    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   COP-138
    RCNN
    BCONn
    UCONn [n … ]
    LCONn [n … ]
    MCONn  … [MnSs …  ]
    MCNR nRx
    B CON7
    UCON356
    MCON8101112 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-138 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-300 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit COP-139
    MCON
    Mutlipoint/Lecture Connection Control
    COMMAND NAME
    Multi point CONnect
    PURPOSE
    This command is used to establish H.320 multipoint connections.  The specified 
    terminal (room) can participate in the multipoint teleconference.  When the line 
    number is set to 0, line connection is not established and the teleconference room 
    number is skipped.  In the cascade connection, the MCU acts as a master-side.
    INPUT FORMAT
    MCON     nm1     nm2     nm3 … [Mnc     Snx     ns1     ns2 … ][     Rr][__S] ¿
    EXPLANATION OF INPUT PARAMETERS
    n
    i =1 ~ 254
    Specifies the logic line number of the terminal to be multi-
    connected.  
    i = m
    jSpecifies the terminal logic line number to be connected in the 
    Master MCU.
    i = x Specifies the slave number.
    i = s
    jSpecifies the terminal logic line number  to be connected to 
    Slave-side MCU.
    i = c Specifies the logic line number of cascade port.
    r = Specifies a bit rate (kb/s).  Note that a bit rate corresponds to the 
    type of line interface.  If this parameter is no value (not entered), 
    the default bit rate (system parameter value) is used.  Valid values 
    for r are:
    56, 56X2, 64, 64X2, 112, 128, 168, 192, 224, 256, 336, 384, 448, 512, 
    672, 768, 1008, 1152, 1344, 1536, 1920, 1472, 1288, 384x2, 336x2
    S = B, 2B, H0, or 2H0
    Specifies the line speed. 
    						
    							Page 2 o f 2   NECA 340 -41 4-3 00 Revisi on  2.0
    CO P-139   MCU 5000A Mult ipoint Con trol Unit
    MCON
    mmx kb psOK
    2345 ¿
    010203043 84 kbpsOK 
    						
    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   COP-140
    MDSC
    g] ¿
    A ¿ 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-140 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						
    							NECA 340-414-300 Revision 2.0 Page 1 of 2
    MCU 5000A Multipoint Control Unit COP-141
    ECON
    Mutlipoint/Lecture Connection Control
    COMMAND NAME
    *Education mode multi point CONnection
    PURPOSE
    This command is used to establish a multipoint connection in an education mode.  
    In this connection, voice activated switching is deactivated.
    INPUT FORMAT
    ECON     [I]nm1     [I]nm2     [I]nm3 … [Mnc     Snx     [I]ns1     [I]ns2 … ][     Rr][     s] ¿
    EXPLANATION OF INPUT PARAMETERS
    n
    i=1 ~ 254
    Specifies the logic line number of the terminal to be multi-
    connected.  
    i=m
    jSpecifies the logic line number of the terminal to be connected to 
    Master-side MCU.
    i=x Specifies the slave number.
    i=s
    jSpecifies the logic line number of the terminal to be connected to 
    Slave-side MCU.
    i=c Specifies the logic line number of the cascade port.
    I: Specifies an instructor terminal.  I should be entered for an 
    instructor terminal. 
    Note:
    Each group can provide only one instructor terminal.  The 
    instructor terminal is not set to voice terminal.
    r= Specifies the bit rate (kbps).  Note that the bit rate corresponds to 
    the type of line interface.  If this parameter is no value (not entered), 
    the default bit rate (system parameter value) is used.  Valid values 
    for r are:56, 56X2, 64, 64X2, 112, 128, 168, 192, 224, 256, 336, 
    384, 448, 512, 672, 768, 1008, 1152, 1344, 1536, 1920, 1288, 1472, 
    384X2, 336X2
    S: B, 2B, H0, or 2H0
    Specifies the line speed
    *Future Release 
    						
    							Page 2 o f 2   NECA 340 -41 4-3 00 Revisi on  2.0
    CO P-141   MCU 5000A Mult ipoint Con trol Unit
    ECON
    [ I]m[ I]mxkb psOK
    2I345 ¿
    02I030405384k bpsOK 
    						
    							NECA 340-4 14- 30 0  Revisio n 2.0   Page 1 o f 2
    MCU  5000A Multipoint Control  U nit   COP-142
    EDSC
    g] ¿
    A ¿ 
    						
    							Page 2 of 2 NECA 340-414-300 Revision 2.0
    COP-142 MCU 5000A Multipoint Control Unit
    This page is for your notes. 
    						