Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PDKU2 Digital Telephone Interface Unit Strata DK I&M 5/997-7 DK40i/DK424 Universal Slot PCBsPrograms 28 and 29: Digital Direct Station Selection Consoles (DDSS) assignments. Program *29: Enables ADMs on 2000-series digital telephones. Program 27: Adjusts initial off-hook volume level for digital telephone handsets. Programs 30, 31: Enables OCA. Programs 77-1, 77-2, 79, *79: Digital Door Phone/Lock Control Unit (DDCB) and door phone ringing assignments. Program 92-5: Initializes initial ringing, speaker, and muted ring volume levels of digital telephones. Backplane Connector 50-Pin Female Amphenol Connector 1371 Figure 7-2 PDKU2 PCB
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PDKU2 Digital Telephone Interface Unit 7-8Strata DK I&M 5/99 PEKU Electronic Telephone Interface Unit System:DK40i Expansion KSU, DK424 Circuits per PCB:eight electronic telephone circuits Interfaces with:electronic telephones HDSS console (circuits 7 and 8 only–each console requires two circuits) alternate BGM source (circuit 3 only) EOCU PCB for OCA external conference amplifier (circuits 2 and 3 only–ports 09 and 10, 17 and 18, 25 and 26, 33 and 34–each amplifier requires two circuits) HDCB (circuit 5 only–ports 004, 012, 020, and 028) Older Version(s):none PEKU controls and interface connectors are shown in Figure 7-4 and described in Table 7-2. Speaker Off-hook Call Announce Unit (EOCU) Installation onto the PEKU (Internal Option) NotePEKU connectors P10, P20, P40, P50, and P60 are positioned to allow installation of the EOCU only in the proper position (Figure 7-3). 1. Mate EOCU connectors J10, J20, J40, J50, and J60 with PEKU connectors P10, P20, P40, P50, and P60. 2. Apply firm, even pressure to EOCU to ensure proper mating of connectors. 3. Use a three-pair cable for making connections between the PEKU and the speaker OCA electronic telephone. 4. Refer to “Electronic Telephone Upgrades” on Page 9-16 for procedures to upgrade electronic telephones for Speaker OCA. NoteElectronic telephones do not support handset OCA. External Options NoteRefer to Chapter 9 – Station Apparatus and Chapter 10 – Peripheral Installation for installation of electronic telephones (including the following upgrades: HVSU2 or HVSU, HVSI for Off-hook Call Announce and HHEU for headset and/or loud ringing bell interface) and external options, respectively. PEKU Configuration to Support an HDSS Console Option 1. Set the SW1 switch to DSS. 2. See “HDSS Console” on Page 9-21 for console installation instructions. Each HDSS console requires dedicated use of circuits 7 and 8 of a particular PEKU PCB. J60 J50J40 J20 J10 1373 Figure 7-3 Off-Hook Call Announce Unit (EOCU) Installation
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PDKU2 Digital Telephone Interface Unit Strata DK I&M 5/997-9 DK40i/DK424 Universal Slot PCBsPEKU Configuration to Support Door Phone/Lock Control Unit (HDCB) 1. Cut the W9 Door Phone jumper wire on the PEKU PCB. 2. Refer to “Door Phone (MDFB)” on Page 9-22 for HDCB, associated Door Phones (MDFBs) and door lock control installation procedures. Only circuit 5 of a PEKU associated with ports 004, 012, 020, and 028 can support HDCBs. PEKU Configuration to Support Separate BGM Source Connection 1. Cut the W5 (BGM) jumper wire on the PEKU PCB. 2. Refer to Chapter 10 – Peripheral Installation for installation procedures for BGM connection. Only circuit 3 can support a BGM source. 3. In Program 10-2, set LED 09 on to enable the PEKU (Port 002) BGM source to be sent to digital and electronic telephone speakers and/or PIOU2, PIOUS2, PEPU PCBs. 4. Use Program 19 to identify the slot in which the PEKU supporting the BGM source will be installed. PEKU Installation 1. Make sure the PEKU has been configured for the appropriate hardware options. See previous pages for more information. 2. Insert the PEKU (component side facing right) into the appropriate slot, and apply firm, even pressure to ensure proper mating of connectors. (For DK40i, the PEKU can be installed only in place of the RSTU2, PDKU, or RDSU. See Chapter 2 – DK40i Configuration.) 3. After installing the PEKU, gently pull the PCB outward. If the connectors are properly mated, a slight resistance will be felt. PEKU Programming Program 03: Door phones, the BGM source connection, and external amplifiers do not require a special code. ä Specify Code 21 to indicate a non-optioned station line PEKU. ä Specify Code 22 to indicate a PEKU configured for Speaker OCA. ä Specify Code 23 to indicate a PEKU configured for an HDSS console. ä Specify Code 24 to indicate a PEKU configured for Speaker OCA and an HDSS console. NoteIf there are no PEKU options, Program 03 can be skipped, and Program 91 can be run instead. Programs 10-2 and 19: BGM connection. Programs 10-3: Assigns external amplifiers to ports. Programs 28 and 29: HDSS console assignments. Programs 77-1, 77-2, 79: HDCB and door phone ringing assignments.
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PDKU2 Digital Telephone Interface Unit 7-10Strata DK I&M 5/99 Table 7-2 PEKU Controls, Indicators, and Connectors Control/Indicator/ConnectorType of ComponentDescription Off-hook call announce P10 10-pin connectorInterface connector for optional Off-hook Call Announce subassembly connector (used with P20, P40, P50, and P60). Off-hook call announce P20 Used with P10, P40, P50, and P60. Off-hook call announce P40 Used with P10, P20, P50, and P60. Off-hook call announce P50 Used with P10, P20, P40, and P60. Off-hook call announce P60Interface connector for optional Off-hook Call Announce subassembly connector (used with P10, P20, P40, and P50). DSS/EKT HDSS Console/ Electronic Telephone SW1 Switch2-position slide switchConfigures PEKU for operation with an HDSS console or electronic telephones. Door phone W9 jumper wire White jumper wireWhen cut, configures PEKU for installation of an optional HDCB. BGM source connection W5 jumper wireWhen cut, configures PEKU for BGM source connection. Backplane Connector SW1 50-Pin Amphenol Connector (Female) EKT DSS W9, cut for HDCB option W5, cut for BGM option P20 P60 P50 P40P10 1372 Figure 7-4 PEKU PCB
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PEPU2 External Page Interface Unit Strata DK I&M 5/997-11 DK40i/DK424 Universal Slot PCBsPEPU2 External Page Interface Unit System:DK40i Expansion KSU, DK424 Circuits per PCB:(see interfaces) Interfaces with:built-in paging amplifier or page speaker door lock control external amplifier control external paging 600 ohm (duplex) interface (one zone) MOH control night relay control Older Version(s):none The PEPU is similar to the PIOU2 and PIOUS2, but supports fewer peripherals than both PCBs. PEPU controls, indicators, and interface connectors are illustrated in Figure 7-5 and described in Table 7-3. PEPU does not support the following PIOU2 and PIOUS2 options: ©Alarm sensor ©Four-zone page ©SMDR port ©Remote maintenance modem or ASCII terminal connector ©IMDU connection NoteRefer to Chapter 10 – Peripheral Installation and Chapter 8 – DK40i/DK424 Universal Slot PCB Wiring for installation of external options. PEPU2 Installation 1. Make sure P15 is in the Mu Law position for U.S. and Canada. 2. Ensure the PEPU2 has been configured for the appropriate hardware options. (Refer to Chapter 10 – Peripheral Installation.) 3. Insert the PEPU2 (component side facing right) into the last slot (S16) of the Base KSU/ cabinet if the system has only a Base KSU/cabinet and no Expansion KSUs/cabinets. If there are Expansion KSU/cabinets, install the PEPU2 in the highest slot number of the highest numbered KSU/cabinet. Apply firm, even pressure to ensure proper mating of connectors. 4. After installing the PEPU2, gently pull the PCB outward. If the connectors are properly mated, a slight resistance is felt. PEPU2 Programming Program 03: Specify Code 41 for the slot that will support a PEPU. Program 10-2: Activates External Page with All Call Page (with access code only, not with $OO&DOO3DJH button). Program 77-1: Assigns relay control options. Program 78: Sets Night Ringing over External Page.
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PEPU2 External Page Interface Unit 7-12Strata DK I&M 5/99 Table 7-3 PEPU Controls, Indicators, and Connectors Control/Indicator/ConnectorType of ComponentDescription M/B make/break jumper plug P10 3-terminal jumper plugExternal page/door lock control relay make or break jumper plug. M/B make/break jumper plug P11 Night/hold relay make or break jumper plug. SPI/SPO internal/external amplifier switch SW42-position slide switchSelects built-in 3-watt amplifier (SPI) or 600- ohm output (SPO) for external page/BGM operation. Volume control VR1 Trim potentiometer Adjusts volume of built-in 3-watt amplifier. Backplane Connector 50-Pin Female Amphenol Connector SPO BBSPIMM SW4 P11P10 VR1 1390 Figure 7-5 PEPU PCB
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PEPU2 External Page Interface Unit Strata DK I&M 5/997-13 DK40i/DK424 Universal Slot PCBsPESU Standard/Electronic Telephone Interface Unit System:DK40i Expansion KSU, DK424 Circuits per PCB:two standard telephone or two-wire device circuits (circuits 1,2)/ four electronic telephone circuits (circuits 5~8) Interfaces with:standard telephone circuits standard telephones voice mail ports off-premises stations alternate BGM source auto attendant digital announcer electronic telephone circuits electronic telephones alternate BGM source (circuit 8 only) EOCU PCB for OCA HDCB (circuit 5 only–ports 004, 012, 020, and 028) external conference amplifier Older Version(s):none The PESU provides a ring generator that can be set for either 130V P-P or 190V P-P for the two standard interface circuits. PESU circuits 3 and 4 are nonfunctional, but they are each assigned a port in system programming. NoteFor the system to recognize the DTMF tones generated by a standard telephone (or any other device connected to a standard telephone port), a DTMF receiver unit (RRCS4, 8, or 12) must be installed on the DK40i K4RCU3 or the DK424 common control unit. PESU controls and interface connectors are shown in Figure 7-6 and described in Ta b l e 7 - 4. DK40i General Information The PESU must be installed in the DK40i Expansion KSU in place of RDSU, RSTU or PDKU. See Chapter 2 – DK40i Configuration. CAUTION!To prevent system malfunction, DO NOT install the PESU in slot 18 of the DK40i system. Installing the Speaker Off-hook Call Announce Unit (EOCU) (Internal Option) 1. Mate the EOCU connectors J10, J20, J40, J50, and J60 (Figure 7-6) with the PESU connectors P10, P20, P40, P50, and P60. NotePESU connectors P10, P20, P40, P50, and P60 are positioned to allow installation of the EOCU only in the proper position. 2. Apply firm, even pressure to the EOCU to ensure proper mating of connectors. 3. Use three-pair cable for connecting the PESU and the Speaker OCA electronic telephone. Refer to Chapter 8 – DK40i/DK424 Universal Slot PCB Wiring for wiring/ interconnecting details.
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PEPU2 External Page Interface Unit 7-14Strata DK I&M 5/99 4. See “PDIU-DI Installation into 1000-series Digital Telephone” on Page 9-9 for procedures to add required speaker OCA upgrade to electronic telephones. External Options NoteRefer to Chapter 9 – Station Apparatus to connect electronic telephones (including the following upgrades: HVSU2 or HVSU/HVSI for Off-hook Call Announce and HHEU for headset and/or Loud Ringing Bell interface), standard telephones, and HDCBs to the PESU. See Chapter 10 – Peripheral Installation to connect peripherals. PESU Configuration to Support Door Phone/Lock Control Unit (HDCB) 1. Cut the W9 door phone jumper wire on the PESU PCB. 2. See “Door Phone/Lock Programming” on Page 9-24 for installation procedures for the HDCB and associated door phones (MDFBs) and door lock control. 3. Each HDCB requires dedicated use of circuit 5 of a particular PESU PCB. PESU Configuration to Support Background Music (BGM) Source 1. Cut the W7 (BGM) jumper wire on the PESU. 2. Refer to Chapter 10 – Peripheral Installation for BGM installation procedures. PESU Configuration for Square Wave Ring Generator ä Ensure the P90 jumper plug is set to the “H” (190V P-P) position for initial installation. The “L” (130V P-P) position is used if devices connected to the PSTU1 or PSTU2 experience ring trip. PESU Installation 1. Make sure that the PESU subunit (ESTS) is securely attached to the PESU (Figure 7-6). 2. Ensure the PESU has been configured for the appropriate hardware options. “PESU Controls, Indicators, and Connectors” on Page 7-15. 3. Insert the PESU into the appropriate slot, and apply firm, even pressure to ensure proper mating of connectors. CAUTION!To prevent system malfunction, DO NOT install the PESU in slot 18 of the DK40i system. 4. After installing the PESU, gently pull it outward. If the connectors are properly mated, a slight resistance will be felt. WARNING! The protective shield on the back of the PESU is designed to protect the installer from potentially hazardous ring voltage. Do not remove this shield.
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PEPU2 External Page Interface Unit Strata DK I&M 5/997-15 DK40i/DK424 Universal Slot PCBsPESU Programming Enter Code 25 in Program 03 for a non-optioned PESU or Code 26 for a PESU supporting Off- hook Call Announce. To program the PESU standard telephone ports, see “PESU Programming” on Page 7-15. To program the PESU electronic telephone ports, see “PESU Programming” on Page 7-15. If there are no PESU options, skip Program 03 and run Program 91 instead. Table 7-4 PESU Controls, Indicators, and Connectors Control/Indicator/ConnectorType of ComponentDescription Off-hook call announce P10 10-pin connectorInterface connector for optional Off-hook Call Announce subassembly connector (used with P20, P40, P50, and P60). Off-hook call announce P20 Used with P10, P40, P50, and P60. Off-hook call announce P40 Used with P10, P20, P50, and P60. Off-hook call announce P50 Used with P10, P20, P40, and P60. Off-hook call announce P60 Used with P10, P20, P40, and P50. Ring voltage jumper plug P90 3-terminal jumperSets ring generator voltage level for circuits 1 and 2. H=190V P-P (factory setting) L=130V P-P Door phone W9 jumper wire White jumper wireWhen cut, configures PESU, circuit 5 for installation of an optional HDCB. BGM W7 jumper packWhen cut, configures PESU, port 07, circuit 8, for BGM source connection (slot 01 only with PCTU2 and PCTU1).
![](/img/blank.gif)
DK40i/DK424 Universal Slot PCBs PEPU2 External Page Interface Unit 7-16Strata DK I&M 5/99 Up PESU P60 P50 P40 W9 P10 P20 ESTS P70 P80Optional EOCU, Equip. for OCA Feature Backplane Connector ESTS: Standard Telephone Interface, Always Equipped From Factory Ring Voltage Option (Ports 1 & 2): L = Low Level (130V P-P) H = High Level (190V P-P) 50-Pin Amphenol Connector (Female) P90 LH Note Connect two ringers maximum per port (H or L). Cut W9 for Door Phone Option (HDCB on Circuit 5) PESU W7Cut W7 Only if BGM Is Connected to Port 07, Circuit 8 1378 Figure 7-6 PESU PCB