GE Logiq 9 Service Manual
Have a look at the manual GE Logiq 9 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 8 Replacement Procedures 8-33 8-5-6 Loading Software It may be a good idea to load software before replacing the covers. Refer to loading Base Image software and loading Applications software. 1.) Plug in the power cable to the system, connect the system to the AC outlet and turn on the circuit breaker. 2.) Power up the system to begin the software load. 8-5-7 Replace Covers 1.) With the software load complete and verified, replace the BEP Cover. 2.) Replace the system right side cover.
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 8-34 Section 8-6 - BEP CD-RW Drive Replacement Procedure (BEP 2.x and above only) Section 8-6 BEP CD-RW Drive Replacement Procedure (BEP 2.x and above only) 8-6-1 Manpower One person, 1 hour + travel 8-6-2 Tools Phillips screwdriver 8-6-3 Preparations (click here to view the cover removal video) 1.) Power Down/Shutdown the system as described in Section 4-3-2 on page 4-3. 2.) Remove the left- and/or right-side covers as shown in Section 8-2-2 on page 8-5. 3.) Remove the front cover as shown in Section 8-2-5 on page 8-9. 8-6-4 CD-RW Drive Removal Procedure NOTE: Mounting hardware may vary in size from M3 to 4-40 threads. Hardware length may seem the same but in fact may be different and very critical. ALWAYS keep track of EXACTLY where each screw was removed so that it is returned to the same place on re-assembly. 1.) Remove the side cover from the BEP. Carefully disconnect the cover fan power cable and set the cover aside. 2.) Disconnect the Power, IDE and Audio cables from the back of the CD-RW drive. 3.) Remove the one screw attaching the side of the CD-RW Drive as shown in Figure 8- 34 on page 8-35 .Figure 8-33 BEP CD-RW Connections Audio Connection IDE Connection - Large Ribbon Cable Power Connection
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 8 Replacement Procedures 8-35 8-6-4 CD-RW Drive Removal Procedure (cont’d) 4.) Peel back the adhesive trim as shown in Figure 8-35 on page 8-35 . Figure 8-34 CD-RW Side Screw Figure 8-35 BEP Front Adhesive Trim
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 8-36 Section 8-6 - BEP CD-RW Drive Replacement Procedure (BEP 2.x and above only) 8-6-4 CD-RW Drive Removal Procedure (cont’d) 5.) Remove the two screws in the front of the CD-RW drive as shown in Figure 8-35 on page 8-35 . 6.) Slide the CD-RW drive out the front of the BEP as shown in Figure 8-36 on page 8-36 . Figure 8-36 CD-RW Removal
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 8 Replacement Procedures 8-37 8-6-5 CD-RW Drive Replacement Procedure 1.) Insert the new CD-RW Drive into the drive bay and secure it in the front with the two screws previously removed. refer to Figure 8-35 on page 8-35 . 2.) Attach the one screw to the side of the CD-RW Drive through the rack. refer to Figure 8- 34 on page 8-35 . 3.) Attach the Power, IDE and Audio cables to the back of the CD-RW drive. Pay attention to the orientation of the guide pin on the IDE Cable connector and the missing pin on the IDE connection of the CD-RW Drive. 4.) Ensure all cables are properly arranged and secure.Figure 8-37 IDE Ribbon Connector IDE Guide Pin
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 8-38 Section 8-6 - BEP CD-RW Drive Replacement Procedure (BEP 2.x and above only) 8-6-6 CD-RW Drive Replacement Procedure 5.) Connect the cover fan power cable and replace the side cover from the BEP. NOTE: When replacing the BEP Cover, ensure that you start it at the bottom to get the cover lip between the BEP chassis and AC transformer cover. Slide it forward and secure it. 6.) Replace the front cover as shown in Section 8-2-5 on page 8-9. 7.) Replace the left- and/or right-side covers as shown in Section 8-2-2 on page 8-5. 8.) If required, Power On/Boot-up the system as described in Section 4-3-1 on page 4-2. 9.) Check CD-RW operation.Figure 8-38 BEP Cover Installation Tip
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 8 Replacement Procedures 8-39 Section 8-7 BEP MOD Replacement Procedure (BEP 2.x and above only) 8-7-1 Manpower One person, 1 hour + travel 8-7-2 Tools Phillips screwdriver 8-7-3 Preparations (click here to view the cover removal video) 1.) Power Down/Shutdown the system as described in Section 4-3-2 on page 4-3. 2.) Remove the left- and/or right-side covers as shown in Section 8-2-2 on page 8-5. 3.) Remove the front cover as shown in Section 8-2-5 on page 8-9. 8-7-4 MOD Drive Removal Procedure NOTE: Mounting hardware may vary in size from M3 to 4-40 threads. Hardware length may seem the same but in fact may be different and very critical. ALWAYS keep track of EXACTLY where each screw was removed so that it is returned to the same place on re-assembly. 1.) Remove the side cover from the BEP. Carefully disconnect the cover fan power cable and set the cover aside. 2.) The MOD is enclosed in a metal case. The power connector will have to be unplugged at the power supply connectors. The IDE Cable will have to be unplugged from the CD-RW Drive and the Motherboard. See Figure 8-43 on page 8-41 for reference. 3.) Remove the one screw attaching the side of the MOD as shown in Figure 8-40 on page 8-40 . Figure 8-39 BEP Motherboard IDE Connection
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 8-40 Section 8-7 - BEP MOD Replacement Procedure (BEP 2.x and above only) 8-7-4 MOD Drive Removal Procedure (cont’d) 4.) Peel back the adhesive trim as shown in Figure 8-41 on page 8-40 . Figure 8-40 MOD Side Screw Figure 8-41 BEP Front Adhesive Trim
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 8 Replacement Procedures 8-41 8-7-4 MOD Drive Removal Procedure (cont’d) 5.) Remove the two screws in the front of the MOD drive as shown in Figure 8-42 on page 8-41 . 6.) Slide the MOD out the front of the BEP as shown in Figure 8-42 on page 8-41 . 7.) Remove the four screws, two on each side, to remove the top cover and side rails from the MOD case.Figure 8-42 MOD Removal Figure 8-43 MOD with Case Cover Off
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 8-42 Section 8-7 - BEP MOD Replacement Procedure (BEP 2.x and above only) 8-7-4 MOD Drive Removal Procedure (cont’d) 8.) Remove the power and IDE Cables from the MOD. Refer to Figure 8-45 on page 8-42 . 9.) Refer to Figure 8-45 on page 8-42 and Figure 8-46 on page 8-43 , go through the side of the MOD case to remove the four screws holding the MOD to the case.Figure 8-44 MOD Rails and Top Cover Figure 8-45 MOD Power and IDE Connections