Home > Toshiba > Communications System > Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							Strata AirLink Systems
    BSIA System Installation
    Strata DK I&M 5/9916-19
    Strata AirLink Systems
    Step 7: Install the Strata AirLink Manager Software
    1. Check the PC hardware/
    software against the required 
    minimums.Refer to “Check the System Hardware and Software 
    Requirements” on Page 16-3.
    2. Close any open applications 
    in Windows.
    3. Insert the Strata AirLink 
    Manager software floppy 
    disk into the A:\ drive.
    4. In Windows 98/95, click Start 
    and Run
    ...or in Windows 3.11/3.1, 
    open Program Manager and 
    click File and Run.A dialog box displays requesting the location of the setup 
    disk.
    5. Click File and Run. A dialog box displays requesting the location of the setup 
    disk.
    6. Type 
    A:\Setup and click 
    OK.The Windows setup screen appears and warns you to close 
    other Windows applications.
    7. Click Yes A dialog box displays, recommending a destination path 
    of C:\Wireless.
    ...or No if you need to close 
    applications.
    8. Click OK  C:\Wireless is accepted as the destination directory.
    ...or change the destination 
    drive and directory.
    9.  Click OK. A dialog box displays asking for verification of the 
    software location (its program directory or the Windows 
    system directory). It is recommended that the program 
    directory is used.
    10. Select the program directory.
    11. Click OK. The files are copied to the hard disk. A program group is 
    created. 
    						
    							Strata AirLink Systems
    BSIA System Installation
    16-20Strata DK I&M 5/99
    Step 8: Copy the Upgrade Software
    1. Place the Strata AirLink 
    floppy disk #2 into drive A:\.
    2. In Windows 98/95, double-
    click the My Computer icon
    ...or in Windows 3.11/3.1, 
    open Program Manager. 
    3. Navigate to the A: drive.
    4. From the A:\ drive, highlight 
    the file to be copied.
    5. From the Edit pull-down 
    menu, double-click Copy.
    All of the highlighted files are copied to the clipboard.
    6. Navigate to the 
    C:\Wireless\Software 
    subdirectory.
    7. From the Edit pull-down 
    menu, double-click Paste.All of the files on the clipboard are pasted to the 
    subdirectory.
    8. Close all the windows and 
    return to the Strata Airlink 
    Manager application.
    3332
    3505 
    						
    							Strata AirLink Systems
    BSIA System Installation
    Strata DK I&M 5/9916-21
    Strata AirLink Systems
    Step 9: Configure the System 
    Substep A: Activate UTAM1. Make sure the PC is 
    connected to a BSIA.
    2. Turn on the PC. Windows automatically starts.
    3. Double-click the Strata 
    AirLink Manager Desktop 
    icon.This displays only once when the system is initialized.
    4. Type the name, organization 
    (company name) and the 
    password.
    Important!If the password is forgotten, the software must 
    be reloaded. The password can be changed 
    after initialization of the system.
    5. Click Continue. The Password Verification dialog box appears.
    6. Enter the same password and 
    click OK.The Setup dialog box displays again.
    7. Click Continue. The software starts and requests your password.
    Important!If a warning message that the manager 
    cannot open port 1 or 2 is received, check the 
    software port configuration against the 
    hardware configuration.
    8. Enter the password and click 
    OK.
    1. From the Desktop Toolbar, 
    click the Status icon.
    3327
    3289
    3484 
    						
    							Strata AirLink Systems
    BSIA System Installation
    16-22Strata DK I&M 5/99
    2. Click Get UTAM Inputs from 
    Strata Airlink.
    3. Make a note of the BSIA 
    serial number and input codes 
    before calling the Strata 
    AirLink Activation Desk 
    because the staff will request 
    these numbers.
    4. Call the Strata AirLink 
    Activation Desk, (949) 598-
    4980 for the activation code.
    NoteThe hours of operation are: Monday through Friday, 
    8:00 a.m. to 5:00 p.m., Pacific Standard Time.
    After the BSIA serial number and input codes are given to 
    the activation desk, the technician will give you the UTAM 
    system activation code.
    5. Close the Get UTAM Inputs 
    From Strata AirLink window.The Status window displays.
    6. From the Status window, 
    highlight UTAM.
    7. Select Send UTAM 
    Activation Code to Strata 
    AirLink.
    8. From the UTAM Activation 
    Code dialog box, enter the 
    UTAM Activation Code.
    9. Click OK.The message “Wireless system has been activated” 
    displays at the bottom of the Status window.
    Important!Install the UTAM code in one hour or a new 
    one must be obtained.
    3485
    3486
    3487 
    						
    							Strata AirLink Systems
    BSIA System Installation
    Strata DK I&M 5/9916-23
    Strata AirLink Systems
    Substep B: Set the System Time and DateNormal LED indications display on the BSIA (PWR and 
    Master LEDs ON) and Base Stations (PWR LED ON). 
    Several messages display (below) on the PC screen as 
    Strata AirLink Manager tests the installation.
    Important!If the message “Waiting for Wireless 
    Manager” does not appear in the Status 
    window before the progress bar times out, or 
    LED S2 remains lit after a reboot, the BSIA 
    has not been upgraded. Repeat Substeps 1~9.
    1. Click the Configuration icon.
    2. Highlight Preferences.
    3. Click Time and Date.
    3491
    3282
    3274 
    						
    							Strata AirLink Systems
    BSIA System Installation
    16-24Strata DK I&M 5/99
    Substep C: Enter the System Settings4. Enter the time and date.
    5.Click “Automatic daylight 
    savings time adjustment,” if 
    needed.
    6. Send the new data to the 
    configuration file.
    7. Click Close.
    1. Complete the System 
    Settings form.See Table 16-5 on Page 16-28.
    2. Open the Strata AirLink 
    Manager program.
    3. Click the Configuration icon.
    4. Highlight Select Database.
    5. Click System Settings
    ...or double-click “System 
    Settings” in the active 
    window.
    6. Click the Get icon. The current data from the BSIA displays.
    3289
    3270
    3271 
    						
    							Strata AirLink Systems
    BSIA System Installation
    Strata DK I&M 5/9916-25
    Strata AirLink Systems
    Substep D: Configure the Handsets 7. Verify previous settings.
    8. Enter the System and Base 
    Station IDs, and timing 
    intervals.The recommended timing intervals are:
    ©Stop ringing time – 4500 ms
    ©Dial tone delay – 200 ms
    ©DTMF cycle duration – 200 ms
    ©DTMF off duration – 100 ms
    ©Hookflash duration – 500 ms
    ©FT pause duration – 1000 ms
    ©FT inter-event pause – 100 ms
    9. Click the Send icon. The new data is sent to the BSIA.
    10. Save the file (file extension is 
    .sdb).
    1. Complete the User Settings 
    form.See Table 16-6 on Page 16-29.
    2. Ensure that each handset ID 
    corresponds to the correct 
    connector pair.
    3. Open the Strata AirLink 
    Manager program.
    4. Click the Configuration icon.
    5. From the Configure Window, 
    click Select Database and 
    User Database.
    3289
    3272 
    						
    							Strata AirLink Systems
    BSIA System Installation
    16-26Strata DK I&M 5/99
    Substep E: Program the Button Sequences6. Click the Get icon.  The current data from the BSIA displays. 
    7. Verify the previous BSIA 
    settings.
    8. Enter the handset ID.
    9. Save the file (file extension is 
    .udb).
    10. Click the Send icon. The new data is sent to the BSIA.
    1. Complete the Programming 
    Button Sequences form.Consider the order in which commands and text displays 
    should occur during the execution of a telephone feature. 
    See Ta b l e  1 6 - 7  on Page 16-30.
    2. Enter events 1~20 using the 
    command codes or text 
    displays.
    3. Open the Strata AirLink 
    Manager program.
    4. Click the Configuration icon.
    5. From the Configure Window, 
    click Select Database and 
    Feature Table.
    3289
    3273 
    						
    							Strata AirLink Systems
    BSIA System Installation
    Strata DK I&M 5/9916-27
    Strata AirLink Systems
    6. Click Select Event and 
    Commands.
    7. Click a command 
    (
    Hookflash, 1~0, *, #, etc.).The command appears in the designated column (labeled 
    Event 1~20). The Select Event pull-down menu displays.
    8. Highlight Display.
    9. Click an LCD message 
    (
    CALL WAIT
    , CALLBACK
    , 
    CAMPON
    , etc.).The message appears in the designated column (labeled 
    Event 1~20). A completed Feature Table looks like this:
    3264
    3265
    3258 
    						
    							Strata AirLink Systems
    BSIA System Installation
    16-28Strata DK I&M 5/99
    Programming Sheets          10. Repeat Substeps 1~5 as 
    necessary.
    11. Save the file (file extension is 
    .fdb).
    12. Click the Send icon. The new data is sent to the BSIA.
    Table 16-5 System Settings
    ParameterDescriptionUnits/
    RangeSuggested 
    SettingYour 
    Setting
    System IDID for the system (written on the 
    RWIU label).1~5
    Base Station 1 ID ID of the first Base Station. 0~31
    Base Station 2 ID ID of the second Base Station. 0~31
    Stop Ringing TimeLength of time the RWIU waits 
    after last detection of ring voltage 
    on a line before it stops the ring.100 ms
    1
    1. For example, a setting of 2 means 2 x 100 ms or 200 ms.45
    Dial Tone Delay
    2
    2. The Dial Tone Delay eliminates the possibility of a user dialing before the office telephone system is ready.Time delay between pressing 
    &$// and outpulsing DTMF 
    tones.100 ms
    12
    DTMF Cycle DurationDuration of the full DTMF cycle 
    (length of tone plus length of 
    silence between tones) for dialing 
    and other telephone system 
    operations.10 ms
    3
    3. For example, a setting of 2 means 2 x 10 ms or 20 ms.20
    DTMF Off DurationDuration of silence between 
    DTMF tones.10 ms
    310
    Hookflash DurationDuration of the hookflash in 
    signaling the office telephone 
    system.100 ms
    15
    FT Pause DurationDuration of pause events in the 
    Feature Table.100 ms
    110
    FT Inter-event PauseDuration of pause between events 
    in the Feature Table.100 ms
    11
    Second Base Station 
    Service EnabledEnables service for a second 
    Base Station. TRUE if a second 
    Base Station is installed. FALSE if 
    only one Base Station is installed 
    or out of order.NA 
    						