    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							DK40i/DK424 Universal Slot PCB Wiring
    Digital Station Wiring
    Strata DK I&M    5/998-17
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Attendant Console Wiring Diagrams
    Figure 8-16 PC Attendant Console MDF Wiring Diagram
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50W-BL
    BL-W
    W-O
    O-W
    W-GN
    GN-W
    W-BR
    BR-W
    W-S
    S-W
    R-BL
    BL-R
    R-O
    O-R
    R-GN
    GN-R
    R-BR
    BR-R
    R-S
    S-R
    BK-BL
    BL-BK
    BK-O
    O-BK
    BK-GN
    GN-BK
    BK-BR
    BR-BK
    BK-S
    S-BK
    Y-BL
    BL-Y
    Y-O
    O-Y
    Y-GN
    GN-Y
    Y-BR
    BR-Y
    Y-S
    S-Y
    V-BL
    BL-V
    V-O
    O-V
    V-GN
    GN-V
    V-BR
    BR-V
    V-S
    S-V26
    1
    27
    2
    28
    3
    29
    4
    30
    5
    31
    6
    32
    7
    33
    8
    34
    9
    35
    10
    36
    11
    37
    12
    38
    13
    39
    14
    40
    15
    41
    16
    42
    17
    43
    18
    44
    19
    45
    20
    46
    21
    47
    22
    48
    23
    49
    24
    50
    25Bridging Clips To RATU PCB W/Female Connector
    25-pair Cable W/Male Amp Connector
    66M150  Split Block
    PC Attendant
    Console Cabling3
    PC Attendant
    Console #2 T2
    R2
    PT2
    PR2
    T3
    R3
    PT3
    PR3
    T4
    R4
    PT4
    PR4 (-)          T1 (Voice/Data)
    (GND)   R1 (Voice/Data)
    (-)
    (GND)GN
    654321Y
    BLR
    BK
    W
    34
    R1
    PT1T1
    PR1
    25
    PR    TR    PT
    RJ11
    GND
    PR(-)
    TGND
    R(-)
    PT
    Jacketed Twisted Pairs
    24 AWG (2 Pair, See Note 1)
    Customer-supplied
    PC Attendant Console
    AUX
    IN REC
    OUT
    RJ45
    RJ11
    DB9 (Female) RATI
    (Rear Connections) 8-pair modular cord
    (RJ45 plugs on each end)
    To AC
    Outlet2
    PC Attendant
    Console #3
    PC Attendant
    Console #4
    Notes
    1. RATI is wired with 1-pair wiring - maximum distance from KSU 
    (RATU PCB) is 1,000 feet (303 m).
    2. PC Attendant Console and CRT require local AC power.
    3. Attendant console cable runs must not have the following:
    • Cable splits (single or double)
    • Cable bridges (of any length)
    • High resistance or faulty cable splices
    4. To tape recorder “REC” input.
    5. Audio input is for future use.
    2-pair modular cord
    (RJ11 plugs on each end)
    Customer-supplied
    9-pin computer cable
    9 ft. max.  (female DB9
    connectors on each end)to PC
    COM Port 1-pair
    Modular Cord
    Handset
    RATHC
    Headset
    150~200 W
    2-pair Modular 
    (–22 dBv Output)
    4
    (–25 ~ –30 dBv
    Audio Input –
    Future Use) 
    Audio Plugs
    1607 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Digital Station Wiring
    8-18Strata DK I&M    5/99
    Figure 8-17 Attendant Console MDF Wiring Diagram
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50W-BL
    BL-W
    W-O
    O-W
    W-GN
    GN-W
    W-BR
    BR-W
    W-S
    S-W
    R-BL
    BL-R
    R-O
    O-R
    R-GN
    GN-R
    R-BR
    BR-R
    R-S
    S-R
    BK-BL
    BL-BK
    BK-O
    O-BK
    BK-GN
    GN-BK
    BK-BR
    BR-BK
    BK-S
    S-BK
    Y-BL
    BL-Y
    Y-O
    O-Y
    Y-GN
    GN-Y
    Y-BR
    BR-Y
    Y-S
    S-Y
    V-BL
    BL-V
    V-O
    O-V
    V-GN
    GN-V
    V-BR
    BR-V
    V-S
    S-V26
    1
    27
    2
    28
    3
    29
    4
    30
    5
    31
    6
    32
    7
    33
    8
    34
    9
    35
    10
    36
    11
    37
    12
    38
    13
    39
    14
    40
    15
    41
    16
    42
    17
    43
    18
    44
    19
    45
    20
    46
    21
    47
    22
    48
    23
    49
    24
    50
    25Bridging Clips To RATU PCB W/Female
    Connector
    25-pair Cable W/Male Amp Connector
    66M150  Split Block
    Console Cabling3
    Attendant
    Console #2 T2
    R2
    PT2
    PR2
    T3
    R3
    PT3
    PR3
    T4
    R4
    PT4
    PR4 (-)          T1 (Voice/Data)
    (GND)   R1 (Voice/Data)
    (-)          T1
    (GND)   R1GN
    654321Y
    BLR
    BK
    W
    34
    R1
    PT1T1
    PR1
    25
    PR    TR    PT
    RJ11
    2-pair
    Modular Cord
    GND
    PR(-)
    TGND
    R(-)
    PT
    Jacketed Twisted Pairs
    24 AWG (2-pair, See Note 1)
    9-wire Cable 
    W/DB-9 Male Plug
    Modular Plug
    RJ11 Modular Jack
    DB-9
    Female
    Jack
    EGA Color 
    Monitor 
    Or EL Display
    3-Prong 
    AC Plug
    To 120VAC2
    Attendant
    Console #3
    Attendant
    Console #4
    ATTENDANT CONSOLE #1
    Notes
    1. Console must be wired with 2-pair wiring - maximum distance from 
    DK424 KSU (RATU PCB) is 1,000 feet (303 m).
    2. EGA monitor or EL display require local AC power.
    3. Attendant console cable runs must not have the following:
    •  Cable splits (single or double)
    •  Cable bridges (of any length)
    •  High resistance or faulty cable splices
    RS-232C Connector
    (Not Used)
    1606
    Not Used 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Digital Station Wiring
    Strata DK I&M    5/998-19
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Analog Devices Wiring
    Figure 8-18 MDF Wiring/Standard Telephone, Voice Mail, DPFT to RSTU/RSTU2/RDSU/RSTS/PSTU/PSTU2
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50W-BL
    BL-W
    W-O
    O-W
    W-GN
    GN-W
    W-BR
    BR-W
    W-S
    S-W
    R-BL
    BL-R
    R-O
    O-R
    R-GN
    GN-R
    R-BR
    BR-R
    R-S
    S-R
    BK-BL
    BL-BK
    BK-O
    O-BK
    BK-GN
    GN-BK
    BK-BR
    BR-BK
    BK-S
    S-BK
    Y-BL
    BL-Y
    Y-O
    O-Y
    Y-GN
    GN-Y
    Y-BR
    BR-Y
    Y-S
    S-Y
    V-BL
    BL-V
    V-O
    O-V
    V-GN
    GN-V
    V-BR
    BR-V
    V-S
    S-V26
    1
    27
    2
    28
    3
    29
    4
    30
    5
    31
    6
    32
    7
    33
    8
    34
    9
    35
    10
    36
    11
    37
    12
    38
    13
    39
    14
    40
    15
    41
    16
    42
    17
    43
    18
    44
    19
    45
    20
    46
    21
    47
    22
    48
    23
    49
    24
    50
    25
    Bridging
    Clips To RSTU2 or PSTU or PSTU2 
    w/Female Connector
    25-Pair Cable w/Male amp Connector
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    123456
    Jacketed Twisted Station Cable
    24 AWG
    Modular
    Cord
    Tip 1
    Ring 1
    T2
    R2
    T3
    R3
    T4
    R4
    T5
    R5
    T6
    R6
    T7
    R7
    T8
    R8Not Used
    Not Used
    Not Used
    Not Used
    Not Used
    Not Used
    Not Used
    DG
    -24VNot UsedTip         Ring
    DPFT
    Power Failure
    Transfer Box
    (J1)
    DG
    (J1, 50)-24 Volts
    (J1, 25)
    Notes
    • An alternate BGM source can be connected to 
    Circuit 2 of RSTU or PSTU. An isolation 
    transformer may be required when connecting 
    BGM to RSTU or PSTU (see Chapter 10 – 
    Peripheral Installation, Alternate BGM Source to 
    RSTU).
    • See Strata DK General Description, Station Loop 
    Requirements table for loop requirements.
    • Two ringers maximum.
    (Note 1)
    1583
    Standard Telephone,
    Voice Mail Port, ACD/Auto
    Attendant Digital Announcer, 
    or Similar Device 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Digital Station Wiring
    8-20Strata DK I&M    5/99
    NoteIndicate if standard telephone, voice mail port, etc.
    Figure 8-19 RSTU/RSTU2/RDSU/RSTS/PSTU/PSTU2 Station MDF Cross Connect RecordMDF Block Number KSU Slot Number
    Color CodeDesignationCKT 
    NumberPort 
    NumberIntercom 
    NumberDevice/Standard Telephone/Electronic 
    Telephone Location
    W-Bl T
    1 Bl-W R
    W-O Not Used
    O-W Not Used
    W-G T
    2 Indicate if separate BGM source. G-W R
    W-Br Not Used
    Br-W Not Used
    W-S T
    3 S-W R
    R-Bl Not Used
    Bl-R Not Used
    R-O T
    4 O-R R
    R-G Not Used
    G-R Not Used
    R-Br T
    5 Br-R R
    R-S Not Used
    S-R Not Used
    Bk-Bl T
    6 Bl-Bk R
    Bk-O Not Used
    O-Bk Not Used
    Bk-G T
    7 G-Bk R
    Bk-Br Not Used
    Br-Bk Not Used
    Bk-S T
    8 S-Bk R
    Y-Bl Not Used
    Bl-Y Not Used 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Power Failure Cut Through (DPFT) Wiring Pin-outs
    Strata DK I&M    5/998-21
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Power Failure Cut Through (DPFT) Wiring Pin-outs
    Figure 8-20 DPFT Connector J2/Terminal Sequence & Designations/Station Line Connection
    PairPinColor CodeLead DesignationFunctionPSTU/RSTU PCB Position
    1t 26 W-BI T TIP-TEL #1
    R1BI-WRRING-TEL#12T 27 W-O T TIP-RSTU/RSTU/RDSU #1R2O-WRRING-PSTU/RSTU/RDSU#1
    3T 28 W-G T TIP-TEL #2R3G-WRRING-TEL#24T 29 W-Br T TIP-RSTU/RSTU/RDSU #2
    R4Br-WRRING-PSTU/RSTU/RDSU#25T 30 W-S T TIP-TEL #3R5S-WRRING-TEL#3
    6T 31 R-BI T TIP-RSTU/RSTU/RDSU #3R6BI-RRRING-PSTU/RSTU/RDSU#37T 32 R-O T TIP-TEL #4
    R7O-RRRING-TEL#48T 33 R-G T TIP-RSTU/RSTU/RDSU #4
    R8G-RRRING-PSTU/RSTU/RDSU#49T 34 R-Br T TIP-TEL #5R9Br-RRRING-TEL#5
    10T 35 R-S T TIP-RSTU/RSTU/RDSU #5R10S-RRRING-PSTU/RSTU/RDSU#511T 36 Bk-BI T TIP-TEL #6
    R11BI-BkRRING-TEL#612T 37 Bk-O T TIP-RSTU/RSTU/RDSU #6R12O-BkRRING-PSTU/RSTU/RDSU#6
    13T 38 Bk-G T TIP-TEL #7R13G-BkRRING-TEL#714T 39 Bk-Br T TIP-RSTU/RSTU/RDSU #7
    R14Br-BkRRING-PSTU/RSTU/RDSU#715T 40 Bk-S T TIP-TEL #8R15S-BkRRING-TEL#8
    16T 41 Y-Bl T TIP-RSTU/RSTU/RDSU #8R16Bl-YRRING-PSTU/RSTU/RDSU#817T 42 Y-O Spare
    R17O-YSpare
    18T 43 Y-GSpare
    R18G-YSpare
    19T 44 Y-BrSpare
    R19Br-YSpare
    20T 45 Y-SSpare
    R20S-YSpare
    21T 46 V-BlSpare
    R21Bl-VSpare
    22T 47 V-OSpare
    R22O-VSpare
    23T 48 V-GSpare
    R23G-VSpare
    24T 49 V-BrSpare
    R24Br-VSpare
    25T 50 V-SSpare
    R25S-VSpare 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Power Failure Cut Through (DPFT) Wiring Pin-outs
    8-22Strata DK I&M    5/99
    Figure 8-21 DPFT Connector J1/Terminal Sequence & Designations/CO Line Connection & DPFT Control
    PairPinColor CodeLead DesignationFunctionPSTU/RSTU PCB Position
    1t 26 W-BI T TIP-CO #1R1BI-WRRING-CO#1
    2T 27 W-O T TIP-PCOU/RCOU #1R2O-WRRING-PCOU/RCOU#13T 28 W-G T TIP-CO #2
    R3G-WRRING-CO#24T 29 W-Br T TIP-PCOU/RCOU #2R4Br-WRRING-PCOU/RCOU#2
    5T 30 W-S T TIP-CO #3R5S-WRRING-CO#36T 31 R-BI T TIP-PCOU/RCOU #3
    R6BI-RRRING-PCOU/RCOU#37T 32 R-O T TIP-CO #4R7O-RRRING-CO#4
    8T 33 R-G T TIP-PCOU/RCOU #4R8G-RRRING-PCOU/RCOU#4
    9T 34 R-Br T TIP-CO #5R9Br-RRRING-CO#510T 35 R-S T TIP-PCOU/RCOU #5
    R10S-RRRING-PCOU/RCOU#511T 36 Bk-BI T TIP-CO #6R11BI-BkRRING-CO#6
    12T 37 Bk-O T TIP-PCOU/RCOU #6R12O-BkRRING-PCOU/RCOU#613T 38 Bk-G T TIP-CO #7
    R13G-BkRRING-CO#714T 39 Bk-Br T TIP-PCOU/RCOU #7R14Br-BkRRING-PCOU/RCOU#7
    15T 40 Bk-S T TIP-CO #8R15S-BkRRING-CO#816T 41 Y-Bl T TIP-PCOU/RCOU #8
    R16Bl-YRRING-PCOU/RCOU#817T 42 Y-O Spare
    R17O-YSpare
    18T 43 Y-GSpare
    R18G-YSpare
    19T 44 Y-BrSpare
    R19Br-YSpare
    20T 45 Y-SSpare
    R20S-YSpare
    21T 46 V-BlSpare
    R21Bl-VSpare
    22T 47 V-OSpare
    R22O-VSpare
    23T 48 V-GSpare
    R23G-VSpare
    24T 49 V-BrSpare
    R24Br-VSpare
    25T 50 V-S PFT DG PFT GROUND (INPUT) RDSU/RSTU/PSTU/PIN50R25S-VPFT -24VPFT -24V (INPUT)RDSU/RSTU/PSTU/PIN25 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    Strata DK I&M    5/998-23
    DK40i/DK424 Universal 
    Slot PCB Wiring
    CO Line Wiring Diagrams
    Figure 8-22 MDF Wiring/CO Lines to PCOU
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    2345
    Modular
    Cord
    6-1
    1 2
    3 4 5 6
    6-1
    T1
    R1
    T2
    R2T1
    R1
    T2
    R2 To
    Network
    R1
    R2T1
    T2
    Telco-provided
    Modular Block,
    625-Type or
    Equivalent
    PCOU
    #4
    #3
    #2
    #1
    CO3+4
    SameR4
    R3
    T3
    T4 5
    4
    3
    2
    R2
    R1
    T1
    T2 5
    4
    3
    2
    CO1+2
    PCOU
    Pin-out
    Network Jack: RJ14C
    FIC: 02LS2
    1 2
    3 4 5 6
    1586 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    8-24Strata DK I&M    5/99
     
    Figure 8-23 CO Line (RCOU/RCOS, RGLU2, RDDU, PEMU, REMU, RDDU, RDTU) MDF Cross Connect Record
    MDF Block 
    NumberCO Line 
    NumberPCB Type and 
    Cabinet Slot 
    NumberMDF Block 
    NumberCO Line 
    NumberPCB Type and 
    Cabinet Slot 
    NumberMDF Block 
    NumberCO Line 
    NumberPCB Type and 
    Cabinet Slot 
    Number 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    Strata DK I&M    5/998-25
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Figure 8-24 MDF Wiring/CO Lines to RGLU2 or PCOU
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    2345
    Modular
    Cord
    6-1
    1 2
    3 4 5 6
    6-1
    T1
    R1
    T2
    R2T1
    R1
    T2
    R2 To
    Network
    R1
    R2T1
    T2
    Telco-provided
    Modular Block,
    625-Type Or
    Equivalent
    RGLU or PCOU
    #4
    #3
    #2
    #1
    CO3+4
    SameR4
    R3
    T3
    T4 5
    4
    3
    2
    R2
    R1
    T1
    T2 5
    4
    3
    2CO1+2
    PCOU
    Pin-out
    Network Jack: RJ14C
    FIC: 02LS2 (PCOU), 02GS2 (RGLU2)
    1 2
    3 4 5 6
    1598 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    8-26Strata DK I&M    5/99
    Figure 8-25 MDF Wiring/CO to RCOU/RCOS
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    2345
    Modular
    Cord
    1 2
    3 4 5 6
    T1
    R1
    T2
    R2T1
    R1
    T2
    R2 To
    Network
    R1
    R2T1
    T2
    Telco-provided
    Modular Block,
    625-type or
    Equivalent
    SameR8
    R7
    T7
    T8 5
    4
    3
    2
    R2
    R1
    T1
    T2 5
    4
    3
    2
    Network Jack: RJ14C
    FIC: 02LS2
    6-1
    6-1
    4
    3
    2
    1
    7 + 8
    1-6
    1-6
    8
    7
    6
    5
    3 + 4
    5 + 6
    RCOU RCOS
    (DK424 only) 1 + 2 
    1 2
    3 4 5 6SameR4
    R3
    T3
    T4 5
    4
    3
    2
    1 2
    3 4 5 6SameR6
    R5
    T5
    T6 5
    4
    3
    2
    1 2
    3 4 5 6
    1602 
    						
    All Toshiba manuals Comments (0)

    Related Manuals for Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual