Home > Toshiba > Communications System > Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							DK40i Configuration
    Base/Expansion KSU Compatibility
    Strata DK I&M 5/992-3
    DK40i Configuration
    Base/Expansion KSU Compatibility
    Expansion Units that are compatible with various Base KSUs are shown in Ta b l e  2 - 2.
    Table 2-2 Compatible Base KSUs and Expansion Units
    Station, Lines, and Stratagy DK Voice Mail
    The optional DK40i Expansion KSU has four universal slots which can support Stratagy DK, loop 
    and ground start lines, DID and Tie lines, ISDN BRI S/T lines and stations, Toshiba and analog 
    stations, and option interface PCBs. PCBs that support lines and can be installed in the expansion 
    unit are the RCOU/RCOS, KCDU, REMU, RBSU, or RDDU (see Ta b l e  2 - 3).
    PCBs that can support stations and be installed in the expansion unit are the PDKU2, RDSU, 
    PEKU, RSTU2, PESU, RBSU/RBSS, RWIU, and KCDU. PCBs that can interface SMDR, SMDI, 
    and a local or remote DKAdmin Personal Computer are PIOU, PIOUS, and RSSU (see Ta b l e  2 - 4). 
    Base KSUExpansion Unit
    DK40iDK16eDK16
    DK16XXX
    DK16eXX
    DK40XX
    DK40iXX
    X = Expansion Unit is compatible with Base KSU.
    Table 2-3 DK40i Expansion KSU Components 
    PCBCircuits per PCBInterfacesConnector
    KCDU2 CO line circuits/
    4 digital telephone 
    circuitsCentral office loop start linesRJ14C modular (CO Line 
    circuits)
    Digital circuits same as PDKU2, except no 
    DDSS25-pair Amphenol (digital 
    telephone circuits)
    PDKU28 digital telephone 
    circuitsDigital telephones (with or without RPCI-DI 
    or ADM)
    DDSS console
    PDIU-DSs
    DDCB
    Cordless Digital Telephone (DKT2004-CT)25-pair Amphenol 
    PEKU8 electronic telephone 
    circuitsElectronic telephones
    HDSS console
    Alternate BGM source
    EOCU PCB for OCA
    External conference amplifier
    HDCB25-pair Amphenol 
    PESU2 standard telephone 
    circuits/
    4 electronic telephone 
    circuits (standard/
    electronic telephone 
    ports)Standard: same as RSTU (no MW)
    Electronic: same as PEKU, except PESU 
    does not support HDSS console25-pair Amphenol  
    						
    							DK40i Configuration
    Base/Expansion KSU Compatibility
    2-4Strata DK I&M    5/99
    PIOU, 
    PIOUS, 
    RSSUA PIOU or PIOUS can use an IMDU. See Table 2-4 for details.25-pair Amphenol (PIOU, 
    PEPU)
    Spring clip terminal 
    (PIOUS)
    RBSU2 ISDN BRI S/T circuits 
    (station or line)
    1
    ISDN BRI S/T TE-1s and Terminal 
    Adaptors and ISDN BRI S/T line circuits 
    connected to an NT-1 adaptor.RJ-45
    RBSSTwo ISDN BRI S/T 
    circuits (station only)ISDN BRI S/T TE-1s and Terminal 
    Adaptors.RJ-45
    RWIU8 or 16 digital circuits for 
    Strata AirLinkUp to four base stations (16 handsets max.)RJ-12 (6-wire modular 
    jack)
    RCIU24 Caller ID circuits
    8 circuits with RCISLoop or ground start lines with Caller ID. 
    Requires: RCOU, RGLU2 or PCOU.RJ14C modular
    RCOU4 CO line circuits (lines) Central office loop start lines RJ14C modular
    RDDU4 Direct Inward Dialing 
    (DID) circuitsDID lines RJ14C modular
    RDSUWithout RSTS:
    2 Standard telephone/
    4 Digital telephone 
    circuits
    With RSTS:
    4 Standard telephone/
    4 Digital telephone 
    circuitsDigital: Same as PDKU2, except no DDSS 
    Console
    Standard: Same as RSTU2 (standard 
    telephone message waiting not available)25-pair Amphenol 
    REMU4 Tie line circuitsE&M Tie lines
    2- or 4-wire transmission
    Type I Signaling
    Type II Signaling
    Immediate start
    Wink startREMU (8-wire modular 
    jack) USOC RJ1CX 
    modular, 2- or 4-wire/Type 
    I or II 
    R48S8 standard telephone 
    circuitsOptionally interfaces to the RSTU2 and 
    RDSU to extend loop length of standard 
    telephones from 600 ohms to 1200 ohms.25-pair Amphenol 
    RGLU24 Line circuits Loop or ground start lines RJ14C modular
    RSTU28 Standard telephone 
    circuitsStandard telephones
    Voice mail ports
    Off-premises stations
    Other similar devices
    Alternate BGM source
    Auto attendant digital announcer
    Message waiting lamp generator25-pair Amphenol 
    Stratagy 
    DK2 VM ports
    4 VM ports
    6 VM ports
    8 VM ports
    All the above Stratagy 
    DK systems use 8 station 
    ports in the DK40i 
    software.None None
    1. Each circuit can be set independently for line or station side (S/T BRI). Table 2-3 DK40i Expansion KSU Components 
    (continued)
    PCBCircuits per PCBInterfacesConnector 
    						
    							DK40i Configuration
    Base/Expansion KSU Compatibility
    Strata DK I&M 5/992-5
    DK40i Configuration
    Peripherals
    An Expansion KSU can support PIOU, PIOUS, RSSU and PEPU PCBs (see Ta b l e  2 - 4 for a list of 
    options).
    PIOU or PIOUS
    The PIOU/PIOUS provides one dedicated RS-232 port for Station Message Detail Recording 
    (SMDR) connection to a call accounting device and one of the following:
    ©a TTY/RS-232 port which can connect to a customer-provided VM SMDI or external modem 
    for remote maintenance, or to a local PC with DKAdmin
    ©connectors for an internal modem (IMDU) for remote maintenance and administration
    RSSU
    The RSSU provides one TTY/RS-232 port for a connection to a VM SMDI or customer-provided 
    external modem for remote maintenance, or to a local PC with DKAdmin. The RSSU does not 
    support SMDR or IMDU.
    Any device that connects to the PIOU, PIOUS, or RSSU should not be considered a station and 
    does not affect the systems station capacity.
    Table 2-4 DK40i Interface PCB Options
    Interface Options1
    1. Amplified page output (single zone, 3 watts, 8 ohms) on the PIOU and PEPU is not available on the DK40i.
    RSSUPIOUPIOUSPEPUTSIUDK40i Base 2
    2. These functions are standard (built-in) to the DK40i Base KSU.Zone page interface (unamplified, 4 zones)
    X
    Unamplified page output (single zone, 600 
    W, 
    duplex)X
    Night transfer or Music-on-hold control relayXXX X
    Door lock or external amplifier control relayXXXX
    IMDU disables TTY output when piggy-backed onto 
    PIOU or PIOUS cardsXX
    Remote Maintenance using customer-provided 
    external modem, StrataControl and/or DKAdmin PC 
    (requires TTY output port)
    XXXX
    SMDR output (RS-232/6-wire modular connector)XX X
    Alarm sensorXX
    Voice Mail SMDI (requires TTY output port)XXX X 
    						
    							DK40i Configuration
    Feature Capacities
    2-6Strata DK I&M    5/99
    Feature Capacities
    The DK40i line, system feature and station capacities are shown in Ta b l e s  2 - 5~2-7.
    Table 2-5 DK40i Line Capacities and Universal Printed Circuit Board Slots
    Lines and PCB SlotsDK40i
    Universal slots
    1
    1. There are four universal slots in the DK40i expansion unit.4
    1
    CO lines – loop start 12
    CO lines – ground start 12
    DID lines (analog)
    2
    2. In the D40i, DID, Tie, and BRI lines do not use up station ports as in DK40 and the DK424, R3. Each BRI line 
    circuit uses up to two CO lines of system capacity12
    Tie lines (analog)
    212
    ISDN BRI S/T type line circuits (each circuit requires an NT-1 device)
    26 circuits
    (12 B-channel/lines)
    Squared System Maximum
    (ground/loop lines + stations)12 lines + 
    12 stations
    Squared System Maximum
    (Tie/DID lines + stations)12 lines + 
    12 stations
    Table 2-6 DK40i System Feature Capacities 
    FeaturesDK40i
    Amplified Conferencing
    12
    Auto Attendant (built-in) simultaneous calls in dialing queue 5
    Caller ID/ANI Abandoned Call Numbers - stored per station 10~100
    Caller ID/ANI Abandoned Call Numbers - stored per system 200
    CO Line Groups8
    Distributed Hunt (DH) Calls in Queue per Groups 10
    DH Groups16
    DH stations per Group 28
    DNIS Network Routing Numbers 100
    DNIS Numbers200
    DTMF receivers5
    External Page Zones4
    Call Park Orbits - general 20
    Call Park Orbits - individual 28
    Personal LCD Messages per DKT
    210
    Personal Message DKTs 16
    [PhDNs] per System28
    [PDNs] per System28
    Ring Tones3
    Simultaneous Party Conferencing (4-party) 3
    Simultaneous Two-CO Line conferencing (3-party) 4
    Station Speed Dial40
    Stratagy DK Systems (per tenant group) 1 
    						
    							DK40i Configuration
    Feature Capacities
    Strata DK I&M 5/992-7
    DK40i Configuration
    Stratagy DK Systems (per system) 2
    System LCD Messages 40
    System Speed Dial40
    Telephone Page Groups 5
    Telephone Group Page – simultaneous stations paged 28
    Telephone Pickup Groups 20
    Tenants2
    Toll Restriction (AC/OC) Table 8
    Toll Restriction Classes 4
    Verified Account Codes 300
    Voice Mail Simplified Message Desk Interface (SMDI) Yes
    1. Requires additional customer-supplied hardware.
    2. Personal Messages includes: timed reminder memo and station speed dial memo.
    Table 2-7 DK40i Station and Peripherals Capacities
    StationsDK40i
    Add-on modules (DADM) 12
    Attendant consoles 0
    DKT 2004-CT Cordless Telephones (simultaneous calls) 9
    DKT 2004-CT Cordless Telephones 28
    Door locks3
    Door phones9
    DSS consoles3
    Handset OCA stations 28
    Off-premise stations 20
    PDIU-DS
    1
    1. Speaker OCA, PDIU and RPCI capacity is determined by PDKU 2B channel slot availability and power supply 
    limits.24
    RPCI-DI used for data + TAPI (per system) 24
    RPCI-DI used for TAPI only (per system)124
    Speaker OCA stations
    128
    Standard stations 20
    Telephones – DKT 28
    2
    2. To install the maximum of 28 total DKTs and EKTs, up to 16 of the stations can be EKTs and at least 8 of the 
    stations must be DKTs. Telephones – EKT 16
    2
    ISDN Terminal Adapters and/or TE-1s combined10 circuit
    (20 devices)3
    3. In the DK40i, BRI station circuits do not use up CO line numbers as in the DK424, R4. Each BRI station circuit 
    uses up to two station ports of system capacity. Toshiba BRI (S/T) station circuits are passive and allow up to 
    two devices to share a circuit. Telephones – Strata Airlink Handsets 16 Table 2-6 DK40i System Feature Capacities 
    (continued)
    FeaturesDK40i 
    						
    							DK40i Configuration
    Station Considerations
    2-8Strata DK I&M    5/99
    Station Considerations
    For configuration purposes, any device which is connected to a dedicated telephone circuit is 
    considered a “station.” Although the words “telephone” and “station” are often used 
    interchangeably in Strata DK40i documentation, devices other than telephones—such as Stand-
    alone Data Interface units (PDIU-DSs)—should also be considered stations when configuring a 
    system since they require a dedicated telephone circuit. A station apparatus overview is shown in 
    Table 2-8.
    Table 2-8 Strata DK40i Station Apparatus Overview
    Station
    Type/Number of 
    Circuits 
    RequiredPCB or 
    InterfaceCircuit(s)
    Base 
    Unit
    CapacityBase & 
    Expansion 
    Unit 
    Combined 
    Capacity
    Digital telephone (DKT without 
    ADM or RPCI-DI) or Cordless 
    Digital Telephone 
    (DKT2004-CT)Digital, one for 
    each DKTBase KSU
    PDKU2
    KCDU
    RDSU1~8
    1~8
    1~4
    5~8828
    Stand-alone Data Interface 
    Unit (PDIU-DS)Digital, one for 
    each PDIU-DSBase KSU
    PDKU2
    KCDU
    RDSU1~8
    1~8
    1~4
    5~8727
    Digital Direct Station Selection 
    Console (DDSS)Digital, one for 
    each DDSSBase KSU
    PDKU28
    813
    Digital Door Phone/Lock 
    Control Unit (DDCB)Digital, one for 
    each DDCBBase KSU
    PDKU2 or
    first KCDU5
    1
    113
    Electronic Telephone (EKT)Electronic, one 
    for each EKTPEKU
    PESU1~8
    5~8016
    Electronic Direct Station 
    Selection Console (HDSS)Electronic, two 
    for the HDSSPEKU 7 and 8 0 2
    Conference amplifierElectronic, two 
    for the amplifierPEKU
    PESU6 and 7
    6 and 702
    Single-wire-pair devices:
    Standard telephone
    Voice mail device
    Facsimile machine
    Modem
    Dictation equipmentStandard, one 
    for each device 
    (voice mail 
    devices may 
    require more 
    than one circuit)KSTU2
    RSTU2
    PESU
    RDSU
    RDSU/RSTS1~4
    1~8
    1~2
    1~2
    1~4420
    Alternate BGM source
    May require interface 
    transformer, see Chapter 10 – 
    Peripheral InstallationStandard or 
    electronic, one 
    for the sourceKSTU2
    PEKU
    PESU
    RSTU22
    3
    8
    211 
    						
    							DK40i Configuration
    Telephone Circuit (Port) Types
    Strata DK I&M 5/992-9
    DK40i Configuration
    Telephone Circuit (Port) Types
    There are four types of telephone circuits to which stations can be connected: digital, electronic, 
    and standard telephone circuits. Also, there are ISDN (S/T) type telephone circuits, terminal 
    equipment (TE-1) and terminal adaptor circuits. 
    Digital Telephone Circuit Connections
    The Strata DK40i Base KSU and the PDKU2 PCB each provide eight digital telephone circuits. 
    Each KCDU and RDSU PCB provides four. The RWIU PCB provides circuits to support up to 16 
    wireless digital telephones.
    NoteA maximum of four KCDU PCBs can be installed. If installed, KCDUs should be installed 
    per configuration tables. The following devices can be connected to digital telephone 
    circuits (see Ta b l e  2 - 9). Telephones connected to KCDU PCBs cannot be relocated or 
    swapped using the station relocation feature.
    Table 2-9 Digital Telephone Circuits
    Digital DeviceCircuits
     RequiredComments
    Digital telephones
    (2000- and 1000-series, 
    Cordless Digital Telephone-
    DKT2004-CT)1Each digital telephone circuit can support a digital telephone. Only one 
    of the following options can be installed on a 2000-series digital 
    telephone: RPCI-DI, DVSU (SP-OCA) or ADMs.
    NoteThe RPCI-DI) and the Add-on Module (ADM) do not require a 
    dedicated circuit. They share a circuit with the telephone.
    Stand-alone Data Interface 
    Units (PDIU-DS)1Any digital telephone circuit, except for circuit 8 on a PDKU21, can 
    support a PDIU-DS.
    NoteThere are two versions of the PDKU2: PDKU21 and PDKU2. 
    The versions are identical, except that circuits 1~8 on the 
    PDKU2 can each support PDIU-DSs/RPCI-DI, while only 
    circuits 1~7 on a PDKU21 can support PDIU-DSs/RPCI-DIs.
    Digital Direct Station Selection 
    Console (DDSS)1DDSS consoles can connect only to circuit 8 in the Base KSU and 
    circuit 8 on a PDKU2. The KCDU cannot support a DDSS console.
    Digital Door Phone/Lock Control 
    Box (DDCB)1DDCBs can only connect to Port 04 in the Base KSU, and Ports 12 
    and/or 20 on either the PDKU2 or KCDU.
    Wireless Integrated Handsets 1 Each RWIU supports up to 32 Strata AirLInk integrated handsets. 
    						
    							DK40i Configuration
    Telephone Circuit (Port) Types
    2-10Strata DK I&M    5/99
    Electronic Telephone Circuit Connections
    There are no electronic telephone circuits in the Base KSU, and none can be added to it. However, 
    either the PEKU PCB, which has eight electronic telephone circuits, or the PESU, which has four 
    electronic telephone circuits, can be installed in the Expansion KSU.
    The following devices can be connected to electronic telephone circuits (see Table 2-10).
    Table 2-10 Electronic Telephone Circuits
    CAUTION!You must always calculate the Power Factor (PF)—see Worksheet 2. Exceeding 
    the PF will cause the power supply to fail. If PF is exceeded, replace EKTs with 
    DKTs.
    Standard Telephone Circuit Options
    In addition to supporting standard telephones, each of the standard telephone circuits can support 
    any one of a number of single-wire-pair devices, including voice mail/Auto Attendant devices and 
    modems (see Table 2-11).
    Table 2-11 Standard Telephone Circuits
    ISDN Station Devices
    ISDN station devices must be S/T type. Each device requires a DK40i BRI circuit configured for 
    station side, as opposed to line side. Two BRI circuits are provided by each of the ISDN PCBs: 
    TBSU, RBSU, and RBSS. ISDN station devices include ISDN telephones, modems, terminal 
    adaptors, video cards, etc. A maximum of 10 BRI circuits can be provided for ISDN stations.
    Electronic DeviceCircuits
    RequiredComments
    Electronic telephones
    (6500-, 6000-, 3000-, 2000-
    series)
    1Each electronic telephone circuit can support an electronic 
    telephone.
    Electronic Direct Station Selection 
    Console (HDSS)
    2
    The system supports only one HDSS console. The console must 
    be connected to both circuits 7 and 8 on the PEKU. The PESU will 
    not support an HDSS console.
    Alternate BGM source
    1
    The system supports an alternate BGM source which can be 
    heard over digital and electronic telephone and external page 
    speakers. This source can be connected to either circuit 3 on a 
    PEKU, circuit 8 on a PESU, or circuit 4 on a KSTU2 or PSTU PCB.
    Conference amplifier
    2
    Up to three amplifiers for two CO line conferencing can be 
    connected to ports 9 and 10; 17 and 18; and 24 and 25 on a PEKU 
    or PESU.
    Base KSUExpansion KSU
    Standard Telephone CircuitsKSTU2RSTU2PESURSTU1 or 
    PSTURDSU/
    RSTS
    Number of Standard Telephone Circuits 4 8 2 8 2/2
    Supports Message Waiting Lamps on SLTs No Yes No No No 
    						
    							DK40i Configuration
    Worksheet 1 – System PCB Assignment Guide
    Strata DK I&M 5/992-11
    DK40i Configuration
    Worksheet 1 – System PCB Assignment Guide
    This worksheet helps you configure the system. Use the following tables to record the hardware 
    that comprises the system. To ensure that the system port/line capacity is not exceeded, consult 
    Configuration Tables 2-13~2-16 when you fill out Tables 2-13 and 2-14 below. After configuring 
    the system, use Worksheet 2 to ensure that the system power factors are not exceeded.
    Be sure to consult “Example Configuration Tables” on Page 2-13 when filling out these tables.
    Table 2-12 Hardware Configuration
    Base Cabinet Port/Line Capacity Check
    Table 2-13 Strata DK40i Base Cabinet Station Port Configuration
    Table 2-14 Strata DK40i Base Cabinet Line ConfigurationCustomer:
    Location:
    Base CabinetExpansion Cabinet
    Slot 
    No.001112131415161718
    PCB 
    TypeNone or 
    K4RCU3,
    K5RCU or 
    K5RCU28 DKTsNone
    None None
    Universal 
    PCBUniversal 
    PCBUniversal 
    PCBUniversal 
    PCB (except 
    Stratagy DK)  TCOU (4 
    Loop Start 
    Lines)
    TDDU (4 
    DID Lines)
    KSTU2
    4  SLTTCIU2
    4 CLID
    TBSU (2 
    BRI Ckts.)
    Installed (Yes/No)PCB TypePort Type Port Total
    Yes Motherboard Digital Telephone (8 ports) 8
    KSTU2 Standard Telephone (4 ports)
    TBSU circuit #1 ISDN station side (2 ports)
    TBSU circuit #2 ISDN station side (2 ports)
    Total Base Ports (16 ports max.) =
    Installed (Yes/No)PCB TypeNumber of Line TypesLine Total
    TCOU Loop start (4 lines)
    TDDU Direct Inward Dial (4 lines)
    TBSU circuit #1 ISDN line side (2 lines)
    TBSU circuit #2 ISDN line side (2 lines)
    Total Base Lines (4 lines max.) = 
    						
    							DK40i Configuration
    Worksheet 1 – System PCB Assignment Guide
    2-12Strata DK I&M    5/99
    Expansion Capacity
    Base and Expansions Cabinet Port/Line Capacity Check
    Refer to Tables 2-13~2-15 when filling in Table 2-16 to determine the DK40i Expansion Capacity.
    Table 2-16 Strata DK40i Base and Expansion CO Line ConfigurationTable 2-15 Strata DK40i Expansion PCB Port/Line Capacity Reference Table
    Expansion PCBPort/Line TypeNo. of PortsNo. of Lines
    PCOU Loop Start Lines 0 4
    RCOU Loop Start Lines 0 4
    RCOU/RCOS Loop Start Lines 0 8
    RGLU Ground or Loop Start Lines  0 4
    RDDU Direct In Dial Lines 0 4
    REMU E&M Tie Lines 0 4
    PEMU E&M Tie Lines 0 4
    KCDU Digital Ports/Loop Lines 4 2
    PDKU2 Digital Telephone Ports 8 0
    RSTU2 Standard Telephone Ports 8 0
    RWIU Strata AirLink Wireless Interface  8 or 16 0
    Stratagy DK Built-in Voice Mail System 8 0
    RDSU 2 Standard/4-Digital Telephone Ports 8 0
    RDSU/RSTS 4 Standard/4 Digital Telephones ports  8 0
    PEKU Electronic Telephone Ports 8 0
    PESU 2 Standard/4 Electronic Telephone Ports 8 0
    RBSU2 ISDN BRI S/T circuits, station side or line side in any 
    combination shown below:
    lBoth circuits line side04
    lBoth circuits station side40
    l1 station and 1 line circuit22
    RBSS 2 ISDN BRI S/T circuits 4 0
    Expansion
    Slot No.PCB 
    InstalledPort Type or Line TypePortsLines
    15
    16
    17
    18
    Total Ports and Lines in Expansion slots (15~18)
    Total Base Unit ports and lines 
    (from Tables 2-12 and 2-13)
    Total DK40i Base/Expansion ports and lines 
    (28 ports/12 lines max.) 
    						
    All Toshiba manuals Comments (0)