    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    Strata DK I&M    5/998-27
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Figure 8-26 RMCU/RMCS Wiring Diagram
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    T1
    R1T1
    R1 To
    Network
    or
    PSAP
    R1
    R2T1
    T2
    RMCU1A
    RCMS1A (2/2)
    LEDs (indicates
    trunk condition)
    Network Busy (NB) LED
    Customer Busy (CB) LED
    RCMS1A (1/2)
    RJ11 2-Pin
    Modular 
    Connector
    CAMA #4
    CAMA #3
    CAMA #2
    CAMA #1
    NB LED
    CB LED NB LED
    CB LED
    NB LED
    CB LED
    Ring
    Tip4
    3
    Ring
    Tip4
    3
    Ring
    Tip4
    3
    Ring
    Tip4
    3
    2798
    Only one circuit is shown connected.
    NOTE: Make sure Tip and Ring are connected
    properly, CAMA lines are polarity sensitive.
    RJ-11 2-pin
    6
    5
    4
    3
    2
    1Ring
    Tip
    6
    5
    4
    3
    2
    1 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    8-28Strata DK I&M    5/99
    GN
    654321Y
    BLR
    BK
    W
    2345
    Modular
    Cords
    R1
    R2T1
    T2
    Dealer Supplied
    Modular Block,
    625-Type or
    Equivalent
    (See Notes)
    R2
    R1
    T1
    T2 5
    4
    3
    2
    CKT 7&8
    1-6
    1-6
    CKT 3&4
    CKT 5&6
    RCIU RCISCKT 1&2
    1 2
    3 4 5 6Same
    Same
    Same
    R4
    R3
    T3
    T4 5
    4
    3
    2
    1 2
    3 4 5 6
    GN
    654321Y
    BLR
    BK
    W
    23452345
    4-Wire
    Modular
    Cord 4-Wire
    Modular
    Cord
    Telco
    RJ14C
    Modular Jack
    T1
    T2
    Dealer Supplied
    Modular Block,
    625-Type or
    Equivalent
    (See Notes)Bridging Jumper WiresR1 R1
    R2 R2GN
    654321Y
    BLR
    BK
    WT1
    T2
    Dealer Supplied
    Modular Block,
    625-Type or
    Equivalent
    (See Notes)
    R2
    R1
    T1
    T2 T1
    R1
    T2
    R2LINE X
    LINE Y Telco
    RJ21X
    5
    4
    3
    2
    Network Jack: RJ14C/RJ21X
    FIC: 02LS2 (Loop Start) OR 02GS2 (Ground Start)
    6-1
    6-16-1 6-1CKT 3&4
    RGLU/RCOU/RCOS/PCOU/TCOUPin-out Pin-outCKT 1&2
    1 2
    3 4 5 6SameR4
    R3
    T3
    T4 5
    4
    3
    2
    1 2
    3 4 5 6
    Network
    RJ21X
    Network
    RJ14C
    RJ14C Telco Jacks
    Telco RJ21X
    4-Wire
    Modular
    CordInstaller Cross Connect Customer
    Supplied Modular Jacks
    Duplex Modular Jack (AA-104A-4 or Equivalent)RCOU 4-Wire Modular Cord
    1
    4-Wire Single Modular Jack (RJ14C) from Telco
    RCIU/RCIS 4-Wire Modular Cord2
    RCOU 4-Wire Modular Cord1
    4-Wire Connector (267A2 Or Equivalent)
    RCIU/RCIS 4-Wire Modular Cord2
    1608
    1. 4-wire modular jacks such as graybar part number AA-104A-4 could be used in place of the two modular jacks; or, 
    a T-connector such as graybar part number 267A2 Adaptor could be used as shown below:
    2. Assign RCIU1/RCIU2/RCIS circuits to the appropriate CO line using Program *50.
    CAUTION!RCIU1 cannot be used in DK40i. Install RCIU2 in slot 17 only of the 
    DK40i Expansion Unit; it must never be installed in slot 18.
    Figure 8-27 RCIU1/RCIS or RCIU2/RCIS MDF Wiring Diagram 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    Strata DK I&M    5/998-29
    DK40i/DK424 Universal 
    Slot PCB Wiring
    DID and Tie Line Wiring
    Figure 8-28 MDF Wiring/DID CO Lines to RDDU
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    2345
    Modular
    Cord
    T1
    R1
    T2
    R2T1
    R1
    T2
    R2 To
    Network
    R1
    R2T1
    T2
    Telco-provided 
    Modular Block,
    625-Type or Equivalent
    R2
    R1
    T1
    T2 5
    4
    3
    2
    RDDU
    Pin-out
    Network Jack: RJ14C
    FIC: 
    6-1
    6-1
    4
    3
    2
    1
    J2 RDDU
    J1
    SameR4
    R3
    T3
    T4 5
    4
    3
    2
    1 2
    3 4 5 6
    1 2
    3 4 5 6
    1605 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    8-30Strata DK I&M    5/99
    REMU
    #4
    #3
    #2
    #1
    8-1
    Line #48-1
    Line #1
    8-1
    Line #3
    8-1
    Line #2
    Same Pinout
    as Line #1
    Same Pinout
    as Line #1 Same Pinout
    as Line #1 To Network Jack
    LEAD — PIN #
    SB — 8
    M—7
    SG — 6
    T—5
    R—4
    E—3
    4WR1 — 2
    4WT1 — 1 To Network Jack
    To Network Jack
    To Network Jack 
    (USOC: RJ1CX)
    1600
    Figure 8-29 MDF Wiring REMU 2/4 Wire Type I/II 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    Strata DK I&M    5/998-31
    DK40i/DK424 Universal 
    Slot PCB Wiring
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    5*34 2*
    Modular
    Cord
    1 2 3 4 5 6
    T
    R
    E
    MT
    R
    E
    M To
    Network
    R
    ET
    MTelco-provided
    Modular Block,
    625-Type or Equivalent
    PEMU
    2-Wire
    #4
    #3
    #2
    #1
    Same
    PEMU
    Pin-out
    Network Jack: RJ2EX
    FIC: TL11M
    6-1 6-1 6-16-1
    6
    5
    4
    3
    2
    1E*R
    T
    *M
    Same
    6
    5
    4
    3
    2
    1E*R
    T
    *M
    Same
    6
    5
    4
    3
    2
    1E*R
    T
    *M
    6
    5
    4
    3
    2
    1E*R
    T
    *M
    6 1
    #4
    #3
    #2
    #1
    *Not Used
    **
    1 2 3 4 5 612 3 4 5 612 3 4 5 6
    1587
    Figure 8-30 MDF Wiring/2-Wire Tie Line to PEMU 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    CO Line Wiring Diagrams
    8-32Strata DK I&M    5/99
    Figure 8-31 MDF Wiring/4-Wire Tie Line to PEMU
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    Bridging
    Clips
    66M150 Split Block
    GN
    654321Y
    BLR
    BK
    W
    2345
    Modular
    Cord
    6-1
    1 2 3 4 5 6
    6-1
    T
    R
    T1
    R1
    E
    M To
    Network
    R
    ET
    MTelco-provided
    Modular Block,
    625-Type Or
    Equivalent
    PEMU
    4-Wire
    #4
    #3
    #2
    #1
    Same
    PEMU
    Pin-out Network Jack: RJ2GX
    FIC: TL31M
    6-1
    6-1
    6
    5
    4
    3
    2
    1E
    R1
    R
    T
    T1
    M
    Same
    6
    5
    4
    3
    2
    1E
    R1
    R
    T
    T1
    M
    Same
    6
    5
    4
    3
    2
    1E
    R1
    R
    T
    T1
    M
    6
    5
    4
    3
    2
    1E
    R1
    R
    T
    T1
    M
    6 1
    #4
    #3
    #2
    #1
    R1 T1
    T
    R
    T1
    R1
    E
    M
    DK, Transmit
    DK, Receive
    SignalingT, R
    T1, R1
    E, M DK Wire Pair Functions
    1 2 3 4 5 612 3 4 5 612 3 4 5 6
    1588 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Option Interface PCB Wiring Diagrams
    Strata DK I&M    5/998-33
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Option Interface PCB Wiring Diagrams
    Figure 8-32 MDF Wiring/PIOU or PEPU Peripherals (25-pair)
    ZonesAccess Codes DK40i and DK424 (RCTUA, 
    RCTUBA/BB, RCTUC/D)Access Codes DK424
    (RCTUE/F equipment with a PIOU)
    A #35 #351
    NoteFour-digit access codes 
    are for RCTUE/F only. 
    Zones E~H require a 
    second PIOU PCB.
    B #36 #352
    C #37 #353
    D #38 #354
    E
    #355
    F
    #356
    G
    #357
    H
    #358
    PIOU 25PR.
    Connections
    PIN COLORMDF 66M
    Block
    PIN
    PG.OUT 1
    PG.IN 1 PEPU/PIOU PCB
    15
    40
    17
    42
    19
    44
    21
    46
    S-Bk
    Bk-S
    O-Y
    Y-O
    Br-Y
    Y-Br
    Bl-V
    V-Bl30
    29
    34
    33
    38
    37
    42
    41 .
    .
    .
    .
    .
    .
    .
    .Zone A or E
    Zone B or F
    Zone C or G
    Zone D or HAll
    Zone
    Page
    (#39)
    Multi-zone Page
    30W max./Composite Impedance
    300 OHMS
    Door
    Lock
    Control
    Amplifier
    Multi-zone Select Relay Function
    with Program 77-1:
    Door Lock Or
    Amp. Control
    BREAK
    PI0
    MAKE
    SW4 SP0
    SP1
    VR1600    (Duplex)
    8
    3 WATT
    P12N.C.
    N.O.Alarm
    Sensor
    P11
    BREAK
    MAKEAlarm
    System
    Night
    Bell
    To Music-on-hold
    Input On PCTU PCB
    P6 Connector. MDF
    Connections
    All Wires Should
    Be Jacketed 24 AWG.
    Twisted Pairs Select Relay Function
    with Program 77-1:
    Night Relay Or
    MOH ControlTape
    Player
    32
    7
    38
    13
    50
    25
    23
    36
    11
    34
    9R-O
    O-R
    Bk-Gn
    Gn-Bk
    V-S
    S-V
    Gn-V
    Bk-Bl
    Bl-Bk
    R-Br
    Br-R13
    14
    25
    26
    49
    50
    46
    21
    22
    17
    18 .
    .
    .
    .
    .
    .
    .
    .
    .
    .
    . DE.T
    DE.R
    SP.T0
    SP.R0
    SP.T1
    SP.R1
    PG.
    Common
    ALM T.
    ALM R.
    NH T.
    NH R.
    W
    W
    8
    SpeakerW
    AMP.
    External
    Background
    Music
    Source Control (PIOU Only)
    PIOU
    Only
    Mute PG.OUT 2
    PG.IN 2
    PG.OUT 3
    PG.IN 3
    PG.OUT 4
    PG.IN 4
    Page
    or BGM
    From
    PCTU
    1589 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Option Interface PCB Wiring Diagrams
    8-34Strata DK I&M    5/99
    Figure 8-33 PIOU/TTY and SMDR Wiring (with PPTC Adapter)
    TTY
    (6-pin
    Modular
    Jack)
    SMDR
    (6-pin
    Modular
    Jack)
    SW2
    LED
    CD4
    (25-pair
    Female
    Amp. 
    Jack)
    See
    PIOU/MDF
    Drawing
    in this
    Section Station Message
    Detail Recording
    RS-232 PortTYSG
    TYCD
    TYDTR
    TYDSR
    TYTD
    TYRD
    6-1SMSG
    SMCD
    SMDTR
    SMDSR
    SMTD
    SMRD
    6-1
    Programmable
    RS-232 PortPIOU
    Card
    6
    1
    6
    1
    2377
    Notes
    See Figure 8-27 for futher details on the PPTC.
    PIOU option settings:
    SW1 — Sets the SMDR baud rate to be 300 or 
    1200 BPS.
    SW2 — Sets the PIOU programming 
    speed to be 300 or 1200 BPS (for 
    IMDU or TTY jack).
    LED CO4 ON = 300 BPS/SW2 set IN.
    LED CO4 OFF = 1200 BPS/SW2 set 
    OUT.
    SW3 — Sets the PIOU to operate with the 
    IMDU or an external device connected 
    to the TTY modular jack.
    — For IMDU operation.
    — For ASCII terminal or 
    external modem.
    W4 — Sets the IMDU and TTY jack for bell 
    or CCITT specification.
    MODEM
    TTY
    6
    1
    6
    1
    3-Pair
    Modular
    Cord Max.
    50 Ft With
    24 AWG
    (cross-pinned) PPTC
    PPTC PPTC connects to any one
    of these devices:
    DKAdmin PC COM Port
    DKBackup PC COM Port
    External RM Modem
    VM SMDI Port
    MIS Device
    SMIS PC COM Port
    CCV PC COM Port
    Insight DK PC COM Port
    PPTC connects to:
    Call Accounting Device or
    Printer 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Option Interface PCB Wiring Diagrams
    Strata DK I&M    5/998-35
    DK40i/DK424 Universal 
    Slot PCB Wiring
    Figure 8-34 PIOUS Page/Relay/Alarm Connections
    Page 
    and BGM
    Alarm 
    Sensor
    Normal 
    Close Normal Open
    ALMT
    ALMR NHR NHT DER DET SPR SPT
    Break
    W1
    Make
    K1
    W2
    K2
    W3
    PIOUS
    ALMNHDE 600
    TBI
    HESB
    or
    Page Amplifier
    Door Lock
    Control
    MOH 
    Source Unit
    Facility
    Alarm Unit
    Night Bell
    Relay Options:
    •  K1 (DE): Door Lock or Amp Mute Control; Program 77-1, LED 07
    •  K2 (NH): Night Relay or Music-on-hold Control; Program 77-1, LED 05 
    •  K1 & K2: 24 VDC, 1 Amp Maximum
    Break
    MakeMute 
    Control
    KSU Backplane
    MDF
    1591
    Notes
    • All wiring connections must be 24 AWG twisted pairs.
    • Dotted lines show optional connections; only one optional connection is allowed. 
    						
    							DK40i/DK424 Universal Slot PCB Wiring
    Option Interface PCB Wiring Diagrams
    8-36Strata DK I&M    5/99
    Figure 8-35 PIOUS SMDR/TTY Options and Wiring (with PPTC Adapter)
    TTY 
    (6-Pin
    Modular
    Jack)
    SMDR
    (6-Pin
    Modular
    Jack)
    SW2
    LED
    CD4
    600 OHM 
    Page TYSG
    TYCD
    TYDTR
    TYDSR
    TYTD
    TYRD
    6-1
    SMSG
    SMCD
    SMDTR
    SMDSR
    SMTD
    SMRD
    6-1
    PIOUS
    CARD
    1
    6
    1
    66
    1
    6
    1
    TB1 to MDF:
    Door Lock/
    Amp, Mute
    Night 
    Relay/ MOH
    Control
    Alarm
    3-Pair
    Modular
    Cord Max.
    50 Ft With
    24 AWG
    (cross-pinned) PPTC
    PPTC PPTC connects to any one
    of these devices:
    DKAdmin PC COM Port
    DKBackup PC COM Port
    External RM Modem
    VM SMDI Port
    MIS Device
    SMIS PC COM Port
    CCV PC COM Port
    Insight DK PC COM Port
    PPTC connects to:
    Call Accounting Device or
    Printer
    2376
    Station Message
    Detail Recording
    RS-232 PortProgrammable
    RS-232 Port
    Notes
    See Figure 8-27 for futher details on the PPTC.
    PIOU option settings:
    SW1 — Sets the SMDR baud rate to be 300 or 
    1200 BPS.
    SW2 — Sets the PIOU programming 
    speed to be 300 or 1200 BPS (for 
    IMDU or TTY jack).
    LED CO4 ON = 300 BPS/SW2 set IN.
    LED CO4 OFF = 1200 BPS/SW2 set 
    OUT.
    SW3 — Sets the PIOU to operate with the 
    IMDU or an external device connected 
    to the TTY modular jack.
    — For IMDU operation.
    — For ASCII terminal or 
    external modem.
    W4 — Sets the IMDU and TTY jack for bell 
    or CCITT specification.
    MODEM
    TTY 
    						