Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DK424 Configuration Worksheets Strata DK I&M 5/994-19 DK424 Configuration Worksheets The worksheets help you configure the system. Designed to make the system configuration as orderly as possible, they also provide room to record the hardware - cabinets, PCBs, stations, and options - that comprise the system. Copy the worksheets as required, then fill them out in the order they are given. ©Worksheet 1 – System PCB Slot Requirements ©Worksheet 2 – System Cabinet Assignment Guide ©Worksheet 3 – System PCB Assignment Guide ©Worksheet 4 – Option Configuration Guide ©Worksheet 5 – System Power Factor (PF) Check RC7C1A- 1.7MCabinet 7 Cable Kit - Data and Battery CablesUsed for seven cabinet installations only. Provides long data cable to connect the sixth Expansion Cabinet to the DK424 Base Cabinet. Provides a long battery cable to connect RBDB2 battery distribution box to the sixth Expansion Cabinet power supply. RFIF (up to 7 cabinets)Floor Mount Fixture KitProvides two metal stands for mounting three or more cabinets on floor. Three pairs of wall brackets (RWBF) are supplied with RFIF. Wall brackets are needed to secure floor mounted systems to the wall for safety purposes (not required to wall mount cabinets). RCCB1 (up to 6 cabinets) ...or RCCB2 (7 cabinets)Conduit Connection BoxConduit box required for AC and battery power connection to three or more floor-mounted cabinets. (Not required for mounting two cabinets on a table or any number of cabinets on a wall.) RCCB2 is required instead of RCCB1 for seven cabinet floor mount installations. A licensed electrician must install this item to retain UL listing and/or local electrical code compliance. RPSB1 Three-outlet AC Power StripOne RPSB1 required when installing three or four cabinets (wall or floor mount). Two RPSB1s required when installing five, six, or seven cabinets (wall or floor mount). Two AC cords will exit the cabinets in some configurations. RPSB2 Three-outlet AC Power Strip - heavy cordHigh current carrying capacity cord for application where local electric codes (or user) requires only one AC cord to exit four or more cabinets. It is highly recommended to use the RPSB2 for two-cabinet installations to accommodate further growth. Must be ordered for seven cabinet systems. RWBF Wall bracket pair Required for seven cabinet systems when the system is floor mounted. Secures the seventh cabinet to the wall for safety purposes (not required to wall mount cabinets – see RFIF). Table 4-22 Cabinet Power, Reserve Power, and Floor Mount Hardware Assemblies (continued) AssemblyDescriptionFunction
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements 4-20Strata DK I&M 5/99 Worksheet 1 – System PCB (Slot) Requirements Digital Ports Required Electronic Ports Required Customer Location Digital Telephones (DKTs) 2010-H 2010-SD 2020-S 2020-SD 2004-CT 2001-SLT WRLS-HS 1020-H 1020-SD Total Digital Telephones (DKTs) 1 port per Digital Telephone (1 X Total) Total DDSS Consoles 1 port per Digital DDSS Console (1 X Total) Total PDIU-DS 1 port per Digital PDIU-DS (1 X Total) Total Digital Door Phone/Lock Units (DDCB) 1 port per Digital DDCB (1 X Total) Total Digital Ports Notes ©Digital telephones equipped with RPCI-DI, PDIU-D12 or ADM only require one digital port. (See Table 4-8.) ©One door phone control box (DDCB) supports three door phones (MDFBs). (See Table 4-20.) ©WRLS-HS is the same part number for Digital or Analog (depends on the type installed). Electronic Telephones (EKTs) 6510-S 6510-H 6520-S 6520-SD Total Electronic Telephones (EKTs) 1 port per Electronic Telephone (1 X Total) Total HDSS Consoles 2 ports per HDSS Console (2 X Total) Total Electronic Door Phone/Lock Unit (HDCB) 1 port per HDCB (1 X Total) Total BGM Source Extend Amplifiers 2 ports per amplifier (2 X Total) Total Alternate BGM Source 1 port per Alternate BGM Source (1 X Total) Total Electronic Ports
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements Strata DK I&M 5/994-21 DK424 Configuration Standard Ports Required Standard Telephones On Premise Off Premise Total Standard Telephones 1 port per Standard Telephone (1 X Total) Total Analog Wireless Handsets 1 port per Analog Wireless Handset (1 X Total) Total Voice Mail Ports 1 port per Voice Mail Port (1 X Total) Total Fax or Modem Devices 1 port per fax/modem device (1 X Total) Total ACD/Auto Attendant Digital Announcement Devices 1 port per device (1 X Total) Total Alternate BGM Source 1 port per Alternate BGM Source (1 X Total) Total Other Devices 1 port per device (1 X Total) Total Standard Ports Notes ©Isolation transformer may be required for the Alternate BGM Source, see Chapter 10 – Peripheral Installation. ©Other devices include dictation equipment, etc.
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements 4-22Strata DK I&M 5/99 Station PCBs/Slots Required 1. Total digital ports divided by 8 (round up) = Total PDKU2 PCB slots required Notes lPDKU2 provides eight digital telephone ports (circuits). Circuit 5 (when associated with ports 004, 012, 020, and 028) can only interface with a DDCB. Circuit 8 can only interface with a DDSS console (see Page 4-17). lThe PDKU1 can also be used. The PDKU1 can only support Data Interface Units (DIUs) on circuits 1~7, while the PDKU2 can support DIUs on all eight circuits. See Table 4-20 (example) for slot limitations. 2. Total standard ports divided by 8 (round up) = Total RSTU2 PCB slots required Notes lThe PSTU2 or PSTU1 can also be used. These earlier version PCBs can interface with the same devices that the RSTU can, but they have different ring generators and cannot support MW. See the RSTU/PSTU section in Chapter 7 – DK40i/DK424 Universal Slot PCBs for more details. lThe RSTU2 provides eight standard telephone ports (circuits). Circuit 2 only can connect to a separate Background Music (BGM) source. The RSTU can be equipped with an R48S to extend the loop length of the RSTU from 600 ohms to 1200 ohms (see Table 4-17). lRSTU2 is required to operate message waiting lamps on a standard telephone. 3. Are four or less digital or standard ports needed? If so, RDSU (RSTS) can be used. Total RDSU PCB slots required Total RSTS PCB slots required lRDSU provides two standard telephone ports (circuits) and four digital ports (circuits) in its basic configuration. The optional RSTS can be attached to the RDSU to provide two more standard telephone ports. The RSTU2 can be equipped with an R48S to extend the loop length of the RSTU2 standard telephone ports from 600 ohms to 1200 ohms (see Table 4-17). 4. Total electronic ports divided by 8 (round up) = Total PEKU PCB slots required NotePEKU provides eight electronic telephone ports (circuits). Circuit 5 (when associated with ports 004, 012, 020, or 028) can only interface with an HDCB. The HDSS consoles requires two PEKU (see Table 4-20). Each conference amplifier requires use of circuits 2 and 3 of a PEKU.(Refer to Step 5 before finalizing this number.) 5. Are four or less electronic ports or two or less standard ports needed? If so, PESU can be used. Total PESU PCB slots required NotePESU provides two standard telephone ports (circuits) and four electronic telephone circuits (ports). Circuit 5 (when associated with Ports 004, 012, 020, and 028) can only interface with an HDCB (see Table 4-20). 6. Add totals from Steps 1~5 =Total Station PCB slots required
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements Strata DK I&M 5/994-23 DK424 Configuration CO Line PCBs/Slots Required 1. Determine analog loop start line PCB slot requirements. Total loop start lines (with/ without Caller ID) divided by 8 (round up) = Total RCOU/RCOS PCBs (slots) required Total loop start lines (with/without Caller ID) divided by 4 (round up) = Total RGLU2/RCOU/PCOU PCBs (slots) required(PCOU existing) Total analog loop start line PCB slots required Notes lRGLU2 can provide loop or ground start lines. lRCOU provides four loop start CO lines in its basic configuration. An RCOS can be attached to the RCOU to add four more loop start CO lines for a total of eight per slot. lPCOU2 provides four loop start CO lines. lThe PCOU1 and the PCOU2 are identical in fit, form, and function for the U.S. market. 2. Determine analog ground start line PCB slot requirements. Total ground start lines (with/without Caller ID) divided by 4 (round up) = Total analog ground start line PCB slots required NoteRGLU2 provides four CO lines that can be individually configured as loop start or ground start. 3. Determine E911 CAMA line PCB slot requirements. Total RMCU/RCMS PCBs (1 slot) required (RMCU existing) Total RMCU/RCMS CAMA PCB slots required NoteThe RMCU supports two subassemblies (RCMS) that provide a total of up to four ports. 4. Determine Caller ID (FSK) receiver/decoder PCB slot requirements. Total loop and ground start lines (with Caller ID) divided by 8 (round up) = Total RCIU2/RCIS PCB slots required NoteRCIU2 provides four caller ID receiver/ decoder circuits. RCIU2 with RCIS subassembly provides eight caller ID receiver/decoder circuits. Always use RCIU2 with RCIS for up to eight circuits as opposed to using two RCIU PCBs. These circuits do not use up station port or CO line software assignments. 5. Determine analog Tie line PCB slot requirements.
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements 4-24Strata DK I&M 5/99 Total analog Tie lines (with or without ANI/DNIS) divided by 4 = Total REMU/PEMU PCB slots required Notes lREMU provides four E&M Tie trunks (Type I or II signaling, Wink or Immediate Start, 2- or 4-wire transmission). lThe PEMU1 can also be used. The PEMU only provides Type 1 signaling, 2- or 4-wire transmission and Immediate Start. lSee Table 4-7 for REMU/PEMU maximum quantities. Prior to Release 4, each REMU or PEMU reduced system station port line and capacity by four ports and four lines. With Release 4, Tie lines do not use station ports. 6. Determine analog DID line PCB (slot) requirements. Total analog DID lines (with or without ANI/DNIS) divided by 4 = Total RDDU PCB slots required Notes lRDDU provides four Direct Inward Dialing lines. (Prior to Release 4, each RDDU reduces system station port and line capacity by four ports and four lines.) With Release 4, DID lines do not use station ports. lSee Table 4-7 for RDDU (DID analog lines) maximum quantities. 7. Determine RDTU T1 PCB (slot) requirements (loop/ground/Tie/DID lines). Total loop start lines (channels) Total ground start lines (channels) Total Tie lines (with/without ANI/DNIS) (channels) Total DID lines (with/without ANI/DNIS) (channels) Total RDTU lines required NoteContact the T1 provider (Telco or Carrier company) to determine exact T1 channel/line needs. 8. Determine RDTU PCB (slot) requirements. Total 8-channel RDTU PCB/slots Total 16-channel RDTU PCB/slots (include skipped slots) -2 slots Total 24-channel RDTU PCB/slots (include skipped slots) -2 slots Total RDTU PCB slots required
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements Strata DK I&M 5/994-25 DK424 Configuration Notes lWhen installing 16 or 24 channel RDTU PCBs into a slot, the next slot or two slots may not be usable for other PCBs (Tables 4-4 and 4-5 and Worksheet 2.) lRDTU provides either 8, 16, or 24 channels (lines), depending on programming. Each channel can be set for either DID, ground start CO, loop start CO, or Tie line operation. (Each RDTU Tie line or DID line reduces the system line and station port capacity by one port.) lAs many as six RDTU PCBs can be installed in systems operating with the RCTUC/D common control unit, as many as two with RCTUB operated systems. The RCTUA does not support RDTU. lPrior to Release 4, each Tie or DID line reduced system station capacity by one port. With Release 4, Tie and DID lines do not use station ports. 9. Add totals from Steps 1~7.Total CO Line PCB slots required
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements 4-26Strata DK I&M 5/99 Attendant Console Slots Required PIOU/PIOUS/RSIU/RSSU Option Slots Required PEPU Page Option PCB Required äEnter one slot for each attendant console required (1~4 consoles maximum).Total RATU PCB slots required äEnter number of option PCBs required. Total needed for MIS for ACD (required new) Total needed for remote/local maintenance with DKAdmin/DKBackup PC Total needed for SMDI Total needed for SMDR (existing PIOU) Total needed for miscellaneous options (see Table 4-19) Total PIOU/PIOUS/RSIU/RSSU PCB slots required Notes The following subassembly PCBs do not required additional cabinet slots: lThe IMDU subassembly plugs onto PIOU or PIOUS to provide a remote maintenance modem. lThe RMDS subassembly plugs onto the RSIU to provide a remote maintenance modem. lUp to three RSIS subassemblies can plug onto RSIU to provide any option listed in this Step. äEnter total number of PEPU PCBs needed.Total PEPU PCB slots required NotePEPU provide 600-ohm interface or 3-watt page output for external page/BGM operation.
DK424 Configuration Worksheet 1 – System PCB (Slot) Requirements Strata DK I&M 5/994-27 DK424 Configuration System Slots Required Cabinets Required Important!To determine the type of RCTU PCB required, use Table 4-7. The total Universal slots and features required determine the RCTU PCB needed. ä List the number of slots for each of the following: Total number of Station PCB slots required (see Page 4-22) Total number of CO Line PCB slots required (see Page 4-25) Total number of attendant console slots required (see Page 4-26) Total number of option slots required (see Page 4-26) Total number of page option slots required (see Page 4-26) Total system slots required äTotal system slots divided by 6 or 8 =Total Cabinets required
DK424 Configuration Worksheet 2 – System Cabinet Assignment Guide 4-28Strata DK I&M 5/99 Worksheet 2 – System Cabinet Assignment Guide DK424 and DK280 Base and Expansion Cabinets are interchangeable. The only system considerations are: ©OCA/RPCI configuration requirements ©Channel (8, 16, and 24) RDTU (T1/DS-1 interface) slot configuration requirements ©Number of system slots required. (See “System Slots Required” on Page 4-27.) See Tables 4-7 and 4-8 for OCA/RPCI and T1/DS-1 configuration requirements. CabinetTy p e (DK424 or DK280)Number of Slots Available 1 2 3 4 5 6 7 Total Number of Slots Available Number of Slots Required