CO Line - Incoming Ringing Assignment 2-81 Features and Operation Seize Timer Description The Seize Timer option allows the user to adjust the Seize Timer on a per CO Line basis. The Seize Timer is used on ground start type trunks. This Seize Timer is a lead filter timer. The CO must provide ground at the tip lead for longer than this timer in order for the system to recognize it. Programming Steps 1. Press the SEIZE TIMER Button (FLASH 40, Page C, Button #7) in the flexible button field. The following message displays: 2. Enter a valid number on the dial pad which corresponds to 000–255 (100 ms to 2.55 seconds). 3. Press the HOLD button to save the entry. A confirmation tone heard and the display updates. DEFAULT … Seize Timer is set for 0.1 seconds. Tra n s m it Vo l u m e Description Up to ten volume levels are available for each CO Line in the system. Programming Steps 1. Press FLASH and dial [40]. The following message displays: 2. Enter a valid number for the range of lines being programmed. If only one line is being programmed, enter that number twice (001 001). 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible Button #19 (Page A) is lit. SEIZE TIMER 000-255 010 Do NOT adjust this option without consulting Technical Support first. The default s e t t i n g s w e r e s e t t o a p p l y t o m o s t a p p l i c a t i o n s . H a v e t h e dB r e a d i n g s o n a l l C O l i n e s available when calling Technical Support. CO LINE ATTRIBUTES SELECT A CO LINE RANGE If HOLD is pressed without entering a CO range, ALL CO lines are selected.
2-82 CO Line Loop and Pool Buttons Features and Operation 4. Press the Page B flexible button (Button #20). The following message displays: XXX-XXX = CO Line Range 5. Press the TRANSMIT VOLUME flexible button (Button #4). The following message displays: 6. Enter a valid number (0-9) for the desired volume level. 7. When the desired level is selected, press HOLD to complete the entry. A confirmation tone sounds and the display updates. DEFAULT … All CO lines are programmed for level 5 (0 dB). CO Line Loop and Pool Buttons Description A station not having a direct appearance for a CO line receives incoming CO calls and transferred CO calls under the LOOP button. Only one call at a time can be connected to a keyset on the LOOP button. If more than one LOOP button is on a key set, the LOOP buttons may be conferenced together. If all programmed LOOP buttons on a keyset are busy or have a CO call on hold, the party attempting to transfer a CO line to that station receives a busy tone and cannot transfer the call to that station. If a transfer is attempted, the CO line recalls the initiator immediately. CO lines are also presented to a Loop when dialing out using LCR or when using speed dial to dial out and the line chosen does not appear on the key station. The Pool Group feature is used primarily to access CO lines that do not appear on a station, so that outgoing calls may be made. Pooled group keys are associated to CO line groups and may be programmed for use on any of the flexible buttons. CO lines are accessed in descending order of priority starting with the highest numbered available (not busy) CO line in a CO line group. Stations may have as many POOL buttons as there are CO line groups. Multiple POOL buttons for the same group are also allowed. XXX - XXX PAGE B ENTER BUTTON NUMBER TRANSMIT VOLUME 0-9 0 DB [0] -15 dB [5] 0 dB [1] -12 dB [6] +3 dB [2] -9 dB [7] +6 dB [3] -6 dB [8] +7.5 dB [4] -3 dB [9] +9.0 dB
C O L in e Loo p a n d Po ol Bu tto ns 2-83 Features and Operation Use Flash 50 programming when you want to modify a range of stations’ attributes using fixed station numbers. Use Flash 51 programming to modify a single station’s attributes using a flexible station number. Programming Steps 1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of the following messages displays: 2. Enter the range of fixed station numbers (100-149) to be programmed. If only one station is being programmed, enter that number twice, e.g., [100 100]. -or- Enter a valid flexible number (100-8999) to be programmed. 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 is lit. The display updates to reflect current programming for Page A: 4. Press the CO LOOP POOL flexible button (Button #17). The following message displays: 5. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disable [1] = Enable 6. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … CO Loop Pool is disabled. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers STATION ATTRIBUTES SELECT A STATION RANGEENTER STATION NUMBER If HOLD is pressed without entering a station range, ALL stations are selected. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers XXX - XXX PAGE A ENTER BUTTON NUMBERSXXX PAGE A ENTER BUTTON NUMBER XXX-XXX = fixed station range XXX = 3- or 4-digit flexible number CO LOOP POOL FLEX 0-1 DISABLED
2-84 CO Line Loop and Pool Buttons Features and Operation Operation To make a Loop button: 1. Press the SPEED button twice. 2. Press the desired flexible button. 3. Dial [89]. 4. Press HOLD. Conditions » Only one station at a time can be programmed when using a flexible station number. » When in Flash 51 programming, if you press HOLD without specifying a flexible number to be programmed, you will get the station that is in port/station 100. In-Use Hold (I-Hold) Flash Rate Description The In Use-Hold (I-Hold) flash rate is the rate at which a CO Line button or Loop button flashes when a call is placed on In-Use Hold (I-Hold). This flash rate can be programmed to 29 different options identified in the flash rate table. This enables the programmer to customize the key system configuration to desired flash rates. Programming Steps 1. Press the IN-USE HOLD flexible button (FLASH 07, Button #14). The following message displays: 2. Enter a valid number (00-28) on the dial pad to correspond to one of the 29 available options (refer to Table 2-14 on page 2-148). 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. DEFAULT … In-Use Hold (I-Hold) flash rate is set for a Green 60 ipm Flash (17). IN-USE HOLD 00-28 GREEN 60 IPM FLASH
CO Line - Loop Supervision2-85 Features and Operation CO Line - Loop Supervision Description The STS can be programmed to monitor CO lines while on-hold or connected to RAN devices or Voice Mail systems, or in Trunk-to-Trunk connections for disconnect signal provided by the Telco. After a disconnect signal is detected, the STS releases the CO lines and automatically place them back in service. Loop Supervision Programming Description Loop Supervision is used primarily with DISA, Voice Mail / Auto Attendant and with unsupervised conference applications. It lets the system detect when loop current is broken and an outside line is no longer being used. To determine timer value for loop supervision, consult your local central office for type and duration of loop supervision signal. Programming Steps 1. Press FLASH and dial [40]. The following message displays: 2. Enter a valid number for the range of lines being programmed. If only one line is being programmed, enter that number twice (001 001). 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 (Page A) is lit. The following message displays to indicate current programming of that line or group of lines: XXX-XXX = CO Line Range 4. Press the LOOP SUPV flexible button (Button #6). 5. Enter a valid number (1-9) on the dial pad which corresponds to 100-900 ms. (0 = disabled). 6. Press HOLD to save the entry. A confirmation tone sounds and the display updates. DEFAULT … Loop Supervision is set for 400 ms for all CO Lines. CO LINE ATTRIBUTES SELECT A CO LINE RANGE If HOLD is pressed without entering a CO range, ALL CO lines are selected. XXX - XXX PAGE A ENTER BUTTON NUMBER LOOP SUPERVISION 0-9 4
2-86CO Line - Loop Supervision Features and Operation SLT Loop Supervision Programming Description Loop Supervision is used primarily with DISA, Voice Mail / Auto Attendant and with unsupervised conference applications. It lets the system detect when loop current is broken and an outside line is no longer being used. Loop supervision can be disabled on SLT lines so that voice mail ports will drop calls when the outside party hangs up. Programming Steps 1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of the following messages displays: 2. Enter the range of fixed station numbers (100-419) to be programmed. If only one station is being programmed, enter that number twice, e.g., [100 100]. -or- Enter a valid flexible number (100-8999) to be programmed. 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 is lit. The display updates to reflect current programming for Page A: Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers STATION ATTRIBUTES SELECT A STATION RANGEENTER STATION NUMBER If HOLD is pressed without entering a station range, ALL stations are selected. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers XXX - XXX PAGE A ENTER BUTTON NUMBERSXXX PAGE A ENTER BUTTON NUMBER XXX-XXX = fixed station range XXX = 3- or 4-digit flexible number
CO Line - Queue2-87 Features and Operation 4. Press button #21. The display updates to reflect current programming for Page C. 5. Press the SLT SUPERVISION button (Button #7). The following message displays: 6. Dial a valid number [0] to disable or [1] to enable SLT Loop Supervision. 7. Press HOLD to save the entry. DEFAULT … The SLT Loop Supervision setting is [1] (enabled). Conditions » Only one station at a time can be programmed when using a flexible station number. » When in Flash 51 programming, if you press HOLD without specifying a flexible number to be programmed, you will get the station that is in port/station 100. CO Line - Queue Description When all outside lines in a group are busy, stations can be placed in queue awaiting a line in the same group to become available. If a station doesn’t answer the queue signal within 15 seconds, that station is dropped from the queue. A station can queue only one line at a time. Line Queuing Description Stations can be allowed or denied the ability to manually queue for a busy group of CO lines. Even when disabled, stations have automatic LCR queuing privileges. Use Flash 50 programming when you want to modify a range of stations’ attributes using fixed station numbers. Use Flash 51 programming to modify a single station’s attributes using a flexible station number. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers XXX - XXX PAGE C ENTER BUTTON NUMBERSXXX PAGE C ENTER BUTTON NUMBER XXX-XXX = fixed station range XXX = 3- or 4-digit flexible number SLT SUPERVISION 0-1 ENABLED
2-88CO Line - Queue Features and Operation Programming Steps 1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of the following messages displays: 2. Enter the range of fixed station numbers (100-149) to be programmed. If only one station is being programmed, enter that number twice, e.g., [100 100]. -or- Enter a valid flexible number (100-8999) to be programmed. 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 is lit. The display updates to reflect current programming for Page A: 4. Press the QUEUING flexible button (Button #7). The following message displays: 5. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disabled [1] = Enabled 6. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … CO Line Queuing is enabled at all stations. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers STATION ATTRIBUTES SELECT A STATION RANGEENTER STATION NUMBER If HOLD is pressed without entering a station range, ALL stations are selected. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers XXX - XXX PAGE A ENTER BUTTON NUMBERSXXX PAGE A ENTER BUTTON NUMBER XXX-XXX = fixed station range XXX = 3- or 4-digit flexible number LINE QUEUING 0-1 ENABLED
CO Line - Queue2-89 Features and Operation Operation If you wish to be placed on a list waiting for an outside line to become available: 1. Press desired busy OUTSIDE LINE button, -or- Press the POOL button. (Busy tone sounds.) 2. Press the preprogrammed CO LINE QUEUE button (621). 3. Replace handset or press ON/OFF button. To answer a queue: If you hear ringing and an outside line of the line group or a LOOP button you queued onto is rapidly flashing: 1. Lift handset or press ON/OFF button. 2. Press flashing OUTSIDE LINE button or LOOP button to answer. SINGLE LINE TELEPHONE 1. Dial outside line access code. Receive busy tone. 2. Briefly depress and release the hookswitch. 3. Dial [621]. Confirmation tone sounds. Conditions » A LOOP button or direct appearance of the queued line is required. » Only one station at a time can be programmed when using a flexible station number. » When in Flash 51 programming, if you press HOLD without specifying a flexible number to be programmed, you will get the station that is in port/station 100. CO Line Queue Button Flash Rate Description The Line Queue Button flash rate is the rate at which the Line Queue button flashes after queueing onto a busy line. This button flashes when the busy line becomes available. This flash rate can be programmed to 29 different options identified in the flash rate table which enables the programmer to customize the key system configuration to desired flash rates. Programming Steps 1. Press the LINE QUEUE BTN flexible button (FLASH 07, Button #17). 2. Enter a valid number (00-28) on the dial pad to correspond to one of the 29 available options (refer to Table 2-14 on page 2-148). 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. DEFAULT … Line Queue Button flash rate is set for a Red 480 ipm Flutter (08). LINE QUEUE BTN 00-28 RED 480 IPM FLUTTER
2-90CO Line - Ringing Options Features and Operation CO Line - Ringing Options Description When a CO call rings at a busy station, the call rings at the station using a muted ring signal. This option allows a user to receive a reminder ring at their busy station, instead of muted ringing. A reminder ring timer is also available to provide the reminder ring every time the timer expires, as long as the incoming CO line remains connected. Use Flash 50 programming when you want to modify a range of stations’ attributes using fixed station numbers. Use Flash 51 programming to modify a single station’s attributes using a flexible station number. Programming Steps 1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of the following messages displays: 2. Enter the range of fixed station numbers (100-149) to be programmed. If only one station is being programmed, enter that number twice, e.g., [100 100]. -or- Enter a valid flexible number (100-8999) to be programmed. 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 is lit. The display updates to reflect current programming for Page A: Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers STATION ATTRIBUTES SELECT A STATION RANGEENTER STATION NUMBER If HOLD is pressed without entering a station range, ALL stations are selected. Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers XXX - XXX PAGE A ENTER BUTTON NUMBERSXXX PAGE A ENTER BUTTON NUMBER XXX-XXX = fixed station range XXX = 3- or 4-digit flexible number