Home > Toshiba > Communications System > Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							Strata AirLink Systems
    RWIU System Installation
    Strata DK I&M 5/9916-39
    Strata AirLink Systems
     
    Important!For Strata DK40i, if there are 8 handsets, the RWIU can be installed in any of the 
    expansion cabinet slots (15, 16, and 18). If there are 16 handsets, the RWIU must be 
    installed in slot 15 and Slot 16 must be vacant. This system cannot support 24 or 32 
    handsets because of a port limitation.
    Step 4: Install the RWIU/WWIS into the Strata DK
    1. Insert the RWIU (WWIS and components facing right) into the appropriate slot of the Strata 
    DK and apply firm, even pressure to ensure proper mating of connectors.
    CAUTION!Strata DK power must be off before inserting the RWIU.
    2. After installing the RWIU, gently pull the PCB outward. If the connectors are properly seated, 
    a slight resistance is felt.
    Step 5: Run the Cable
    1. Do not exceed these cabling distances between the Base Stations and WWIS for Category 5, 
    24 AWG:
    ©2,000 feet for line power
    ©3,300 feet for local power
    2. Use Category 5 cable. Using a mix of Categories 2, 3, 4, and 5 is acceptable but can effect the 
    total possible cable length.
    Table 16-14 Strata DK424 and DK280 Base and Expansion Cabinet Slot Assignments
    CabinetPhysical
    SlotsVacant
    Slots
    NumberTy p e
    1 DK424 Base 13~1613/14
    1
    1. Slot must be vacant for RWIU handsets 9~16 (2 slot RWIU positions).15/16
    1
    2 DK424 21~2821/22123/24125/261/272/28
    2 DK280 21~2621/22
    123/24125/261
    3 DK424 31~3831/32133/341/352/363
    2. Slot must be vacant for RWIU handsets 17~24 (3 slot RWIU positions).
    3. Slot must be vacant for RWIU handsets 25~32 (4 slot RWIU positions).37/38
    1
    3 DK280 31~3631/32133/341/352/36
    4 DK424 41~4841/42
    143/441/452/4647/481
    4 DK280 41~4641/42143/441/452/46
    5 DK424 51~5851/52
    153/541/552/5657/581
    5 DK280 51~5651/52153/541/552/56
    6 DK424 61~6861/62
    163/641/652/6667/681
    6 DK280 61~6661/62163/641/652/66
    7 DK424 71~7871/72
    173/741/752/7677/781
    7 DK280 Cannot be seventh cabinet 
    						
    							Strata AirLink Systems
    RWIU System Installation
    16-40Strata DK I&M 5/99
    3. Connect one end of each cable into the RJ-45 
    jacks on the RWIU/WWIS (Point B in Figure 
    16-26) and the other end (reversed) into the EMI 
    box (Point A in Figure 16-26). The RJ-45 transmit 
    and receive pins are shown in Figure 16-25.
    4. Connect each end of the other set of cables into 
    the RJ-45 jacks of the EMI box (Point C - To Base 
    Stations in Figure 16-26) and run the opposite end 
    out to the Base Stations.
     
    Figure 16-26 EMI Connections to the RWIU/WWIS
    CAUTION!
    ©Do not use bridge taps between the RWIU and Base Stations because of potential 
    transmission problems.
    ©Do not use current-limiting (fuse style) primary protectors on the transmit and 
    receive pairs between the RWIU and Base Stations. 
    ©Do not connect the RWIU to power at this point.
    Step 6: Determine Base Station Power Supply
    A Base Station can receive input (line) power from the RWIU or an optional local power supply. 
    Using a local power supply increases the distance Base Stations can be located from the RWIU.
    Customers with 220VAC outlets can:
    ©Purchase another power cord to fit the universal connector (three-pronged IEC 320 power 
    inlet) on the power supply
    ©Replace the 110VAC plug on the cable with an appropriate 220VAC plug
    ©Connect a North American 220VAC adapter to the 110VAC plug
    RJ-45
    Transmit
    Receive 12 65 4 3
    3512
    RJ-45 RJ-45 RJ-45
    Figure 16-25 RJ-45 Pin Configuration
    RWIU1A (side)
    WWIS1A (side)
    3724
    1234A BC - 
    To Base Stations
    EMI 
    						
    							Strata AirLink Systems
    RWIU System Installation
    Strata DK I&M 5/9916-41
    Strata AirLink Systems
    Step 7: Connect the Power Supply
    The maximum available PBX power for each RWIU PCB is one amp (+5VDC).
    1. Use the external power supply (see Figure 16-27) to 
    increase the amps for each Base Station.
    The power supply has a -40VDC power connector 
    for direct connection to the RWIU.
    2. Connect to 110VAC power, but do not power on.
    Step 8: Use the Proper Power Factor (PF)
    äCheck the +5VDC PF using Table 16-15 as a 
    reference. Calculation examples are shown in Ta b l e s  
    16-16 and 16-17.
    NoteThe maximum voltages for the RPSU280A 
    Power Supply are 25.0 (+5VDC) and 65.0                
    (-24VDC).
     
    Table 16-15 Strata DK40i and DK424 PCB and Power Supply PFs
    PCB Type+5VDC PF-24VDC PFNotes
    IMDU 0.1 0.16
    PCOU1, 2 1.9 2.0
    PDKU1, 2 0.8 0.3 With 8 DKTs.
    PEKU 1.6 0.7 With 8 EKTs.
    PEPU 1.1 6.5
    PESU 1.5 0.5 With 4 EKTs and 2 SLTs.
    PIOU 2.0 6.5
    PIOU2 1.1 6.5
    PIOUS 0.75 4.0
    RSTU/RSTU2 (-24VDC) 1.4 0.5 With 8 SLTs.
    R40S 0.0 2.8 Does not use +5VDC.
    RATU 1.7 0.3
    RBSS 0.6 0.3
    RBSS2 0.0 0.3 Does not use +5VDC.
    RBSU + RBSS 3.2 0.3
    RBSU 2.5 1.0
    3923
    AC IN
    110VAC
    Power Cord
    DC OUT
    40VDC
    DC OUT OK
    AC/DC OUT
    OK
    DC/DC OUT
    OK
    RWIU - 40 VDC
    Power Connector
    DC IN
    24VDC
    Backup
    Batteries
    Figure 16-27 RWIU Power Supply 
    						
    							Strata AirLink Systems
    RWIU System Installation
    16-42Strata DK I&M 5/99
    RBSU2 0.0 1.0 Does not use +5VDC.
    RBUS 0.0 0.3 Does not use +5VDC.
    RBUU 0.0 1.0 Does not use +5VDC.
    RCIS 0.3 0.1
    RCIU, RCIU2 0.7 0.2
    RCMS 0.6 0.3
    RCOS, RCOS2 1.7 2.0
    RCOU (4 CO) 2.5 2.0
    RCOU + RCOS (8 CO) 3.6 4.0
    RCOU, RCOU2 1.9 2.0
    RCTUA 2.0 1.0
    RCTUB 4.0 1.0
    RCTUBA/BB 4.0 1.9
    RCTUC/D 4.5 1.9
    RCTUE/F 10.0 1.9
    RDDU 2.6 7.0
    RDSU/RDSS (-24VDC) 1.1 0.3 With 4 DKTs and 4 SLTs.
    RDSU + R48S (-48VDC) 1.1 0.5
    RDTU 1.8 1.0
    REMU2/PEMU 1.0 7.5
    RGLU, RGLU2 2.1 2.5
    RMCU 0.7 0.3
    RMDS 0.35 0.16 2400 bps MODEM.
    RPTU 2.6 1.0
    RRCS-12 1.5 1.0
    RRCS-4 0.4 0.3
    RRCS-8 1.0 0.5
    RSIS 0.35 0.15
    RSIU 1.0 0.3
    RSSU 0.7 0.3
    RSTU + R48S (-48VDC) 1.4 1.0 With 8 SLTs.
    RSTU2 4.0 2.3 With 8 MWs.
    RWIU 9.2 0.0 With 8, 16, 24, or 32 handsets. Table 16-15 Strata DK40i and DK424 PCB and Power Supply PFs
     (continued)
    PCB Type+5VDC PF-24VDC PFNotes 
    						
    							Strata AirLink Systems
    RWIU System Installation
    Strata DK I&M 5/9916-43
    Strata AirLink Systems
     
    Step 9: Program the Strata DK
    Important!Do not use a DKT that has an intercom button for Speed Dial programming.
    1. Determine how many handsets, PDKU ports, and available slots are required before 
    programming the Strata DK. Up to 32 handsets per RWIU are allowed.
    2. Use the following programs:
    ©Program 03 for Code 61 (slot assignments).
    ©Program 32 for Auto Preference.
    ©Program 39 for flexible button assignments.
    ©Programs 81~89 for line ringing on the handsets.
    ©Program 91-9 for automatic PCB recognition.
    ©Programs *71~73 for DID ringing on specific handsets.
    Refer to Strata DK Programming Manual for specific information and Table 16-18 for 
    available Strata DK station features.
    Table 16-16 Example of Strata DK424 Base Cabinet Configuration with RCTUA4A
    PCBQuantity+5VDC PF-24VDC PF
    RCTUA4A 1 2.0 1.0
    RRCS-4 1 0.4 0.3
    PDKU2 2 1.6 0.3
    RCOU + RCOS 1 3.6 4.0 (8 COs)
    RBSU + RBSS 1 3.2 0.3
    RWIU 1 9.0 0.0
    Total 7 19.8 5.9
    Table 16-17 Example of Strata DK40i Expansion Cabinet Configuration
    PCBQuantity+5VDC PF-24VDC PF
    RCOU + RSOU 1 3.6 4.0 (8 COs)
    RBSU + RBSS 1 3.2 0.3
    RWIU 2 18.0 0.0
    Total 4 24.8 4.3
    Table 16-18 Available Station Features
    Feature Name
    Account Code Continuous DTMF Tones
    Automatic Call Distribution (ACD) DISA Security Code Revision
    Automatic Busy Redial (ABR) Do Not Disturb (DND)
    Automatic Call Back (ACB) DND Override (receive)
    Automatic Hold Exclusive Hold
    Automatic Line Selection Door Phone 
    						
    							Strata AirLink Systems
    RWIU System Installation
    16-44Strata DK I&M 5/99
    Step 10: Connect the PC
    äRun the RS-232-C cable to the back 
    of the PC (COM port 1) and insert 
    the 6-pin connector into the RWIU 
    jack (see Figure 16-28).
    Busy Override/Busy Station Transfer/Busy 
    Station RingingHeadset Interface
    Call Forward: Headset Receiver Volume Control
    lAll Calls Hearing Aid Compatible
    lBusy Liquid Crystal Display (LCD)
    lNo Answer Message Waiting Indication
    lBusy/No Answer Multiple Message Waiting
    lFixed Microphone Control (fixed) - Mute Only
    lExternal Microphone Sensitivity Control
    Call Park Orbits: Loud Ringing Bell (headset)
    lPark/Page Night Lock
    Call Pickup: Night Transfer
    lNight Bell Off-hook Call Announce (OCA) - Handset Mode
    lTenant Ringing Lines (four groups) Page Access
    lStation Groups (20 groups, all call types) Phantom Message Waiting Indication
    lAny Ringing LIne Pooled Line
    lDirected Station (all call types) Private CO Lines
    lHeld CO Lines (selectively) Push-button Dialing
    lParked Call Release and Release/Answer
    lExternal Page Remote Retrieval of Held/Parked Calls
    Centrex/PBX Compatible Ringing Line Preference
    CO/Centrex Saved Number Redial
    Conferencing Timed Reminders
    Dial Pulse DTMF Mode Change Toll Restriction Override Code Revision
    Direct Station Selection (DSS) User Programmable Feature Buttons
    DSS Console Features Table 16-18 Available Station Features
     (continued)
    Feature Name
    3333
    RS-232-C 6-pin Jack
    RWIU (side view)
    Figure 16-28 RWIU 6-pin Jack 
    						
    							Strata AirLink Systems
    RWIU System Installation
    Strata DK I&M 5/9916-45
    Strata AirLink Systems
    Step 11: Initialize the RWIU
    1. Open the RWIU Manager software.
    2. Turn on the Strata DK. The RWIU checks Base Station status and connections.
    3. Check the LEDs on the Base Stations. If all the LEDs are OFF, the initialization is complete.
    4. Check the handsets for dial tone. If there is dial tone, the initialization is complete.
    Step 12: Install the RWIU Manager
    1. Check the PC hardware/
    software against the required 
    minimums.Refer to “Check the System Hardware and Software 
    Requirements” on Page 16-3.
    2. Close any open applications 
    in Windows.
    3. Insert the RWIU Manager 
    floppy disk into the A:\ drive.
    4. In Windows 98/95, click Start 
    and Run
    ...or in Windows 3.11/3.1, 
    open Program Manager and 
    click File and Run.A dialog box displays requesting the location of the setup 
    disk.
    5. Type A:\Setup and click 
    OK.The Windows setup screen warns Windows applications 
    should be closed.
    6. Click Yes A dialog box displays recommending a destination path of 
    C:\Wireless.
    ...or No if applications need 
    to be closed.
    7. Click OK  C:\Wireless is accepted as the destination directory.
    ...or change the destination 
    drive/directory.
    8.  Click OK. A dialog box displays requesting verification of the 
    software location (its program directory or the Windows 
    system directory). Using the program directory is 
    recommended.
    9. Select the program directory.
    10. Click OK. The files are copied to the hard disk. A program group is 
    created. 
    						
    							Strata AirLink Systems
    RWIU System Installation
    16-46Strata DK I&M 5/99
    Step 13: Start the RWIU Manager
    Step 14: Set General Settings
    1. Make sure that the PC is 
    connected to the RWIU.
    2. From the RWIU program 
    group, double-click on the 
    Manager icon.
    After a few seconds, the Desktop Toolbar displays.
    1. From the Desktop Toolbar, 
    click the Config icon.
    2. Click General Settings and 
    assign COM port 1.
    3. Click OK.
    4. Click System ID.
    5. Enter the System ID.
    6. Click OK. General Settings window displays.
    3347
    3348
    3349
    3351 
    						
    							Strata AirLink Systems
    RWIU System Installation
    Strata DK I&M 5/9916-47
    Strata AirLink Systems
    Step 15: Enter the Handset IDs
    Step 16: Enable UTAM
    7. Click Time and Date.
    8. Enter the Date and time.
    9. Click OK.
    1. From the Desktop Toolbar, 
    click the Config icon.
    2. Click User Database.
    3. Download the settings from 
    the RWIU.Default IDs display.
    Handset IDs do not have 
    to be in numerical order 
    and can be changed at any 
    time.
    4. Click OK. The Desktop Toolbar displays.
    5. Upload the settings to the 
    RW IU .The new IDs are saved.
    1. From the Desktop Toolbar, 
    click the UTAM Activation 
    icon.
    3354
    3746
    3356 
    						
    							Strata AirLink Systems
    RWIU System Installation
    16-48Strata DK I&M 5/99
    Step 17: Store the IDs in the Handset
    2. Click Get UTAM Code from 
    RW IU .
    3. Enter the password 
    LABUTAM.
    4. Click OK twice. The Desktop Toolbar displays.
    5. Click Get UTAM code from 
    RW IU .The new 20-digit UTAM activation code displays. Call the 
    UTAM Activation desk at (949) 598-4980 between the 
    hours of 8:00 a.m. and 5:00 p.m. (Pacific Standard Time), 
    Monday through Friday with this number.
    6. Click OK. The Desktop Toolbar displays.
    7. Click Send UTAM 
    Activation Code to RWIU.
    8. Input the 10-digit code given 
    to you by the Activation Desk
    9. Press Enter.“Permission granted successfully” displays. If an error 
    message displays, repeat Steps 1~7.
    NoteIf UTAM is required, the Base Stations have one 
    power LED ON (green), two (center) transmission 
    LEDs ON (red), and four additional LEDs that are 
    red.
    1. Press 
    3:5. The handset turns on.
    2. Press 
    )&1.
    3357
    3358
    MENU
    OPERAT ION
    12 : 15 
    						
    All Toshiba manuals Comments (0)