Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DK40i/DK424 Universal Slot PCB Wiring Digital Station Wiring Strata DK I&M 5/998-17 DK40i/DK424 Universal Slot PCB Wiring Attendant Console Wiring Diagrams Figure 8-16 PC Attendant Console MDF Wiring Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50W-BL BL-W W-O O-W W-GN GN-W W-BR BR-W W-S S-W R-BL BL-R R-O O-R R-GN GN-R R-BR BR-R R-S S-R BK-BL BL-BK BK-O O-BK BK-GN GN-BK BK-BR BR-BK BK-S S-BK Y-BL BL-Y Y-O O-Y Y-GN GN-Y Y-BR BR-Y Y-S S-Y V-BL BL-V V-O O-V V-GN GN-V V-BR BR-V V-S S-V26 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25Bridging Clips To RATU PCB W/Female Connector 25-pair Cable W/Male Amp Connector 66M150 Split Block PC Attendant Console Cabling3 PC Attendant Console #2 T2 R2 PT2 PR2 T3 R3 PT3 PR3 T4 R4 PT4 PR4 (-) T1 (Voice/Data) (GND) R1 (Voice/Data) (-) (GND)GN 654321Y BLR BK W 34 R1 PT1T1 PR1 25 PR TR PT RJ11 GND PR(-) TGND R(-) PT Jacketed Twisted Pairs 24 AWG (2 Pair, See Note 1) Customer-supplied PC Attendant Console AUX IN REC OUT RJ45 RJ11 DB9 (Female) RATI (Rear Connections) 8-pair modular cord (RJ45 plugs on each end) To AC Outlet2 PC Attendant Console #3 PC Attendant Console #4 Notes 1. RATI is wired with 1-pair wiring - maximum distance from KSU (RATU PCB) is 1,000 feet (303 m). 2. PC Attendant Console and CRT require local AC power. 3. Attendant console cable runs must not have the following: • Cable splits (single or double) • Cable bridges (of any length) • High resistance or faulty cable splices 4. To tape recorder “REC” input. 5. Audio input is for future use. 2-pair modular cord (RJ11 plugs on each end) Customer-supplied 9-pin computer cable 9 ft. max. (female DB9 connectors on each end)to PC COM Port 1-pair Modular Cord Handset RATHC Headset 150~200 W 2-pair Modular (–22 dBv Output) 4 (–25 ~ –30 dBv Audio Input – Future Use) Audio Plugs 1607
DK40i/DK424 Universal Slot PCB Wiring Digital Station Wiring 8-18Strata DK I&M 5/99 Figure 8-17 Attendant Console MDF Wiring Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50W-BL BL-W W-O O-W W-GN GN-W W-BR BR-W W-S S-W R-BL BL-R R-O O-R R-GN GN-R R-BR BR-R R-S S-R BK-BL BL-BK BK-O O-BK BK-GN GN-BK BK-BR BR-BK BK-S S-BK Y-BL BL-Y Y-O O-Y Y-GN GN-Y Y-BR BR-Y Y-S S-Y V-BL BL-V V-O O-V V-GN GN-V V-BR BR-V V-S S-V26 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25Bridging Clips To RATU PCB W/Female Connector 25-pair Cable W/Male Amp Connector 66M150 Split Block Console Cabling3 Attendant Console #2 T2 R2 PT2 PR2 T3 R3 PT3 PR3 T4 R4 PT4 PR4 (-) T1 (Voice/Data) (GND) R1 (Voice/Data) (-) T1 (GND) R1GN 654321Y BLR BK W 34 R1 PT1T1 PR1 25 PR TR PT RJ11 2-pair Modular Cord GND PR(-) TGND R(-) PT Jacketed Twisted Pairs 24 AWG (2-pair, See Note 1) 9-wire Cable W/DB-9 Male Plug Modular Plug RJ11 Modular Jack DB-9 Female Jack EGA Color Monitor Or EL Display 3-Prong AC Plug To 120VAC2 Attendant Console #3 Attendant Console #4 ATTENDANT CONSOLE #1 Notes 1. Console must be wired with 2-pair wiring - maximum distance from DK424 KSU (RATU PCB) is 1,000 feet (303 m). 2. EGA monitor or EL display require local AC power. 3. Attendant console cable runs must not have the following: • Cable splits (single or double) • Cable bridges (of any length) • High resistance or faulty cable splices RS-232C Connector (Not Used) 1606 Not Used
DK40i/DK424 Universal Slot PCB Wiring Digital Station Wiring Strata DK I&M 5/998-19 DK40i/DK424 Universal Slot PCB Wiring Analog Devices Wiring Figure 8-18 MDF Wiring/Standard Telephone, Voice Mail, DPFT to RSTU/RSTU2/RDSU/RSTS/PSTU/PSTU2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50W-BL BL-W W-O O-W W-GN GN-W W-BR BR-W W-S S-W R-BL BL-R R-O O-R R-GN GN-R R-BR BR-R R-S S-R BK-BL BL-BK BK-O O-BK BK-GN GN-BK BK-BR BR-BK BK-S S-BK Y-BL BL-Y Y-O O-Y Y-GN GN-Y Y-BR BR-Y Y-S S-Y V-BL BL-V V-O O-V V-GN GN-V V-BR BR-V V-S S-V26 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 Bridging Clips To RSTU2 or PSTU or PSTU2 w/Female Connector 25-Pair Cable w/Male amp Connector 66M150 Split Block GN 654321Y BLR BK W 123456 Jacketed Twisted Station Cable 24 AWG Modular Cord Tip 1 Ring 1 T2 R2 T3 R3 T4 R4 T5 R5 T6 R6 T7 R7 T8 R8Not Used Not Used Not Used Not Used Not Used Not Used Not Used DG -24VNot UsedTip Ring DPFT Power Failure Transfer Box (J1) DG (J1, 50)-24 Volts (J1, 25) Notes • An alternate BGM source can be connected to Circuit 2 of RSTU or PSTU. An isolation transformer may be required when connecting BGM to RSTU or PSTU (see Chapter 10 – Peripheral Installation, Alternate BGM Source to RSTU). • See Strata DK General Description, Station Loop Requirements table for loop requirements. • Two ringers maximum. (Note 1) 1583 Standard Telephone, Voice Mail Port, ACD/Auto Attendant Digital Announcer, or Similar Device
DK40i/DK424 Universal Slot PCB Wiring Digital Station Wiring 8-20Strata DK I&M 5/99 NoteIndicate if standard telephone, voice mail port, etc. Figure 8-19 RSTU/RSTU2/RDSU/RSTS/PSTU/PSTU2 Station MDF Cross Connect RecordMDF Block Number KSU Slot Number Color CodeDesignationCKT NumberPort NumberIntercom NumberDevice/Standard Telephone/Electronic Telephone Location W-Bl T 1 Bl-W R W-O Not Used O-W Not Used W-G T 2 Indicate if separate BGM source. G-W R W-Br Not Used Br-W Not Used W-S T 3 S-W R R-Bl Not Used Bl-R Not Used R-O T 4 O-R R R-G Not Used G-R Not Used R-Br T 5 Br-R R R-S Not Used S-R Not Used Bk-Bl T 6 Bl-Bk R Bk-O Not Used O-Bk Not Used Bk-G T 7 G-Bk R Bk-Br Not Used Br-Bk Not Used Bk-S T 8 S-Bk R Y-Bl Not Used Bl-Y Not Used
DK40i/DK424 Universal Slot PCB Wiring Power Failure Cut Through (DPFT) Wiring Pin-outs Strata DK I&M 5/998-21 DK40i/DK424 Universal Slot PCB Wiring Power Failure Cut Through (DPFT) Wiring Pin-outs Figure 8-20 DPFT Connector J2/Terminal Sequence & Designations/Station Line Connection PairPinColor CodeLead DesignationFunctionPSTU/RSTU PCB Position 1t 26 W-BI T TIP-TEL #1 R1BI-WRRING-TEL#12T 27 W-O T TIP-RSTU/RSTU/RDSU #1R2O-WRRING-PSTU/RSTU/RDSU#1 3T 28 W-G T TIP-TEL #2R3G-WRRING-TEL#24T 29 W-Br T TIP-RSTU/RSTU/RDSU #2 R4Br-WRRING-PSTU/RSTU/RDSU#25T 30 W-S T TIP-TEL #3R5S-WRRING-TEL#3 6T 31 R-BI T TIP-RSTU/RSTU/RDSU #3R6BI-RRRING-PSTU/RSTU/RDSU#37T 32 R-O T TIP-TEL #4 R7O-RRRING-TEL#48T 33 R-G T TIP-RSTU/RSTU/RDSU #4 R8G-RRRING-PSTU/RSTU/RDSU#49T 34 R-Br T TIP-TEL #5R9Br-RRRING-TEL#5 10T 35 R-S T TIP-RSTU/RSTU/RDSU #5R10S-RRRING-PSTU/RSTU/RDSU#511T 36 Bk-BI T TIP-TEL #6 R11BI-BkRRING-TEL#612T 37 Bk-O T TIP-RSTU/RSTU/RDSU #6R12O-BkRRING-PSTU/RSTU/RDSU#6 13T 38 Bk-G T TIP-TEL #7R13G-BkRRING-TEL#714T 39 Bk-Br T TIP-RSTU/RSTU/RDSU #7 R14Br-BkRRING-PSTU/RSTU/RDSU#715T 40 Bk-S T TIP-TEL #8R15S-BkRRING-TEL#8 16T 41 Y-Bl T TIP-RSTU/RSTU/RDSU #8R16Bl-YRRING-PSTU/RSTU/RDSU#817T 42 Y-O Spare R17O-YSpare 18T 43 Y-GSpare R18G-YSpare 19T 44 Y-BrSpare R19Br-YSpare 20T 45 Y-SSpare R20S-YSpare 21T 46 V-BlSpare R21Bl-VSpare 22T 47 V-OSpare R22O-VSpare 23T 48 V-GSpare R23G-VSpare 24T 49 V-BrSpare R24Br-VSpare 25T 50 V-SSpare R25S-VSpare
DK40i/DK424 Universal Slot PCB Wiring Power Failure Cut Through (DPFT) Wiring Pin-outs 8-22Strata DK I&M 5/99 Figure 8-21 DPFT Connector J1/Terminal Sequence & Designations/CO Line Connection & DPFT Control PairPinColor CodeLead DesignationFunctionPSTU/RSTU PCB Position 1t 26 W-BI T TIP-CO #1R1BI-WRRING-CO#1 2T 27 W-O T TIP-PCOU/RCOU #1R2O-WRRING-PCOU/RCOU#13T 28 W-G T TIP-CO #2 R3G-WRRING-CO#24T 29 W-Br T TIP-PCOU/RCOU #2R4Br-WRRING-PCOU/RCOU#2 5T 30 W-S T TIP-CO #3R5S-WRRING-CO#36T 31 R-BI T TIP-PCOU/RCOU #3 R6BI-RRRING-PCOU/RCOU#37T 32 R-O T TIP-CO #4R7O-RRRING-CO#4 8T 33 R-G T TIP-PCOU/RCOU #4R8G-RRRING-PCOU/RCOU#4 9T 34 R-Br T TIP-CO #5R9Br-RRRING-CO#510T 35 R-S T TIP-PCOU/RCOU #5 R10S-RRRING-PCOU/RCOU#511T 36 Bk-BI T TIP-CO #6R11BI-BkRRING-CO#6 12T 37 Bk-O T TIP-PCOU/RCOU #6R12O-BkRRING-PCOU/RCOU#613T 38 Bk-G T TIP-CO #7 R13G-BkRRING-CO#714T 39 Bk-Br T TIP-PCOU/RCOU #7R14Br-BkRRING-PCOU/RCOU#7 15T 40 Bk-S T TIP-CO #8R15S-BkRRING-CO#816T 41 Y-Bl T TIP-PCOU/RCOU #8 R16Bl-YRRING-PCOU/RCOU#817T 42 Y-O Spare R17O-YSpare 18T 43 Y-GSpare R18G-YSpare 19T 44 Y-BrSpare R19Br-YSpare 20T 45 Y-SSpare R20S-YSpare 21T 46 V-BlSpare R21Bl-VSpare 22T 47 V-OSpare R22O-VSpare 23T 48 V-GSpare R23G-VSpare 24T 49 V-BrSpare R24Br-VSpare 25T 50 V-S PFT DG PFT GROUND (INPUT) RDSU/RSTU/PSTU/PIN50R25S-VPFT -24VPFT -24V (INPUT)RDSU/RSTU/PSTU/PIN25
DK40i/DK424 Universal Slot PCB Wiring CO Line Wiring Diagrams Strata DK I&M 5/998-23 DK40i/DK424 Universal Slot PCB Wiring CO Line Wiring Diagrams Figure 8-22 MDF Wiring/CO Lines to PCOU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Bridging Clips 66M150 Split Block GN 654321Y BLR BK W 2345 Modular Cord 6-1 1 2 3 4 5 6 6-1 T1 R1 T2 R2T1 R1 T2 R2 To Network R1 R2T1 T2 Telco-provided Modular Block, 625-Type or Equivalent PCOU #4 #3 #2 #1 CO3+4 SameR4 R3 T3 T4 5 4 3 2 R2 R1 T1 T2 5 4 3 2 CO1+2 PCOU Pin-out Network Jack: RJ14C FIC: 02LS2 1 2 3 4 5 6 1586
DK40i/DK424 Universal Slot PCB Wiring CO Line Wiring Diagrams 8-24Strata DK I&M 5/99 Figure 8-23 CO Line (RCOU/RCOS, RGLU2, RDDU, PEMU, REMU, RDDU, RDTU) MDF Cross Connect Record MDF Block NumberCO Line NumberPCB Type and Cabinet Slot NumberMDF Block NumberCO Line NumberPCB Type and Cabinet Slot NumberMDF Block NumberCO Line NumberPCB Type and Cabinet Slot Number
DK40i/DK424 Universal Slot PCB Wiring CO Line Wiring Diagrams Strata DK I&M 5/998-25 DK40i/DK424 Universal Slot PCB Wiring Figure 8-24 MDF Wiring/CO Lines to RGLU2 or PCOU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Bridging Clips 66M150 Split Block GN 654321Y BLR BK W 2345 Modular Cord 6-1 1 2 3 4 5 6 6-1 T1 R1 T2 R2T1 R1 T2 R2 To Network R1 R2T1 T2 Telco-provided Modular Block, 625-Type Or Equivalent RGLU or PCOU #4 #3 #2 #1 CO3+4 SameR4 R3 T3 T4 5 4 3 2 R2 R1 T1 T2 5 4 3 2CO1+2 PCOU Pin-out Network Jack: RJ14C FIC: 02LS2 (PCOU), 02GS2 (RGLU2) 1 2 3 4 5 6 1598
DK40i/DK424 Universal Slot PCB Wiring CO Line Wiring Diagrams 8-26Strata DK I&M 5/99 Figure 8-25 MDF Wiring/CO to RCOU/RCOS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Bridging Clips 66M150 Split Block GN 654321Y BLR BK W 2345 Modular Cord 1 2 3 4 5 6 T1 R1 T2 R2T1 R1 T2 R2 To Network R1 R2T1 T2 Telco-provided Modular Block, 625-type or Equivalent SameR8 R7 T7 T8 5 4 3 2 R2 R1 T1 T2 5 4 3 2 Network Jack: RJ14C FIC: 02LS2 6-1 6-1 4 3 2 1 7 + 8 1-6 1-6 8 7 6 5 3 + 4 5 + 6 RCOU RCOS (DK424 only) 1 + 2 1 2 3 4 5 6SameR4 R3 T3 T4 5 4 3 2 1 2 3 4 5 6SameR6 R5 T5 T6 5 4 3 2 1 2 3 4 5 6 1602