    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							Fault Finding
    Station Cable Continuity Check
    Strata DK I&M 5/9912-9
    Fault Finding
    Cable Installation Test
    If cable voltmeter and ohmmeter tests are within limits, digital telephones, DDCBs, or DDSS 
    consoles may not operate.
    ä
    To perform the cable installation test
    1. Cable runs for the above digital devices must be free of cable splits (single or double). Test for 
    and eliminate all cable splits.
    2.Cable bridge taps – Digital telephones will not operate if cable runs contain any type (short or 
    long) of cable bridge. Test for and eliminate all cable bridges. 
    3. When installing the station cable, do not run parallel to and within 3 ft. of an AC power line. 
    AC power lines should cross at right (90°) angles only. In particular, avoid running station 
    wire pairs near devices that generate electrical noise, such as neon or fluorescent light fixtures.
    4.For DK40i: Chapter 3 – DK40i Installation, Table 3-10 on Page 3-39. Verify that your 
    telephone is wired correctly (2-pair or External power) for the options it supports (ADM, 
    RPCI-DI, PDIU-DI, HHEU, DVSU, etc.).
    Table 12-3 Station Cable Continuity Check for Digital Telephone Cables using Ohmmeter
    FromToVoltagePairWireColorPairWireColor
    1TGreen12 T Black open
    1 R Red 2 T Black open
    1 T Green 2 R Yellow open
    1 R Red 2 R Yellow open
    1 T Green 1 R Red 40 ohms
    2
    2 T Black 2 R Yellow 40 ohms2
    Table 12-4 Station Cable Continuity Check for Electronic Telephone Cables using Ohmmeter
    FromToVoltagePairWireColorPairWireColor
    1TGreen1
    1. The green-red, black-yellow and white-blue measurements should be within 10% 
    of each other.
    2 T Black open
    1 R Red 2 T Black open
    1 T Green 2 R Yellow open
    1 R Red 2 R Yellow open
    1 T Green 1 R Red 40 ohms
    2
    2. This is the maximum allowable reading for all digital and electronic telephone 
    cable runs except if connecting an HDSS console to circuits 7 and 8 of a PEKU, 
    then the maximum cable restriction is 20 ohms, not 40 ohms.
    2 T Black 2 R Yellow 40 ohms2
    3 T White 3 R Blue 40 ohms2
    3 T White 1 R Red open
    3 R Blue 1 R Red open
    3 T White 1 T Green open
    3 R Blue 1 T Green open
    3 T White 2 T Black open
    3 R Blue 2 T Black open
    3 T White 2 R Yellow open 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    12-10Strata DK I&M 5/99
    Fault Isolation Flowcharts
    The following troubleshooting flowcharts are available to aid in fault isolation. Toshiba 
    recommends reading the previous text in this chapter before proceeding to Flowchart 12-1 on Page 
    10 to begin fault isolation.
    START
    Please read 
    Chapters 2 and 3 
    before 
    proceeding.
    Is the
    system completely
    non-operational?
    Is it a station
    no dial tone
    fault?
    Is it a CO
    line no dial
    tone fault?
    Is a DSS
    console non-
    operational?
    Is it a
    voice mail/auto
    attd fault?
    Is it
    an SMDR
    fault?
    1-1
    Call your 
    technical support
    group.
    No No
    No
    No
    No
    Is it a
    remote 
    maintenance
    fault?
    Is the fault
    classified on
    this page?
    No
    No
    1-1
    No
    Yes
    Yes
    Yes
    Yes
    Yes
    YesYes
    Yes
    1879
    Go to
    Flowchart
    12-2
    Go to
    Flowchart
    12-8
    Go to
    appropriate
    Flowchart
    12-1~12-12
    Go to
    Flowchart
    12-3
    Go to
    Flowchart
    12-4
    Go to
    Flowchart
    12-5
    Go to
    Flowchart
    12-6
    Go to
    Flowchart
    12-7
    Flowchart 12-1 Fault Classification 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    Strata DK I&M 5/9912-11
    Fault Finding
    Flowchart 12-2 Catastrophic Faults
    START
    Is the system
    completely
    non-operational?
    Was the fault
    isolated by completing
    the system hardware
    check?
    Was the
    fault cleared
    after re-initializing
    the system?
    Call your
    technical support
    group. Does the fault
    re-occur after
    entering customer
    database? Reprogram customer
    database, one program
    at a time, and check
    to see if fault re-occurs.Tag the defective
    unit(s) and return
    for repair.
    2-1
    2-2
    2-5
    2-6
    2-82-3
    Go to
    Flowchart
    12-1
    2-4
    2-7
    END
    END
    No
    Yes
    Yes
    No
    No Yes
    Yes
    NoTest the Power Supply as described 
    in the installation sections of DK14 
    and DK40i and in this chapter for 
    DK424.  Also perform Hardware 
    Fault Isolation per this chapter.
    1880
    Re-initialize the system 
    (Programs 91-9 and 03) 
    and re-check fault using 
    default program data (do 
    not enter customer 
    database). 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    12-12Strata DK I&M 5/99
    Flowchart 12-3 Station Dial Tone Faults
    START
    Repair if necessary.
    Is the fault
    cleared?3-1 END Yes
    Is the 
    faulty station on a 
    replaceable station 
    PCB?
    3-2
    Replace the PCB
    and retest
    3-3 
    Replace the DK14 or DK40i 
    Base KSU. Or, test the DK424 
    common control PCB per the 
    Fault Isolation section. Initialize 
    the DK424/DK40i system
    (Prog: 91-9 and 03).
    Are the  
    faulty station(s) 
    only in the DK40i 
    Expansion KSU or only 
    one DK424 
    cabinet?
    Is the
    fault
    cleared?3-7
    No
    Retest.
    3-5Yes
    Is the
    fault
    cleared?Yes
    3-6
    END
    Go to
    3-4
    Go to
    3-4
    Call your technical
    support group. No
    YesNo
    NoNo
    3-8 Yes
    Is the fault
    cleared?NoYes3-4
    Replace the defective 
    unit and return it to the 
    repair center
    DK14: QCDU, 
    QSTU2
    DK40i Base KSU: 
    KSTU2 and all PCBs 
    in the DK40i 
    Expansion Unit
    DK424: PEKU, 
    PESU, PSTU, RSTU, 
    RDSU/RSTS, PDKUReplaceable Station 
    PCBs:Check station wiring
    per the Station Cable 
    Continuity Check in this 
    chapter.
    1881
    Change the DK40i 
    Expansion KSU and  
    retest or check the  
    cabinet power supply 
    per the RPSU280 
    power  supply test. 
    Then replace the 
    DK424 cabinet 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    Strata DK I&M 5/9912-13
    Fault Finding
    Flowchart 12-4 CO Line Dial Tone Faults
    Is the
    fault
    cleared?
    Go to
    4-5
    Call your technical
    support group.NoNo
    Yes
    Yes
    Retest.
    Change the DK14 or DK40i Base KSU or test 
    the DK424 common control PCB per the Fault 
    Isolation section and initialize the system 
    (Prog. 91-9 and 03).Is the
    fault
    cleared?Go to
    4-5
    4-7
    No
    No Are the 
    faulty CO lines 
    only in the DK40i 
    Expansion KSU or one 
    DK424 Cabinet?
    4-10
    4-5 Is the
    fault
    cleared?
    4-4
    Yes
    START
    Is the fault
    cleared?
    4-1
    4-2END
    No
    Are all 
    faulty CO lines 
    on a replaceable PCB 
    (not including KSU 
    motherboard)?
    Yes
    Change the PCB
     and retest.4-3
    Yes 1.
    2.
    No
    Replace the defective 
    unit and return it to the 
    repair center.
    END
    4-9 Yes
    Change the expansion 
    unit and retest.
    4-6DK14
    DK40i Base 
    KSU:
    DK40i only:
    DK40i 
    Expansion 
    KSU/ DK424:
    DK424 onlyReplaceable CO Line 
    PCBs:
    1882
    Check CO line wiring per Chapter 8.
    Test central office line using a 
    standard telephone or butt set at the 
    TELCO block.
              Repair as necessary.
    QCDU
    KCOU
    TCOU
    TDDU
    KCDU
    RCOU
    RCIU2
    REMU
    RDDU 
    PCOU
    REMU 
    RCOS 
    RGLU 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    12-14Strata DK I&M 5/99
    Flowchart 12-5 DSS Console Faults
    START
    DSS
    console
    type?
    5-0
    END DDSS
    Go to
    5-0
    Is the correct
    PCB slot code entered
    in Program 03?Enter correct PCB slot
    code using Program 03;
    then turn power OFF
    (for 5 seconds) and
    then ON.
    5-3
    Refer to Chapter 8 and verify wiring:
    Is the
    fault
    cleared?Yes
    5-4
    Go to
    5-3
    HDSS
    No
    On PEKU connected
    to HDSS, set SW1
    to the DSS position.
    5-1 No
    5-2
    Is the
    fault
    cleared?•
    •For DDSS, circuit 8 of the base
    unit or PDKU (KCDU does not 
    support DDSS).
    For HDSS, circuit 7 and 8 of 
    PEKU (PESU does not support
    HDSS).
    Correct as necessary.
    Correct as necessary.
    Is the
    fault
    cleared?Yes
    5-5
    Call your technical
    support group.No
    END
    END
    No
    Yes
    Yes
    1883
    Test DSS cable with cable continuity 
    checks in this chapter.
    NoteDSS is not available on DK14. 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    Strata DK I&M 5/9912-15
    Fault Finding
    Flowchart 12-6 Voice Mail/(External) Auto Attendant Faults 
    Is the
    fault
    cleared?Yes
    END
    START
    This chart assumes
    the VM/AA device
    has no faults.
    Is the
    fault
    cleared?Yes
    6-3
    No
    6-2
    Is VM/AA 
    integration completely
    non-operational?
    END Yes
    Read “Voice Mail Options” in Chapter 10 and 
    the programming instructions for: 
    DK14/DK40i: 03 (Code 92, slot 00 for 
    K4RCU3) DK424: 03 (Code 92~94 for  RCTU 
    PCB) DK14/DK40i/DK424: 15-0 and 15-3 
    (Auto release), and 31 (LEDs: 04, 05, 09, 
    15~20). This explains system hardware and 
    programming options related to VM and 
    external auto attendant.
    Correct Hardware/System Programming as 
    necessary.
    Check that the VM I.D. codes (656 and 
    657) are stored correctly in users’ digital or 
    electronic telephones. Use operating 
    procedures in the manual for instructions.
    6-1
    Check that the QRCU3 (DK14), 
    K5RCU (DK40i) or RRCS (DK424) is 
    installed correctly and programmed 
    with Code 92 in Prog. 03 (DK40i) or 
    Code 92, 93, and 94 in Prog. 03 
    (DK424).  
    No
    Check that VM/AA ports are connected to 
    standard telephone station ports correctly. 
    (Refer to QSTU2 (DK14), KSTU2 (DK40i 
    only). DK40i/DK424 RSTU2, PSTU, PESU, 
    and for the DK424 only, RDSU/RSTS wiring 
    diagrams in Chapter 8.)
    Correct if necessary.
    Is the
    fault
    cleared?Yes
    6-4
    No
    END
    Is the
    fault
    cleared?Yes
    6-5
    No
    END
    Call your technical 
    support group.
    Using a standard DTMF 
    telephone, check all standard 
    telephone circuits (QSTU2, 
    KSTU2,RSTU2, PSTU2, PESU).
    Replace defective PCB if 
    necessary.
    Other VM/AA related programs:
    • 10-2, LED 11 – No DTMF tones
    • 13 – Message center
    • 33 – Station hunting
    • 35 – Busy station transfer/ringing
    • 36 – Fixed call forward
    • 37 – Ring transfer recall time
    6-6 No
    1884 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    12-16Strata DK I&M 5/99
    Flowchart 12-7 Station Message Detail Recording (SMDR) Faults
    START
    No 
    SMDR data or 
    garbled data is 
    detected at the QSMU, 
    WSIU/TSIU/PIOU/PIOUS/
    RSIU/RSIS SMDR port.
    7-1
    Is the
    fault
    cleared?Yes
    7-5
    No
    This chart assumes
    the SMDR device
    has no faults.
    No
    END Yes
    Read the SMDR 
    installation 
    instructions in this 
    chapter before 
    proceeding with this 
    chart.
    SMDR
    data records are
    sent correctly but not
    when the customer
    requires.
    7-2Yes
    Set SMDR options in
    Program 60: Threshold
    time, long distance 
    calls only, etc.
    Is the
    fault
    cleared?
    Yes
    7-3
    END
    7-4
    Is the
    fault
    cleared?Yes
    7-6
    No
    END
    7-7
    Check that the SMDR device
    is wired correctly to the 
    WSIU/RSIU/RSIS/TSIU/PIOU/
    PIOUS SMDR port. (Refer to 
    PIOU or PIOUS wiring 
    instructions in Chapter 8.)
    Fix as required.
    Is the
    fault
    cleared?Yes
    7-8
    No
    END
    Is the
    fault
    cleared?Yes
    7-9
    No
    END
    Call your technical 
    support group. No
    No other faults are 
    classified. Call your 
    technical support 
    group for assistance.
    No
    DK40i/DK424: The SMDR port is 
    the bottom modular jack (TTY is 
    on top) of WSIU (DK14) or TSIU 
    (DK40i only) /PIOU/PIOUS.
    DK424: SMDR can be any jack on 
    RSIU or RSIS. See Program 76.
    The modular cord connecting to 
    the SMDR port must be 6-wires.Verify that the SMDR device 
    communication parameters are set 
    for: 8-data bits, no-parity, 1-stop bit, 
    300 or 1200 bps. RSIU/RSIS 1200, 
    2400, 4800 and 9600
    Change as required.
    Change the 
    PIOU/RSIU/RSIS/TSIU 
    PIOUS PCB. •
    •
    •
    Call your technical 
    support group.
    Verify that the PIOU/PIOUS, WSIU (DK14), or 
    TSIU (DK40i only) baud rate SW1 switch is in 
    the correct position (300 bps or 1200 bps) to 
    match the SMDR device baud rate. (Refer to 
    TSIU/PIOU/PIOUS installation in Chapter 7.)
    If using RSIU/RSIS with DK424, verify 
    Program 76-1 for port assignment. Verify baud 
    rate in Program 76-2 
    Change as required.
    1885 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    Strata DK I&M 5/9912-17
    Flowchart 12-8 Remote Maintenance Faults
    START
    Is Remote
    Maintenance connection
    via external modem on TTY
    port or IMDU
    modem?IMDU modem installed on
    PIOU or PIOUS
    8-1
    END This chart assumes that the remote 
    terminal and modem have no fault and that 
    Remote Maintenance does not operate.
    Is the
    fault
    cleared?
    Call your technical 
    support group.
    If a digital or electronic telephone 
    is in the Programming mode, it is 
    not possible to enter the Remote 
    Maintenance mode.
    8-5
    8-4
    Is the
    fault
    cleared?
    8-3
    Check that the WSIU/TSIU/PIOU/PIOUS SW3 
    switch is in the TTY position. For DK424, 
    check Program 76-1 and verify the port is 
    programmed as a 1 for TTY.
    Correct as necessary.
    8-2
    YES
    NO
    Check that the modem or terminal connected 
    to the TTY port is wired correctly per the  
    WSIU/TSIU/PIOU/PIOUS, RSIU/RSIS, RSSU 
    MDF wiring in Chapter 8.
    Correct above if necessary or replace WSIU, 
    TSIU, PIOU, PIOUS, or RSIU/RSIS.The TTY port is the top modular 
    jack (SMDR is bottom) of the 
    PIOU/PIOUS.
    The modular cord connecting the 
    TTY port to the terminal or external 
    modem must be 6-wires.
    TTY can be any jack on 
    RSIU/RSIS—see Program 76. •
    •
    • Check that the baud rate switch (SW2, push-button switch on PIOU/PIOUS) is set to match the remote 
    terminal baud rate (300 bps LED ON, 1200 bps LED OFF) . 
    DK40i: check that the WSIU, TSIU, IMDU, PIOU, or PIOUS is installed correctly.
    DK424: check that the RSIU, RMDS, IMDU, RSSU, PIOU or PIOUS is installed correctly.
    If using RSIU/RSIS/RMDS, check that Program 76 settings match DKAdmin/DKBackup PC and modem 
    or remote terminal/modem.
    Check that communication parameters of remote terminal are set to match the PIOU or PIOUS TTY 
    port or IMDY (7-data bits, even parity, 1-stop bit).
    External modem connected 
    to the WSIU, TSIU, PIOU, 
    PIOUS TTY port
    Check that the communication parameters of 
    the remote terminal are set to match the
    IMDU (7-data bits, even parity, 1-stop bit).
    Check that the PIOU/PIOUS SW3
    switch is in the MODEM position.
    Enable the IMDU by turning LED 14 ON in 
    Program 77-1.
        If required, assign CO lines for DISA or to      
    ring IMDU in  system Program 78, Code 
    51~53.
    When calling IMDU or RMDS via DISA or 
    ring transfer, dial #19.
    If calling RMDS or IMDU via DID lines, call 
    the sttion number assigned to Port 085 
    (RCTUB) or Port 245 (RCTUC/D) in 
    Program *09 or 71, 72 and 73.
     
    Correct above if necessary or
    replace IMDU or PIOU(S). •
    •
    •
     
    1886 
    						
    							Fault Finding
    Fault Isolation Flowcharts
    12-18Strata DK I&M 5/99 
    						