GE Logiq 9 Service Manual
Have a look at the manual GE Logiq 9 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 9 Renewal Parts 9-39 Section 9-18 Voice Scan Figure 9-24 Voice Scan Replacement Parts Table 9-21 Voice Scan Item Part NamePart NumberDescriptionQtyFRU 750Wireless Receiver 2383770 1 1 751Battery Eliminator Cable 2383769 1 1 752Audio to USB Adapter 2383765 1 1 753Audio Cable from Receiver238376811 754Power Cable for Receiver238376711 755Tray for Wireless Receiver237759912 756Foam - Wireless Receiver Bottom 2377600 1 2 757Foam - Wireless Receiver Top 2377601 1 2 758AC Adapter - 9V, 1.1A 2384314 1 1 759USB Extension Cable238444911 760Battery Charger238377511 761Battery - 9V NiMH238377631 762Microphone 2383779 Over the ear style. 1 1 763USB Headset 2386172 1 1 764Wireless Microphone Care Kit 2386142 1 1 765Beltpack Transmitter - Wireless238377311 766Adapter Kit - 240Vac239011711 760 761 762 765 766
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 9-40 Section 9-19 - Customer Documentation Section 9-19 Customer Documentation Figure 9-25 Customer Documentation Package Table 9-22 Documentation Box Contents ItemPart NamePart NumberDescriptionQtyFRU Customer Documentation Collector2376865 Includes items 800-808 1 N 800LOGIQ™ 9 Customer Documentation CD2353630-200All available documents in PDF format. Can be viewed on the scanner or any PC Includes service and user manuals.1N 801 LOGIQ™ 9 Installation Manual2301715-100Basic Installation and how to view documents on the CD1N 802LOGIQ™ 9 Quick Guide2309820-100Basic scanner operation1N 803LOGIQ™ 9 Release Notes2320595-100R2.1.0 Software1N 804LOGIQ™ 9 Release Notes Addendum2376420-100R2.1.1 Addendum1N 805 LOGIQ™ 9 Quick Card #12309821-100 1 N 806 LOGIQ™ 9 EFBW Quick Card2323180-100 EFBW Procedures 1 N 807LOGIQ™ 9 AUA vs. CUA (linear regression)2323181-100 AUA vs. CUA 1 N 808LOGIQ™ 9 Op Panel P-Key Labels2376993Labels for Print Key assignments1N
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 9 Renewal Parts 9-41 Section 9-20 Probes Figure 9-26 LOGIQ™ 9 Probes Table 9-23 Available Probes ItemPart NamePart NumberDescriptionQtyFRU 9013.5C 2296158 H4901PE - PDI 1 902M7C 2294514 H4901PG - Hino 1 903E8C 2294641 H4901PM - Hino 1 9047L2294521H4901PH - Hino1 90510L2294523H4901PJ - Hino1 906M12L2294511H4901PK - Hino1 907i12L 2264883 H4901PL - PDI 1 9084S 2295658 H4901PB - PDI 1 90910S 2298589 H4901PC - PDI 1 9108C2348094Q1 2003 Release1 911TCD 3S2323337T3308MC1 9123.5CS2051858H40412LK1 913Probe Latching Mechanism 2130769 Large round blue locking knob used on some probes 1 901902903904905906 908909907910911912
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 9-42 Section 9-20 - Probes This page was intentionally left blank.
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 10 Periodic Maintenance 10-1 Chapter 10 Periodic Maintenance Section 10-1 Overview 10-1-1 Purpose of Chapter 10 This chapter describes Periodic Maintenance (PM) and customer performed tasks on the scanner and peripherals. These procedures are intended to maintain the quality of the ultrasound systems performance. Read this chapter completely and familiarize yourself with the procedures before performing a task. Table 10-1 Contents in Chapter 10 SectionDescriptionPage Number 10-1 Overview10-1 10-2 Why do Periodic Maintenance10-2 10-3 Maintenance Task Schedule10-2 10-4Tools Required10-4 10-5System Periodic Maintenance10-7 10-6Using a Phantom10-12 10-7 Electrical Safety Tests10-12 10-8 When Theres Too Much Leakage Current...10-28 PM INSPECTION Certificate10-29 CAUTIONPractice good ESD prevention. Wear an anti–static strap when handling electronic parts and even when disconnecting/connecting cables. DANGERTHERE ARE SEVERAL PLACES ON THE BACKPLANE, THE AC DISTRIBUTION, AND DC DISTRIBUTION THAT ARE DANGEROUS. BE SURE TO DISCONNECT THE SYSTEM POWER PLUG AND OPEN THE MAIN CIRCUIT BREAKER BEFORE YOU REMOVE ANY PARTS. BE CAUTIOUS WHENEVER POWER IS STILL ON AND COVERS ARE REMOVED. CAUTIONDo not pull out or insert circuit boards while power is ON. CAUTIONDo not operate this unit unless all board covers and frame panels are securely in place. System performance and cooling require this.
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 10-2 Section 10-2 - Why do Periodic Maintenance Section 10-2 Why do Periodic Maintenance 10-2-1 Keeping Records It is good business practice that ultrasound facilities maintain records of periodic and corrective maintenance. The Ultrasound Periodic Maintenance Inspection Certificate provides the customer with documentation that the ultrasound scanner is maintained on a periodic basis. A copy of the Ultrasound Periodic Maintenance Inspection Certificate should be kept in the same room or near the scanner. 10-2-2 Quality Assurance In order to gain accreditation from organizations such as the American College of Radiology (USA), it is the customer’s responsibility to have a quality assurance program in place for each scanner. The program must be directed by a medical physicists, the supervising radiologist/physician or appropriate designee. Routine quality control testing must occur regularly. The same tests are performed during each period so that changes can be monitored over time and effective corrective action can be taken. Testing results, corrective action and the effects of corrective action must be documented and maintained on the site. Your GE service representative can help you with establishing, performing and maintaining records for a quality assurance program. Section 10-3 Maintenance Task Schedule 10-3-1 How often should maintenance tasks be performed? The Maintenance Task Schedule specifies how often your LOGIQ™ 9 should be serviced and what items need attention. It is the customer’s responsibility to ensure the LOGIQ™ 9 periodic maintenance is performed as scheduled in order to retain its high level of safety, dependability and performance. Your GE Service Representative knows your LOGIQ™ 9 best and can provide competent, efficient service. Please contact us for further information and to schedule GE Medical Systems Ultrasound to perform this service for you. The services and intervals shown in the maintenance schedule assumes that you use your LOGIQ™ 9 for an average patient load (10-12 per day) and not use it as a primary mobile unit which is transported between diagnostic facilities. If conditions exist which exceed typical usage and patient load, then it is recommended to increase the periodic maintenance frequencies.
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 10 Periodic Maintenance 10-3 Note 1: These specific tasks are completed during GE performed PMs or any time corrective maintenance is performed by GE. Note 2: May require specialized equipment to complete. Table 10-2 Customer Performed Maintenance Tasks Service at Indicated TimeDailyWeeklyMonthly Per Facilities QA Program Notes Clean Probes•** or before each use Clean Probe Holders • Clean Air Filter•more frequently depending on your environment Inspect AC Mains Cable•Mobile Unit Check Weekly Inspect Cables and Connectors• Clean Console• Clean Monitor and Touch Panel• Inspect Wheels, Casters, brakes and Swivel Locks•Mobile Unit Check Daily Check Control Panel Movement •Mobile Unit Check Daily Console Leakage Current ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Peripheral Leakage Current ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Surface Probe Leakage Current ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Endocavity Probe Leakage Current ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Transesphongeal Probe Leakage Current ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Surgical Probe Leakage Current ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Measurement Accuracy ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Probe/Phantom ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program Functional ChecksSee Note 1 See Note 2also after corrective maintenance or as required by your facilities QA program
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 10-4 Section 10-4 - Tools Required Section 10-4 Tools Required 10-4-1 Standard GE Tool Kit The following is a description of the “Standard” GE tool kit in the USA. Not all tools are required for PMs. Table 10-3 Overview of GE-1 Tool Kit Contents Tool IDDescriptionTool IDDescription 9-45358 Pliers Retaining Ring 9-XL9971MM Xcelite-hex Blade 1.27mm 9-4078 Scribe 9-XL9972MM Xcelite-hex Blade 1.5mm 9-44572 Wrench Open End 3/8 - 7/16 9-XL9973MM Xcelite-hex Blade 2 mm 9-44579Wrench Open End 1/2 - 9/169-XL9974MMXcelite-hex Blade 2.5mm 9-44579Wrench Open End 1/2 - 9/169-XL9975MMXcelite-hex Blade 3mm 9-45385Pliers, Arc Joint 7 inch9-XL9976MMXcelite-hex Blade 4mm 9-45378 Pliers, Slip Joint 9-XL9977MM Xcelite-hex Blade 5mm 9-4518 Pliers, Long Nose, Miniature 9-XL991CM Handle 9-4518 Pliers, Long Nose, Miniature C2356E Screw starter - Kedman Quick Wedge 9-44776Ignition Wrench Set, 10 pc.BLBOBox - 18 Compartment 9-44601Wrench, Adj., 4 inchDWL4283TBox - 5 Compartment 9-4151Screwdriver, Blade, Stubby9-41322Pickup Tool, Claw type 9-41421 Screwdriver, Blade, Pocket clip 9-6757 6 pc Needle File Set 9-41594 Screwdriver, Blade 1/8 in. x 4 in. 9-9487 Utility Knife 9-41581 Screwdriver, Blade 3/16 in. x 4 in. 9-45341 Pliers Vice Grip 10 inch 9-3945120 Steel Tape, locking Spring load9-3001 Xacto Pen Knife 9-GH807Ratchet, Offset, Slotted9-HT62002Solder Aid, Fork and Hook 68-412Ratchet, Offset, Phillips9-4099Mirror, Round, Telescoping 9-GH130 Tapered Reamer 9-GH3001 Steel Rule Decimal 6 inch 9-41584 Screwdriver, slotted 1/4 in.X 6 in. 9-GH300ME Steel Rule Metric 6 inch 9-4118 Screwdriver, Phillips #2, Stubby 9-XL9920 Xcelite-hex Blade.050 inch 9-41293Screwdriver, Phillips #09-XL9921Xcelite-hex Blade 1/16 inch 9-41294Screwdriver, Phillips #19-XL9922Xcelite-hex Blade 5/16 inch 9-41295Screwdriver, Phillips #29-XL9923Xcelite-hex Blade 3/32 inch 9-46677 Hex Keys, 20 pc., Metric 9-XL9924 Xcelite-hex Blade 1/8 inch 9-34701 1/4 in. Standard.Socket set (19 pc) 9-XL9925 Xcelite-hex Blade 5/32 inch 9-43499 1/2 inch Socket 1/4 inch drive 9-XL9926 Xcelite-hex Blade 3/16 inch 9-4355Flex Spinner9-XL99764Xcelite-hex Blade 7/64 9-43523 Breaker9-XL99964Xcelite-hex Blade 9/64 9-435316 inch Ext.9-XLM60Mini-screwdriver kit
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 10 Periodic Maintenance 10-5 9-65283 Case 8.5 in. x 4.5 in. x 2 in. Deep 9-45072 Pliers 6 inch Diagonal 9-46696 Hex Keys 9-XL100X Wire Stripper/Cutter 5 inch - 100X 9-39829 Torpedo Level, Magnetic 9-XL87CG Pliers - very fine needle nose-87CG 9-38461Hammer, Ball Peen, 4 oz9-WEWDT-07Weller-Soldering-Replacement Tip(1) 9-4280Universal Joint 1/4 inch9-WS175-EWiss - Surgical Scissors 9-WEW60P3Weller - Soldering Iron, 3 wireKH174Hemostat 5 inch Straight 9-WECT5B6 Weller - Soldering Iron Tip KH175 Hemostat 5 inch curved 9-WEWDP12 Weller - Desoldering Pump 9-Z9480121 Alignment tool (red) 93383 Flashlight Mini-Mag Lite (AAA Bat.) 9-GH408Tweezers 21576Brush - Bristle 9-4516Pliers 4 1/4 inch Diagonal Table 10-4 Overview of GE-2 Tool Kit Contents GE-2 Sears Kit (#99034) Tool IDDescriptionTool IDDescription 9-45381 Pliers, Arc Joint 9 1/2 inch 9-44067 Socket 1 1/16 in. for 1/2 in. drive 9-45092 Pliers, Linesman 8 1/2 inch 9-42679 Socket 10MM Hex for 1/2 in. drive (2273333) 9-42882 Punch, Pin 3/32 inch 9-44262 Extension 10 inch for 1/2 in. drive (2273405) 9-42884Punch, Pin 5/32 inch9-42583/8 inch to 1/2 inch Adapter 9-42886Punch, Pin 1/4 inch9-343743/8 inch Metric Socket Set - 12 PT 9-42973Cold Chisel 1/2 inch9-4431116mm Socket 12 pt. 9-GH77 Center Punch Automatic 9-33485 Metal Socket Tray 9-GH890 File Handle, Adj. 9-33484 Metal Socket Tray 9-31276 File, Round, Bastard 8 inch 9-33484 Metal Socket Tray 9-31277 File, Half Round, Bastard 8 inch9-52068Tap and Drill Set 9-31263File, Flat Mill 8 inch9-52722#6 Tap 21045CClose Quarter Saw9-52723#8 Tap 9-44604 Wrench, Adj 10 inch High Speed Drill Set 9-41587 Screwdriver 5/16 inch x 8 inch #36 Drill 9-41586 Screwdriver, Stubby 5/16 inch #29 Drill 9-GH19512Countersink 1/2 inch9-440463/8 inch Socket Set 9-4474112 PC Combination Wrench Set Table 10-3 Overview of GE-1 Tool Kit Contents (Continued) Tool IDDescriptionTool IDDescription
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 10-6 Section 10-4 - Tools Required 10-4-2 Special Tools, Supplies and Equipment 10-4-2-1 Specific Requirements for Periodic Maintenance See Chapter 7 Table 10-5 Overview of Requirements for Periodic Maintenance Tool Part NumberComments Digital Volt Meter (DVM) Electric Safety Analyzer DALE 600 46-285652G1 For 120V Unit Electric Safety Analyzer DALE 600E46-328406G2 For 220V Units Leakage Current Ultrasound Kit2113015For 120V and 220V Units Anti Static Kit 46–194427P231 46–194427P279 46–194427P369 46–194427P373 46–194427P370Kit includes anti–static mat, wrist strap and cables for 200 to 240 V system 3M #2204 Large adjustable wrist strap 3M #2214 Small adjustable wrist strap 3M #3051 conductive ground cord Anti Static Vacuum Cleaner46–194427P278 46–194427P279120V 230V Air FilterSection 9-16 air intake Safety Analyzer 46–285652G1 DALE 600 KIT (or equivalent) for electrical tests SVHS VCR CassetteE7010GG E7010GF60 minute 120 minute SVHS VCR Head CleanerSee VCR user manual for requirements 3.5” MOD MEDIA E8381AA E8381ABblank 128 M disk blank 230 M disk 5.25” MOD Media 3.5” MOD Media Cleaner 2117811 cleans the diskettes 5.25” MOD Media Cleaner cleans the diskettes 3.5” MOD Head Cleaner Kit 2148392 cleans the drive heads 5.25” MOD Head Cleaner Kitcleans the drive heads QIQ PhantomE8370RBRMI Grayscale Target Model 403GS CD-RW MediaFor LOGIQ™ 9 ??? B/W Printer Cleaning Sheet See printer user manual for requirements Color Printer Cleaning Sheet See printer user manual for requirements Disposable Gloves