NECA 340-414-100 Revision 2.0Page v MCU 5000A Multipoint Control Unit List of Tables List of Tables Table 2-1: MCU 5000A Unit Component.................................................................. 3 Table 2-2: MCU 5000A Cable Component ............................................................... 4 Table 3-1: Line Rate ................................................................................................ 12 Table 3-2: Number of Logical Lines ...................................................................... 12 Table 4-1: Electrical Specification ......................................................................... 25 Table 4-2: 1.5M LIF (CH1 to CH16) Signal Assignment ....................................... 26 Table 4-3: User Side Primary Tributary Rate Layer 1 Status Transition ............ 27 Table 4-4: Electrical Specification ......................................................................... 28 Table 4-5: RS-422 LIF (CH1 to CH16) Signal Assignment ................................... 29 Table 4-6: Electrical Specification ......................................................................... 33 Table 4-7: H0-INF (CH1 to CH6) Signal Assignment ............................................ 33 Table 4-8: Voice Signal Level Setting Value ......................................................... 40 Table 4-9: RS-232C Parameter ............................................................................... 45 Table 6-1: MCU 5000A Electrical Specification .................................................... 60 Table 7-1: Detail Command/Response (1 of 3) ..................................................... 70 Table 7-1: Detail Command/Response (2 of 3) ..................................................... 71 Table 7-1: Detail Command/Response (3 of 3 ...................................................... 72 Table 8-1: Console Command List ........................................................................ 81 Table 9-1: System Parameter Setting .................................................................... 85
Page viNECA 340-414-100 Revision 2.0 List of Tables MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-100 Revision 2.0Page 1 MCU 5000A Multipoint Control Unit General Description Manual 1: GENERAL A: Overview 1.01 The MCU 5000A is a network control equipment which interconnects the plural remote teleconference terminals in multimedia conference system. The MCU 5000A transmits audio, motion/still picture image, etc. via transmission line. The MCU 5000A located at the center in the network as the radical topology, performs the line connection, video signal switching, and audio sum process. 1.02 The MCU 5000A is able to control maximum 16 lines. Maximum eight lines in 16 lines are available to the multipoint teleconference, and the rest lines are available to point-to-point or broadcasting teleconference. When two MCU 5000As are connecting by cascade-connection, maximum 14 lines are available to the multipoint teleconference. The number of point-to-point or broadcasting connecting terminals is flexible according to the transmission rate. In the H.243 mode, the maximum is 20 sites, with 3 cascaded MCUs. 1.03 During multipoint teleconference performance, received picture image is automatically switched current talker according to the talker voice detection or level decision. The MCU 5000A mixes audio signals whenever it receives then from all terminals and returns the mixed signals back to all terminal. Each terminal receives the audio signals of all other terminals constantly except its own signal. 1.04 The MCU 5000A with the teleconference terminal (VisuaLink AD series) provides the following features. • Broadcasting: To broadcast the picture image of any teleconference terminal to all the other participating teleconference terminals. • Selective receiving: To select receiving picture image of any terminal out of those of all the participating teleconference terminal. Does not apply to cascaded terminals. • Operator switching: To control the switching of the broadcasting picture image collectively. • Still picture signal transmitting: To transmit still picture image to all the other participating teleconference terminal. • Camera remote control: To control the camera of the terminal from which signal is received. In proprietary mode. 1.05 The tele-education connection can be performed using the optional software. The terminals are divided to one instructor site and plural classroom in this connection state. The instructor site broadcasts own video and voice data to classroom, and control the system. All cameras are controlled instructor site. The instructor and privilege listener are able to send their data (video, voice, and electrical whiteboard) to other terminals.
Page 2NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit This page is for your notes.
NECA 340-414-100 Revision 2.0Page 3 MCU 5000A Multipoint Control Unit General Description Manual 2: SYSTEM CONFIGURATION A: Basic Configuration2.01 The combination of units as shown in the Table 2-1 is required depending on the line type or number of lines. B: Option Line Growth 2.02 To expand any teleconference terminal into MCU system, the line interface increasing is required only. In conformity with the line interface, one of the following units is added in the MCU 5000A. • 1.5M LIF unit: 4 lines per unit • RS-422 LIF unit: 4 or 2 lines per unit (In case of 2×B, 2 lines per unit) • H0-INF unit: 2 lines per unit Simultaneously Connecting Teleconference 2.03 To expand the teleconference terminals due to the multipoint connection, the following 2 units must be added in the MCU 5000A with line expanding action in paragraph 2.02. • EC H221 MUX Unit: 1 terminal per unit (Maximum 8 units per subrack) • A CODEC unit: 4 terminals per unit (Maximum 2 units per subrack) Table 2-1: MCU 5000A Unit Component UNIT ITEM DESCRIPTION CODE CommonMCU 5000A SUBRACK (F1341G) 1 pc V53 M CONT (Y2573A) 1 pc PG SIO (Y1441A) 1 pc A SUM (Y1439A) 1 pc V SW/LSD IF (Y1440A) 1 pc MEMORY CARD (Y32-MC0003-07+F1341-0606) 1 pc PWR (1 unit per subrack)A AC117V POWER E32-014-Y1573-0B00 B DC -48V (UL) POWER E32-014-Y3757-0A00 A CODEC (Maximum 2 units per subrack)A CODEC (4CH/UNIT) E32-441-Y1438-0A00 EC H221 MUX (Maximum 8 units per subrack)EC H221 MUX (1CH/UNIT) E32-482-Y3118-0B00 LIF UNIT (Maximum 4 units per subrack)A 1.5M LIF (4CH/UNIT) E32-484-Y1442-0A00 B RS-422/HSD IF (4CH/UNIT) E32-484-Y1443-0A00 C H0-INF (2CH/UNIT) E32-484-Y2761-0A00 Data Switch (for Data Distribute)VDSW E32-465-Y4775-0A00
Page 4NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit Connecting Cable 2.04 The connection between MCU 5000A and teleconference terminals is performed by the connecting cable required for user specification. Table 2-2 shows the cable components of MCU 5000A. Accessories 2.05 The accessories for MCU 5000A are as follows. • Mounting Screws on subrack (Special screw): 8 pcs. • Connector for LIF interface (D-sub 15-pin) : 16 pcs. • Power connection cable : 1 pc. • Memory Card : 1 pc. • User’s Manual : 1 copy Table 2-2: MCU 5000A CABLE COMPONENT UNIT ITEM DESCRIPTION T1 CableA 15Pin-15Pin Conversion (Straight)10 meter (for T1 DCE Interface Device Connection) B 15Pin-15Pin Conversion (Cross)10 meter (for T1 DTE Interface Device Connection) Conversion Cable for RS-422/HSD IF Unit (When a given cable (1 meter) is shortage.)A 15Pin-37Pin Conversion (Straight)10 meter (for RS-449 DCE Interface Device Connection) B 15Pin-37Pin Conversion (Cross)10 meter (for RS-449 DTE Interface Device Connection) RS-449 Cable 37Pin-37Pin Conversion (Straight)10 meter Conversion Cable for H0 INTF UnitA 15 Pin Modular jack Conversion Cable 3 meter (for ISDN Connection) B 15 Pin Modular jack Conversion Cable 5 meter (for ISDN Connection) C 15 Pin Modular jack Conversion Cable 10 meter (for ISDN Connection) X21 Connection CableA 15Pin-15Pin Conversion (Straight) 2 meter B 15Pin-15Pin Conversion (Cross) 2 meter RS-232C CableA 25Pin-25Pin Conversion (Straight) 2 meter B1 25Pin-25Pin Conversion (Cross) 2 meter B2 25Pin-25Pin Conversion (Cross) 5 meter B3 25Pin-25Pin Conversion (Cross) 10 meter
NECA 340-414-100 Revision 2.0Page 5 MCU 5000A Multipoint Control Unit General Description Manual 3: SYSTEM FEATURES A: Basic Connection 3.01 The MCU 5000A rearplate contains sixteen line connection ports, eight HSD data ports, and four RS-232C interface ports. These ports are located on as shown in Fig. 3-1. Refer to the NECA 340-414-210. 3.02 The line connection ports (LIF: CH 1 to CH 16) access to the line of the teleconference terminal. The MCU 5000A cascade-connection is required to connect between two MCU 5000A line connectors using the suitable cable (reverse) as LIF unit. 3.03 The console connection connectors (RS-232C: CH 1 to CH 4) access to the MCU 5000A Control Console or plural MCU 5000A Control Console with the through-pass cable* (CH 2 or CH 3 only). The RS-232C CH4 port is used to connect debug station, therefore CH4 can not be used for normal operation. B: Usable Teleconference Terminal3.04 The MCU 5000A can be connected to the CODEC which conforms with ITU-TS Recommendation H.221/H.242. The remote control function can be performed to operate from NEC’s CODEC or terminal only. NEC does not guarantee for connecting to the CODEC or terminal which is provided by other manufacture. Figure 3-1: Typical Connecting Diagram * Through-pass Cable for serial connection This cable is used for connecting between plural MCU 5000As (Maximum eight). Refer to Section K in this manual. RS-232C HSDLIF CH1 CH2 CH3 CH4 CONSOLE FOR DEBUG LINE
Page 6NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit C: Start-up of EquipmentStart-up 3.05 Turn ON the power switch inside of the MCU 5000A front cover after confirm the memory card is installed. The memory card is of SRAM or ROM type and backed up by a lithium battery. The operation program for the MCU 5000A is registered in the memory card and downloaded at system starting. The system start-up has completed normally following message is displayed in MCU console. Note: XX.XX indicates the version number of the memory card in the MCU 5000A System Parameter Setting 3.06 On installation, line rate and interface parameters setting are required according to the user installation environmental and performing condition. System parameters are stored in the backup inside memory (backup by lithium battery). When system parameters is set once, parameter setting is not required since then. Refer to the NECA 340-414-220. D: Teleconference Ty p e3.07 The MCU 5000A provides the following type of teleconference. These plural teleconferences can be performed simultaneously. Point-to-Point Teleconference 3.08 The line is connected with point-to-point regarding the video and audio without MCU 5000A. Possible connecting number of lines is flexible for line rate that line capacity of point-to-point (Line rate×2×number of point-to-point) and line capacity of broadcasting connection are added. It is possible to line- connect up to total 16 Mb/s (2 Mb/s×8). Broadcast Teleconference 3.09 This type broadcasts the video and audio signal of one originating source to the plural points. For the video and audio signal, the MCU 5000A does not control as same as Point-to-Point teleconference. This connecting condition is the unidirection (one way). The teleconference terminal operation is required without H.242 capacity conversion mode. Local loopback connection is also available. The possible connecting number is the same to point-to-point teleconference. **** Multipoint Teleconference control unit MCU 5000A Ver XX.XX **** **** Copyright (C) NEC Corporation 1990, 1993 ****
NECA 340-414-100 Revision 2.0Page 7 MCU 5000A Multipoint Control Unit General Description Manual Multipoint Teleconference (RCON) 3.10 Multipoint teleconference is the teleconference system as the terminals of more than three points with the console or wireless remote controller of terminal is connected. 3.11 The video, audio, and control data are extracted from H.221 frame signal, and MCU 5000A processes and controls such as video switching and audio sum with their data. Their data is multiplexed again, then transmit to the teleconference terminals. The following features are provided in multipoint teleconference. • One MCU 5000A has the ability to connect eight (8) terminals, and three (3) MCU 5000As cascade-connection can be connected to maximum twenty (20) terminals in one multipoint teleconference simultaneously. • One MCU 5000A has the ability to perform two (2) multipoint teleconference groups within maximum eight (8) terminals per one group (enable different line rate). Two MCU 5000As cascade-connection can provide the maximum three (3)groups. • The video signal of terminal joined at first is broadcasted. • Through the broadcasting source is switched to the originating image automatically by the talker detecting function, that switching operation can be changed forcibly with the [LOCAL SEND] key on remote controller. • One of the teleconference terminals can be specified as chairman. The terminal as chairman forcibly operates to switch the video image ([OPR] key on remote controller). In this case, talker detection does not function spontaneously. • The specific receiving video signal can be selected by the [SLCT RCV] key on remote controller prior to the video signal switching function. • The incoming audio signals from all the terminal are mixed, and then distributed to all of the terminals. The mixed audio signal sent to each terminal is cut the audio signal of its own terminal off. • The teleconference terminal name can be indicated on the screen of terminal with the superimpose using by [SITE LIST] key on remote controller. • The teleconference terminal is identified by beginning “1” number (teleconference number) assigned by MCU 5000A. • H.242 capacity conversion function can adjust the line rate between the different line rate terminals on the MCU 5000A side. • Any still picture signal can be sent to all of the terminals. ([STILL SEND] key on remote controller) • Message tone can be sent to all of the terminals. • H.243 Data Distribution function is available. (Needs VDSW unit)
Page 8NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit Multipoint Teleconference (MCON) 3.12 Multipoint teleconference is the teleconference system as the terminals of more than three points with the console or wireless remote controller of terminal is connected. 3.13 The video, audio, and control data are extracted from H.221 frame signal, and MCU 5000A processes and controls such as video switching and audio sum with their data. Their data is multiplexed again, then transmit to the teleconference terminals. The following features are provided in multipoint teleconference. • One MCU 5000A has the ability to connect eight (8) terminals, and two (2) MCU 5000As cascade-connection can be connected to maximum fourteen (14) terminals in one multipoint teleconference simultaneously. • One MCU 5000A has the ability to perform two (2) multipoint teleconference groups within maximum eight (8) terminals per one group (enable different line rate). Two (2) MCU 5000As cascade-connection can provide the maximum three (3)groups. • The video signal of terminal joined at last is broadcasted (last terminal indicates the video image of the prior terminal). • Through the broadcasting source is switched to the originating image automatically by the talker detecting function, that switching operation can be changed forcibly with the [LOCAL SEND] key on remote controller. Also talker detection can be inhibited with [VOICE ACTIVATE] key on the remote controller. • One of the teleconference terminals can be specified as chairman. The terminal as chairman forcibly operates to switch the video image ([OPR] key on remote controller). In this case, talker detection does not function spontaneously. • The specific receiving video signal can be selected by the [SLCT RCV] key on remote controller prior to the video signal switching function. The console command, switching the current video image to the specific terminal image, is provided without use of the specified receiving function for the broadcasting source. • The incoming audio signals from all the terminal are mixed, and then distributed to all of the terminals. The mixed audio signal sent to each terminal is cut the audio signal of its own terminal off. • The teleconference terminal name can be indicated on the screen of terminal with the superimpose using by [SITE LIST] key on remote controller. When setting the system parameter, the teleconference terminal name registered is transferred to all of the terminals on connecting. Using the console command, the terminal name can be changed temporarily. • The teleconference terminal is identified by beginning “1” number (teleconference number) assigned by MCU 5000A. • H.242 capacity conversion function can adjust the line rate between the different line rate terminals on the MCU 5000A side.