Home > Toshiba > Communications System > Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 766
    							ISDN Interfaces
    RBSU/RBSS and TBSU Interface Units
    Strata DK I&M 5/9914-35
    ISDN Interfaces
    Figure 14-30 Incoming Call Setup Output of BRI Call Monitor 
    						
    							ISDN Interfaces
    RBUU/RBUS Interface Unit
    14-36Strata DK I&M 5/99
    RBUU/RBUS Interface Unit
    System:DK424, Release 4.2 and above
    Circuits per PCB:2 circuits (2B + D each circuit)
    Interfaces with:ISDN BRI U when connected to the Public Network or a BRI U-type TE-1 or TA devices 
    when connecting to ISDN station equipment
    Older Version(s):none
    The DK424 Release 4.2 system supports the RBUU/RBUS interface unit (Figures 14-31 and 
    14-32) according to the common control units resident in the system.
    LEDs on the RBUU/RBUS show a continuous status of operation. Refer to Table 14-13 for a list 
    of each LED’s status.
    Figure 14-33 shows the location of the LEDs and connectors.
    RBUU Installation
    Before installing a RBUU PCB into a DK424, a number of system programs must be run. We 
    recommends running these programs in the order listed before installation. This allows the RBUU 
    to function immediately upon insertion beginning with a self-check loop-back test and then normal 
    operation. Before you can begin installation of the RBUU, you may have to install the 
    subassemblies.
    ä
    To install the subassemblies (RBUS)
    ä
    Place the RBUS card (component side facing down) onto the RBUU connectors. Apply firm, 
    even pressure to ensure proper seating of the connectors. The RBUS card should have been 
    installed at the factory.
    ä
    To install an RBUU PCB
    1. Insert the RBUU (component side facing right) into the appropriate slot and apply firm, even 
    pressure to ensure proper seating of connectors.
    2. After installing the RBUU, gently pull the PCB outward. If the connectors are properly seated, 
    a slight resistance is felt. 
    						
    							ISDN Interfaces
    RBUU/RBUS Interface Unit
    Strata DK I&M 5/9914-37
    ISDN Interfaces
    Figure 14-31 RBUU PCB
    Figure 14-32 RBUS Subassembly
    RBUU1A
    RBUU1
    2799
    RBUU1A
    P2 P4P7
    J2 J1
    P5P6
    P3
    J3P8 P9
    BSY
    TS
    LOS
    FS
    BSY
    TS
    LOS
    FS
    RJ-45 Modular
    for Circuit 1
    RJ-45 Modular
    for Circuit 2
    LED Indicator
    for Circuit 1
    LED Indicator
    for Circuit 2
    RS-232C
    Monitor OutputDIN Connector
    RBUS1A
    F2800
    RBUS1A
    BSY
    TS
    LOS
    FS
    BSY
    TS
    LOS
    FS
    J7
    J6
    RJ-45 Modular
    for Circuit 3
    LED Indicator
    for Circuit 3
    RJ-45 Modular
    for Circuit 4
    LED Indicator
    for Circuit 4 
    						
    							ISDN Interfaces
    RBUU/RBUS Interface Unit
    14-38Strata DK I&M 5/99
    Figure 14-33 Location of LEDs and Connectors (RBUU/RBUS)
    Table 14-13 RBUU/RBUS LED Indications 
    LEDIndication
    BSY Busy
    TS Time Synchronization
    LOS Loss of Signal
    FS Frame Synchronization
    RBUU1A
    RS-232C
    Monitor Output
    BSY
    TS
    LOS
    FS
    BSY
    TS
    LOS
    FS
    2801
    RBUS1A
    RJ-45 Modular
    for Circuit 3
    BSY
    TS
    LOS
    FS
    BSY
    TS
    LOS
    FS
    RJ-45 Modular
    for Circuit 4
    RJ-45 Modular
    for Circuit 1
    RJ-45 Modular
    for Circuit 2
    LED Indicator
    for Circuit 1
    LED Indicator
    for Circuit 2
    LED Indicator
    for Circuit 3
    LED Indicator
    for Circuit 4 
    						
    							ISDN Interfaces
    RBUU/RBUS Interface Unit
    Strata DK I&M 5/9914-39
    ISDN Interfaces 
    						
    							ISDN Interfaces
    RBUU/RBUS Interface Unit
    14-40Strata DK I&M 5/99 
    						
    							Strata DK I&M    5/9915-1
    Hospitality Management Information 
    System (HMIS)15
    This chapter gives you information about the Hospitality Management Information System 
    (HMIS), including:
    ©HMIS Server/Workstation PC requirements
    ©Installation steps
    ©Setup Utility
    ©Maintenaince and troubleshooting
    HMIS comes in a complete software package or a turnkey system that has all of the components 
    pre-installed in the PC. The software package includes:
    ©HMIS application and documentation CD-ROM
    ©Printed user guide
    ©Symantec™ pcANYWHERE™
    ©HMIS activation key
    For additional information, see the Hospitality Management Information System (HMIS) General 
    Description and HMIS User Guide. 
    						
    							Hospitality Management Information System (HMIS)
    Minimum PC Requirements
    15-2Strata DK I&M    5/99
    Minimum PC Requirements
    HMIS Server
    To ensure proper operation of HMIS, the following minimum PC requirements must be met. The 
    turnkey package PC is also listed and can be used as a reference for the recommended PC 
    requirements.
    Table 15-1 Minimum Specifications
    HardwareMinimumRecommended
    PCIntel® Celeron® Pentium® 200 MHz (or 
    higher) with Universal Serial Bus (USB) 
    port
    1
    1. Port used to plug-and-play peripherals using one interrupt and address.
    Toshiba Equium™ 7000D with Intel 
    Pentium 200 MHz (or higher) and USB 
    port
    1
    RAM 32MB 32MB
    Hard Drive 2GB 3GB
    Disk Drive 3.5” 1.44MB Floppy 3.5” 1.44MB Floppy
    CD-ROM 8 Speed 24 Speed
    Network Interface Card 
    (NIC)10BASE-T EtherLink®
    2
    2. Required if the server and workstations are networked.
    10/100BASE-T EtherLink2
    Monitor 14-inch SVGA .28n 15-inch SVGA .28n
    Video Card SVGA with 1MB VRAM SVGA with 1MB VRAM
    Keyboard Standard 101/102 Standard 101/102
    Mouse PS/2 PS/2
    Parallel Ports1 (for activation key and customer-
    supplied printer)1 (for activation key and customer-
    supplied printer)
    Serial Ports 2 2
    Modem 33.6 kbps or higher 33.6 kbps or higher
    Uninterrupted Power 
    Supply (UPS)
    3
    3. UPS is part of the turnkey package. It is highly recommended to protect the server from power failure that 
    can corrupt data.
    ONEAC®
    (highly recommended)ONEAC®
    (highly recommended)
    BackupTape or Zip® drive
    (highly recommended)Tape or Zip® drive
    (highly recommended)
    Connectors N/A 2 PPTC-9(F)
    SoftwareMinimumRecommended
    Windows 95B/98
    4
    4. Required for USB support.
    Same
    Remote Symantec pcANYWHERE Same 
    						
    							Hospitality Management Information System (HMIS)
    Installation
    Strata DK I&M    5/9915-3
    HMIS Workstation
    Installation
    Step 1: Check Strata DK System Requirements
    The Strata DK must have SMDR and TTY ports to 
    transmit and receive data to the HMIS. HMIS 
    connects to Strata DK using the TTY and SMDR 
    ports on a PIOU, PIOUS, RSIU, or RSSU at 1200, 
    2400, or 4800 baud (see “Connect HMIS PC to 
    Strata DK” on Page 15-4). RSIU with RSSU is the 
    recommended configuration.
    If SMDR is also used for general purposes, in 
    addition to hotel guest billing records, it requires a 
    customer-supplied Y-connector (see to a general 
    purpose printer or call accounting device.
    Table 15-2 Minimum Specifications 
    HardwareMinimumRecommended
    PCIntel Celeron Pentium 150MHz (or 
    higher) with USB portToshiba Equium 7000D with Intel 
    Pentium 233MHz (or higher) and USB 
    port
    RAM 32MB 32MB
    Hard Drive 1GB 3GB
    Disk Drive3.5” 1.44MB Floppy 3.5” 1.44MB Floppy
    CD-ROM 8 Speed 8 Speed
    NIC 10BASE-T EtherLink
    1
    1. Required if the server and workstations are networked.
    10BASE-T EtherLink1
    Monitor 14-inch SVGA .28n 15-inch SVGA .28n
    Video Card SVGA with 1MB VRAM SVGA with 1MB VRAM
    Keyboard Standard 101/102 Standard 101/102
    Mouse PS/2 PS/2
    Serial Ports 2 2
    Parallel Ports 1 (for customer-supplied printer) 1 (for customer-supplied printer)
    SoftwareMinimumRecommended
    Windows 95B/98
    2
    2. Required for USB support.
    95B/982
    2380
    MNTR2
    MNTR1 Call Center Viewer Y Connector
    MASTER
    DK MIS
    Figure 15-1 Customer-supplied Y-
    Connector 
    						
    							Hospitality Management Information System (HMIS)
    Installation
    15-4Strata DK I&M    5/99
    Important!
    ©The Automatic Wake-up Call function has some specific Strata DK system requirements that 
    are:
    ©One dedicated digital station port and one digital telephone to provide Automatic Wake-
    up Call.
    ©An external customer-supplied music source or digital announcer is required for optional 
    music or greeting for guests who receive Auto Wake-up calls. The telephone system must 
    have an available standard station port on an RSTU2 or RDSU card.
    ©An RSIU with two RSIS cards are required for Stratagy Voice Mail (SMDI interface). See 
    Stratagy Hospitality Application Software Technical Bulletin (TB40-0022) for details.
    Step 2: Make Sure You Have Everything
    ©HMIS-SWK CD-ROM with the HMIS software and documentation
    ©Printed HMIS User Guide;  Strata DK Installation and Maintenance Manual, Chapter 15; and 
    other applicable documentation (bulletins, etc.)
    ©Symantec pcANYWHERE
    ©Adobe® Acrobat® Reader
    ©HMIS activation keys
    ©PPTC-9 and PPTC-25F connectors
    ©UPS (optional)
    ©Five-port network hub (optional)
    NotePrinter not included.
    Step 3: Inspect HMIS Server/Workstation PCs
    CAUTION!Always wear an anti-static wrist strap when inspecting HMIS system 
    components.
    Important!Before powering on, remove the computer cover and verify that all cards (i.e., 
    internal modem, SVGA, and network cards) are seated and secured properly. Make 
    any adjustments necessary and replace the cover.
    Step 4: Connect HMIS PC to Strata DK
    HMIS interfaces directly to the DK424/DK280 Release 3.1 or higher and the DK40i, by 
    connecting the PC to the TTY and SMDR ports. HMIS comes standard as a server/workstation 
    configuration. If additional terminals are needed, HMIS workstations can be networked using a 
    LAN. 
    						