Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

DK40i Installation MDF Wiring Diagrams Strata DK I&M 5/993-43 DK40i Installation Figure 3-27 MDF Wiring to CO Lines (TCOU and TDDU) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Bridging Clips 66M150 SPLIT BLOCK GN 654321Y BL R BK W 2345 Modular Cords 6-1 T1 R1 T2 R2 T3 R3 T4 R4T1 R1 T2 R2 T3 R3 T4 R4 To Network R1 T1 Power Failure Standard Telephone GN 654321Y BL R BK W 2345 R2 T2 GN 654321Y BL R BK W 2345 R3 T3 GN 654321Y BL R BK W 2345 R4 T4 4 3 6-1 6-1 6-1 6-1 PFT DID or CO1 DID or CO2 DID or CO3 DID or CO4DID or CO4/TCIU4 DID or CO3/TCIU3 DID or CO2/TCIU2 DID or CO1/TCIU1 RJ14C/RJ11 Modular Jacks R T 4 3 R T 4 3 R T 4 3 R T 4 3 R T 1680 Network Jack FICTCOU RJ11 02LS2TDDU RJ11 02RV2-T TCOU Only

DK40i Installation MDF Wiring Diagrams 3-44Strata DK I&M 5/99

Strata DK I&M 4/994-1 DK424 Configuration DK424 Configuration4 This chapter explains how to configure the Strata DK424 system. The system has a modular design which enables it to support a number of station and CO line configurations. The main component of the system is the common control unit (RCTU) Printed Circuit Board (PCB). The focus of this chapter is a series of worksheets, providing a systematic procedure for determining the system’s size. The worksheets also provide space to record the hardware and station devices that make up the system. Tables and example worksheets are included to assist you in filling out the worksheets. Important!Prior to Release 4, Tie and DID lines used station ports. With Release 4.0 and higher processors, these lines do not use station ports, allowing larger capacity systems when Tie and DID lines are required. System Configuration Important! System Configuration can be complex and time consuming. For best results: ©Use DKQuote to provide easy, fast, automated configuration. It runs on an IBM-compatible Pentium® PC or higher, equipped with a 110MB or larger hard drive, a 3.5” 1.44 MB high density floppy disk drive, 16MB RAM, and Windows® 98/95 or Windows NT®. See the DKQuote User Guide for more information. ©If the above software is not available, use the Worksheets in this chapter. The DK424’s main components are: the DK424 Base Cabinet (DKSUB424), DK424 Expansion Cabinets (DKSUE424), and four system processors (RCTUA4, RCTUBA3/BB4, RCTUC3/D4, and RCTUE3/F4). The processor used in the system depends on the features and number of telephones and CO lines required. Each cabinet is shipped with its required Power Supply (RPSU280); the same power supply used in DK280 cabinets. See Chapter 5 – DK424 Installation for detailed information on installing RCTU PCBs.

DK424 Configuration System Configuration 4-2Strata DK I&M 5/99 Base Cabinet The DK424 Base Cabinet provides two designated slots for the RCTU processor and six universal slots for station, line, and feature PCBs. It provides six connectors for expanding the system to a maximum of six Expansion Cabinets. It comes with a Motherboard Jumper Unit (MBJU) installed between the R11 and RCTU slot on the front side of the backplane motherboard. The MBJU is removed only when RCTUE/F is installed. MBJU is installed for all other DK Release 1~4 RCTU processor PCBs. Expansion Cabinets Cabinet and Universal Slot Capacity: Up to six DK424 Expansion Cabinets can be connected to a DK424 Base Cabinet. The number of DK424 Expansion Cabinets allowed depends on which processor is installed in the DK424 Base Cabinet. The DK424 Expansion Cabinets support either six or eight universal slots, depending on which processor is installed in the DK424 Base Cabinet. ©All Expansion Cabinets are six slot cabinets except DK424 Expansion Cabinets. DK424 Expansion Cabinets provide eight slots, but only when connected to a DK424 Base Cabinet controlled by an RCTUE3/F3 processor with the MBJU removed. ©No DK424 Expansion Cabinets are allowed when connected to the DK424 Base Cabinet with an RCTUA processor installed. ©One DK424 Expansion Cabinet provides six universal slots when connected to the DK424 Base Cabinet with an RCTUBA/BB processor installed. ©Up to five DK424 Expansion Cabinets provide six universal slots each, when connected to the DK424 Base Cabinet with an RCTUC/D processor installed. ©Up to six DK424 Expansion Cabinets provide eight universal slots each, when connected to a DK424 Base Cabinet with an RCTUE/F processor installed. Table 4-1 shows DK424 cabinet and slot capacities for Release 3 and 4 processors. Table 4-1 DK424 Cabinet and Expansion Slot Capacities Processor in DK424 Base Cabinet 1 1. All cabinets are DK424. DK424 Expansion Cabinets AllowedUniversal Slots allowed per... Base CabinetExpansion CabinetSystem RCTUA 0 1~6 0 6 RCTUBA/BB 1 1~6 1~6 12 RCTUC/D 5 1~6 1~6 36 RCTUE/F 6 1~6 1~8 2 2. Only the RCTUE/F processor allows up to eight universal slots in the DK424 Expansion Cabinet.54

DK424 Configuration System Configuration Strata DK I&M 5/994-3 DK424 Configuration DK424 and DK280 Compatibility DK424 cabinets replace DK280 cabinets in the DK product line structure. DK424 Expansion Cabinets began shipping in June 1995 and DK424 Base Cabinets in February 1997. All old DK280 Release 1~3 processors and DK280 Base/Expansion Cabinets can be mixed with new DK424 Base and Expansion Cabinets with the following criteria (see Ta b l e s 4 - 2 and 4-3): ©DK424 and DK280 Cabinets can be mixed in any combination, with one exception. If seven cabinets are required, an RCTUE/F processor must be installed in a DK424 Base Cabinet and the sixth Expansion Cabinet must be a DK424. In this case DK280 Expansion Cabinets provide six universal slots and DK424 Expansion Cabinets provide eight universal slots. ©DK280 and DK424 Base Cabinets provide six universal slots maximum in any configuration and any RCTU processor can be installed. ©DK280 Expansion Cabinets provide six universal slots maximum in any configuration. Table 4-2 DK280 Base with DK280 and/or DK424 Expansion Cabinets Processor in DK280 Base CabinetExpansion Cabinets AllowedUniversal Slots allowed per... Base CabinetExpansion CabinetSystem RCTUA1, RCTUA3, RCTUA401~60 6 RCTUB1, RCTUB2, RCTUBA3/BB3 or RCTUBA3/BB411~61~612 RCTUC/D2, RCTUC3/D3, RCTUE3/F3 RCTUE3/F451~61~636 Table 4-3 DK424 Base with DK280 and/or DK424 Expansion Cabinets Processor in DK424 Base CabinetExpansion Cabinets AllowedUniversal Slots allowed per... Base CabinetExpansion CabinetSystem RCTUA1, RCTUA3, RCTUA401~60 6 RCTUB1, RCTUB2, RCTUBA3/BB3 or RCTUBA3/BB411~61~612 RCTUC/D2, RCTUC3/D3, RCTUC3/D451~61~636 RCTUE3/F3 RCTUE3/F4 6 1 1. Last Expansion Cabinet must be a DK424.1~61~6 for DK280 Exp. Cabs. 1~8 for DK424 Exp. Cabs.36~54 2 2. Depends on the combination of Expansion Cabinets.

DK424 Configuration System Configuration 4-4Strata DK I&M 5/99 ©DK424 Expansion Cabinets provide six universal slots maximum in any configuration with a DK280 Base Cabinet, including a DK280 Base Cabinet with an RCTUE/F processor. ©DK424 Expansion Cabinets provide eight universal slots in one configuration only: when connected to a DK424 Base Cabinet controlled by an RCTUE/F processor (MBJU jumper must be removed - see installation for details). DK424 cabinets provide six universal slots in all other configurations. ©An RCTUE/F processor can be installed in a DK280 Base Cabinet. When an RCTUE/F processor is installed in a DK280 Base, only five Expansion Cabinets (DK424 and/or DK280) can be installed. These Expansion Cabinets provide only six universal slots. ©All older DK280 Release 1~3 processors will function in the DK424 Base Cabinet. The features available depend on the respective release and type of the RCTU. These processors include RCTUA1, RCTUA3, RCTUB1, RCTUB2, RCTUBA3/BB3, RCTUC1/D2 and RCTUC3/D3. ©When an older processor is installed in the DK424 Base Cabinet, the DK424 and DK280 Expansion Cabinets provide six universal slots and the MBJU jumper must be installed - see RCTU installation for details. ©RCTUA in a DK424 Base allows no Expansion Cabinets. ©RCTUB or RCTUBA/BB in a DK424 Base allows one DK424 or DK280 Expansion Cabinet with six universal slots. ©RCTUC/D in a DK424 Base allows up to five DK424 and DK280 Expansion Cabinets in any combination. These Expansion Cabinets provide six universal slots. Designated Speaker OCA, DIU Data, and T1 slots DK424 systems require that PDKU2 PCBs that support Speaker Off-Hook-Call-Announce (OCA) and PDIU-DS and RPCI-DI PCBs for data applications must be placed in the slots designated in Tables 4-4 and 4-5. NotePDKU2s that support Handset OCA and RPCI TAPI-only can operate in any slot. Additionally, to enable T1/DS-1 interface, the RDTU PCB(s) must be placed in certain slots, with corresponding slots left vacant. (The operation of certain channels necessitates vacant slots.) RDTU PCBs can be placed in the slots in bold type; the vacant slots are not in bold in the following tables. Example: for cabinet 1, if an RDTU is placed in slot 13 and you want to use RDTU channels 17~24, then slot 14 must be left vacant. If you installed a second RDTU, it would go into slot 15; slot 16 must also be vacant if you want to use RDTU channels 17~24.

DK424 Configuration System Configuration Strata DK I&M 5/994-5 DK424 Configuration Table 4-5 pertains to a DK424 Base Cabinet with RCTU-A1, A3, A4, B2, BA3/BB3 or BA3/BB4, C1/D2, C3/D3 or C3/D4 with MBJU or a DK280 Base Cabinet with RCTU-A1, A3, A4, B2, BA3/ BB3, BA3/BB4, C1/D2, C3/D3, C3/D4, E3/F3, E3/F4. DK280 to DK424 Upgrades To upgrade an existing DK280 Base Cabinet to a DK424 Base Cabinet with an RCTUE/F processor, see “DK280 to DK424 Base Cabinet Upgrade Considerations” on Page 5-52. Table 4-4 DK424 or DK280 Base Cabinet with MBJU Removed CabinetTotal Universal Slots PDKU2 Data and Speaker OCA Slots RDTU1/Vacant SlotsNo.2Ty p e 1 DK424 (base) 6 11, 12, 13, 14, 15, 1613/14 315/163 2 DK280 6 21, 22, 23, 24, 25, 26,21/22323/24325/263 2 DK424 8 21, 22, 23, 2421/22323/24325/274/265 3 DK280 6 31, 3231/32333/354/345 3 DK424 8 31, 32, 37, 3831/32333/354/34537/383 4 DK280 6 41, 4241/42343/454/445 4 DK424 8 41, 42, 47, 4841/42343/454/44547/483 5 DK280 6 51, 5251/52353/554/545 5 DK424 8 51, 52, 57, 5851/52353/554/54557/583 6 DK280 6 61, 6261/62363/654/645 6 DK424 8 61, 62, 67, 6861/62363/654/64567/683 7 DK280 6 Cannot be seventh cabinet 7 DK424 8 No Data & Spkr OCA71/77 4/72573/754/745 Table 4-5 DK424 or DK280 Base Cabinet with MBJU CabinetTotal Universal SlotsPDKU2 Data and Speaker OCA Slots RDTU1/Vacant Slots 1. RCTUA does not support RDTU. No.2 2. RCTUB and RCTUBA/BB supports cabinets 1 and 2 only. Ty p e 1 DK424 or DK280 (base) 6 11, 12, 13, 14, 15, 1613/14 3 3. Slot must be vacant for RDTU channels 17-24 (2-slot RDTU positions).15/16 3 2 DK424 or DK280 6 21, 22, 23, 24, 25, 2621/22323/24325/263 3 DK280 or DK424 6 31, 3231/32333/354/345 4. Slot must be vacant for RDTU channels 9-16 (3-slot RDTU positions). 5. Slot must be vacant for RDTU channels 17-24 (3-slot RDTU positions).4 DK280 or DK424 6 41, 4241/42 343/454/445 5 DK280 or DK424 6 51, 5251/52353/554/545 6 DK280 or DK424 6 61, 6261/62363/654/645 These footnotes apply to Tables 4-5 and 4-6:

DK424 Configuration Features Capacities 4-6Strata DK I&M 5/99 Features Capacities The features and capacities of DK424 system processors are provided in Tables 4-6~4-8. Table 4-6 System Feature Capacities DK424 FeaturesDK14DK40iRCTUARCTUBA/BBRCTUC/DRCTUE/F Amplified Conferencing 1 1. Requires additional customer-supplied hardware. 02 4 4 4 4 Auto Attendant (built-in) simultaneous announcements3 5 12 12 24 24 Caller ID/ANI/CNIS Abandoned Call Numbers: stored per station10~100 10~100 10~100 10~100 10~100 10~100 Caller ID/ANI/CNIS Abandoned Call Numbers: stored per system200 200 200 400 1000 2000 CO Line Groups 4 8 8 8 16 16 Distributed Hunt (DH) Calls in Queue per Groups 10 10 10 10 10 10 DH Groups 16 16 16 16 16 16 DH stations per Group 8 28 32 32 32 32 DNIS Network Routing Numbers 0 100 100 200 300 300 DNIS Numbers 0 200 200 350 500 500 DTMF receivers 3 5 12 12 24 24 External Page Zones 0 4 4 4 4 8 Call Park Orbits - general 20 20 20 20 20 20 Call Park Orbits - individual 10 28 32 80 240 336 Personal LCD Messages per DKT 2 2. Personal Messages includes: timed reminder memo and station speed dial memo. 10 10 10 10 10 10 Personal Message DKTs 8 16 16 32 96 96 [PhDNs] per System 10 28 32 80 240 336 [PDNs] per System 10 28 32 80 240 336 Ring Tones 3 3 3 3 3 3 Simultaneous Party Conferencing (4-party) 2 3 3 7 7 14 Simultaneous Two-CO Line conferencing (3-party)24 4 10 1020 Station Speed Dial 40 40 40 40 40 40 Stratagy DK Systems (per tenant group) 1 1 1 1 1 1 Stratagy DK Systems (per system) 0 2 2 2 4 4 System LCD Messages 40 40 40 40 40 40 System Speed Dial 40 40 40 100 100 800 Telephone Page Groups 5 5 5 5 9 9 Telephone Group Page – simultaneous stations paged8 28 32 80 120 120 Telephone Pickup Groups 8 20 20 20 20 20 Tenants 2 2 2 4 4 4 Toll Restriction (AC/OC) Table 8 8 8 8 16 16 Toll Restriction Classes 4 4 4 4 8 8 Verified Account Codes 300 300 300 300 300 500 Voice Mail SMDI Yes Yes Yes Yes Yes Yes

DK424 Configuration Features Capacities Strata DK I&M 5/994-7 DK424 Configuration Table 4-7 Line Capacities and Universal Printed Circuit Board Slots DK424 Lines and PCB SlotsDK14DK40iRCTUARCTUBA/BBRCTUC/DRCTUE/F Universal slots 0 4 1 1. There are four universal slots in the DK40i expansion unit. 6123654 CO lines – loop start 4 12 216 2 2. All CO line capacities assume a PIOU, PIOUS, PEPU, RSSU, or RSIU is installed for RCTUBA/BB, RCTUC/D or RCTUE/F, but no Caller ID RCIU2/RCIS PCBs. 48 2144 2200 2 CO lines – ground start 0 12 16 240 2136 2200 2 DID lines (analog) 0 12 16 3 3. Limits apply to analog DID and Tie lines, not T1 DID/Tie lines. 40 3136 3200 3 Tie lines (analog) 0 12 16 340 3136 3200 3 T1 (DS-1) lines each) 0 0 0 484 4. T1 lines can be loop start, ground start, Tie, or DID (maximum 24 lines per unit, any type or combination). 144 4192 4 ISDN BRI (S/T or U) B channel lines 0 0 85 5. BRI lines provide CO line services, including Caller ID, DID and Direct Inward Lines (DIL). 16 516 516 5 ISDN PRI (T) B channel lines 0 0 0 47 6 6. PRI lines provide CO line services, including Caller ID, ANI, DID, Tie, POTS, FX and DIL. 141 6188 6 Squared System Maximum (lines + stations)4 lines + 4 stations12 lines + 12 stations16 lines + 16 stations48 lines + 48 stations144 lines + 144 stations200 lines + 200 stations Table 4-8 Station and Peripherals Capacities DK424 StationsDK14DK40iRCTUARCTUBA/BBRCTUC/DRCTUE/F Add-on modules (DADM) 8 12 12 40 120 200 Attendant consoles 0 0 0 2 4 4 DKT 2004-CT Cordless Telephones 8 28 32 80 240 336 DKT 2004-CT simultaneous calls 8 9 9 9 9 9 Door locks 2 3 4 5 5 5 Door phones (MDFB) 6 9 9 12 12 12 DSS consoles 0 3 3 4 8 8 ISDN BRI station circuits TE-1 and TA (2B+D per circuit) 1 1. ISDN BRI TE-1 and TA include ISDN telephones, modems, video conference interfaces, etc. Up to two stations (TE-1 and/ or TA) can connect to and share one BRI S-type circuit. Only one station can connect to a BRI U-type circuit. 008 24 48 72 Handset OCA stations 8 28 32 80 240 336 Off-premise stations 2 20 32 80 232 328 PDIU-DS 2 2. Speaker OCA, PDIU and RPCI capacity is determined by 2B channel slot availability and power supply limits. 7 24 31 79 160 208 RPCI-DI used for data + TAPI, per system 28 24 32 80 144 200 RPCI-DI used for TAPI only: per cabinet 2N/A N/A 32 40 40 40 RPCI-DI used for TAPI only: per system 28 24 32 80 186 280 Speaker OCA stations 28 28 32 80 160 208 Standard stations 2 20 24 72 232 328 Telephones – DKT 8 28 3 3.To install the maximum of 28 total DKTs and EKTs in the DK40i, up to 16 of the stations can be EKTs and at least 8 of the stations must be DKTs. 32 4 4. Maximum capacity of DKT/EKT stations per DK424 cabinet is 62, less for EKT 2000, 3000 (Power Factor limitation). 80 4 240 4 336 4 Telephones – EKT 0 16 3 32 4 80 4 240 4 328 4

DK424 Configuration System Capacity 4-8Strata DK I&M 5/99 System Capacity The number of CO lines and stations needed determine the size of the system. Ta b l e s 4 - 9 and 4-12 show the station and line capacities for eight-port RCOU/RCOS CO line PCBs. There is a trade-off between stations and lines. Every group of eight stations installed decreases the CO line capacity of the system by eight, and vice versa. The exact hardware requirements depend on the features required. Tables 4-9~4-12 assume one cabinet slot is used for an Optional Interface PCB. Table 4-9 Strata DK424 Expansion Cabinet Configuration for Eight-Port CO Line PCBs Without Caller ID 1 Cabinet RCTUA2 Cabinets RCTUB or RCTUBA/BB3 Cabinets RCTUC/D4 Cabinets RCTUC/D5 Cabinets RCTUC/D6 Cabinets RCTUC/D7 Cabinets RCTUE/F CO LinesStationsCO LinesStationsCO LinesStationsCO LinesStationsCO LinesStationsCO LinesStationsCO LinesStations 16 32 48 40 72 64 96 88 120 112 144 136 200 224 44 40 68 64 92 88 116 112 140 136 196 224 40 48 64 72 88 96 112 120 136 144 192 232 36 48 60 72 84 96 108 120 132 144 188 232 32 56 56 80 80 104 104 128 128 152 184 240 28 56 52 80 76 104 100 128 124 152 180 240 24 64 48 88 72 112 96 136 120 160 176 248 20 64 44 88 68 112 92 136 116 160 172 248 16 72 40 96 64 120 88 144 112 168 168 256 12 72 36 96 60 120 84 144 108 168 164 256 8 80 32 104 56 128 80 152 104 176 160 264 28 104 52 128 76 152 100 176 156 264 24 112 48 136 72 160 96 184 152 272 20 112 44 136 68 160 92 184 148 272 40 144 64 168 88 192 144 280 36 144 60 168 84 192 140 280 32 152 56 176 80 200 136 288 28 152 52 176 76 200 132 288 24 160 48 184 72 208 128 296 44 184 68 208 124 296 40 192 64 216 120 304 36 192 60 216 116 304 32 200 56 224 112 312 52 224 108 312 48 232 104 320 44 232 100 320 40 240 96 328 92 328 88 336 84 336