~ 10H (16) 448kbps : 00H ~ 00H (12) 672kbps : 00H ~ 08H (8) 1008kbps : 00H ~ 04H (4) 1288kbps : 00H ~ 04H (4) 1344kbps : 00H ~ 04H (4) LIF4 +37H
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-008 1.5M LIF FRAME FORMAT SETTING LINE RELATED SUMMARY: Set the line frame format. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address38H x i: System parameter values See below: [1] System parameter values on setting the frame format for the address 38H . The factory shipment value for the system parameter is 00H . (1) Frame Format (+38H) b7 b6b5 b4 b3 b2 b1 b0 LIF4 LIF3 LIF2 LIF1 00H = ESF (24MF) 01H = F4 02H = D4 (12MF) 03H = F72 2 Verify that the normal response is displayed with OK. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-008 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-009 1.5M LIF LINE CODE SETTING LINE RELATED SUMMARY: Set the line code form. The line code can be set to each unit. When the code form is in AMI as in the North American lines, it is necessary to set the network class to the constrained network (P×56 kbps) in order to prevent the appearance in string of eight consecutive 0s (zeroes). STEP PROCEDURE Note: When setting the AMI code, simultaneously set the network classification capability (112H and 113H) as well as the network classification mode (132H and 133H) to “56 kbps (constrained)”. Also set the CODEC (VL5000) on the terminal side to “56 kbps” 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address39H x i: System parameter values See below: [1] System parameter values on setting the line rate for the address 39H. The factory shipment value for the system parameter is 00H. (1) Line Code (+39H) b7 b6b5 b4 b3 b2 b1 b0 LIF4 LIF3 LIF2 LIF1 00H = B8ZS 01H = AMI 02H = AMI (ZCS) Default = 00H 2Verify that the normal response is displayed with “ OK”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-009 MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-010 1.5M LIF RAI SETTING LINE RELATED SUMMARY: Set the alarm signal types. The alarm signal types can be set to each unit. STEP PROCEDURE Note: When the frame format is “D4 (12MF)”, the RAI (alarm signal) form in T1 (USA) is different from that in NTT (Japan). Only when connecting to NTT lines with “F12”, set the mode to “NTT.” 1Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address3AH x i: System parameter values See below: [1] System parameter values on setting the line rate for the address 3AH. The factory shipment value for the system parameter is 00H . (1) RAI Type (+3AH) b7 b6b5 b4 b3 b2 b1 b0 LIF4 LIF3 LIF2 LIF1 00H = T1 (ATT) 01H = NTT (12MF)I Default = 00H 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-010 MCU 5000A Multipoint Control Unit This page is for your notes.