Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ISDN Interfaces RBSU/RBSS and TBSU Interface Units Strata DK I&M 5/9914-35 ISDN Interfaces Figure 14-30 Incoming Call Setup Output of BRI Call Monitor
ISDN Interfaces RBUU/RBUS Interface Unit 14-36Strata DK I&M 5/99 RBUU/RBUS Interface Unit System:DK424, Release 4.2 and above Circuits per PCB:2 circuits (2B + D each circuit) Interfaces with:ISDN BRI U when connected to the Public Network or a BRI U-type TE-1 or TA devices when connecting to ISDN station equipment Older Version(s):none The DK424 Release 4.2 system supports the RBUU/RBUS interface unit (Figures 14-31 and 14-32) according to the common control units resident in the system. LEDs on the RBUU/RBUS show a continuous status of operation. Refer to Table 14-13 for a list of each LED’s status. Figure 14-33 shows the location of the LEDs and connectors. RBUU Installation Before installing a RBUU PCB into a DK424, a number of system programs must be run. We recommends running these programs in the order listed before installation. This allows the RBUU to function immediately upon insertion beginning with a self-check loop-back test and then normal operation. Before you can begin installation of the RBUU, you may have to install the subassemblies. ä To install the subassemblies (RBUS) ä Place the RBUS card (component side facing down) onto the RBUU connectors. Apply firm, even pressure to ensure proper seating of the connectors. The RBUS card should have been installed at the factory. ä To install an RBUU PCB 1. Insert the RBUU (component side facing right) into the appropriate slot and apply firm, even pressure to ensure proper seating of connectors. 2. After installing the RBUU, gently pull the PCB outward. If the connectors are properly seated, a slight resistance is felt.
ISDN Interfaces RBUU/RBUS Interface Unit Strata DK I&M 5/9914-37 ISDN Interfaces Figure 14-31 RBUU PCB Figure 14-32 RBUS Subassembly RBUU1A RBUU1 2799 RBUU1A P2 P4P7 J2 J1 P5P6 P3 J3P8 P9 BSY TS LOS FS BSY TS LOS FS RJ-45 Modular for Circuit 1 RJ-45 Modular for Circuit 2 LED Indicator for Circuit 1 LED Indicator for Circuit 2 RS-232C Monitor OutputDIN Connector RBUS1A F2800 RBUS1A BSY TS LOS FS BSY TS LOS FS J7 J6 RJ-45 Modular for Circuit 3 LED Indicator for Circuit 3 RJ-45 Modular for Circuit 4 LED Indicator for Circuit 4
ISDN Interfaces RBUU/RBUS Interface Unit 14-38Strata DK I&M 5/99 Figure 14-33 Location of LEDs and Connectors (RBUU/RBUS) Table 14-13 RBUU/RBUS LED Indications LEDIndication BSY Busy TS Time Synchronization LOS Loss of Signal FS Frame Synchronization RBUU1A RS-232C Monitor Output BSY TS LOS FS BSY TS LOS FS 2801 RBUS1A RJ-45 Modular for Circuit 3 BSY TS LOS FS BSY TS LOS FS RJ-45 Modular for Circuit 4 RJ-45 Modular for Circuit 1 RJ-45 Modular for Circuit 2 LED Indicator for Circuit 1 LED Indicator for Circuit 2 LED Indicator for Circuit 3 LED Indicator for Circuit 4
ISDN Interfaces RBUU/RBUS Interface Unit Strata DK I&M 5/9914-39 ISDN Interfaces
ISDN Interfaces RBUU/RBUS Interface Unit 14-40Strata DK I&M 5/99
Strata DK I&M 5/9915-1 Hospitality Management Information System (HMIS)15 This chapter gives you information about the Hospitality Management Information System (HMIS), including: ©HMIS Server/Workstation PC requirements ©Installation steps ©Setup Utility ©Maintenaince and troubleshooting HMIS comes in a complete software package or a turnkey system that has all of the components pre-installed in the PC. The software package includes: ©HMIS application and documentation CD-ROM ©Printed user guide ©Symantec™ pcANYWHERE™ ©HMIS activation key For additional information, see the Hospitality Management Information System (HMIS) General Description and HMIS User Guide.
Hospitality Management Information System (HMIS) Minimum PC Requirements 15-2Strata DK I&M 5/99 Minimum PC Requirements HMIS Server To ensure proper operation of HMIS, the following minimum PC requirements must be met. The turnkey package PC is also listed and can be used as a reference for the recommended PC requirements. Table 15-1 Minimum Specifications HardwareMinimumRecommended PCIntel® Celeron® Pentium® 200 MHz (or higher) with Universal Serial Bus (USB) port 1 1. Port used to plug-and-play peripherals using one interrupt and address. Toshiba Equium™ 7000D with Intel Pentium 200 MHz (or higher) and USB port 1 RAM 32MB 32MB Hard Drive 2GB 3GB Disk Drive 3.5” 1.44MB Floppy 3.5” 1.44MB Floppy CD-ROM 8 Speed 24 Speed Network Interface Card (NIC)10BASE-T EtherLink® 2 2. Required if the server and workstations are networked. 10/100BASE-T EtherLink2 Monitor 14-inch SVGA .28n 15-inch SVGA .28n Video Card SVGA with 1MB VRAM SVGA with 1MB VRAM Keyboard Standard 101/102 Standard 101/102 Mouse PS/2 PS/2 Parallel Ports1 (for activation key and customer- supplied printer)1 (for activation key and customer- supplied printer) Serial Ports 2 2 Modem 33.6 kbps or higher 33.6 kbps or higher Uninterrupted Power Supply (UPS) 3 3. UPS is part of the turnkey package. It is highly recommended to protect the server from power failure that can corrupt data. ONEAC® (highly recommended)ONEAC® (highly recommended) BackupTape or Zip® drive (highly recommended)Tape or Zip® drive (highly recommended) Connectors N/A 2 PPTC-9(F) SoftwareMinimumRecommended Windows 95B/98 4 4. Required for USB support. Same Remote Symantec pcANYWHERE Same
Hospitality Management Information System (HMIS) Installation Strata DK I&M 5/9915-3 HMIS Workstation Installation Step 1: Check Strata DK System Requirements The Strata DK must have SMDR and TTY ports to transmit and receive data to the HMIS. HMIS connects to Strata DK using the TTY and SMDR ports on a PIOU, PIOUS, RSIU, or RSSU at 1200, 2400, or 4800 baud (see “Connect HMIS PC to Strata DK” on Page 15-4). RSIU with RSSU is the recommended configuration. If SMDR is also used for general purposes, in addition to hotel guest billing records, it requires a customer-supplied Y-connector (see to a general purpose printer or call accounting device. Table 15-2 Minimum Specifications HardwareMinimumRecommended PCIntel Celeron Pentium 150MHz (or higher) with USB portToshiba Equium 7000D with Intel Pentium 233MHz (or higher) and USB port RAM 32MB 32MB Hard Drive 1GB 3GB Disk Drive3.5” 1.44MB Floppy 3.5” 1.44MB Floppy CD-ROM 8 Speed 8 Speed NIC 10BASE-T EtherLink 1 1. Required if the server and workstations are networked. 10BASE-T EtherLink1 Monitor 14-inch SVGA .28n 15-inch SVGA .28n Video Card SVGA with 1MB VRAM SVGA with 1MB VRAM Keyboard Standard 101/102 Standard 101/102 Mouse PS/2 PS/2 Serial Ports 2 2 Parallel Ports 1 (for customer-supplied printer) 1 (for customer-supplied printer) SoftwareMinimumRecommended Windows 95B/98 2 2. Required for USB support. 95B/982 2380 MNTR2 MNTR1 Call Center Viewer Y Connector MASTER DK MIS Figure 15-1 Customer-supplied Y- Connector
Hospitality Management Information System (HMIS) Installation 15-4Strata DK I&M 5/99 Important! ©The Automatic Wake-up Call function has some specific Strata DK system requirements that are: ©One dedicated digital station port and one digital telephone to provide Automatic Wake- up Call. ©An external customer-supplied music source or digital announcer is required for optional music or greeting for guests who receive Auto Wake-up calls. The telephone system must have an available standard station port on an RSTU2 or RDSU card. ©An RSIU with two RSIS cards are required for Stratagy Voice Mail (SMDI interface). See Stratagy Hospitality Application Software Technical Bulletin (TB40-0022) for details. Step 2: Make Sure You Have Everything ©HMIS-SWK CD-ROM with the HMIS software and documentation ©Printed HMIS User Guide; Strata DK Installation and Maintenance Manual, Chapter 15; and other applicable documentation (bulletins, etc.) ©Symantec pcANYWHERE ©Adobe® Acrobat® Reader ©HMIS activation keys ©PPTC-9 and PPTC-25F connectors ©UPS (optional) ©Five-port network hub (optional) NotePrinter not included. Step 3: Inspect HMIS Server/Workstation PCs CAUTION!Always wear an anti-static wrist strap when inspecting HMIS system components. Important!Before powering on, remove the computer cover and verify that all cards (i.e., internal modem, SVGA, and network cards) are seated and secured properly. Make any adjustments necessary and replace the cover. Step 4: Connect HMIS PC to Strata DK HMIS interfaces directly to the DK424/DK280 Release 3.1 or higher and the DK40i, by connecting the PC to the TTY and SMDR ports. HMIS comes standard as a server/workstation configuration. If additional terminals are needed, HMIS workstations can be networked using a LAN.