    of 570
    							GE MEDICAL SYSTEMS PROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
    Chapter 9 Renewal Parts 9-39
    Section 9-18
    Voice Scan
    Figure 9-24  Voice Scan Replacement Parts
    Table 9-21    Voice Scan
    Item Part NamePart NumberDescriptionQtyFRU
    750Wireless Receiver 2383770 1 1
    751Battery Eliminator Cable 2383769 1 1
    752Audio to USB Adapter 2383765 1 1
    753Audio Cable from Receiver238376811
    754Power Cable for Receiver238376711
    755Tray for Wireless Receiver237759912
    756Foam - Wireless Receiver Bottom 2377600 1 2
    757Foam - Wireless Receiver Top 2377601 1 2
    758AC Adapter - 9V, 1.1A 2384314 1 1
    759USB Extension Cable238444911
    760Battery Charger238377511
    761Battery - 9V NiMH238377631
    762Microphone 2383779 Over the ear style. 1 1
    763USB Headset 2386172 1 1
    764Wireless Microphone Care Kit 2386142 1 1
    765Beltpack Transmitter - Wireless238377311
    766Adapter Kit - 240Vac239011711
    760
    761
    762
    765
    766 
    						
    							GE MEDICAL SYSTEMSPROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
    9-40 Section 9-19 - Customer Documentation
    Section 9-19
    Customer Documentation
     
    Figure 9-25  Customer Documentation Package
    Table 9-22    Documentation Box Contents
    ItemPart NamePart NumberDescriptionQtyFRU
    Customer Documentation Collector2376865 Includes items 800-808 1 N
    800LOGIQ™ 9 Customer Documentation 
    CD2353630-200All available documents in PDF format. Can be 
    viewed on the scanner or any PC Includes service 
    and user manuals.1N
    801
    LOGIQ™ 9 Installation Manual2301715-100Basic Installation and how to view documents on the 
    CD1N
    802LOGIQ™ 9 Quick Guide2309820-100Basic scanner operation1N
    803LOGIQ™ 9 Release Notes2320595-100R2.1.0 Software1N
    804LOGIQ™ 9 Release Notes Addendum2376420-100R2.1.1 Addendum1N
    805
    LOGIQ™ 9 Quick Card #12309821-100 1 N
    806
    LOGIQ™ 9 EFBW Quick Card2323180-100 EFBW Procedures 1 N
    807LOGIQ™ 9 AUA vs. CUA (linear 
    regression)2323181-100 AUA vs. CUA 1 N
    808LOGIQ™ 9 Op Panel P-Key Labels2376993Labels for Print Key assignments1N 
    						
    							GE MEDICAL SYSTEMS PROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
    Chapter 9 Renewal Parts 9-41
    Section 9-20
    Probes
    Figure 9-26   LOGIQ™ 9 Probes
    Table 9-23    Available Probes
    ItemPart NamePart NumberDescriptionQtyFRU
    9013.5C 2296158 H4901PE - PDI 1
    902M7C 2294514 H4901PG - Hino 1
    903E8C 2294641 H4901PM - Hino 1
    9047L2294521H4901PH - Hino1
    90510L2294523H4901PJ - Hino1
    906M12L2294511H4901PK - Hino1
    907i12L 2264883 H4901PL - PDI 1
    9084S 2295658 H4901PB - PDI 1
    90910S 2298589 H4901PC - PDI 1
    9108C2348094Q1 2003 Release1
    911TCD 3S2323337T3308MC1
    9123.5CS2051858H40412LK1
    913Probe Latching Mechanism 2130769 Large round blue locking knob used on some probes 1
    901902903904905906
    908909907910911912 
    						
    							GE MEDICAL SYSTEMSPROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
    9-42 Section 9-20 - Probes
    This page was intentionally left blank. 
    						
    							GE MEDICAL SYSTEMS PROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
    Chapter 10 Periodic Maintenance 10-1
    Chapter 10
    Periodic Maintenance
    Section 10-1
    Overview
    10-1-1 Purpose of Chapter 10
    This chapter describes Periodic Maintenance (PM) and customer performed tasks on the scanner and 
    peripherals. These procedures are intended to maintain the quality of the ultrasound systems 
    performance. Read this chapter completely and familiarize yourself with the procedures before 
    performing a task.
     
    Table 10-1    Contents in Chapter 10
    SectionDescriptionPage Number
    10-1
    Overview10-1
    10-2
    Why do Periodic Maintenance10-2
    10-3
    Maintenance Task Schedule10-2
    10-4Tools Required10-4
    10-5System Periodic Maintenance10-7
    10-6Using a Phantom10-12
    10-7
    Electrical Safety Tests10-12
    10-8
    When Theres Too Much Leakage Current...10-28
    PM INSPECTION Certificate10-29
    CAUTIONPractice good ESD prevention. Wear an anti–static strap when handling electronic parts and 
    even when disconnecting/connecting cables.
    DANGERTHERE ARE SEVERAL PLACES ON THE BACKPLANE, THE AC DISTRIBUTION, 
    AND DC DISTRIBUTION THAT ARE DANGEROUS. BE SURE TO DISCONNECT 
    THE SYSTEM POWER PLUG AND OPEN THE MAIN CIRCUIT BREAKER 
    BEFORE YOU REMOVE ANY PARTS. BE CAUTIOUS WHENEVER POWER IS 
    STILL ON AND COVERS ARE REMOVED.
    CAUTIONDo not pull out or insert circuit boards while power is ON.
    CAUTIONDo not operate this unit unless all board covers and frame panels are securely in place. System 
    performance and cooling require this. 
    						
    							GE MEDICAL SYSTEMSPROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
    10-2 Section 10-2 - Why do Periodic Maintenance
    Section 10-2
    Why do Periodic Maintenance
    10-2-1 Keeping Records
    It is good business practice that ultrasound facilities maintain records of periodic and corrective 
    maintenance. The Ultrasound Periodic Maintenance Inspection Certificate provides the customer with 
    documentation that the ultrasound scanner is maintained on a periodic basis.
    A copy of the Ultrasound Periodic Maintenance Inspection Certificate should be kept in the same room 
    or near the scanner.
    10-2-2 Quality Assurance
    In order to gain accreditation from organizations such as the American College of Radiology (USA), it 
    is the customer’s responsibility to have a quality assurance program in place for each scanner. The 
    program must be directed by a medical physicists, the supervising radiologist/physician or appropriate 
    designee.
    Routine quality control testing must occur regularly. The same tests are performed during each period 
    so that changes can be monitored over time and effective corrective action can be taken.
    Testing results, corrective action and the effects of corrective action must be documented and 
    maintained on the site.
    Your GE service representative can help you with establishing, performing and maintaining records for 
    a quality assurance program.
    Section 10-3
    Maintenance Task Schedule
    10-3-1 How often should maintenance tasks be performed?
    The Maintenance Task Schedule specifies how often your LOGIQ™ 9 should be serviced and what 
    items need attention. It is the customer’s responsibility to ensure the LOGIQ™ 9 periodic maintenance 
    is performed as scheduled in order to retain its high level of safety, dependability and performance.
    Your GE Service Representative knows your LOGIQ™ 9 best and can provide competent, efficient 
    service. Please contact us for further information and to schedule GE Medical Systems Ultrasound to 
    perform this service for you.
    The services and intervals shown in the maintenance schedule assumes that you use your LOGIQ™ 9 
    for an average patient load (10-12 per day) and not use it as a primary mobile unit which is transported 
    between diagnostic facilities.
    If conditions exist which exceed typical usage and patient load, then it is recommended to increase the 
    periodic maintenance frequencies. 
    						
    							GE MEDICAL SYSTEMS PROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
    Chapter 10 Periodic Maintenance 10-3
    Note 1: These specific tasks are completed during GE performed PMs or any time corrective 
    maintenance is performed by GE.
    Note 2: May require specialized equipment to complete. Table 10-2 Customer Performed Maintenance Tasks
    Service at Indicated TimeDailyWeeklyMonthly
    Per Facilities 
    QA Program
    Notes
    Clean Probes•** or before each use
    Clean Probe Holders
    •
    Clean Air Filter•more frequently depending on 
    your environment
    Inspect AC Mains Cable•Mobile Unit Check Weekly
    Inspect Cables and Connectors•
    Clean Console•
    Clean Monitor and Touch Panel•
    Inspect Wheels, Casters, brakes and 
    Swivel Locks•Mobile Unit Check Daily
    Check Control Panel Movement
    •Mobile Unit Check Daily
    Console Leakage Current ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Peripheral Leakage Current ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Surface Probe Leakage Current ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
     Endocavity Probe Leakage 
    Current ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Transesphongeal Probe Leakage 
    Current ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Surgical Probe Leakage 
    Current ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Measurement Accuracy ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Probe/Phantom ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program
    Functional ChecksSee Note 1
    See Note 2also after corrective 
    maintenance or as required by 
    your facilities QA program 
    						
    							GE MEDICAL SYSTEMSPROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
    10-4 Section 10-4 - Tools Required
    Section 10-4 
    Tools Required
    10-4-1 Standard GE Tool Kit
    The following is a description of the “Standard” GE tool kit in the USA. Not all tools are required for PMs.
    Table 10-3     Overview of GE-1 Tool Kit Contents 
    Tool IDDescriptionTool IDDescription
    9-45358 Pliers Retaining Ring 9-XL9971MM Xcelite-hex Blade 1.27mm
    9-4078 Scribe 9-XL9972MM Xcelite-hex Blade 1.5mm
    9-44572 Wrench Open End 3/8 - 7/16 9-XL9973MM Xcelite-hex Blade 2 mm
    9-44579Wrench Open End 1/2 - 9/169-XL9974MMXcelite-hex Blade 2.5mm
    9-44579Wrench Open End 1/2 - 9/169-XL9975MMXcelite-hex Blade 3mm
    9-45385Pliers, Arc Joint 7 inch9-XL9976MMXcelite-hex Blade 4mm
    9-45378 Pliers, Slip Joint 9-XL9977MM Xcelite-hex Blade 5mm
    9-4518 Pliers, Long Nose, Miniature 9-XL991CM Handle
    9-4518 Pliers, Long Nose, Miniature C2356E Screw starter - Kedman Quick Wedge
    9-44776Ignition Wrench Set, 10 pc.BLBOBox - 18 Compartment 
    9-44601Wrench, Adj., 4 inchDWL4283TBox - 5 Compartment
    9-4151Screwdriver, Blade, Stubby9-41322Pickup Tool, Claw type
    9-41421 Screwdriver, Blade, Pocket clip 9-6757 6 pc Needle File Set
    9-41594 Screwdriver, Blade 1/8 in. x 4 in. 9-9487 Utility Knife
    9-41581 Screwdriver, Blade 3/16 in. x 4 in. 9-45341 Pliers Vice Grip 10 inch
    9-3945120 Steel Tape, locking Spring load9-3001 Xacto Pen Knife
    9-GH807Ratchet, Offset, Slotted9-HT62002Solder Aid, Fork and Hook
    68-412Ratchet, Offset, Phillips9-4099Mirror, Round, Telescoping
    9-GH130 Tapered Reamer 9-GH3001 Steel Rule Decimal 6 inch
    9-41584 Screwdriver, slotted 1/4 in.X 6 in. 9-GH300ME Steel Rule Metric 6 inch
    9-4118 Screwdriver, Phillips #2, Stubby 9-XL9920 Xcelite-hex Blade.050 inch
    9-41293Screwdriver, Phillips #09-XL9921Xcelite-hex Blade 1/16 inch
    9-41294Screwdriver, Phillips #19-XL9922Xcelite-hex Blade 5/16 inch
    9-41295Screwdriver, Phillips #29-XL9923Xcelite-hex Blade 3/32 inch
    9-46677 Hex Keys, 20 pc., Metric 9-XL9924 Xcelite-hex Blade 1/8 inch
    9-34701 1/4 in. Standard.Socket set (19 pc) 9-XL9925 Xcelite-hex Blade 5/32 inch
    9-43499 1/2 inch Socket 1/4 inch drive 9-XL9926 Xcelite-hex Blade 3/16 inch
    9-4355Flex Spinner9-XL99764Xcelite-hex Blade 7/64
    9-43523 Breaker9-XL99964Xcelite-hex Blade 9/64
    9-435316 inch Ext.9-XLM60Mini-screwdriver kit 
    						
    							GE MEDICAL SYSTEMS PROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
    Chapter 10 Periodic Maintenance 10-5
    9-65283 Case 8.5 in. x 4.5 in. x 2 in. Deep  9-45072 Pliers 6 inch Diagonal
    9-46696 Hex Keys 9-XL100X Wire Stripper/Cutter 5 inch - 100X
    9-39829 Torpedo Level, Magnetic 9-XL87CG Pliers - very fine needle nose-87CG
    9-38461Hammer, Ball Peen, 4 oz9-WEWDT-07Weller-Soldering-Replacement Tip(1)
    9-4280Universal Joint 1/4 inch9-WS175-EWiss - Surgical Scissors
    9-WEW60P3Weller - Soldering Iron, 3 wireKH174Hemostat 5 inch Straight 
    9-WECT5B6 Weller - Soldering Iron Tip KH175 Hemostat 5 inch curved
    9-WEWDP12 Weller - Desoldering Pump 9-Z9480121 Alignment tool (red)
    93383 Flashlight Mini-Mag Lite (AAA Bat.)
    9-GH408Tweezers
    21576Brush - Bristle
    9-4516Pliers 4 1/4 inch Diagonal
    Table 10-4     Overview of GE-2 Tool Kit Contents 
    GE-2 Sears Kit (#99034) 
    Tool IDDescriptionTool IDDescription
    9-45381 Pliers, Arc Joint 9 1/2 inch 9-44067 Socket 1 1/16 in. for 1/2 in. drive
    9-45092 Pliers, Linesman 8 1/2 inch 9-42679 Socket 10MM Hex for 1/2 in. drive (2273333) 
    9-42882 Punch, Pin 3/32 inch 9-44262 Extension 10 inch for 1/2 in. drive (2273405)
    9-42884Punch, Pin 5/32 inch9-42583/8 inch to 1/2 inch Adapter
    9-42886Punch, Pin 1/4 inch9-343743/8 inch Metric Socket Set - 12 PT
    9-42973Cold Chisel 1/2 inch9-4431116mm Socket 12 pt.
    9-GH77 Center Punch Automatic 9-33485 Metal Socket Tray
    9-GH890 File Handle, Adj. 9-33484 Metal Socket Tray
    9-31276  File, Round, Bastard 8 inch  9-33484 Metal Socket Tray
    9-31277 File, Half Round, Bastard 8 inch9-52068Tap and Drill Set
    9-31263File, Flat Mill 8 inch9-52722#6 Tap
    21045CClose Quarter Saw9-52723#8 Tap
    9-44604 Wrench, Adj 10 inch High Speed Drill Set
    9-41587 Screwdriver 5/16 inch x 8 inch #36 Drill
    9-41586 Screwdriver, Stubby 5/16 inch  #29 Drill
    9-GH19512Countersink 1/2 inch9-440463/8 inch Socket Set
    9-4474112 PC Combination Wrench Set
    Table 10-3     Overview of GE-1 Tool Kit Contents (Continued)
    Tool IDDescriptionTool IDDescription 
    						
    							GE MEDICAL SYSTEMSPROPRIETARY TO GE
    D
    IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
    10-6 Section 10-4 - Tools Required
    10-4-2 Special Tools, Supplies and Equipment
    10-4-2-1 Specific Requirements for Periodic Maintenance
     See Chapter 7
    Table 10-5     Overview of Requirements for Periodic Maintenance
    Tool Part NumberComments
    Digital Volt Meter (DVM)
    Electric Safety Analyzer DALE 600 46-285652G1 For 120V Unit
    Electric Safety Analyzer DALE 
    600E46-328406G2 For 220V Units
    Leakage Current Ultrasound Kit2113015For 120V and 220V Units
    Anti Static Kit
    46–194427P231
    46–194427P279
    46–194427P369
    46–194427P373
    46–194427P370Kit includes anti–static mat, wrist strap and cables for 200 to 240 
    V system
    3M #2204 Large adjustable wrist strap
    3M #2214 Small adjustable wrist strap
    3M #3051 conductive ground cord
    Anti Static Vacuum Cleaner46–194427P278
    46–194427P279120V
    230V
    Air FilterSection 9-16
     air intake
    Safety Analyzer 46–285652G1
    DALE 600 KIT (or equivalent) for electrical tests
    SVHS VCR CassetteE7010GG
    E7010GF60 minute
    120 minute
    SVHS VCR Head CleanerSee VCR user manual for requirements
    3.5” MOD MEDIA
    E8381AA
    E8381ABblank 128 M disk
    blank 230 M disk
    5.25” MOD Media
    3.5” MOD Media Cleaner 2117811
     cleans the diskettes
    5.25” MOD Media Cleaner
    cleans the diskettes
    3.5” MOD Head Cleaner Kit  2148392
     cleans the drive heads
    5.25” MOD Head Cleaner Kitcleans the drive heads
    QIQ PhantomE8370RBRMI Grayscale Target Model 403GS
    CD-RW MediaFor LOGIQ™ 9 ???
    B/W Printer Cleaning Sheet
    See printer user manual for requirements
    Color Printer Cleaning Sheet
    See printer user manual for requirements
    Disposable Gloves 
    						
    All GE manuals Comments (0)

    Related Manuals for GE Logiq 9 Service Manual